메뉴 건너뛰기




Volumn 16, Issue 6, 2010, Pages 467-475

Clinical applications of fiber-optic probes in optical coherence tomography

Author keywords

Endoscopic OCT; Intravascular OCT; Needle OCT; Optical coherence tomography, OCT

Indexed keywords

ENDOSCOPY; FIBER OPTICS; NEEDLES; PROBES;

EID: 78649716712     PISSN: 10685200     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.yofte.2010.09.013     Document Type: Article
Times cited : (20)

References (95)
  • 2
    • 0242322532 scopus 로고    scopus 로고
    • Optical coherence tomography for ultrahigh resolution in vivo imaging
    • J.G. Fujimoto Optical coherence tomography for ultrahigh resolution in vivo imaging Nat. Biotechnol. 21 2003 1361 1367
    • (2003) Nat. Biotechnol. , vol.21 , pp. 1361-1367
    • Fujimoto, J.G.1
  • 7
    • 0037315654 scopus 로고    scopus 로고
    • Delay and dispersion characteristics of a frequency-domain optical delay line for scanning interferometry
    • A.V. Zvyagin, E.D.J. Smith, and D.D. Sampson Delay and dispersion characteristics of a frequency-domain optical delay line for scanning interferometry J. Opt. Soc. Am. A 20 2003 333 341
    • (2003) J. Opt. Soc. Am. A , vol.20 , pp. 333-341
    • Zvyagin, A.V.1    Smith, E.D.J.2    Sampson, D.D.3
  • 8
    • 0001936881 scopus 로고
    • Measurement of intraocular distances by backscattering spectral interferometry
    • A.F. Fercher, C.K. Hitzenberger, G. Kamp, and S.Y. El-Zaiat Measurement of intraocular distances by backscattering spectral interferometry Opt. Commun. 117 1995 43 48
    • (1995) Opt. Commun. , vol.117 , pp. 43-48
    • Fercher, A.F.1    Hitzenberger, C.K.2    Kamp, G.3    El-Zaiat, S.Y.4
  • 9
    • 0031695986 scopus 로고    scopus 로고
    • "Coherence radar" and "spectral radar"-new tools for dermatological diagnosis
    • G. Häusler, and M.W. Lindner "Coherence radar" and "Spectral radar"-new tools for dermatological diagnosis J. Biomed. Opt. 3 1998 21 31
    • (1998) J. Biomed. Opt. , vol.3 , pp. 21-31
    • Häusler, G.1    Lindner, M.W.2
  • 11
    • 0000063301 scopus 로고    scopus 로고
    • Optical coherence tomography using a frequency-tunable optical source
    • S.R. Chinn, E.A. Swanson, and J.G. Fujimoto Optical coherence tomography using a frequency-tunable optical source Opt. Lett. 22 1997 340 342
    • (1997) Opt. Lett. , vol.22 , pp. 340-342
    • Chinn, S.R.1    Swanson, E.A.2    Fujimoto, J.G.3
  • 12
    • 33644746298 scopus 로고    scopus 로고
    • Endoscope-tip interferometer for ultrahigh resolution frequency domain optical coherence tomography in mouse colon
    • A.R. Tumlinson, J.K. Barton, B. Považay, H. Sattman, A. Unterhuber, R.A. Leitgeb, and W. Drexler Endoscope-tip interferometer for ultrahigh resolution frequency domain optical coherence tomography in mouse colon Opt. Express 14 2006 1878 1887
    • (2006) Opt. Express , vol.14 , pp. 1878-1887
    • Tumlinson, A.R.1    Barton, J.K.2    Považay, B.3    Sattman, H.4    Unterhuber, A.5    Leitgeb, R.A.6    Drexler, W.7
  • 14
    • 0028538082 scopus 로고
    • Optical properties of normal and carcinomatous bronchial tissue
    • J. Qu, C. MacAulay, S. Lam, and B. Palcic Optical properties of normal and carcinomatous bronchial tissue Appl. Optics 33 1994 7397 7405
    • (1994) Appl. Optics , vol.33 , pp. 7397-7405
    • Qu, J.1    MacAulay, C.2    Lam, S.3    Palcic, B.4
  • 15
    • 17444395269 scopus 로고    scopus 로고
    • The effect of water dispersion and absorption on axial resolution in ultrahigh-resolution optical coherence tomography
