Radiation dose to the operator during vertebroplasty: Prospective comparison of the use of 1-cc syringes versus an injection device

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOGRAPHY; ARTICLE; CLINICAL ARTICLE; DOSIMETER; DOSIMETRY; HUMAN; INJECTION; INTERMETHOD COMPARISON; PERCUTANEOUS VERTEBROPLASTY; PROSPECTIVE STUDY; RADIATION DOSE; RADIOLOGIST; SYRINGE; THERMOLUMINESCENCE DOSIMETER;

EID: 0038275749     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (57)

References (11)
  • 1
    • 0034655411 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for pain relief and spinal stabilization
    • Barr JD, Barr MS, Lemley TJ, McCann RM. Percutaneous vertebroplasty for pain relief and spinal stabilization. Spine 2000;25: 923-928
    • (2000) Spine , vol.25 , pp. 923-928
    • Barr, J.D.1    Barr, M.S.2    Lemley, T.J.3    McCann, R.M.4
  • 2
    • 0031545893 scopus 로고    scopus 로고
    • Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects
    • Jensen ME, Evans AJ, Mathis JM, Kallmes DF, Cloft HJ, Dion JE. Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects. AJNR Am J Neuroradiol 1997;18:1897-1904
    • (1997) AJNR Am J Neuroradiol , vol.18 , pp. 1897-1904
    • Jensen, M.E.1    Evans, A.J.2    Mathis, J.M.3    Kallmes, D.F.4    Cloft, H.J.5    Dion, J.E.6
  • 3
    • 0027979920 scopus 로고
    • Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy
    • Gangi A, Kastler BA, Dietemann JL. Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy. AJNR Am J Neuroradiol 1994;15:83-86
    • (1994) AJNR Am J Neuroradiol , vol.15 , pp. 83-86
    • Gangi, A.1    Kastler, B.A.2    Dietemann, J.L.3
  • 5
    • 0036083754 scopus 로고    scopus 로고
    • Is Percutaneous vertebroplasty without pretreatment venography safe? Evaluation of 205 consecutives procedures
    • Vasconcelos C, Gailloud P, Beauchamp NJ, Heck DV, Murphy KJ. Is Percutaneous vertebroplasty without pretreatment venography safe? evaluation of 205 consecutives procedures. AJNR Am J Neuroradiol 2002;23:913-917
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 913-917
    • Vasconcelos, C.1    Gailloud, P.2    Beauchamp, N.J.3    Heck, D.V.4    Murphy, K.J.5
  • 8
    • 0036192447 scopus 로고    scopus 로고
    • Vertebroplasty: Reusable flange converter with hub lock for injection of polymethylmethacrylate with screwplunger syringe
    • Schallen EH, Gilula LA. Vertebroplasty: reusable flange converter with hub lock for injection of polymethylmethacrylate with screwplunger syringe. Radiology 2002;222:851-855
    • (2002) Radiology , vol.222 , pp. 851-855
    • Schallen, E.H.1    Gilula, L.A.2
  • 10
    • 0032015176 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty: State of the art
    • Cotten A, Boutry N, Cortet B, et al. Percutaneous vertebroplasty: state of the art. Radiographics 1998;18:311-323
    • (1998) Radiographics , vol.18 , pp. 311-323
    • Cotten, A.1    Boutry, N.2    Cortet, B.3
  • 11
    • 0037956133 scopus 로고    scopus 로고
    • Washington: U.S. Government Printing Office; 10 CFR 20
    • U.S. Nuclear Regulatory Commission. Occupational Dose Limits for Adults. Washington: U.S. Government Printing Office; 2002:10 CFR 20.1201
    • (2002) Occupational Dose Limits for Adults


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.