메뉴 건너뛰기




Volumn 95 B, Issue 2, 2010, Pages 298-307

Evaluating the suitability of highly cross-linked and remelted materials for use in posterior stabilized knees

Author keywords

fatigue strength; highly cross linked and remelted UHMWPE; impact toughness; oxidation; tibial post

Indexed keywords

FATIGUE FAILURES; FATIGUE STRENGTH; HIGH MECHANICAL PROPERTIES; IMPACT TOUGHNESS; KNEE ARTHROPLASTY; NONUNIFORM; OXIDATION LEVEL; TIBIAL INSERTS; TIBIAL POST; UHMW-PE;

EID: 78649660009     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.31714     Document Type: Article
Times cited : (16)

References (41)
  • 2
    • 37349126919 scopus 로고    scopus 로고
    • Outcomes of posterior stabilized total knee arthroplasty
    • Orozco F, Hozack WJ,. Outcomes of posterior stabilized total knee arthroplasty. Current Orthop Practice 2008; 19: 160-164.
    • (2008) Current Orthop Practice , vol.19 , pp. 160-164
    • Orozco, F.1    Hozack, W.J.2
  • 3
    • 0036397805 scopus 로고    scopus 로고
    • Mechanism of anterior impingement damage in total knee arthroplasty
    • Banks SA, Harman MK, Hodge,. Mechanism of anterior impingement damage in total knee arthroplasty. J Bone Joint Surg Am 2002; 2 (Suppl 84A): 37-42.
    • (2002) J Bone Joint Surg Am , vol.2 , Issue.SUPPL. 84A , pp. 37-42
    • Banks, S.A.1    Harman, M.K.2    Hodge3
  • 5
    • 0041419845 scopus 로고    scopus 로고
    • Fracture of the central polyethylene tibial spine in posterior stabilized total knee arthroplasty
    • Hendel D, Garti A, Weisbort M,. Fracture of the central polyethylene tibial spine in posterior stabilized total knee arthroplasty. J Arthroplasty 2003; 18: 672-674.
    • (2003) J Arthroplasty , vol.18 , pp. 672-674
    • Hendel, D.1    Garti, A.2    Weisbort, M.3
  • 8
    • 16644390256 scopus 로고    scopus 로고
    • Fracture of the polyethylene tibial post in a nexgen posterior-stabilized knee prosthesis
    • Chiu YS, Chen WM, Huang CK, Chiang CC, Chen TH,. Fracture of the polyethylene tibial post in a nexgen posterior-stabilized knee prosthesis. J Arthroplasty 2004; 19: 1045-1049.
    • (2004) J Arthroplasty , vol.19 , pp. 1045-1049
    • Chiu, Y.S.1    Chen, W.M.2    Huang, C.K.3    Chiang, C.C.4    Chen, T.H.5
  • 9
    • 3342936437 scopus 로고    scopus 로고
    • Polyethylene post failure in posterior-stabilized total knee arthroplasty
    • Clarke HD, Math KR, Scuderi GR,. Polyethylene post failure in posterior-stabilized total knee arthroplasty. J Arthroplasty 2004; 19: 652-657.
    • (2004) J Arthroplasty , vol.19 , pp. 652-657
    • Clarke, H.D.1    Math, K.R.2    Scuderi, G.R.3
  • 10
    • 4644286314 scopus 로고    scopus 로고
    • Secondary knee instability caused by fracture of the stabilizing insert in a dual-articular total knee arthroplasty
    • Boesen MP, Jensen TT, Husted H,. Secondary knee instability caused by fracture of the stabilizing insert in a dual-articular total knee arthroplasty. J Arthroplasty 2004; 19: 941-943.
    • (2004) J Arthroplasty , vol.19 , pp. 941-943
    • Boesen, M.P.1    Jensen, T.T.2    Husted, H.3
  • 11
    • 0033818985 scopus 로고    scopus 로고
    • Fracture of the polyethylene post in posterior stabilized (Insall Burnstein II) total knee arthroplasty
    • Mestha P, Shenava Y, D'Arcy JC,. Fracture of the polyethylene post in posterior stabilized (Insall Burnstein II) total knee arthroplasty. J Arthroplasty 2000; 15: 814-815.
    • (2000) J Arthroplasty , vol.15 , pp. 814-815
    • Mestha, P.1    Shenava, Y.2    D'Arcy, J.C.3
  • 12
    • 0033623094 scopus 로고    scopus 로고
    • Fracture of posterior-stabilized tibial insert in a genesis knee prosthesis
    • Mariconda M, Lotti G, Milano C,. Fracture of posterior-stabilized tibial insert in a genesis knee prosthesis. J Arthroplasty 2000; 15: 529-530.
    • (2000) J Arthroplasty , vol.15 , pp. 529-530
    • Mariconda, M.1    Lotti, G.2    Milano, C.3
  • 13
    • 0027496958 scopus 로고
