-
1
-
-
0036469006
-
Relationship among drug delivery behavior, degradation behavior and morphology of copolylactones derived from glycolide, l-lactide and e{open}-caprolactone
-
Cai Q., Bei J., Wang S. Relationship among drug delivery behavior, degradation behavior and morphology of copolylactones derived from glycolide, l-lactide and e{open}-caprolactone. Polymer Adv Technol 2002, 13:105-111.
-
(2002)
Polymer Adv Technol
, vol.13
, pp. 105-111
-
-
Cai, Q.1
Bei, J.2
Wang, S.3
-
2
-
-
0042388295
-
Randomized study to assess the effectiveness of slow- and moderate-release polymer-based Paclitaxel-eluting stents for coronary artery lesions
-
Colombo A., Drzewiecki J., Banning A., Grube E., Hauptmann K., Silber S., Dudek D., Fort S., Schiele F., Zmudka K., Guagliumi G., Russell M.E. Randomized study to assess the effectiveness of slow- and moderate-release polymer-based Paclitaxel-eluting stents for coronary artery lesions. Circulation 2003, 108:788-794.
-
(2003)
Circulation
, vol.108
, pp. 788-794
-
-
Colombo, A.1
Drzewiecki, J.2
Banning, A.3
Grube, E.4
Hauptmann, K.5
Silber, S.6
Dudek, D.7
Fort, S.8
Schiele, F.9
Zmudka, K.10
Guagliumi, G.11
Russell, M.E.12
-
3
-
-
33646560382
-
-
Cambridge Centre for Medical Materials, Department of Materials Science and Metallurgy, University of Cambridge; The Drug Delivery Companies Report Autumn/Winter
-
Dickers K.J., Milroy G.E., Huatan H., Cameron R.E. The Use of Biodegradable Polymers in Drug Delivery Systems to Provide Pre-Programmed Release 2002, Cambridge Centre for Medical Materials, Department of Materials Science and Metallurgy, University of Cambridge; The Drug Delivery Companies Report Autumn/Winter.
-
(2002)
The Use of Biodegradable Polymers in Drug Delivery Systems to Provide Pre-Programmed Release
-
-
Dickers, K.J.1
Milroy, G.E.2
Huatan, H.3
Cameron, R.E.4
-
4
-
-
34250835092
-
Vascular responses to drug eluting stents importance of delayed healing
-
Finn A.V., Nakazawa G., Joner M., Kolodgie F.D., Mont E.K., Gold H.K., Virmani R. Vascular responses to drug eluting stents importance of delayed healing. Arterioscler Thromb Vasc Biol 2007, 27:1500-1510.
-
(2007)
Arterioscler Thromb Vasc Biol
, vol.27
, pp. 1500-1510
-
-
Finn, A.V.1
Nakazawa, G.2
Joner, M.3
Kolodgie, F.D.4
Mont, E.K.5
Gold, H.K.6
Virmani, R.7
-
6
-
-
33644864730
-
Coronary stenting and inflammation
-
Gaspardone A., Versaci F. Coronary stenting and inflammation. Am J Cardiol 2005, 96:65-70.
-
(2005)
Am J Cardiol
, vol.96
, pp. 65-70
-
-
Gaspardone, A.1
Versaci, F.2
-
7
-
-
0036274835
-
In vivo evaluation of a dexamethasone/PLGA microsphere system designed to suppress the inflammatory tissue response to implantable medical devices
-
Hickey T., Kreutzer D., Burgess D.J., Moussy F. In vivo evaluation of a dexamethasone/PLGA microsphere system designed to suppress the inflammatory tissue response to implantable medical devices. J Biomed Mater Res 2002, 61:180-187.
-
(2002)
J Biomed Mater Res
, vol.61
, pp. 180-187
-
-
Hickey, T.1
Kreutzer, D.2
Burgess, D.J.3
Moussy, F.4
-
8
-
-
0036533085
-
Dexamethasone/PLGA microspheres for continuous delivery of an anti-inflammatory drug for implantable medical devices
-
Hickey T., Kreutzer D., Burgess D.J., Moussy F. Dexamethasone/PLGA microspheres for continuous delivery of an anti-inflammatory drug for implantable medical devices. Biomaterials 2002, 23:1649-1656.
-
(2002)
Biomaterials
, vol.23
, pp. 1649-1656
-
-
Hickey, T.1
Kreutzer, D.2
Burgess, D.J.3
Moussy, F.4
-
9
-
-
73049134701
-
Rate of release of medicaments from ointment bases containing drugs in suspension
-
Higuchi T. Rate of release of medicaments from ointment bases containing drugs in suspension. J Pharm Sci 1961, 50:874-875.
-
(1961)
J Pharm Sci
, vol.50
, pp. 874-875
-
-
Higuchi, T.1
-
10
-
-
3142534579
-
Evaluation of a high-dose dexamethasone-eluting stent
-
Hoffmann R., Langenberg R., Radke P., Franke A., Blindt R., Ortlepp J., et al. Evaluation of a high-dose dexamethasone-eluting stent. Am J Cardiol 2004, 15(94):193-195.