    • T.R. Hillman, and D.D. Sampson The effect of water dispersion and absorption on axial resolution in ultrahigh-resolution optical coherence tomography Opt. Express 13 2005 1860 1874
    • (2005) Opt. Express , vol.13 , pp. 1860-1874
    • Hillman, T.R.1    Sampson, D.D.2
  • 19
    • 0001673084 scopus 로고    scopus 로고
    • Ultrahigh resolution optical coherence tomography using a supuerluminescent light source
    • A.M. Kowalevicz, T. Ko, I. Hartl, J.G. Fujimoto, M. Pollnau, and R.P. Salathé Ultrahigh resolution optical coherence tomography using a supuerluminescent light source Opt. Express 10 2002 349 353
    • (2002) Opt. Express , vol.10 , pp. 349-353
    • Kowalevicz, A.M.1    Ko, T.2    Hartl, I.3    Fujimoto, J.G.4    Pollnau, M.5    Salathé, R.P.6
  • 21
    • 20444429767 scopus 로고    scopus 로고
    • Ultrahigh-resolution optical coherence tomography with a fiber laser source at 1 μm
    • DOI 10.1364/OL.30.001171
    • H. Lim, Y. Jiang, Y. Wang, Y.-C. Huang, Z. Chen, and F.W. Wise Ultrahigh-resolution optical coherence tomography with a fiber laser source at 1 μm Opt. Lett. 30 2005 1171 1173 (Pubitemid 40795097)
    • (2005) Optics Letters , vol.30 , Issue.10 , pp. 1171-1173
    • Lim, H.1    Jiang, Y.2    Wang, Y.3    Huang, Y.-C.4    Chen, Z.5    Wise, F.W.6
  • 22
    • 2942726216 scopus 로고    scopus 로고
    • Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation
    • M. Wojtkowski, V.J. Srinivasan, T.H. Ko, J.G. Fujimoto, A. Kowalczyk, and J.S. Duker Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation Opt. Express 12 2004 2404 2422
    • (2004) Opt. Express , vol.12 , pp. 2404-2422
    • Wojtkowski, M.1    Srinivasan, V.J.2    Ko, T.H.3    Fujimoto, J.G.4    Kowalczyk, A.5    Duker, J.S.6
  • 23
    • 0037113144 scopus 로고    scopus 로고
    • Real-time dispersion compensation in scanning interferometry
    • E.D.J. Smith, A.V. Zvyagin, and D.D. Sampson Real-time dispersion compensation in scanning interferometry Opt. Lett. 27 2002 1998 2000
    • (2002) Opt. Lett. , vol.27 , pp. 1998-2000
    • Smith, E.D.J.1    Zvyagin, A.V.2    Sampson, D.D.3
  • 25
    • 0035846016 scopus 로고    scopus 로고
    • High resolution OCDR using 1.55 μm supercontinuum source and quadrature spectral detection
    • E.D.J. Smith, N. Wada, W. Chujo, and D.D. Sampson High resolution OCDR using 1.55 μm supercontinuum source and quadrature spectral detection Electron. Lett. 37 2001 1305 1307
    • (2001) Electron. Lett. , vol.37 , pp. 1305-1307
    • Smith, E.D.J.1    Wada, N.2    Chujo, W.3    Sampson, D.D.4
  • 26
    • 23144433829 scopus 로고    scopus 로고
    • Fiber-optic-bundle-based optical coherence tomography
    • T. Xie, D. Mukai, S. Guo, M. Brenner, and Z. Chen Fiber-optic-bundle- based optical coherence tomography Opt. Lett. 30 2005 1803 1805
    • (2005) Opt. Lett. , vol.30 , pp. 1803-1805
    • Xie, T.1    Mukai, D.2    Guo, S.3    Brenner, M.4    Chen, Z.5
  • 27
    • 0242440729 scopus 로고    scopus 로고
    • Endoscopic optical coherence tomography with a modified microelectromechanical systems mirror for detection of bladder cancers
    • T. Xie, H. Xie, G.K. Fedder, and Y. Pan Endoscopic optical coherence tomography with a modified microelectromechanical systems mirror for detection of bladder cancers Appl. Optics 42 2003 6422 6426
    • (2003) Appl. Optics , vol.42 , pp. 6422-6426
    • Xie, T.1    Xie, H.2    Fedder, G.K.3    Pan, Y.4
  • 29
    • 0034072983 scopus 로고    scopus 로고
    • High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography
    • B.E. Bouma, G.J. Tearney, C.C. Compton, and N.S. Nishioka High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography Gastrointest. Endosc. 51 2000 467 474
