-
1
-
-
0022598272
-
Use of frequency-modulated radio frequency pulses in MR imaging experiments
-
Kunz D.W. Use of frequency-modulated radio frequency pulses in MR imaging experiments. Magn. Reson. Med. 3(3):1986;377-384.
-
(1986)
Magn. Reson. Med.
, vol.3
, Issue.3
, pp. 377-384
-
-
Kunz, D.W.1
-
2
-
-
0031758092
-
Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging
-
Le Roux P., Gilles R.J., McKinnon G.C., Carlier P.G. Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging. J. Magn. Reson. Imaging. 8(5):1998;1022-1032.
-
(1998)
J. Magn. Reson. Imaging
, vol.8
, Issue.5
, pp. 1022-1032
-
-
Le Roux, P.1
Gilles, R.J.2
Mckinnon, G.C.3
Carlier, P.G.4
-
3
-
-
0347307122
-
-
United States Patent 4,707,659
-
D.W. Kunz, H.H. Tuithof, J.H.M. Cuppen, Method and device for determining an NMR distribution in a region of a body, United States Patent 4,707,659 (1987).
-
(1987)
Method and Device for Determining an NMR Distribution in a Region of a Body
-
-
Kunz, D.W.1
Tuithof, H.H.2
Cuppen, J.H.M.3
-
4
-
-
0033970816
-
Very selective suppression pulses for clinical MRSI studies of brain and prostate cancer
-
Tran T.K.C., Vigneron D.B., Sailasuta N., Tropp J., Le Roux P., Kurhanewicz J., Nelson S., Hurd R. Very selective suppression pulses for clinical MRSI studies of brain and prostate cancer. Magn. Reson. Med. 43(1):2000;23-33.
-
(2000)
Magn. Reson. Med.
, vol.43
, Issue.1
, pp. 23-33
-
-
Tran, T.K.C.1
Vigneron, D.B.2
Sailasuta, N.3
Tropp, J.4
Le Roux, P.5
Kurhanewicz, J.6
Nelson, S.7
Hurd, R.8
-
5
-
-
0035021436
-
BISTRO: An outer-volume suppression method that tolerates RF field inhomogeneity
-
Luo Y., de Graaf R.A., DelaBarre L., Tannus A., Garwood M. BISTRO: an outer-volume suppression method that tolerates RF field inhomogeneity. Magn. Reson. Med. 45(6):2001;1095-1102.
-
(2001)
Magn. Reson. Med.
, vol.45
, Issue.6
, pp. 1095-1102
-
-
Luo, Y.1
De Graaf, R.A.2
Delabarre, L.3
Tannus, A.4
Garwood, M.5
-
6
-
-
45149145242
-
A k-space analysis of small-tip-angle excitation
-
Pauly J.M., Nishimura D.G., Macovski A. A k-space analysis of small-tip-angle excitation. J. Magn. Reson. 81(1):1989;43-56.
-
(1989)
J. Magn. Reson.
, vol.81
, Issue.1
, pp. 43-56
-
-
Pauly, J.M.1
Nishimura, D.G.2
Macovski, A.3
-
7
-
-
0022739029
-
Optimal control solutions to the magnetic resonance selective excitation problem
-
Conolly S.M., Nishimura D.G., Macovski A. Optimal control solutions to the magnetic resonance selective excitation problem. IEEE T Med. Imaging. MI-5(2):1986;106-115.
-
(1986)
IEEE T Med. Imaging
, vol.MI-5
, Issue.2
, pp. 106-115
-
-
Conolly, S.M.1
Nishimura, D.G.2
Macovski, A.3
-
8
-
-
0041923327
-
Selective inversion radio frequency pulses by optimal control
-
Mao J., Mareci T.H., Scott K.N., Andrew E.R. Selective inversion radio frequency pulses by optimal control. J. Magn. Reson. 70(2):1986;310-318.
-
(1986)
J. Magn. Reson.
, vol.70
, Issue.2
, pp. 310-318
-
-
Mao, J.1
Mareci, T.H.2
Scott, K.N.3
Andrew, E.R.4
-
9
-
-
0001748640
-
Band-selective pulses without phase distortion. A simulated annealing approach
-
Geen H., Wimperis S., Freeman R. Band-selective pulses without phase distortion. A simulated annealing approach. J. Magn. Reson. 85(3):1989;620-627.
-
(1989)
J. Magn. Reson.
, vol.85
, Issue.3
, pp. 620-627
-
-
Geen, H.1
Wimperis, S.2
Freeman, R.3
-
10
-
-
0026116321
-
Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm
-
Pauly J.M., Le Roux P., Nishimura D.G., Macovski A. Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm. IEEE T Med. Imaging. 10(1):1991;53-65.
-
(1991)
IEEE T Med. Imaging
, vol.10
, Issue.1
, pp. 53-65
-
-
Pauly, J.M.1
Le Roux, P.2
Nishimura, D.G.3
Macovski, A.4
-
11
-
-
0024445374
-
The application of spinors to pulse synthesis and analysis
-
Shinnar M., Leigh J.S. The application of spinors to pulse synthesis and analysis. Magn. Reson. Med. 12(1):1989;93-98.
-
(1989)
Magn. Reson. Med.
, vol.12
, Issue.1
, pp. 93-98
-
-
Shinnar, M.1
Leigh, J.S.2
-
12
-
-
0029270767
-
Complex Chebyshev approximation for FIR filter design
-
Karam L.J., McClellan J.H. Complex Chebyshev approximation for FIR filter design. IEEE T Circuits-II. 42(3):1995;207-216.