    • Breakage of a total condylar III knee prothesis
    • McPherson EJ, Vince KG,. Breakage of a total condylar III knee prothesis. J Arthroplasty 1993; 8: 561-563.
    • (1993) J Arthroplasty , vol.8 , pp. 561-563
    • McPherson, E.J.1    Vince, K.G.2
  • 14
    • 0141958863 scopus 로고    scopus 로고
    • Fracture of the polyethylene tibial post in a posterior cruciate-substituting total knee arthroplasty mimicking patellar clunk syndrome
    • Mauerhan DR,. Fracture of the polyethylene tibial post in a posterior cruciate-substituting total knee arthroplasty mimicking patellar clunk syndrome. J Arthroplasty 2003; 18: 942-945.
    • (2003) J Arthroplasty , vol.18 , pp. 942-945
    • Mauerhan, D.R.1
  • 15
    • 33947573515 scopus 로고    scopus 로고
    • Failure of a metal-reinforced tibial post in total knee arthroplasty
    • Bal SB, Greenberg D,. Failure of a metal-reinforced tibial post in total knee arthroplasty. J Arthroplasty 2007; 28: 464-467.
    • (2007) J Arthroplasty , vol.28 , pp. 464-467
    • Bal, S.B.1    Greenberg, D.2
  • 16
    • 27744431660 scopus 로고    scopus 로고
    • Fracture of the polyethylene tibial post in a posterior stabilized PFC total knee arthroplasty
    • Sands KC, Silver JW,. Fracture of the polyethylene tibial post in a posterior stabilized PFC total knee arthroplasty. Orthopedics 2005; 28: 1203-1204.
    • (2005) Orthopedics , vol.28 , pp. 1203-1204
    • Sands, K.C.1    Silver, J.W.2
  • 17
    • 48949118903 scopus 로고    scopus 로고
    • Tibial post failures in a condylar posterior cruciate substituting total knee arthroplasty
    • Bal SB, Greenberg D, Li S, Mauerhan DR, Schultz L, Cherry K,. Tibial post failures in a condylar posterior cruciate substituting total knee arthroplasty. J Arthroplasty 2008; 23: 650-655.
    • (2008) J Arthroplasty , vol.23 , pp. 650-655
    • Bal, S.B.1    Greenberg, D.2    Li, S.3    Mauerhan, D.R.4    Schultz, L.5    Cherry, K.6
  • 18
    • 65349183540 scopus 로고    scopus 로고
    • Fracture of a second-generation highly cross-linked UHMWPE tibial post in a posterior-stabilized scorpio knee system
    • Jung KA, Lee SC, Hwang SH, Kim SM,. Fracture of a second-generation highly cross-linked UHMWPE tibial post in a posterior-stabilized scorpio knee system. Orthopedics 2008; 31: 1137-1139.
    • (2008) Orthopedics , vol.31 , pp. 1137-1139
    • Jung, K.A.1    Lee, S.C.2    Hwang, S.H.3    Kim, S.M.4
  • 19
    • 73349127175 scopus 로고    scopus 로고
    • Fractured polyethylene post in a posterior stabilized knee prosthesis presenting as a floating palpable mass
    • Jung KA, Lee SC, Hwang SH, Kim SM,. Fractured polyethylene post in a posterior stabilized knee prosthesis presenting as a floating palpable mass. J Knee Surg 2009; 22: 374-376.
    • (2009) J Knee Surg , vol.22 , pp. 374-376
    • Jung, K.A.1    Lee, S.C.2    Hwang, S.H.3    Kim, S.M.4
  • 20
    • 0034772326 scopus 로고    scopus 로고
    • New Polys for Old: Contribution or Caveat?
    • Greenwald SA, Bauer TW, Ries MD,. "New Polys for Old: Contribution or Caveat?". J Bone Joint Surg Am 2001; 2 (Suppl 83A): 27-31.
    • (2001) J Bone Joint Surg Am , vol.2 , Issue.SUPPL. 83A , pp. 27-31
    • Greenwald, S.A.1    Bauer, T.W.2    Ries, M.D.3
  • 21
  • 23
    • 84941911350 scopus 로고    scopus 로고
    • San Diego: Elviser Academic Press.
    • Kurtz SM,. The UHMWPE Handbook. San Diego: Elviser Academic Press; 2004.
    • (2004) The UHMWPE Handbook
    • Kurtz, S.M.1
  • 25
    • 28444433471 scopus 로고    scopus 로고
    • Fatigue crack propagation resistance of virgin and highly crosslinked thermally treated ultra-high molecular weight polyethylene
    • Gencur SJ, Rimnac CM, Kurtz SM,. Fatigue crack propagation resistance of virgin and highly crosslinked thermally treated ultra-high molecular weight polyethylene. Biomaterials 2006; 27: 1550-1557.
    • (2006) Biomaterials , vol.27 , pp. 1550-1557
    • Gencur, S.J.1    Rimnac, C.M.2    Kurtz, S.M.3
  • 26
