메뉴 건너뛰기




Volumn 20, Issue 5, 2010, Pages 261-267

Application of artificial tactile sensing approach in kidney-stone-removal laparoscopy

Author keywords

artificial palpation; Artificial tactile sensing; kidney stone; laparoscopic surgery

Indexed keywords

ARTIFICIAL PALPATION; FINITE ELEMENT ANALYSIS; KIDNEY STONE; LAPAROSCOPIC SURGERY; MECHANICAL LOADS; NEW APPLICATIONS; NOVEL METHODS; OPEN SURGERY; SOFT TISSUE; STRESS DISTRIBUTION; STRESS PATTERNS; TACTILE SENSING;

EID: 78649524764     PISSN: 09592989     EISSN: None     Source Type: Journal    
DOI: 10.3233/BME-2010-0640     Document Type: Conference Paper
Times cited : (11)

References (25)
  • 1
    • 0026118160 scopus 로고
    • Tactile sensing-technology and applications
    • P. Dario, Tactile sensing-technology and applications, Sensors and Actuators A-Physical 26 (1991), 251-261.
    • (1991) Sensors and Actuators A-Physical , vol.26 , pp. 251-261
    • Dario, P.1
  • 2
    • 20444452839 scopus 로고    scopus 로고
    • Advances in tactile sensors design/manufacturing and its impact on robotic application-A review
    • J. Dargahi and S. Najarian, Advances in tactile sensors design/manufacturing and its impact on robotic application-A review, Industrial Robots 32(3) (2005), 268-281.
    • (2005) Industrial Robots , vol.32 , Issue.3 , pp. 268-281
    • Dargahi, J.1    Najarian, S.2
  • 4
    • 34548699495 scopus 로고    scopus 로고
    • Design and fabrication of a new tactile probe for measuring the modulus of elasticity of soft tissues
    • H. Roham, S. Najarian, S.M. Hosseini and J. Dargahi, Design and fabrication of a new tactile probe for measuring the modulus of elasticity of soft tissues, Sensor Review 27(4) (2007), 317-323.
    • (2007) Sensor Review , vol.27 , Issue.4 , pp. 317-323
    • Roham, H.1    Najarian, S.2    Hosseini, S.M.3    Dargahi, J.4
  • 5
    • 0035819462 scopus 로고    scopus 로고
    • Minimally invasive and robotic surgery
    • M. Mack, Minimally invasive and robotic surgery, Opportunities for Medical Research 285(5) (2001), 568-572.
    • (2001) Opportunities for Medical Research , vol.285 , Issue.5 , pp. 568-572
    • MacK, M.1
  • 7
    • 28244463219 scopus 로고    scopus 로고
    • Robotic surgery; Potentials barriers and limitations
    • J. Marescaux and F. Rubino, Robotic surgery; potentials, barriers and limitations, European Surgery 37(5) (2005), 279-283.
    • (2005) European Surgery , vol.37 , Issue.5 , pp. 279-283
    • Marescaux, J.1    Rubino, F.2
  • 13
    • 33749678423 scopus 로고    scopus 로고
    • Detecting embedded objects using haptics with applications in artificial palpation of tumors
    • S. Najarian, J. Dargahi and V. Mirjalili, Detecting embedded objects using haptics with applications in artificial palpation of tumors, Sensors and Materials 18(4) (2006), 215-229.
    • (2006) Sensors and Materials , vol.18 , Issue.4 , pp. 215-229
    • Najarian, S.1    Dargahi, J.2    Mirjalili, V.3
  • 16
    • 0005189973 scopus 로고    scopus 로고
    • Finger tracking for breast palpation quantification using color image features
    • J. Zeng, Y. Wang, M.T. Freedman and S.K. Mum, Finger tracking for breast palpation quantification using color image features, SPIE Journal of Optical Engineering 36(12) (1997), 3455-3461.
    • (1997) SPIE Journal of Optical Engineering , vol.36 , Issue.12 , pp. 3455-3461
    • Zeng, J.1    Wang, Y.2    Freedman, M.T.3    Mum, S.K.4
  • 17
    • 0037438982 scopus 로고    scopus 로고
    • Active tactile sensor for detecting contact force and hardness of an object
    • M. Shikida, T. Shimizu, K. Sato and K. Itoigawa, Active tactile sensor for detecting contact force and hardness of an object, Sensors Actuators A 103 (2003), 213-218.
    • (2003) Sensors Actuators A , vol.103 , pp. 213-218
    • Shikida, M.1    Shimizu, T.2    Sato, K.3    Itoigawa, K.4
  • 18
    • 0002575093 scopus 로고    scopus 로고
    • Tactile sensing for mechatronics-A state of the art survey
    • M.H. Lee and H.R. Nicholls, Tactile sensing for mechatronics-A state of the art survey, Mechatronics 9(1) (1999), 1-31.
    • (1999) Mechatronics , vol.9 , Issue.1 , pp. 1-31
    • Lee, M.H.1    Nicholls, H.R.2
  • 19
    • 1842816436 scopus 로고    scopus 로고
    • Analysis of a membrane type polymericbased tactile sensor for biomedical and medical robotic applications
    • J. Dargahi and S. Najarian, Analysis of a membrane type polymericbased tactile sensor for biomedical and medical robotic applications, Sensor and Materials 16(1) (2004), 25-41.
    • (2004) Sensor and Materials , vol.16 , Issue.1 , pp. 25-41
    • Dargahi, J.1    Najarian, S.2
  • 20
    • 0035192820 scopus 로고    scopus 로고
    • Feasibility of robotic laparoscopic surgery: 146 cases
    • G. Cadiere, J. Himpens et al., Feasibility of robotic laparoscopic surgery: 146 cases, World Journal of Surgery 25 (2001), 1467-1477.
    • (2001) World Journal of Surgery , vol.25 , pp. 1467-1477
    • Cadiere, G.1    Himpens, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.