-
(2004)
Am J Cardiol
, vol.15
, Issue.94
, pp. 193-195
-
-
Hoffmann, R.1
Langenberg, R.2
Radke, P.3
Franke, A.4
Blindt, R.5
Ortlepp, J.6
-
11
-
-
0033757955
-
Coronary in-stent restenosis-predictors, treatment and prevention
-
Hoffmann R., Mintz G.S. Coronary in-stent restenosis-predictors, treatment and prevention. Eur Heart J 2000, 21:1739-1749.
-
(2000)
Eur Heart J
, vol.21
, pp. 1739-1749
-
-
Hoffmann, R.1
Mintz, G.S.2
-
12
-
-
33745436151
-
The Taxus™ drug-eluting stent: a new paradigm in controlled drug delivery
-
Kamath K., Barry J., Miller K. The Taxus™ drug-eluting stent: a new paradigm in controlled drug delivery. Adv Drug Deliv Rev 2006, 58:412-436.
-
(2006)
Adv Drug Deliv Rev
, vol.58
, pp. 412-436
-
-
Kamath, K.1
Barry, J.2
Miller, K.3
-
13
-
-
0034648107
-
Are the anti-inflammatory effects of dexamethasone responsible for inhibition of the induction of enzymes involved in prostanoid formation in rat carrageenin induced pleurisy?
-
Kawamura M., Hatanaka K., Saito M., Ogino M., Ono T., Ogino K., Matsuo S., Harada Y. Are the anti-inflammatory effects of dexamethasone responsible for inhibition of the induction of enzymes involved in prostanoid formation in rat carrageenin induced pleurisy?. Eur J Pharmacol 2000, 400:127-135.
-
(2000)
Eur J Pharmacol
, vol.400
, pp. 127-135
-
-
Kawamura, M.1
Hatanaka, K.2
Saito, M.3
Ogino, M.4
Ono, T.5
Ogino, K.6
Matsuo, S.7
Harada, Y.8
-
14
-
-
0020539240
-
Mechanism of solute release from porous hydrophilic polymers
-
Korsmeyer R.W., Gurny R., Doelker E.M., Buri P., Peppas N.A. Mechanism of solute release from porous hydrophilic polymers. Int J Pharm 1983, 15:25-35.
-
(1983)
Int J Pharm
, vol.15
, pp. 25-35
-
-
Korsmeyer, R.W.1
Gurny, R.2
Doelker, E.M.3
Buri, P.4
Peppas, N.A.5
-
15
-
-
28244442188
-
-
The Cardiovascular Research Foundation, New York, NY
-
Leon M.B., Abizaid A., Moses J.W. The CYPHER™ Stent: A New Gold Standard in the Treatment of Coronary Artery Disease 2003, The Cardiovascular Research Foundation, New York, NY, p. 90.
-
(2003)
The CYPHER™ Stent: A New Gold Standard in the Treatment of Coronary Artery Disease
, pp. 90
-
-
Leon, M.B.1
Abizaid, A.2
Moses, J.W.3
-
16
-
-
0345549692
-
Study of anti-restenosis with the BiodivYsio dexamethasone eluting stent (STRIDE)-a multicenter trial
-
Liu X., Hanet C., Vandormael V., Huang Y., De Scheerder I. Study of anti-restenosis with the BiodivYsio dexamethasone eluting stent (STRIDE)-a multicenter trial. Eur Heart J 2002, 23:265.
-
(2002)
Eur Heart J
, vol.23
, pp. 265
-
-
Liu, X.1
Hanet, C.2
Vandormael, V.3
Huang, Y.4
De Scheerder, I.5
-
17
-
-
0032499154
-
In-stent restenosis: the Washington Hospital Center experience
-
Mintz G.S., Hoffmann R., Mehran R., Pichard A.D., Kent K.M., Satler L.F., Popma J.J., Leon M.B. In-stent restenosis: the Washington Hospital Center experience. Am J Cardiol 1998, 81(7):7E-13E.
-
(1998)
Am J Cardiol
, vol.81
, Issue.7
-
-
Mintz, G.S.1
Hoffmann, R.2
Mehran, R.3
Pichard, A.D.4
Kent, K.M.5
Satler, L.F.6
Popma, J.J.7
Leon, M.B.8
-
18
-
-
2542453844
-
Impact of sirolimus-eluting stents on outcome in diabetic patients: a SIRIUS (SIRolImUS-coated Bx velocity balloon expandable stent in the treatment of patients with de novo coronary artery lesions) sub study
-
Moussa I., Leon M.B., Baim D.S., O'Neill W.W., Popma J.J., Buchbinder M., Midwall J., Simonton C.A., Keim E., Wang P., Kuntz R.E., Moses J.W. Impact of sirolimus-eluting stents on outcome in diabetic patients: a SIRIUS (SIRolImUS-coated Bx velocity balloon expandable stent in the treatment of patients with de novo coronary artery lesions) sub study. Circulation 2004, 109:2273-2278.
