메뉴 건너뛰기




Volumn 64, Issue 6, 2010, Pages 1652-1657

RF coil considerations for short-T2 MRI

Author keywords

low proton; MRI; RF coil; short T2; uTE

Indexed keywords

MAGNETIC RESONANCE IMAGING;

EID: 78649605913     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22558     Document Type: Article
Times cited : (37)

References (19)
  • 1
    • 0037236412 scopus 로고    scopus 로고
    • Magnetic resonance imaging of short T-2 components in tissue
    • Gatehouse PD, Bydder GM,. Magnetic resonance imaging of short T-2 components in tissue. Clin Radiol 2003; 58: 1-19.
    • (2003) Clin Radiol , vol.58 , pp. 1-19
    • Gatehouse, P.D.1    Bydder, G.M.2
  • 3
    • 0037925188 scopus 로고    scopus 로고
    • Density of organic matrix of native mineralized bone measured by water- and fat-suppressed proton projection MRI
    • Wu YT, Ackerman JL, Chesler DA, Graham L, Wang Y, Glimcher MJ,. Density of organic matrix of native mineralized bone measured by water- and fat-suppressed proton projection MRI. Magn Reson Med 2003; 50: 59-68.
    • (2003) Magn Reson Med , vol.50 , pp. 59-68
    • Wu, Y.T.1    Ackerman, J.L.2    Chesler, D.A.3    Graham, L.4    Wang, Y.5    Glimcher, M.J.6
  • 4
    • 41849101676 scopus 로고    scopus 로고
    • Multinuclear NMR investigation of probe construction materials at 9.4T
    • Marjanska M, Waks M, Snyder CJ, Vaughan JT,. Multinuclear NMR investigation of probe construction materials at 9.4T. Magn Reson Med 2008; 59: 936-938.
    • (2008) Magn Reson Med , vol.59 , pp. 936-938
    • Marjanska, M.1    Waks, M.2    Snyder, C.J.3    Vaughan, J.T.4
  • 6
    • 0021850318 scopus 로고
    • High-resolution NMR imaging in solids
    • Emid S, Creyghton JHN,. High-resolution NMR imaging in solids. Physica B 1985; 128: 81-83.
    • (1985) Physica B , vol.128 , pp. 81-83
    • Emid, S.1    Creyghton, J.H.N.2
  • 8
    • 0042995331 scopus 로고    scopus 로고
    • Impurity proton NMR signals from common "proton-free" laboratory materials
    • Bachman HN, Silvera IF,. Impurity proton NMR signals from common "proton-free" laboratory materials. J Magn Reson 2003; 162: 417-422.
    • (2003) J Magn Reson , vol.162 , pp. 417-422
    • Bachman, H.N.1    Silvera, I.F.2
  • 11
    • 0038445759 scopus 로고    scopus 로고
    • Bone tissue and porous media: Common features and differences studied by NMR relaxation
    • Fantazzini P, Brown RJS, Borgia GC,. Bone tissue and porous media: common features and differences studied by NMR relaxation. Magn Reson Imaging 2003; 21: 227-234.
    • (2003) Magn Reson Imaging , vol.21 , pp. 227-234
    • Fantazzini, P.1    Brown, R.J.S.2    Borgia, G.C.3
  • 12
    • 33751368661 scopus 로고    scopus 로고
    • Clinical ultrashort echo time imaging of bone and other connective tissues
    • Robson MD, Bydder GM,. Clinical ultrashort echo time imaging of bone and other connective tissues. NMR Biomed 2006; 19: 765-780.
    • (2006) NMR Biomed , vol.19 , pp. 765-780
    • Robson, M.D.1    Bydder, G.M.2
  • 13
  • 15
    • 40049083116 scopus 로고    scopus 로고
    • Two-dimensional ultrashort echo time imaging using a spiral trajectory
    • Du J, Bydder M, Takahashi AM, Chung CB,. Two-dimensional ultrashort echo time imaging using a spiral trajectory. Magn Reson Imaging 2008; 26: 304-312.
    • (2008) Magn Reson Imaging , vol.26 , pp. 304-312
    • Du, J.1    Bydder, M.2    Takahashi, A.M.3    Chung, C.B.4
  • 16
    • 77956378711 scopus 로고    scopus 로고
    • Characterization of 1H NMR signal in human cortical bone for magnetic resonance imaging
    • 2010 [Epub ahead of print]
    • Horch RA, Nyman JS, Gochberg DF, Dortch RD, Does MD,. Characterization of 1H NMR signal in human cortical bone for magnetic resonance imaging. Magn Reson Med 2010 [Epub ahead of print].
    • Magn Reson Med
    • Horch, R.A.1    Nyman, J.S.2    Gochberg, D.F.3    Dortch, R.D.4    Does, M.D.5
  • 17
    • 0032214987 scopus 로고    scopus 로고
    • Three-dimensional magnetic resonance imaging of rigid polymeric materials using single-point ramped imaging with T-1 enhancement (SPRITE)
    • Kennedy CB, Balcom BJ, Mastikhin IV,. Three-dimensional magnetic resonance imaging of rigid polymeric materials using single-point ramped imaging with T-1 enhancement (SPRITE). Can J Chem 1998; 76: 1753-1765.
    • (1998) Can J Chem , vol.76 , pp. 1753-1765
    • Kennedy, C.B.1    Balcom, B.J.2    Mastikhin, I.V.3
  • 18
    • 0027337730 scopus 로고
    • MRI and determination of T1 and T2 of solid polymers using a 1.5 T whole-body imager
    • Widmaier S, Jung W-I, Pfeffer K, Pfeffer M, Lutz O,. MRI and determination of T1 and T2 of solid polymers using a 1.5 T whole-body imager. Magn Reson Imaging 1993; 11: 733-737.
    • (1993) Magn Reson Imaging , vol.11 , pp. 733-737
    • Widmaier, S.1    Jung, W.-I.2    Pfeffer, K.3    Pfeffer, M.4    Lutz, O.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.