    • (2000) Gastrointest. Endosc. , vol.51 , pp. 467-474
    • Bouma, B.E.1    Tearney, G.J.2    Compton, C.C.3    Nishioka, N.S.4
  • 36
    • 51649122240 scopus 로고    scopus 로고
    • Real-time swept source optical coherence tomography imaging of the human airway using a microelectromechanical system endoscope and digital signal processor
    • J. Su, J. Zhang, L. Yu, H.G. Colt, M. Brenner, and Z. Chen Real-time swept source optical coherence tomography imaging of the human airway using a microelectromechanical system endoscope and digital signal processor J. Biomed. Opt. 13 2008 030506
    • (2008) J. Biomed. Opt. , vol.13 , pp. 030506
    • Su, J.1    Zhang, J.2    Yu, L.3    Colt, H.G.4    Brenner, M.5    Chen, Z.6
  • 38
    • 62449150935 scopus 로고    scopus 로고
    • Flexible miniature compound lens design for high-resolution optical coherence tomography balloon imaging catheter
    • H.L. Fu, Y. Leng, M.J. Cobb, K. Hsu, J.H. Hwang, and X. Lia Flexible miniature compound lens design for high-resolution optical coherence tomography balloon imaging catheter J. Biomed. Opt. 13 2008 060502
    • (2008) J. Biomed. Opt. , vol.13 , pp. 060502
    • Fu, H.L.1    Leng, Y.2    Cobb, M.J.3    Hsu, K.4    Hwang, J.H.5    Lia, X.6
  • 40
    • 0036098821 scopus 로고    scopus 로고
    • New optical technologies for earlier endoscopic diagnosis of premalignant gastrointestinal lesions
    • R.S. Dacosta, B.C. Wilson, and N.E. Marconi New optical technologies for earlier endoscopic diagnosis of premalignant gastrointestinal lesions J. Gastroenterol. Hepatol. 17 2002 S85 S104
    • (2002) J. Gastroenterol. Hepatol. , vol.17
    • Dacosta, R.S.1    Wilson, B.C.2    Marconi, N.E.3
  • 41
    • 38449089684 scopus 로고    scopus 로고
    • Detection and treatment of dysplasia in Barrett's esophagus: A pivotal challenge in translating biophotonics from bench to bedside
    • B.C. Wilson Detection and treatment of dysplasia in Barrett's esophagus: a pivotal challenge in translating biophotonics from bench to bedside J. Biomed. Opt. 12 2007 051401
    • (2007) J. Biomed. Opt. , vol.12 , pp. 051401
    • Wilson, B.C.1
  • 42
    • 0032467590 scopus 로고    scopus 로고
    • The Practice Parameters Committee of the American College of Gastroenterology, practice guidelines on the diagnosis, surveillance, and therapy of Barrett's esophagus
    • R.E. Sampliner The Practice Parameters Committee of the American College of Gastroenterology, practice guidelines on the diagnosis, surveillance, and therapy of Barrett's esophagus Am. J. Gastroenterol. 93 1998 1028 1032
    • (1998) Am. J. Gastroenterol. , vol.93 , pp. 1028-1032
    • Sampliner, R.E.1
  • 43
    • 0034010528 scopus 로고    scopus 로고
    • Feasibility of optical coherence tomography for high-resolution imaging of human gastrointestinal tract malignancies
    • C. Pitris, C. Jesser, S.A. Boppart, D. Stamper, M.E. Brezinski, and J.G. Fujimoto Feasibility of optical coherence tomography for high-resolution imaging of human gastrointestinal tract malignancies J. Gastroenterol. 35 2000 87 92
    • (2000) J. Gastroenterol. , vol.35 , pp. 87-92
    • Pitris, C.1    Jesser, C.2    Boppart, S.A.3    Stamper, D.4    Brezinski, M.E.5    Fujimoto, J.G.6
  • 46
    • 27844517375 scopus 로고    scopus 로고
    • Accuracy of endoscopic optical coherence tomography in the detection of dysplasia in Barrett's esophagus: A prospective, double-blinded study
    • G. Isenberg, M.V. Sivak Jr., A. Chak, R.C.K. Wong, J.E. Willis, B. Wolf, D.Y. Rowland, A. Das, and A. Rollins Accuracy of endoscopic optical coherence tomography in the detection of dysplasia in Barrett's esophagus: a prospective, double-blinded study Gastrointest. Endosc. 62 2005 825 831
