-
1
-
-
0029810740
-
Metal on metal surface replacement of the hip. Experience of the mcminn prosthesis
-
McMinn D, Treacy R, Lin K, Pynsent P Metal on metal surface replacement of the hip. Experience of the mcminn prosthesis. Clinical Orthopaedics and Related Research 1996, 329(Suppl):S89-S98.
-
(1996)
Clinical Orthopaedics and Related Research
, vol.329
, Issue.SUPPL
-
-
McMinn, D.1
Treacy, R.2
Lin, K.3
Pynsent, P.4
-
3
-
-
0036317638
-
A systematic review of the effectiveness and cost-effectiveness of metal-on-metal hip resurfacing arthroplasty for treatment of hip disease
-
Vale L, Wyness L, McCormack K, McKenzie L, Brazzelli M, Stearns SC A systematic review of the effectiveness and cost-effectiveness of metal-on-metal hip resurfacing arthroplasty for treatment of hip disease. Health Technology Assessment 2002, 6:1-109.
-
(2002)
Health Technology Assessment
, vol.6
, pp. 1-109
-
-
Vale, L.1
Wyness, L.2
McCormack, K.3
McKenzie, L.4
Brazzelli, M.5
Stearns, S.C.6
-
4
-
-
12944336407
-
The contribution of frictional torque to loosening at the cement-bone interface in Tharies hip replacements
-
Mai MT, Schmalzried TP, Dorey FJ, Campbell PA, Amstutz HC The contribution of frictional torque to loosening at the cement-bone interface in Tharies hip replacements. Journal of Bone and Joint Surgery 1996, 78:505-511.
-
(1996)
Journal of Bone and Joint Surgery
, vol.78
, pp. 505-511
-
-
Mai, M.T.1
Schmalzried, T.P.2
Dorey, F.J.3
Campbell, P.A.4
Amstutz, H.C.5
-
6
-
-
78649359635
-
-
Hip resurfacing arthroplasty: The Liverpool experience. Proceedings of the IMechE Meeting Engineers & Surgeons - Joined at the Hip, London, UK
-
Ebied A, Journeaux S F, Pope J A. Hip resurfacing arthroplasty: The Liverpool experience. Proceedings of the IMechE Meeting Engineers & Surgeons - Joined at the Hip, London, UK, 2002.
-
(2002)
-
-
Ebied, A.1
Journeaux, S.F.2
Pope, J.A.3
-
7
-
-
0029814931
-
Distribution of cobalt chromium wear and corrion products and biological reactions
-
Merritt K, Brown SA Distribution of cobalt chromium wear and corrion products and biological reactions. Clinical Orthopaedics Related Research 1996, 329(Suppl):S233-S243.
-
(1996)
Clinical Orthopaedics Related Research
, vol.329
, Issue.SUPPL
-
-
Merritt, K.1
Brown, S.A.2
-
8
-
-
0037233869
-
Metal-on-metal versus polyethylene in hip arthroplasty: A randomized clinical trial
-
MacDonald SJ, McCalden RW, Chess DG, Bourne RB, Rorabeck CH, Cleland D, Leung F Metal-on-metal versus polyethylene in hip arthroplasty: A randomized clinical trial. Clinical Orthopaedics Related Research 2003, 406:282-296.
-
(2003)
Clinical Orthopaedics Related Research
, vol.406
, pp. 282-296
-
-
MacDonald, S.J.1
McCalden, R.W.2
Chess, D.G.3
Bourne, R.B.4
Rorabeck, C.H.5
Cleland, D.6
Leung, F.7
-
9
-
-
33645219347
-
Metal-on-metal bearings surfaces: Materials, manufacture, design, optimization, and alternatives
-
Isaac GH, Thompson J, Williams S, Fisher J Metal-on-metal bearings surfaces: Materials, manufacture, design, optimization, and alternatives. Proceedings of the Institution of Mechanical Engineering, Part H: Journal of Engineering in Medicine 2006, 220:119-133.
