-
1
-
-
56649109474
-
Percutaneous techniques for minimally invasive posterior lumbar fusion
-
Harris EB, Massey P, Lawrence J, et al., Percutaneous techniques for minimally invasive posterior lumbar fusion. Neurosurg Focus 2008; 25 (2): E12.
-
(2008)
Neurosurg Focus
, vol.25
, Issue.2
, pp. 12
-
-
Harris, E.B.1
Massey, P.2
Lawrence, J.3
-
2
-
-
0036288337
-
Percutaneous pedicle screw fixation of the lumbar spine; Preliminary clinical results
-
Foley KT, Gupta SK,. Percutaneous pedicle screw fixation of the lumbar spine; preliminary clinical results. J Neurosurg 2002; 97 (1, suppl): 7-12.
-
(2002)
J Neurosurg
, vol.97
, Issue.1 SUPPL.
, pp. 7-12
-
-
Foley, K.T.1
Gupta, S.K.2
-
3
-
-
0002477863
-
Percutaneous pedicle screw fixation of the lumbar spine
-
Foley KT, Gupta SK, Justis JR, et al., Percutaneous pedicle screw fixation of the lumbar spine. Neurosurg Focus 2001; 10 (4): E10.
-
(2001)
Neurosurg Focus
, vol.10
, Issue.4
, pp. 10
-
-
Foley, K.T.1
Gupta, S.K.2
Justis, J.R.3
-
4
-
-
0032797248
-
Anatomic evaluation of two different techniques for the percutaneous insertion of pedicle screws in the lumbar spine
-
Wiesner L, Kothe R, Ruther W,. Anatomic evaluation of two different techniques for the percutaneous insertion of pedicle screws in the lumbar spine. Spine 1999; 24 (15): 1599-1603.
-
(1999)
Spine
, vol.24
, Issue.15
, pp. 1599-1603
-
-
Wiesner, L.1
Kothe, R.2
Ruther, W.3
-
5
-
-
33646596935
-
Placement of percutaneous pedicle screws without imaging guidance
-
Powers CJ, Podichetty VK, Isaacs RE,. Placement of percutaneous pedicle screws without imaging guidance. Neurosurg Focus 2006; 20 (3): E3.
-
(2006)
Neurosurg Focus
, vol.20
, Issue.3
, pp. 3
-
-
Powers, C.J.1
Podichetty, V.K.2
Isaacs, R.E.3
-
6
-
-
0036870784
-
Minimally invasive percutaneous posterior lumbar interbody fusion [see comment]
-
Khoo LT, Palmer S, Laich DT, et al., Minimally invasive percutaneous posterior lumbar interbody fusion [see comment]. Neurosurgery 2002; 51 (5, suppl): S166-161.
-
(2002)
Neurosurgery
, vol.51
, Issue.5 SUPPL.
, pp. 166-161
-
-
Khoo, L.T.1
Palmer, S.2
Laich, D.T.3
-
7
-
-
58749108335
-
Minimally invasive multilevel percutaneous correction and fusion for adult lumbar degenerative scoliosis; A technique and feasibility study
-
Anand N, Baron EM, Thaiyananthan G, et al., Minimally invasive multilevel percutaneous correction and fusion for adult lumbar degenerative scoliosis; a technique and feasibility study. J Spinal Disord Techn 2008; 21 (7): 459-467.
-
(2008)
J Spinal Disord Techn
, vol.21
, Issue.7
, pp. 459-467
-
-
Anand, N.1
Baron, E.M.2
Thaiyananthan, G.3
-
8
-
-
58849164909
-
Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion
-
Bindal RK, Glaze S, Ognoskie M, et al., Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion. J Neurosurg Spine 2008; 9 (6): 570-573.
-
(2008)
J Neurosurg Spine
, vol.9
, Issue.6
, pp. 570-573
-
-
Bindal, R.K.1
Glaze, S.2
Ognoskie, M.3
-
9
-
-
0032532750
-
Fatal cardiac tamponade associated with posterior spinal instrumentation. A case report
-
Heini P, Scholl E, Wyler D, et al., Fatal cardiac tamponade associated with posterior spinal instrumentation. A case report. Spine 1998; 23 (20): 2226-2230.