    • 0141447819 scopus 로고    scopus 로고
    • The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene
    • Baker DA, Bellare A, Pruitt L,. The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene. J Biomed Mater Res A 2003; 66: 146-154.
    • (2003) J Biomed Mater Res A , vol.66 , pp. 146-154
    • Baker, D.A.1    Bellare, A.2    Pruitt, L.3
  • 27
    • 0033567865 scopus 로고    scopus 로고
    • Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene
    • Baker DA, Hastings RS, Pruitt L,. Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene. J Biomed Mater Res 1999; 46: 573-581.
    • (1999) J Biomed Mater Res , vol.46 , pp. 573-581
    • Baker, D.A.1    Hastings, R.S.2    Pruitt, L.3
  • 34
    • 67650822628 scopus 로고    scopus 로고
    • Evaluation of sequentially crosslinked ultra-high molecular weight polyethylene
    • Morrison ML, Jani S,. Evaluation of sequentially crosslinked ultra-high molecular weight polyethylene. J Biomed Mater Res Part B: Appl Biomater B 2009; 90: 87-100.
    • (2009) J Biomed Mater Res Part B: Appl Biomater B , vol.90 , pp. 87-100
    • Morrison, M.L.1    Jani, S.2
  • 35
    • 0036381521 scopus 로고    scopus 로고
    • Gamma irradiation alters fatigue-crack behavior and fracture toughness in 1900H and GUR 1050 UHMWPE
    • Cole JC, Lemons JE, Eberhardt AW,. Gamma irradiation alters fatigue-crack behavior and fracture toughness in 1900H and GUR 1050 UHMWPE. J Biomed Mater Res (Appl Biomater) 2002; 63: 559-566.
    • (2002) J Biomed Mater Res (Appl Biomater) , vol.63 , pp. 559-566
    • Cole, J.C.1    Lemons, J.E.2    Eberhardt, A.W.3
  • 36
    • 0038016670 scopus 로고    scopus 로고
    • Failure micromechanisms during uniaxial tensile fracture of conventional and highly crosslinked ultra-high molecular weight polyethylenes used in total joint replacements
    • Gencur SJ, Rimnac CM, Kurtz SM,. Failure micromechanisms during uniaxial tensile fracture of conventional and highly crosslinked ultra-high molecular weight polyethylenes used in total joint replacements. Biomaterials 2003; 24: 3947-3954.
    • (2003) Biomaterials , vol.24 , pp. 3947-3954
    • Gencur, S.J.1    Rimnac, C.M.2    Kurtz, S.M.3
  • 37
    • 26944432688 scopus 로고    scopus 로고
    • Mechanisms of decrease in fatigue crack propagation resistance in irradiated and melted UHMWPE
    • Oral E, Malhi AS, Muratoglu OK,. Mechanisms of decrease in fatigue crack propagation resistance in irradiated and melted UHMWPE. Biomaterials 2006; 27: 917-925.
    • (2006) Biomaterials , vol.27 , pp. 917-925
    • Oral, E.1    Malhi, A.S.2    Muratoglu, O.K.3
  • 38
    • 0035095010 scopus 로고    scopus 로고
    • Fatigue characteristics of ultra high molecular weight polyethylene with different molecular weight for implant material
    • Niinomi M, Wang L, Enjitsu T, Fukunaga K,. Fatigue characteristics of ultra high molecular weight polyethylene with different molecular weight for implant material. J Mater Sci-Mater M 2001; 12: 267-272.
    • (2001) J Mater Sci-Mater M , vol.12 , pp. 267-272
    • Niinomi, M.1    Wang, L.2    Enjitsu, T.3    Fukunaga, K.4
  • 39
    • 10044242360 scopus 로고    scopus 로고
    • γ-Irradiation of ultrahigh-molecular-weight polyethylene: Electron paramagnetic resonance and nuclear magnetic resonance spectroscopy and imaging studies of the mechanism of subsurface oxidation
    • Alam TM, Celina M, Collier JP, Currier BH, Currier JH, Jackson SK, Kuethe DO, Timmins GS,. γ-Irradiation of ultrahigh-molecular-weight polyethylene: electron paramagnetic resonance and nuclear magnetic resonance spectroscopy and imaging studies of the mechanism of subsurface oxidation. J Polym Sci Part A: Polym Chem 2004; 42: 5929-5941.
    • (2004) J Polym Sci Part A: Polym Chem , vol.42 , pp. 5929-5941
    • Alam, T.M.1    Celina, M.2    Collier, J.P.3    Currier, B.H.4    Currier, J.H.5    Jackson, S.K.6    Kuethe, D.O.7    Timmins, G.S.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.