-
(2006)
Proceedings of the Institution of Mechanical Engineering, Part H: Journal of Engineering in Medicine
, vol.220
, pp. 119-133
-
-
Isaac, G.H.1
Thompson, J.2
Williams, S.3
Fisher, J.4
-
10
-
-
33645231656
-
Clinical experience with metal-on-metal total joint replacements: Indications and results
-
Learmonth ID, Gheduzzi S, Vail TP Clinical experience with metal-on-metal total joint replacements: Indications and results. Proceedings of the Institution of Mechanical Engineering, Part H: Journal of Engineering in Medicine 2006, 220:229-237.
-
(2006)
Proceedings of the Institution of Mechanical Engineering, Part H: Journal of Engineering in Medicine
, vol.220
, pp. 229-237
-
-
Learmonth, I.D.1
Gheduzzi, S.2
Vail, T.P.3
-
11
-
-
0018084417
-
Cement-free bioceramic double-cup endoprosthesis of the hip joint
-
Salzer M, Knahr K, Locke H, Stark N Cement-free bioceramic double-cup endoprosthesis of the hip joint. Clinical Orthopaedics Related Research 1978, 134:80-86.
-
(1978)
Clinical Orthopaedics Related Research
, vol.134
, pp. 80-86
-
-
Salzer, M.1
Knahr, K.2
Locke, H.3
Stark, N.4
-
12
-
-
0018177689
-
Surface replacement arthroplasty of the hip
-
Wagner H Surface replacement arthroplasty of the hip. Clinical Orthopaedics Related Research 1978, 134:102-130.
-
(1978)
Clinical Orthopaedics Related Research
, vol.134
, pp. 102-130
-
-
Wagner, H.1
-
13
-
-
0345168992
-
Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation
-
Stewart TD, Tipper JL, Insley G, Streicher RM, Ingham E, Fisher J Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation. Journal of Biomedical Materials Research Part B: Applied Biomaterials 2003, 66:567-573.
-
(2003)
Journal of Biomedical Materials Research Part B: Applied Biomaterials
, vol.66
, pp. 567-573
-
-
Stewart, T.D.1
Tipper, J.L.2
Insley, G.3
Streicher, R.M.4
Ingham, E.5
Fisher, J.6
-
15
-
-
0029831455
-
In vivo wear of three types of metal on metal hip prostheses during two decades of use
-
McKellop H, Park SH, Chiesa R, Doorn P, Lu B, Normand P, Grigoris P, Amstutz H In vivo wear of three types of metal on metal hip prostheses during two decades of use. Clinical Orthopaedics & Related Research 1996, 329(Suppl):S128-S140.
-
(1996)
Clinical Orthopaedics & Related Research
, vol.329
, Issue.SUPPL
-
-
McKellop, H.1
Park, S.H.2
Chiesa, R.3
Doorn, P.4
Lu, B.5
Normand, P.6
Grigoris, P.7
Amstutz, H.8
-
16
-
-
0030210397
-
Comparison of alloys and designs in a hip simulator study of metal on metal implants
-
Medley JB, Chan FW, Krygier JJ, Bobyn JD Comparison of alloys and designs in a hip simulator study of metal on metal implants. Clinical Orthopaedics & Related Research 1996, 329(Suppl):S148-S159.
-
(1996)
Clinical Orthopaedics & Related Research
, vol.329
, Issue.SUPPL
-
-
Medley, J.B.1
Chan, F.W.2
Krygier, J.J.3
Bobyn, J.D.4
-
18
-
-
0033630259
-
A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements
-
Goldsmith AA, Dowson D, Isaac GH, Lancaster JG A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal Engineering in Medicine 2000, 214:39-47.
-
(2000)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal Engineering in Medicine
, vol.214
, pp. 39-47
-
-
Goldsmith, A.A.1
Dowson, D.2
Isaac, G.H.3
Lancaster, J.G.4
-
19
-
-
33744521921
-
Bone remodelling inside a cemented resurfaced femoral head
-
Gupta S, New AMR, Taylor M Bone remodelling inside a cemented resurfaced femoral head. Clinical Biomechanics 2006, 21:594-602.