-
(1998)
Spine
, vol.23
, Issue.20
, pp. 2226-2230
-
-
Heini, P.1
Scholl, E.2
Wyler, D.3
-
10
-
-
26844549362
-
The mini-open transforaminal lumbar interbody fusion
-
discussion, 256-261.
-
Mummaneni PV, Rodts GE Jr,. The mini-open transforaminal lumbar interbody fusion. Neurosurgery 2005; 57 (4, suppl): 256-261; discussion, 256-261.
-
(2005)
Neurosurgery
, vol.57
, Issue.4 SUPPL.
, pp. 256-261
-
-
Mummaneni, P.V.1
Rodts, Jr.G.E.2
-
11
-
-
0037442352
-
Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance; A cadaver study
-
Mirza SK, Wiggins GC, Kuntz CT, et al., Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance; a cadaver study. Spine 2003; 28 (4): 402-413.
-
(2003)
Spine
, vol.28
, Issue.4
, pp. 402-413
-
-
Mirza, S.K.1
Wiggins, G.C.2
Kuntz, C.T.3
-
12
-
-
0042067885
-
Minimally invasive lumbar fusion [see comment]
-
Foley KT, Holly LT, Schwender JD,. Minimally invasive lumbar fusion [see comment]. Spine 2003; 28 (15, suppl): S26-35.
-
(2003)
Spine
, vol.28
, Issue.15 SUPPL.
, pp. 26-35
-
-
Foley, K.T.1
Holly, L.T.2
Schwender, J.D.3
-
13
-
-
34147196905
-
Percutaneous transforaminal lumbar interbody fusion for the treatment of degenerative lumbar instability [see comment]
-
discussion 212-203
-
Scheufler KM, Dohmen H, Vougioukas VI,. Percutaneous transforaminal lumbar interbody fusion for the treatment of degenerative lumbar instability [see comment]. Neurosurgery 2007; 60 (4): suppl 2): 203-212; discussion 212-203.
-
(2007)
Neurosurgery
, vol.60
, Issue.4 SUPPL. 2
, pp. 203-212
-
-
Scheufler, K.M.1
Dohmen, H.2
Vougioukas, V.I.3
-
14
-
-
58849121894
-
Clinical and radiographic comparison of mini-open transforaminal lumbar interbody fusion with open transforaminal lumbar interbody fusion in 42 patients with long-term follow-up
-
Dhall SS, Wang MY, Mummaneni PV,. Clinical and radiographic comparison of mini-open transforaminal lumbar interbody fusion with open transforaminal lumbar interbody fusion in 42 patients with long-term follow-up. J Neurosurg Spine 2008; 9 (6): 560-565.
-
(2008)
J Neurosurg Spine
, vol.9
, Issue.6
, pp. 560-565
-
-
Dhall, S.S.1
Wang, M.Y.2
Mummaneni, P.V.3
-
15
-
-
33644668944
-
Minimally invasive microendoscopy-assisted transforaminal lumbar interbody fusion with instrumentation
-
Isaacs RE, Podichetty VK, Santiago P, et al., Minimally invasive microendoscopy-assisted transforaminal lumbar interbody fusion with instrumentation. J Neurosurg Spine 2005; 3 (2): 98-105.
-
(2005)
J Neurosurg Spine
, vol.3
, Issue.2
, pp. 98-105
-
-
Isaacs, R.E.1
Podichetty, V.K.2
Santiago, P.3
-
16
-
-
33947134920
-
Comparison of one-level posterior lumbar interbody fusion performed with a minimally invasive approach or a traditional open approach
-
Park Y, Ha JW,. Comparison of one-level posterior lumbar interbody fusion performed with a minimally invasive approach or a traditional open approach. Spine 2007; 32 (5): 537-543.
