메뉴 건너뛰기




Volumn 43, Issue 3, 1999, Pages 653-661

Comparison of calibration procedures for 192Ir high-dose rate brachytherapy sources

Author keywords

192Ir source calibration; HDR brachytherapy; Solid state phantoms; Well type ionization chambers

Indexed keywords

CESIUM 137; IRIDIUM 192;

EID: 0032972488     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(98)00423-4     Document Type: Article
Times cited : (44)

References (26)
  • 2
    • 0027170982 scopus 로고
    • The half-life of high dose rate Ir-192 sources
    • Podgorsak M.B., DeWerd L.A., Paliwal B.R. The half-life of high dose rate Ir-192 sources. Med Phys. 20:1993;1257-1259.
    • (1993) Med Phys , vol.20 , pp. 1257-1259
    • Podgorsak, M.B.1    DeWerd, L.A.2    Paliwal, B.R.3
  • 5
    • 0008258886 scopus 로고
    • Quality assurance in brachytherapy with special reference to the microSelectron-HDR
    • Special Report No. 2;
    • Baltas D. Quality assurance in brachytherapy with special reference to the microSelectron-HDR. Activity Int Selectron Brachyther J, Special Report No. 2; 1993.
    • (1993) Activity Int Selectron Brachyther J
    • Baltas, D.1
  • 7
    • 0345179936 scopus 로고
    • Messung der Kenndosisleistung punkt- And linienfoermiger HDR 192-Ir Afterloadingstrahler mit einem PMMA-Zylinderphantom
    • Krieger H. Messung der Kenndosisleistung punkt- and linienfoermiger HDR 192-Ir Afterloadingstrahler mit einem PMMA-Zylinderphantom. Z f Med Phys. 1:1991;38-41.
    • (1991) Z F Med Phys , vol.1 , pp. 38-41
    • Krieger, H.1
  • 9
    • 0344317498 scopus 로고
    • Evaluation of calibration techniques for the microSelectron-HDR
    • Ezzell G.A. Evaluation of calibration techniques for the microSelectron-HDR. Activity Selectron User's Newsletter. 1:1989;10-14.
    • (1989) Activity Selectron User's Newsletter , vol.1 , pp. 10-14
    • Ezzell, G.A.1
  • 11
    • 0030801752 scopus 로고    scopus 로고
    • Code of practice for brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 56
    • Nath R., Anderson L.L., Meli J.A., Olch A.J., Stitt J.A., Williamson J.F. Code of practice for brachytherapy physics Report of the AAPM Radiation Therapy Committee Task Group No. 56 . Med Phys. 24:1997;1557-1598.
    • (1997) Med Phys , vol.24 , pp. 1557-1598
    • Nath, R.1    Anderson, L.L.2    Meli, J.A.3    Olch, A.J.4    Stitt, J.A.5    Williamson, J.F.6
  • 12
  • 13
    • 0007954797 scopus 로고
    • Evaluation of calibration techniques for the microSelectron-HDR
    • R.F. Mould. Veenendaal, The Netherlands: Nucletron International
    • Ezzell G.A. Evaluation of calibration techniques for the microSelectron-HDR. Mould R.F. Brachytherapy 2. 1989;61-69 Nucletron International, Veenendaal, The Netherlands.
    • (1989) Brachytherapy 2 , pp. 61-69
    • Ezzell, G.A.1
  • 15
    • 0345179934 scopus 로고
    • Comparison of methods for derivation of iridium-192 calibration factors for the NE 2561 and NE 2571 ionisation chambers
    • Special Report, No.7;
    • Grimbergen TWM, van Dijk E. Comparison of methods for derivation of iridium-192 calibration factors for the NE 2561 and NE 2571 ionisation chambers. Activity Int Selectron Brachyther J, Special Report, No.7; 1995.
    • (1995) Activity Int Selectron Brachyther J
    • Grimbergen, T.W.M.1    Van Dijk, E.2
  • 16
    • 84920315444 scopus 로고
    • Messung kleiner Aktivitaeten mit Teletherapie-Ionisationskammern
    • Pychlau P. Messung kleiner Aktivitaeten mit Teletherapie-Ionisationskammern. Z Med Phys. 1:1991;194-198.
    • (1991) Z Med Phys , vol.1 , pp. 194-198
    • Pychlau, P.1
  • 18
    • 0026658527 scopus 로고
    • 192Ir brachytherapy sources in terms of reference air kerma rate with large volume spherical ionization chambers
    • 192Ir brachytherapy sources in terms of reference air kerma rate with large volume spherical ionization chambers. Phys Med Biol. 37:1992;2071-2082.
    • (1992) Phys Med Biol , vol.37 , pp. 2071-2082
    • Verhaegen, F.1    Van Dijk, E.2    Thierens, H.3    Aalbers, A.4    Seuntjens, J.5
  • 20
    • 0026490741 scopus 로고
    • A new re-entrant ionization chamber for the calibration of iridium-192 high dose rate sources
    • Goetsch S.J., Attix F.H., Dewerd L.A., Thomadsen B.R. A new re-entrant ionization chamber for the calibration of iridium-192 high dose rate sources. Int J Radiat Oncol Biol Phys. 24:1992;167-170.
    • (1992) Int J Radiat Oncol Biol Phys , vol.24 , pp. 167-170
    • Goetsch, S.J.1    Attix, F.H.2    Dewerd, L.A.3    Thomadsen, B.R.4
  • 22
    • 0021646737 scopus 로고
    • ion in the new AAPM radiotherapy dosimetry protocol
    • ion in the new AAPM radiotherapy dosimetry protocol. Med Phys. 11:1984;714-716.
    • (1984) Med Phys , vol.11 , pp. 714-716
    • Attix, F.H.1
  • 25
    • 0026785361 scopus 로고
    • Thermal and scatter effects on the radiation sensitivity of well chambers used for high dose rate Ir-192 calibrations
    • Podgorsak M.B., DeWerd L.A., Thomadsen B.R., Paliwal B.R. Thermal and scatter effects on the radiation sensitivity of well chambers used for high dose rate Ir-192 calibrations. Med Phys. 19:1992;1311-1314.
    • (1992) Med Phys , vol.19 , pp. 1311-1314
    • Podgorsak, M.B.1    DeWerd, L.A.2    Thomadsen, B.R.3    Paliwal, B.R.4
  • 26
    • 84920319617 scopus 로고
    • On the determination of the effective transmission factor for stainless steel ovoid shielding segments and estimation of their shielding efficacy for the clinical situation
    • Verellen D., De Newe W., Van de Heuvel F., Storme G., Coen V., Coghe M. On the determination of the effective transmission factor for stainless steel ovoid shielding segments and estimation of their shielding efficacy for the clinical situation. Med Phys. 21:1991;776-786.
    • (1991) Med Phys , vol.21 , pp. 776-786
    • Verellen, D.1    De Newe, W.2    Van De Heuvel, F.3    Storme, G.4    Coen, V.5    Coghe, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.