-
(2006)
Clinical Biomechanics
, vol.21
, pp. 594-602
-
-
Gupta, S.1
New, A.M.R.2
Taylor, M.3
-
20
-
-
78649352083
-
Design considerations for ceramic resurfaced femoral head: Effect of interface characteristics on failure mechanisms
-
Pal B, Gupta S, New AMR Design considerations for ceramic resurfaced femoral head: Effect of interface characteristics on failure mechanisms. Computer Methods in Biomechanics and Biomedical Engineering 2009, 3:1-13.
-
(2009)
Computer Methods in Biomechanics and Biomedical Engineering
, vol.3
, pp. 1-13
-
-
Pal, B.1
Gupta, S.2
New, A.M.R.3
-
21
-
-
0034125311
-
Biomechanical study of the resurfacing hip arthroplasty: Finite element analysis of the femoral component
-
Watanabe Y, Shiba N, Matsuo S, Higuchi F, Tagawa Y, Inoue A Biomechanical study of the resurfacing hip arthroplasty: Finite element analysis of the femoral component. Journal of Arthroplasty 2000, 15:505-511.
-
(2000)
Journal of Arthroplasty
, vol.15
, pp. 505-511
-
-
Watanabe, Y.1
Shiba, N.2
Matsuo, S.3
Higuchi, F.4
Tagawa, Y.5
Inoue, A.6
-
22
-
-
0036048713
-
Effects of acetabular resurfacing component material and fixation on the strain distribution in the pelvis
-
Thompson MS, Northmore-Ball MD, Tanner KE Effects of acetabular resurfacing component material and fixation on the strain distribution in the pelvis. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 2002, 216:237-245.
-
(2002)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.216
, pp. 237-245
-
-
Thompson, M.S.1
Northmore-Ball, M.D.2
Tanner, K.E.3
-
23
-
-
0029380382
-
Cancellous bone stresses surrounding the femoral component of a hip prosthesis: an elastic-plastic finite element analysis
-
Taylor M, Tanner KE, Freeman MAR, Yettram AL Cancellous bone stresses surrounding the femoral component of a hip prosthesis: an elastic-plastic finite element analysis. Medical Engineering & Physics 1995, 17:544-550.
-
(1995)
Medical Engineering & Physics
, vol.17
, pp. 544-550
-
-
Taylor, M.1
Tanner, K.E.2
Freeman, M.A.R.3
Yettram, A.L.4
-
26
-
-
0032189496
-
A parametric study of acetabular cup design variables using finite element analysis and statistical design of experiments
-
Mantell SC, Chanda H, Bechtold JE, Kyle RF A parametric study of acetabular cup design variables using finite element analysis and statistical design of experiments. Journal of Biomechanical Engineering-Transactions of the ASME 1998, 120:667-675.
-
(1998)
Journal of Biomechanical Engineering-Transactions of the ASME
, vol.120
, pp. 667-675
-
-
Mantell, S.C.1
Chanda, H.2
Bechtold, J.E.3
Kyle, R.F.4
-
27
-
-
0027641060
-
Hip joint loading during walking and running, measured in two patients
-
Bergmann G, Graichen F, Rohlmann A Hip joint loading during walking and running, measured in two patients. Journal of Biomechanics 1993, 26:969-990.
-
(1993)
Journal of Biomechanics
, vol.26
, pp. 969-990
-
-
Bergmann, G.1
Graichen, F.2
Rohlmann, A.3
-
28
-
-
0034984126
-
Hip contact forces and gait patterns from routine activities
-
Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, Duda GN Hip contact forces and gait patterns from routine activities. Journal of Biomechanics 2001, 34:859-871.
-
(2001)
Journal of Biomechanics
, vol.34
, pp. 859-871
-
-
Bergmann, G.1
Deuretzbacher, G.2
Heller, M.3
Graichen, F.4
Rohlmann, A.5
Strauss, J.6
Duda, G.N.7
-
29
-
-
16544389414
-
Contact mechanics analysis of metal-on-metal hip resurfacing prostheses
-
Udofia IJ, Yew A, Jin ZM Contact mechanics analysis of metal-on-metal hip resurfacing prostheses. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 2004, 218:293-304.