-
(2007)
Spine
, vol.32
, Issue.5
, pp. 537-543
-
-
Park, Y.1
Ha, J.W.2
-
17
-
-
33745649897
-
Extreme lateral interbody fusion (XLIF); A novel surgical technique for anterior lumbar interbody fusion
-
Ozgur BM, Aryan HE, Pimenta L, et al., Extreme lateral interbody fusion (XLIF); a novel surgical technique for anterior lumbar interbody fusion. Spine J Offic J N Am Spine Soc 2006; 6 (4): 435-443.
-
(2006)
Spine J Offic J N Am Spine Soc
, vol.6
, Issue.4
, pp. 435-443
-
-
Ozgur, B.M.1
Aryan, H.E.2
Pimenta, L.3
-
18
-
-
33646095269
-
A novel minimally invasive presacral approach and instrumentation technique for anterior L5-S1 intervertebral discectomy and fusion; Technical description and case presentations
-
Marotta N, Cosar M, Pimenta L, et al., A novel minimally invasive presacral approach and instrumentation technique for anterior L5-S1 intervertebral discectomy and fusion; technical description and case presentations. Neurosurg Focus 2006; 20 (1): E9.
-
(2006)
Neurosurg Focus
, vol.20
, Issue.1
, pp. 9
-
-
Marotta, N.1
Cosar, M.2
Pimenta, L.3
-
19
-
-
33646820055
-
Use of minimally invasive surgical techniques in the management of thoracolumbar trauma; Current concepts
-
discussion, S104.
-
Rampersaud YR, Annand N, Dekutoski MB,. Use of minimally invasive surgical techniques in the management of thoracolumbar trauma; current concepts. Spine 2006; 31 (11, suppl): S96-102; discussion, S104.
-
(2006)
Spine
, vol.31
, Issue.11 SUPPL.
, pp. 96-102
-
-
Rampersaud, Y.R.1
Annand, N.2
Dekutoski, M.B.3
-
20
-
-
0034099254
-
Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine
-
Wiesner L, Kothe R, Schulitz KP, et al., Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine. Spine 2000; 25 (5): 615-621.
-
(2000)
Spine
, vol.25
, Issue.5
, pp. 615-621
-
-
Wiesner, L.1
Kothe, R.2
Schulitz, K.P.3
-
21
-
-
34248550738
-
Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization
-
Schizas C, Michel J, Kosmopoulos V, et al., Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization. Eur Spine J 2007; 16 (5): 613-617.
-
(2007)
Eur Spine J
, vol.16
, Issue.5
, pp. 613-617
-
-
Schizas, C.1
Michel, J.2
Kosmopoulos, V.3
-
22
-
-
0028292805
-
Percutaneous diagnostic stabilization for low back pain. Correlation with results after fusion operations
-
Jeanneret B, Jovanovic M, Magerl F,. Percutaneous diagnostic stabilization for low back pain. Correlation with results after fusion operations. Clin Orthop Relat Res 1994; 304: 130-138.
-
(1994)
Clin Orthop Relat Res
, vol.304
, pp. 130-138
-
-
Jeanneret, B.1
Jovanovic, M.2
Magerl, F.3
-
23
-
-
0000393998
-
Posterior percutaneous spine instrumentation
-
Lowery GL, Kulkarni SS,. Posterior percutaneous spine instrumentation. Eur Spine J 2000; 9 (suppl 1): S126-130.
-
(2000)
Eur Spine J
, vol.9
, Issue.SUPPL. 1
, pp. 126-130
-
-
Lowery, G.L.1
Kulkarni, S.S.2
-
24
-
-
8644221397
-
Minimally invasive removal or revision of lumbar spinal fixation
-
Salerni AA,. Minimally invasive removal or revision of lumbar spinal fixation. Spine J Offic J N Am Spine Soc 2004; 4 (6): 701-705.
-
(2004)
Spine J Offic J N Am Spine Soc
, vol.4
, Issue.6
, pp. 701-705
-
-
Salerni, A.A.1
-
25
-
-
21344451136
-
Minimally invasive transforaminal lumbar interbody fusion (TLIF); Technical feasibility and initial results
-
Schwender JD, Holly LT, Rouben DP, et al., Minimally invasive transforaminal lumbar interbody fusion (TLIF); technical feasibility and initial results. J Spinal Disord Techn 2005; 18:(suppl): S1-6.