-
(1995)
IEEE T Circuits-II
, vol.42
, Issue.3
, pp. 207-216
-
-
Karam, L.J.1
Mcclellan, J.H.2
-
13
-
-
0032632780
-
Chebyshev digital FIR filter design
-
Karam L.J., McClellan J.H. Chebyshev digital FIR filter design. Signal Process. 76(1):1999;17-36.
-
(1999)
Signal Process.
, vol.76
, Issue.1
, pp. 17-36
-
-
Karam, L.J.1
Mcclellan, J.H.2
-
14
-
-
0027946444
-
Reduced power selective excitation radio frequency pulses
-
Shinnar M. Reduced power selective excitation radio frequency pulses. Magn. Reson. Med. 32(5):1994;658-660.
-
(1994)
Magn. Reson. Med.
, vol.32
, Issue.5
, pp. 658-660
-
-
Shinnar, M.1
-
15
-
-
0003517252
-
-
New York: McGraw-Hill. Chapter 8
-
Papoulis A. Signal Analysis. 1977;McGraw-Hill, New York. Chapter 8.
-
(1977)
Signal Analysis
-
-
Papoulis, A.1
-
16
-
-
0015316461
-
Chebyshev approximation for nonrecusrive digital filters with linear phase
-
Parks T.W., McClellan J.H. Chebyshev approximation for nonrecusrive digital filters with linear phase. IEEE Trans. Circuit Theory CT. 19(2):1972;189-194.
-
(1972)
IEEE Trans. Circuit Theory CT
, vol.19
, Issue.2
, pp. 189-194
-
-
Parks, T.W.1
Mcclellan, J.H.2
-
18
-
-
0347307116
-
Fast simulation of MR-excitation considering flow and motion
-
Pruessmann K.P., Spiegel M.A., Crelier G.R., Stuber M., Scheidegger M.B., Boesiger P. Fast simulation of MR-excitation considering flow and motion. Proc. Intl. Soc. Mag. Reson. Med. 5:1997;1537.
-
(1997)
Proc. Intl. Soc. Mag. Reson. Med.
, vol.5
, pp. 1537
-
-
Pruessmann, K.P.1
Spiegel, M.A.2
Crelier, G.R.3
Stuber, M.4
Scheidegger, M.B.5
Boesiger, P.6
-
19
-
-
0346676571
-
Non-linear phase RF pulses for reduced dynamic range in 3D RARE imaging
-
Pauly J.M., Wong E.C. Non-linear phase RF pulses for reduced dynamic range in 3D RARE imaging. Proc. Intl. Soc. Mag. Reson. Med. 9:2001;688.
-
(2001)
Proc. Intl. Soc. Mag. Reson. Med.
, vol.9
, pp. 688
-
-
Pauly, J.M.1
Wong, E.C.2
-
21
-
-
0023121544
-
Frequency-modulated radiofrequency pulses in spin-echo and stimulated-echo experiments
-
Kunz D.W. Frequency-modulated radiofrequency pulses in spin-echo and stimulated-echo experiments. Magn. Reson. Med. 4(2):1987;129-136.
-
(1987)
Magn. Reson. Med.
, vol.4
, Issue.2
, pp. 129-136
-
-
Kunz, D.W.1
-
22
-
-
0036298982
-
Adjustable, broadband, selective excitation with uniform phase
-
Cano K.E., Smith M.A., Shaka A.J. Adjustable, broadband, selective excitation with uniform phase. J. Magn. Reson. 155(1):2002;131-139.
-
(2002)
J. Magn. Reson.
, vol.155
, Issue.1
, pp. 131-139
-
-
Cano, K.E.1
Smith, M.A.2
Shaka, A.J.3
-
24
-
-
0028850689
-
Spatial encoding and reconstruction in MRI with quadratic phase profiles
-
Pipe J.G. Spatial encoding and reconstruction in MRI with quadratic phase profiles. Magn. Reson. Med. 33(1):1995;24-33.
-
(1995)
Magn. Reson. Med.
, vol.33
, Issue.1
, pp. 24-33
-
-
Pipe, J.G.1
-
25
-
-
0026500406
-
Reduction of susceptibility artifact in gradient-echo imaging
-
Cho Z.H., Ro Y.M. Reduction of susceptibility artifact in gradient-echo imaging. Magn. Reson. Med. 23(1):1992;193-200.
-
(1992)
Magn. Reson. Med.
, vol.23
, Issue.1
, pp. 193-200
-
-
Cho, Z.H.1
Ro, Y.M.2
-
26
-
-
0032851488
-
Removal of intravoxel dephasing artifact in gradient-echo images using a field-map based RF refocusing technique
-
Chen N., Wyrwicz A.M. Removal of intravoxel dephasing artifact in gradient-echo images using a field-map based RF refocusing technique. Magn. Reson. Med. 42(4):1999;807-812.
-
(1999)
Magn. Reson. Med.
, vol.42
, Issue.4
, pp. 807-812
-
-
Chen, N.1
Wyrwicz, A.M.2
-
27
-
-
0034894659
-
Single-shot EPI with signal recovery from the susceptibility-induced losses
-
Song A.W. Single-shot EPI with signal recovery from the susceptibility-induced losses. Magn. Reson. Med. 46(2):2001;407-411.
-
(2001)
Magn. Reson. Med.
, vol.46
, Issue.2
, pp. 407-411
-
-
Song, A.W.1
|