    • (2005) Gastrointest. Endosc. , vol.62 , pp. 825-831
    • Isenberg, G.1    Sivak Jr., M.V.2    Chak, A.3    Wong, R.C.K.4    Willis, J.E.5    Wolf, B.6    Rowland, D.Y.7    Das, A.8    Rollins, A.9
  • 50
    • 32944474858 scopus 로고    scopus 로고
    • Optical coherence tomography: Real-time imaging of bronchial airways microstructure and detection of inflammatory/neoplastic morphologic changes
    • S.C. Whiteman, Y. Yang, D.G. van Pittius, M. Stephens, J. Parmer, and M.A. Spiteri Optical coherence tomography: real-time imaging of bronchial airways microstructure and detection of inflammatory/neoplastic morphologic changes Clin. Cancer Res. 12 2006 813 818
    • (2006) Clin. Cancer Res. , vol.12 , pp. 813-818
    • Whiteman, S.C.1    Yang, Y.2    Van Pittius, D.G.3    Stephens, M.4    Parmer, J.5    Spiteri, M.A.6
  • 53
    • 77953167050 scopus 로고    scopus 로고
    • Three-dimensional Fourier domain optical coherence tomography in vivo imaging of alveolar tissue in the intact thorax using the parietal pleura as a window
    • S. Meissner, L. Knels, C. Schnabel, T. Koch, and E. Koch Three-dimensional Fourier domain optical coherence tomography in vivo imaging of alveolar tissue in the intact thorax using the parietal pleura as a window J. Biomed. Opt. 15 2010 016030
    • (2010) J. Biomed. Opt. , vol.15 , pp. 016030
    • Meissner, S.1    Knels, L.2    Schnabel, C.3    Koch, T.4    Koch, E.5
  • 63
    • 1642587331 scopus 로고    scopus 로고
    • Intravascular optical coherence tomography opens a window onto coronary artery disease
    • J. Schmitt, D. Kolstad, and C. Petersen Intravascular optical coherence tomography opens a window onto coronary artery disease Opt. Photon. News 2004 20 25
    • (2004) Opt. Photon. News , pp. 20-25
    • Schmitt, J.1    Kolstad, D.2    Petersen, C.3
  • 65
    • 0032782052 scopus 로고    scopus 로고
    • High resolution in vivo intra-arterial imaging with optical coherence tomography
    • J.G. Fujimoto, S.A. Boppart, G.J. Tearney, B.E. Bouma, C. Pitris, and M.E. Brezinski High resolution in vivo intra-arterial imaging with optical coherence tomography Heart 82 1999 128 133 (Pubitemid 29362857)
    • (1999) Heart , vol.82 , Issue.2 , pp. 128-133
    • Fujimoto, J.G.1    Boppart, S.A.2    Tearney, G.J.3    Bouma, B.E.4    Pitris, C.5    Brezinski, M.E.6
  • 68
    • 0032714683 scopus 로고    scopus 로고
    • Optical properties of circulating human blood in the wavelength range 400-2500 nm
    • A. Roggan, M. Friebel, K. Dörschel, A. Hahn, and G. Müller Optical properties of circulating human blood in the wavelength range 400-2500 nm J. Biomed. Opt. 4 1999 36 46
    • (1999) J. Biomed. Opt. , vol.4 , pp. 36-46
    • Roggan, A.1    Friebel, M.2    Dörschel, K.3    Hahn, A.4    Müller, G.5
  • 69
    • 0035901618 scopus 로고    scopus 로고
    • Index matching to improve optical coherence tomography imaging through blood
    • M. Brezinski, K. Saunders, C. Jesser, X. Li, and J. Fujimoto Index matching to improve optical coherence tomography imaging through blood Circulation 103 2001 1999 2003
    • (2001) Circulation , vol.103 , pp. 1999-2003
    • Brezinski, M.1    Saunders, K.2    Jesser, C.3    Li, X.4    Fujimoto, J.5
  • 71
    • 0034019601 scopus 로고    scopus 로고
    • Lessons from sudden coronary death: A comprehensive morphological classification scheme for atherosclerotic lesions
    • R. Virmani, F.D. Kolodgie, A.P. Burke, A. Farb, and S.M. Schwartz Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions Arterioscl. Throm. Vas. Biol. 20 2000 1262 1275