-
(2005)
J Spinal Disord Techn
, vol.18
, Issue.SUPPL.
, pp. 1-6
-
-
Schwender, J.D.1
Holly, L.T.2
Rouben, D.P.3
-
26
-
-
0343526789
-
Radiation exposure during fluoroscopically assisted pedicle screw insertion in the lumbar spine
-
Jones DP, Robertson PA, Lunt B, et al., Radiation exposure during fluoroscopically assisted pedicle screw insertion in the lumbar spine. Spine 2000; 25 (12): 1538-1541.
-
(2000)
Spine
, vol.25
, Issue.12
, pp. 1538-1541
-
-
Jones, D.P.1
Robertson, P.A.2
Lunt, B.3
-
27
-
-
0034667336
-
Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion
-
Rampersaud YR, Foley KT, Shen AC, et al., Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine 2000; 25 (20): 2637-2645.
-
(2000)
Spine
, vol.25
, Issue.20
, pp. 2637-2645
-
-
Rampersaud, Y.R.1
Foley, K.T.2
Shen, A.C.3
-
28
-
-
33749519625
-
Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis; Is fluoroscopy safe?
-
Ul Haque M, Shufflebarger HL, O'Brien M, et al., Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis; is fluoroscopy safe? Spine 2006; 31 (21): 2516-2520.
-
(2006)
Spine
, vol.31
, Issue.21
, pp. 2516-2520
-
-
Ul Haque, M.1
Shufflebarger, H.L.2
O'Brien, M.3
-
29
-
-
20444435057
-
Extracorporeal single dose and radiographic dosage in image-controlled and fluoroscopic navigated pedicle screw implantation
-
Linhardt O, Perlick L, Luring C, et al., Extracorporeal single dose and radiographic dosage in image-controlled and fluoroscopic navigated pedicle screw implantation. Zeitschr Orthop Grenzgebiete 2005; 143 (2): 175-179.
-
(2005)
Zeitschr Orthop Grenzgebiete
, vol.143
, Issue.2
, pp. 175-179
-
-
Linhardt, O.1
Perlick, L.2
Luring, C.3
-
30
-
-
3242676907
-
Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion
-
Perisinakis K, Theocharopoulos N, Damilakis J, et al., Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion. Spine 2004; 29 (14): 1555-1560.
-
(2004)
Spine
, vol.29
, Issue.14
, pp. 1555-1560
-
-
Perisinakis, K.1
Theocharopoulos, N.2
Damilakis, J.3
-
31
-
-
0041333802
-
Electromagnetic field-based image-guided spine surgery, part one; Results of a cadaveric study evaluating lumbar pedicle screw placement
-
Sagi HC, Manos R, Benz R, et al., Electromagnetic field-based image-guided spine surgery, part one; results of a cadaveric study evaluating lumbar pedicle screw placement. Spine 2003; 28 (17): 2013-2018.
-
(2003)
Spine
, vol.28
, Issue.17
, pp. 2013-2018
-
-
Sagi, H.C.1
Manos, R.2
Benz, R.3
-
32
-
-
2142643168
-
Electromagnetic field-based image-guided spine surgery, part two; Results of a cadaveric study evaluating thoracic pedicle screw placement
-
Sagi HC, Manos R, Park SC, et al., Electromagnetic field-based image-guided spine surgery, part two; results of a cadaveric study evaluating thoracic pedicle screw placement. Spine 2003; 28 (17): E351-354.
-
(2003)
Spine
, vol.28
, Issue.17
, pp. 351-354
-
-
Sagi, H.C.1
Manos, R.2
Park, S.C.3
-
33
-
-
0033562611
-
Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery
-
discussion, 983.
-
Slomczykowski M, Roberto M, Schneeberger P, et al., Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery. Spine 1999; 24 (10): 975-982; discussion, 983.