-
(2004)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.218
, pp. 293-304
-
-
Udofia, I.J.1
Yew, A.2
Jin, Z.M.3
-
30
-
-
0036146774
-
Hip joint contact forces in normal subjects and subjects with total hip prostheses: walking and stair and ramp negotiation
-
Stansfield BW, Nicol AC Hip joint contact forces in normal subjects and subjects with total hip prostheses: walking and stair and ramp negotiation. Clinical Biomechanics 2002, 17:130-139.
-
(2002)
Clinical Biomechanics
, vol.17
, pp. 130-139
-
-
Stansfield, B.W.1
Nicol, A.C.2
-
31
-
-
70350430031
-
Mixing and matching in ceramic-on-metal hip arthroplasty: An in-vitro hip simulator study
-
Affatato S, Spinelli M, Squarzoni S, Traina F, Toni A Mixing and matching in ceramic-on-metal hip arthroplasty: An in-vitro hip simulator study. Journal of Biomechanics 2002, 42:2439-2446.
-
(2002)
Journal of Biomechanics
, vol.42
, pp. 2439-2446
-
-
Affatato, S.1
Spinelli, M.2
Squarzoni, S.3
Traina, F.4
Toni, A.5
-
32
-
-
39149099788
-
Friction and wear behavior of structural ceramics sliding against zirconia
-
Suh MS, Chae YH, Kim SS Friction and wear behavior of structural ceramics sliding against zirconia. Wear 2008, 264:800-806.
-
(2008)
Wear
, vol.264
, pp. 800-806
-
-
Suh, M.S.1
Chae, Y.H.2
Kim, S.S.3
-
33
-
-
76349123810
-
Metal ions levels measurements for early total hip replacement malfunction diagnosis with " plasma-sprayed ceramic" bearings couple
-
Schiopu D, Girard J, Soenen M, Krantz M, Migaud H Metal ions levels measurements for early total hip replacement malfunction diagnosis with " plasma-sprayed ceramic" bearings couple. Orthopaedic Trauma Surgery Research 2010, 96:75-79.
-
(2010)
Orthopaedic Trauma Surgery Research
, vol.96
, pp. 75-79
-
-
Schiopu, D.1
Girard, J.2
Soenen, M.3
Krantz, M.4
Migaud, H.5
-
35
-
-
0034308380
-
Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur
-
Wirtz DC, Schiffers N, Pandorf T, Radermacher K, Weichert D, Forst R Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur. Journal of Biomechanics 2000, 33:1325-1330.
-
(2000)
Journal of Biomechanics
, vol.33
, pp. 1325-1330
-
-
Wirtz, D.C.1
Schiffers, N.2
Pandorf, T.3
Radermacher, K.4
Weichert, D.5
Forst, R.6
-
37
-
-
0030627631
-
Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus
-
Jin ZM, Dowson D, Fisher J Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 1997, 211:247-256.
-
(1997)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.211
, pp. 247-256
-
-
Jin, Z.M.1
Dowson, D.2
Fisher, J.3
-
38
-
-
0031049064
-
Metal-on-metal CoCrMo Mckee-Farrar total hip arthroplasty: Characteristics from a long-term follow-up study
-
Higuchi F, Inoue A, Semlitsch M Metal-on-metal CoCrMo Mckee-Farrar total hip arthroplasty: Characteristics from a long-term follow-up study. Archives of Orthopaedic and Trauma Surgery 1997, 116:121-124.
-
(1997)
Archives of Orthopaedic and Trauma Surgery
, vol.116
, pp. 121-124
-
-
Higuchi, F.1
Inoue, A.2
Semlitsch, M.3
-
39
-
-
0032610912
-
An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements
-
Jin ZM, Heng SM, Ng HW, Auger DD An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 1999, 213:317-327.
-
(1999)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.213
, pp. 317-327
-
-
Jin, Z.M.1
Heng, S.M.2
Ng, H.W.3
Auger, D.D.4
-
40
-
-
0035143942
-
Prediction of lubricating film thickness in UHMWPE hip joint replacements
-
Jalali-Vahid D, Jagatia M, Jin ZM, Dowson D Prediction of lubricating film thickness in UHMWPE hip joint replacements. Journal of Biomechanics 2001, 34:261-266.