    • (2000) Arterioscl. Throm. Vas. Biol. , vol.20 , pp. 1262-1275
    • Virmani, R.1    Kolodgie, F.D.2    Burke, A.P.3    Farb, A.4    Schwartz, S.M.5
  • 72
    • 0035902456 scopus 로고    scopus 로고
    • Current concepts of the pathogenesis of the acute coronary syndromes
    • P. Libby Current concepts of the pathogenesis of the acute coronary syndromes Circulation 104 2001 365 372
    • (2001) Circulation , vol.104 , pp. 365-372
    • Libby, P.1
  • 73
    • 0020639814 scopus 로고
    • Plaque rupture with severe pre-existing stenosis precipitating coronary thrombosis: Characteristics of coronary atherosclerotic plaques underlying fatal occlusive thrombi
    • E. Falk Plaque rupture with severe pre-existing stenosis precipitating coronary thrombosis: characteristics of coronary atherosclerotic plaques underlying fatal occlusive thrombi Brit. Heart J. 50 1983 127 134
    • (1983) Brit. Heart J. , vol.50 , pp. 127-134
    • Falk, E.1
  • 74
    • 0028059056 scopus 로고
    • Macrophage infiltration in acute coronary syndromes. Implications for plaque rupture
    • P.R. Moreno, E. Falk, I.F. Palacios, J.B. Newell, V. Fuster, and J.T. Fallon Macrophage infiltration in acute coronary syndromes. Implications for plaque rupture Circulation 90 1994 775 778
    • (1994) Circulation , vol.90 , pp. 775-778
    • Moreno, P.R.1    Falk, E.2    Palacios, I.F.3    Newell, J.B.4    Fuster, V.5    Fallon, J.T.6
  • 75
    • 0028836794 scopus 로고
    • Macrophage foam cells from experimental atheroma constitutively produce matrix-degrading proteinases
    • Z.S. Galis, G.K. Sukhova, R. Kranzhöfer, S. Clark, and P. Libby Macrophage foam cells from experimental atheroma constitutively produce matrix-degrading proteinases Proc. Natl. Acad. Sci. USA 92 1995 402 406
    • (1995) Proc. Natl. Acad. Sci. USA , vol.92 , pp. 402-406
    • Galis, Z.S.1    Sukhova, G.K.2    Kranzhöfer, R.3    Clark, S.4    Libby, P.5
  • 79
    • 78649905568 scopus 로고    scopus 로고
    • Imaging coronary atherosclerosis and vulnerable plaques with optical coherence tomography
    • G.J. Tearney, I.K. Jang, and B.E. Bouma Imaging coronary atherosclerosis and vulnerable plaques with optical coherence tomography W. Drexler, J.G. Fujimoto, Optical Coherence Tomography: Technology and Applications first ed. 2008 Springer Berlin 1083 1101
    • (2008) Optical Coherence Tomography: Technology and Applications , pp. 1083-1101
    • Tearney, G.J.1    Jang, I.K.2    Bouma, B.E.3
  • 81
    • 34547643517 scopus 로고    scopus 로고
    • Relationship between a systemic inflammatory marker, plaque inflammation, and plaque characteristics determined by intravascular optical coherence tomography
    • O.C. Raffel, G.J. Tearney, D.D. Gauthier, E.F. Halpern, B.E. Bouma, and I.-K. Jang Relationship between a systemic inflammatory marker, plaque inflammation, and plaque characteristics determined by intravascular optical coherence tomography Arterioscl. Throm. Vas. Biol. 27 2007 1820 1827
    • (2007) Arterioscl. Throm. Vas. Biol. , vol.27 , pp. 1820-1827
    • Raffel, O.C.1    Tearney, G.J.2    Gauthier, D.D.3    Halpern, E.F.4    Bouma, B.E.5    Jang, I.-K.6
  • 84
    • 33745156132 scopus 로고    scopus 로고
    • Paired-angle-rotation scanning optical coherence tomography forward-imaging probe
    • J. Wu, M. Conry, C. Gu, F. Wang, Z. Yaqoob, and C. Yang Paired-angle-rotation scanning optical coherence tomography forward-imaging probe Opt. Lett. 31 2006 1265 1267
    • (2006) Opt. Lett. , vol.31 , pp. 1265-1267
    • Wu, J.1    Conry, M.2    Gu, C.3    Wang, F.4    Yaqoob, Z.5    Yang, C.6