-
(1999)
Spine
, vol.24
, Issue.10
, pp. 975-982
-
-
Slomczykowski, M.1
Roberto, M.2
Schneeberger, P.3
-
34
-
-
33644660012
-
Fluoroscopic radiation exposure of the kyphoplasty patient
-
Boszczyk BM, Bierschneider M, Panzer S, et al., Fluoroscopic radiation exposure of the kyphoplasty patient. Eur Spine J 2006; 15 (3): 347-355.
-
(2006)
Eur Spine J
, vol.15
, Issue.3
, pp. 347-355
-
-
Boszczyk, B.M.1
Bierschneider, M.2
Panzer, S.3
-
35
-
-
41949113413
-
Radiation exposure to the surgeon and the patient during kyphoplasty
-
Mroz TE, Yamashita T, Davros WJ, et al., Radiation exposure to the surgeon and the patient during kyphoplasty. J Spinal Disord Techn 2008; 21 (2): 96-100.
-
(2008)
J Spinal Disord Techn
, vol.21
, Issue.2
, pp. 96-100
-
-
Mroz, T.E.1
Yamashita, T.2
Davros, W.J.3
-
36
-
-
64749105814
-
Intraosseous ultrasound in the placement of pedicle screws in the lumbar spine
-
Kantelhardt SR, Bock CH, Larsen J, et al., Intraosseous ultrasound in the placement of pedicle screws in the lumbar spine. Spine 2009; 34 (4): 400-407.
-
(2009)
Spine
, vol.34
, Issue.4
, pp. 400-407
-
-
Kantelhardt, S.R.1
Bock, C.H.2
Larsen, J.3
-
37
-
-
77953293554
-
A-mode ultrasound guidance for pedicle screw advancement in ovine vertebral bodies
-
Raphael DT, Chang JH, Zhang YP, et al., A-mode ultrasound guidance for pedicle screw advancement in ovine vertebral bodies. Spine J Offic J N Am Spine Soc 2010; 10 (5): 422-432.
-
(2010)
Spine J Offic J N Am Spine Soc
, vol.10
, Issue.5
, pp. 422-432
-
-
Raphael, D.T.1
Chang, J.H.2
Zhang, Y.P.3
-
38
-
-
18144414312
-
Use of intraoperative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement; Case report and review of the literature
-
Acosta FL Jr, Thompson TL, Campbell S, et al., Use of intraoperative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement; case report and review of the literature. Spine J Offic J N Am Spine Soc 2005; 5 (3): 339-343.
-
(2005)
Spine J Offic J N Am Spine Soc
, vol.5
, Issue.3
, pp. 339-343
-
-
Acosta, Jr.F.L.1
Thompson, T.L.2
Campbell, S.3
-
39
-
-
32944477651
-
Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques
-
Villavicencio AT, Burneikiene S, Bulsara KR, et al., Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques. J Spinal Disord Techn 2005; 18 (4): 369-375.
-
(2005)
J Spinal Disord Techn
, vol.18
, Issue.4
, pp. 369-375
-
-
Villavicencio, A.T.1
Burneikiene, S.2
Bulsara, K.R.3
-
40
-
-
64749091332
-
Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system; First experiences and accuracy of screw placement
-
Pechlivanis I, Kiriyanthan G, Engelhardt M, et al., Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system; first experiences and accuracy of screw placement. Spine 2009; 34 (4): 392-398.
-
(2009)
Spine
, vol.34
, Issue.4
, pp. 392-398
-
-
Pechlivanis, I.1
Kiriyanthan, G.2
Engelhardt, M.3
-
41
-
-
68049093092
-
Timing of vertebral registration in three-dimensional, fluoroscopy-based, image-guided spinal surgery
-
Nottmeier EW, Crosby T,. Timing of vertebral registration in three-dimensional, fluoroscopy-based, image-guided spinal surgery. J Spinal Disord Techn 2009; 22 (5): 358-360.
-
(2009)
J Spinal Disord Techn
, vol.22
, Issue.5
, pp. 358-360
-
-
Nottmeier, E.W.1
Crosby, T.2
|