-
(2001)
Journal of Biomechanics
, vol.34
, pp. 261-266
-
-
Jalali-Vahid, D.1
Jagatia, M.2
Jin, Z.M.3
Dowson, D.4
-
41
-
-
78649364875
-
-
What caused equatorial contact in mckee-farrar metal-on-metal hip implants? Proceedings of the IMechE Meeting Engineers & Surgeons - Joined at the Hip, London, UK
-
Yew A, Ensaff H, Jin Z M. What caused equatorial contact in mckee-farrar metal-on-metal hip implants? Proceedings of the IMechE Meeting Engineers & Surgeons - Joined at the Hip, London, UK, 2002.
-
(2002)
-
-
Yew, A.1
Ensaff, H.2
Jin, Z.M.3
-
42
-
-
0028541733
-
Treatment of the ipsilateral femur shaft and femur neck fractures with the Russell-Taylor reconstruction nail
-
(in German).
-
Ostermann PA, Henry SL Treatment of the ipsilateral femur shaft and femur neck fractures with the Russell-Taylor reconstruction nail. Chirurg 1994, 65:1042-1045. (in German).
-
(1994)
Chirurg
, vol.65
, pp. 1042-1045
-
-
Ostermann, P.A.1
Henry, S.L.2
-
44
-
-
61549120772
-
Cephalomedullary nails in the management of ipsilateral neck and shaft fractures of the femur-One or two femoral neck screws?
-
Vidyadhara S, Rao SK Cephalomedullary nails in the management of ipsilateral neck and shaft fractures of the femur-One or two femoral neck screws?. Injury 2009, 40:296-303.
-
(2009)
Injury
, vol.40
, pp. 296-303
-
-
Vidyadhara, S.1
Rao, S.K.2
-
45
-
-
0029347467
-
Fixation and effect on bone strain pattern of a stemless hip prosthesis
-
Munting E, Verhelpen M Fixation and effect on bone strain pattern of a stemless hip prosthesis. Journal of Biomechanics 1995, 28:949-961.
-
(1995)
Journal of Biomechanics
, vol.28
, pp. 949-961
-
-
Munting, E.1
Verhelpen, M.2
-
46
-
-
0033816740
-
Analysis of a femoral hip prosthesis designed to reduce stress shielding
-
Joshi MG, Advani SG, Miller F, Santare MH Analysis of a femoral hip prosthesis designed to reduce stress shielding. Journal of Biomechanics 2000, 33:1655-1662.
-
(2000)
Journal of Biomechanics
, vol.33
, pp. 1655-1662
-
-
Joshi, M.G.1
Advani, S.G.2
Miller, F.3
Santare, M.H.4
-
47
-
-
78649341821
-
-
FEA in the design of a novel hip resurfacing prosthesis. Proceedings of the 12th Conference of the European Society of Biomechanics, Dublin, Ireland
-
Thompson M S, Northmore-Ball M D, Tanner K E. FEA in the design of a novel hip resurfacing prosthesis. Proceedings of the 12th Conference of the European Society of Biomechanics, Dublin, Ireland, 2000, 115-127.
-
(2000)
, pp. 115-127
-
-
Thompson, M.S.1
Northmore-Ball, M.D.2
Tanner, K.E.3
-
48
-
-
0035207960
-
Alumina bearings in hip replacement: Theoretical and practical aspects
-
Bizot P, Sedel L Alumina bearings in hip replacement: Theoretical and practical aspects. Operative Techniques in Orthopaedics 2001, 11:263-269.
-
(2001)
Operative Techniques in Orthopaedics
, vol.11
, pp. 263-269
-
-
Bizot, P.1
Sedel, L.2
-
50
-
-
0026821443
-
Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants
-
Shirazi-Adl A, Dammak M, Paiement G Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants. Journal of Biomedical Materials Research 1993, 27:167-175.
-
(1993)
Journal of Biomedical Materials Research
, vol.27
, pp. 167-175
-
-
Shirazi-Adl, A.1
Dammak, M.2
Paiement, G.3
|