  • 85
    • 20644456680 scopus 로고    scopus 로고
    • A portable, low coherence interferometry based instrument for fine needle aspiration biopsy guidance
    • N.V. Iftimia, B.E. Bouma, M.B. Pitman, B. Goldberg, J. Bressner, and G.J. Tearney A portable, low coherence interferometry based instrument for fine needle aspiration biopsy guidance Rev. Sci. Instrum. 76 2005 064301
    • (2005) Rev. Sci. Instrum. , vol.76 , pp. 064301
    • Iftimia, N.V.1    Bouma, B.E.2    Pitman, M.B.3    Goldberg, B.4    Bressner, J.5    Tearney, G.J.6
  • 86
    • 61449233166 scopus 로고    scopus 로고
    • Spectral-domain low coherence interferometry/optical coherence tomography system for fine needle breast biopsy guidance
    • N.V. Iftimia, M. Mujat, T. Ustun, R.D. Ferguson, V. Danthu, and D.X. Hammer Spectral-domain low coherence interferometry/optical coherence tomography system for fine needle breast biopsy guidance Rev. Sci. Instrum. 80 2009 024302
    • (2009) Rev. Sci. Instrum. , vol.80 , pp. 024302
    • Iftimia, N.V.1    Mujat, M.2    Ustun, T.3    Ferguson, R.D.4    Danthu, V.5    Hammer, D.X.6
  • 87
    • 0037109477 scopus 로고    scopus 로고
    • Gradient-index fiber-optic microprobes for minimally invasive in vivo low-coherence interferometry
    • W.A. Reed, M.F. Yan, and M.J. Schnitzer Gradient-index fiber-optic microprobes for minimally invasive in vivo low-coherence interferometry Opt. Lett. 27 2002 1794 1796
    • (2002) Opt. Lett. , vol.27 , pp. 1794-1796
    • Reed, W.A.1    Yan, M.F.2    Schnitzer, M.J.3
  • 90
    • 35948999258 scopus 로고    scopus 로고
    • Graded-index fiber lens proposed for ultrasmall probes used in biomedical imaging
    • Y. Mao, S. Chang, S. Sherif, and C. Flueraru Graded-index fiber lens proposed for ultrasmall probes used in biomedical imaging Appl. Optics 46 2007 5887 5894
    • (2007) Appl. Optics , vol.46 , pp. 5887-5894
    • Mao, Y.1    Chang, S.2    Sherif, S.3    Flueraru, C.4
  • 91
  • 92
    • 22144485524 scopus 로고    scopus 로고
    • Optical coherence tomography imaging of the pancreas: A needle-based approach
    • J.H. Hwang, M.J. Cobb, M.B. Kimmey, and X. Li Optical coherence tomography imaging of the pancreas: a needle-based approach Clin. Gastroenterol. Hepatol. 3 2005 S49 S52
    • (2005) Clin. Gastroenterol. Hepatol. , vol.3
    • Hwang, J.H.1    Cobb, M.J.2    Kimmey, M.B.3    Li, X.4
  • 93
    • 57149104935 scopus 로고    scopus 로고
    • Interstitial Doppler optical coherence tomography as a local tumor necrosis predictor in photodynamic therapy of prostatic carcinoma: An in vivo study
    • B.A. Standish, K.K.C. Lee, X. Jin, A. Mariampillai, N.R. Munce, M.F.G. Wood, B.C. Wilson, I.A. Vitkin, and V.X.D. Yang Interstitial Doppler optical coherence tomography as a local tumor necrosis predictor in photodynamic therapy of prostatic carcinoma: an in vivo study Cancer Res. 68 2008 9987 9995
    • (2008) Cancer Res. , vol.68 , pp. 9987-9995
    • Standish, B.A.1    Lee, K.K.C.2    Jin, X.3    Mariampillai, A.4    Munce, N.R.5    Wood, M.F.G.6    Wilson, B.C.7    Vitkin, I.A.8    Yang, V.X.D.9
  • 95
    • 34247242745 scopus 로고    scopus 로고
    • Needle-based reflection refractometry of scattering samples using coherence-gated detection
    • A.M. Zysk, D.L. Marks, D.Y. Liu, and S.A. Boppart Needle-based reflection refractometry of scattering samples using coherence-gated detection Opt. Express 15 2007 4787 4794
    • (2007) Opt. Express , vol.15 , pp. 4787-4794
    • Zysk, A.M.1    Marks, D.L.2    Liu, D.Y.3    Boppart, S.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.