메뉴 건너뛰기




Volumn 37, Issue 11, 2010, Pages 5665-5671

Dosimetric optimization of a conical breast brachytherapy applicator for improved skin dose sparing

Author keywords

applicator; brachytherapy; dosimetry; Ir 192; optimization

Indexed keywords

APPLICATORS; DOSIMETRY; IONIZATION; IONIZATION CHAMBERS; ONCOLOGY; OPTIMIZATION; RADIOTHERAPY; TUNGSTEN ALLOYS;

EID: 78149433895     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3495539     Document Type: Article
Times cited : (14)

References (13)
  • 1
    • 61349188243 scopus 로고    scopus 로고
    • Monte Carlo simulations and radiation dosimetry measurements of peripherally-applied HDR i 192 r breast brachytherapy D-shaped applicators
    • MPHYA6 0094-2405,. 10.1118/1.3075818
    • Y. Yang and M. J. Rivard, " Monte Carlo simulations and radiation dosimetry measurements of peripherally-applied HDR I 192 r breast brachytherapy D-shaped applicators.," Med. Phys. MPHYA6 0094-2405 36, 809-815 (2009). 10.1118/1.3075818
    • (2009) Med. Phys. , vol.36 , pp. 809-815
    • Yang, Y.1    Rivard, M.J.2
  • 2
    • 70350738100 scopus 로고    scopus 로고
    • Dosimetric characterization of round HDR i 192 r AccuBoost applicators
    • MPHYA6 0094-2405,. 10.1118/1.3232001
    • M. J. Rivard, C. S. Melhus, D. E. Wazer, and R. J. Bricault, " Dosimetric characterization of round HDR I 192 r AccuBoost applicators.," Med. Phys. MPHYA6 0094-2405 36, 5027-5032 (2009). 10.1118/1.3232001
    • (2009) Med. Phys. , vol.36 , pp. 5027-5032
    • Rivard, M.J.1    Melhus, C.S.2    Wazer, D.E.3    Bricault, R.J.4
  • 4
    • 85027219748 scopus 로고    scopus 로고
    • Dose modeling of the AccuBoost brachytherapy system with comparison to standard external beam partial breast irradiation techniques
    • IOBPD3 0360-3016 (in press).
    • S. Sioshansi, M. J. Rivard, J. R. Hiatt, A. A. Hurley, Y. Lee, and D. E. Wazer, " Dose modeling of the AccuBoost brachytherapy system with comparison to standard external beam partial breast irradiation techniques.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 (in press).
    • Int. J. Radiat. Oncol., Biol., Phys.
    • Sioshansi, S.1    Rivard, M.J.2    Hiatt, J.R.3    Hurley, A.A.4    Lee, Y.5    Wazer, D.E.6
  • 5
    • 0019193443 scopus 로고
    • Guidelines for the cancer-related checkup: Recommendations and rationale
    • American Cancer Society, "," CAMCAM 0007-9235,. 10.3322/canjclin.30.4.224
    • American Cancer Society, " Guidelines for the cancer-related checkup: Recommendations and rationale.," Ca-Cancer J. Clin. CAMCAM 0007-9235 30, 224-229 (1980). 10.3322/canjclin.30.4.224
    • (1980) Ca-Cancer J. Clin. , vol.30 , pp. 224-229
  • 6
    • 0025967743 scopus 로고
    • Spectral dependence of glandular tissue dose in screen-film mammography
    • RADLAX 0033-8419.
    • X. Wu, G. T. Barnes, and D. M. Tucker, " Spectral dependence of glandular tissue dose in screen-film mammography.," Radiology RADLAX 0033-8419 179, 143-148 (1991).
    • (1991) Radiology , vol.179 , pp. 143-148
    • Wu, X.1    Barnes, G.T.2    Tucker, D.M.3
  • 7
    • 0020466630 scopus 로고
    • Patterns of breast skin thickness in normal mammograms
    • DOI 10.1016/S0009-9260(82)80407-8
    • S. A. Willson, E. J. Adam, and A. K. Tucker, " Patterns of breast skin thickness in normal mammograms.," Clin. Radiol. CLRAAG 0009-9260 33, 691-693 (1982). 10.1016/S0009-9260(82)80407-8 (Pubitemid 13250796)
    • (1982) Clinical Radiology , vol.33 , Issue.6 , pp. 691-693
    • Willson, S.A.1    Adam, E.J.2    Tucker, A.K.3
  • 8
    • 41449092092 scopus 로고    scopus 로고
    • The effect of skin thickness determined using breast CT on mammographic dosimetry
    • DOI 10.1118/1.2841938
    • S. Huang, J. M. Boone, K. Yang, A. L. C. Kwan, and N. J. Packard, " The effect of skin thickness determined using breast CT on mammographic dosimetry.," Med. Phys. MPHYA6 0094-2405 35, 1199-1204 (2008). 10.1118/1.2841938 (Pubitemid 351457485)
    • (2008) Medical Physics , vol.35 , Issue.4 , pp. 1199-1206
    • Huang, S.-Y.1    Boone, J.M.2    Yang, K.3    Kwan, A.L.C.4    Packard, N.J.5
  • 10
    • 85027240693 scopus 로고    scopus 로고
    • A multi-institutional assessment of the feasibility, implementation, and early clinical results with noninvasive image-guided breast brachytherapy (NIIGBB) for tumor bed boost
    • CNREA8 0008-5472 (in press).
    • S. Hamid, " A multi-institutional assessment of the feasibility, implementation, and early clinical results with noninvasive image-guided breast brachytherapy (NIIGBB) for tumor bed boost.," Cancer Res. CNREA8 0008-5472 (in press).
    • Cancer Res.
    • Hamid, S.1
  • 12
    • 0026029087 scopus 로고
    • Bragg-Gray theory and ion chamber dosimetry for photon beams
    • PHMBA7 0031-9155,. 10.1088/0031-9155/36/4/001
    • C. M. Ma and A. E. Nahum, " Bragg-Gray theory and ion chamber dosimetry for photon beams.," Phys. Med. Biol. PHMBA7 0031-9155 36, 413-428 (1991). 10.1088/0031-9155/36/4/001
    • (1991) Phys. Med. Biol. , vol.36 , pp. 413-428
    • Ma, C.M.1    Nahum, A.E.2
  • 13
    • 33846592289 scopus 로고    scopus 로고
    • 131Cs source
    • DOI 10.1118/1.2432162
    • M. J. Rivard, " Brachytherapy dosimetry parameters calculated for a C 131 s source.," Med. Phys. MPHYA6 0094-2405 34, 754-762 (2007). 10.1118/1.2432162 (Pubitemid 46185155)
    • (2007) Medical Physics , vol.34 , Issue.2 , pp. 754-762
    • Rivard, M.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.