-
(2004)
Circulation
, vol.109
, pp. 2273-2278
-
-
Moussa, I.1
Leon, M.B.2
Baim, D.S.3
O'Neill, W.W.4
Popma, J.J.5
Buchbinder, M.6
Midwall, J.7
Simonton, C.A.8
Keim, E.9
Wang, P.10
Kuntz, R.E.11
Moses, J.W.12
-
19
-
-
33847284603
-
Scanning electron microscopic analysis of defects in polymer coatings of three commercially available stents: comparison of BiodivYsio, taxus and cypher stents
-
Otsuka Y., Chronos N., Apkarian R., Robinson K. Scanning electron microscopic analysis of defects in polymer coatings of three commercially available stents: comparison of BiodivYsio, taxus and cypher stents. J Invasive Cardiol 2007, 19(2):71-76.
-
(2007)
J Invasive Cardiol
, vol.19
, Issue.2
, pp. 71-76
-
-
Otsuka, Y.1
Chronos, N.2
Apkarian, R.3
Robinson, K.4
-
20
-
-
0021904208
-
Analysis of Fickian and non-Fickian drug release from polymers
-
Peppas N.A. Analysis of Fickian and non-Fickian drug release from polymers. Pharm Acta Helv 1985, 60:110-111.
-
(1985)
Pharm Acta Helv
, vol.60
, pp. 110-111
-
-
Peppas, N.A.1
-
21
-
-
0742289080
-
Dexamethasone and restenosis after coronary stent implantation: new indication for an old drug?
-
Radke P., Weber C., Kaiser A., Schober A., Hoffmann R. Dexamethasone and restenosis after coronary stent implantation: new indication for an old drug?. Curr Pharm Des 2004, 10(4):349-355.
-
(2004)
Curr Pharm Des
, vol.10
, Issue.4
, pp. 349-355
-
-
Radke, P.1
Weber, C.2
Kaiser, A.3
Schober, A.4
Hoffmann, R.5
-
23
-
-
59649091558
-
Avoiding restenosis: is there a role for glucocorticoids in the drug-eluting stent era?
-
Valero S.J., Moreno R., Recalde A.S., Galeote G., Calvo L., Viana A., Lopez de Sá E., Sendón J.L. Avoiding restenosis: is there a role for glucocorticoids in the drug-eluting stent era?. Ther Adv Cardiovasc Dis 2008, 2(3):137-146.
-
(2008)
Ther Adv Cardiovasc Dis
, vol.2
, Issue.3
, pp. 137-146
-
-
Valero, S.J.1
Moreno, R.2
Recalde, A.S.3
Galeote, G.4
Calvo, L.5
Viana, A.6
Lopez de Sá, E.7
Sendón, J.L.8
-
24
-
-
0028223999
-
Local delivery of dexamethasone for prevention of neointimal proliferation in a rat model of balloon angioplasty
-
Villa A.E., Guzman L.A., Chen W., Golomb G., Levy R.J., Topol E.J. Local delivery of dexamethasone for prevention of neointimal proliferation in a rat model of balloon angioplasty. J Clin Invest 1994, 93(3):1243-1249.
-
(1994)
J Clin Invest
, vol.93
, Issue.3
, pp. 1243-1249
-
-
Villa, A.E.1
Guzman, L.A.2
Chen, W.3
Golomb, G.4
Levy, R.J.5
Topol, E.J.6
-
25
-
-
10744229988
-
Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent should we be cautious?
-
Virmani R., Guagliumi G., Farb A., Musumeci G., Grieco N., Motta T., Mihalcsik Tespili L.M., Valsecchi O., Kolodgie F. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent should we be cautious?. Circulation 2004, 109:701-705.
-
(2004)
Circulation
, vol.109
, pp. 701-705
-
-
Virmani, R.1
Guagliumi, G.2
Farb, A.3
Musumeci, G.4
Grieco, N.5
Motta, T.6
Mihalcsik Tespili, L.M.7
Valsecchi, O.8
Kolodgie, F.9
-
26
-
-
61549108883
-
The drug-eluting stent saga
-
Windecker S., Juni P. The drug-eluting stent saga. Circulation 2009, 119:653-656.
-
(2009)
Circulation
, vol.119
, pp. 653-656
-
-
Windecker, S.1
Juni, P.2
-
27
-
-
0030606871
-
Dissolution testing for sustained or controlled release oral dosage forms and correlation with in vivo data: challenges and opportunities
-
Zahirul M., Khan I. Dissolution testing for sustained or controlled release oral dosage forms and correlation with in vivo data: challenges and opportunities. Int J Pharm 1996, 140:131-143.
-
(1996)
Int J Pharm
, vol.140
, pp. 131-143
-
-
Zahirul, M.1
Khan, I.2
|