메뉴 건너뛰기




Volumn 8, Issue 4, 2010, Pages 260-266

Effects of storage time and leucocyte burden of packed and buffy-coat depleted red blood cell units on red cell storage lesion

Author keywords

CD47; Leucocyte burden; Phosphatidylserine; Red cell storage lesion

Indexed keywords

CD47 ANTIGEN; HEMOGLOBIN; LIPOCORTIN 5; PHOSPHATIDYLSERINE; POTASSIUM;

EID: 78049300526     PISSN: 17232007     EISSN: None     Source Type: Journal    
DOI: 10.2450/2009.0131-09     Document Type: Article
Times cited : (21)

References (22)
  • 1
    • 0035051102 scopus 로고    scopus 로고
    • The clinical consequences of the red cell storage lesion
    • Tinmouth A, Chin-Yee I. The clinical consequences of the red cell storage lesion. Transfus Med Rev 2001; 15: 91-107.
    • (2001) Transfus Med Rev , vol.15 , pp. 91-107
    • Tinmouth, A.1    Chin-Yee, I.2
  • 2
    • 0347517729 scopus 로고    scopus 로고
    • Effects of storage on efficacy of red cell transfusion: When is it not safe?
    • Ho J, Sibbald WJ, Chin-Yee IH. Effects of storage on efficacy of red cell transfusion: when is it not safe? Crit Care Med 2003; 31(Suppl 12): S687-97.
    • (2003) Crit Care Med , vol.31 , Issue.SUPPL. 12
    • Ho, J.1    Sibbald, W.J.2    Chin-Yee, I.H.3
  • 3
    • 15244346663 scopus 로고    scopus 로고
    • Red cell storage lesion: The potential impact of storage-induced CD47 decline on immunomodulation and the survival of leucofiltered red cells
    • Bessos H, Seghatchian J. Red cell storage lesion: the potential impact of storage-induced CD47 decline on immunomodulation and the survival of leucofiltered red cells. Transfus Apher Sci 2005; 32: 227-32.
    • (2005) Transfus Apher Sci , vol.32 , pp. 227-232
    • Bessos, H.1    Seghatchian, J.2
  • 4
    • 0033614457 scopus 로고    scopus 로고
    • Detection of phosphatidylserine surface exposure on human erythrocytes using annexin V-Ferrofluid
    • Geldwerth D, Helley D, de Jong K, et al. Detection of phosphatidylserine surface exposure on human erythrocytes using annexin V-Ferrofluid. Biochem Biosphys Res Commun 1999; 258: 199-203.
    • (1999) Biochem Biosphys Res Commun , vol.258 , pp. 199-203
    • Geldwerth, D.1    Helley, D.2    De Jong, K.3
  • 6
    • 0028787014 scopus 로고
    • In vivo expression of alternatively spliced forms of integrin-associated protein (CD47)
    • Reinhold MI, Lindberg FP, Plas D, et al. In vivo expression of alternatively spliced forms of integrin-associated protein (CD47). J Cell Sci 1995; 108: 3419-25.
    • (1995) J Cell Sci , vol.108 , pp. 3419-3425
    • Reinhold, M.I.1    Lindberg, F.P.2    Plas, D.3
  • 7
    • 0035794312 scopus 로고    scopus 로고
    • CD47-signal regulatory protein α (SIRP α) regulates Fcã and complement receptor-mediated phagocytosis
    • Oldenborg P, Gresham H, Lindberg F. CD47-signal regulatory protein α (SIRP α) regulates Fcã and complement receptor-mediated phagocytosis. J Exp Med 2001; 193: 855-61.
    • (2001) J Exp Med , vol.193 , pp. 855-861
    • Oldenborg, P.1    Gresham, H.2    Lindberg, F.3
  • 8
    • 26944444362 scopus 로고    scopus 로고
    • The application of a new quantitative assay for the monitoring of integrin-associated protein CD47 on red blood cells during storage and comparison with the expression of CD47 and phosphatidylserine with flowcytometry
    • Stewart A, Urbaniak S, Turner M, et al. The application of a new quantitative assay for the monitoring of integrin-associated protein CD47 on red blood cells during storage and comparison with the expression of CD47 and phosphatidylserine with flowcytometry. Transfusion 2005; 45: 1496-503.
    • (2005) Transfusion , vol.45 , pp. 1496-1503
    • Stewart, A.1    Urbaniak, S.2    Turner, M.3
  • 9
    • 0029043888 scopus 로고
    • A novel assay for apoptosis. Flow cytometric detection of phosphatidylserine expression on early apoptotic cells using fluorescein labelled annexin V
    • Vermes I, Haanen C, Steffens-Nakken H, et al. A novel assay for apoptosis. Flow cytometric detection of phosphatidylserine expression on early apoptotic cells using fluorescein labelled annexin V. J Immunol Meth 1995; 184: 39-51.
    • (1995) J Immunol Meth , vol.184 , pp. 39-51
    • Vermes, I.1    Haanen, C.2    Steffens-Nakken, H.3
  • 10
    • 0030020463 scopus 로고    scopus 로고
    • Detection of altered membrane phospholipid asymmetry in subpopulations of human red blood cells using fluorescently labelled annexin V
    • Kuypers FA, Lewis RA, Hua M, et al. Detection of altered membrane phospholipid asymmetry in subpopulations of human red blood cells using fluorescently labelled annexin V. Blood 1996; 87:1179-87.
    • (1996) Blood , vol.87 , pp. 1179-1187
    • Kuypers, F.A.1    Lewis, R.A.2    Hua, M.3
  • 11
    • 0019481182 scopus 로고
    • A micro-modification of the Drabkin hemoglobin assay for measuring plasma hemoglobin in the range of 5 to 2000 mg/dl
    • Moore GL, Ledford ME, Merydith A. A micro-modification of the Drabkin hemoglobin assay for measuring plasma hemoglobin in the range of 5 to 2000 mg/dl. Biochem Med 1981;26: 167-73.
    • (1981) Biochem Med , vol.26 , pp. 167-173
    • Moore, G.L.1    Ledford, M.E.2    Merydith, A.3
  • 12
    • 0036144099 scopus 로고    scopus 로고
    • Red blood cell hemolysis during processing
    • Sowemimo-Coker SO. Red blood cell hemolysis during processing. Transfus Med Rev 2002; 16: 46-60.
    • (2002) Transfus Med Rev , vol.16 , pp. 46-60
    • Sowemimo-Coker, S.O.1
  • 13
    • 0036890168 scopus 로고    scopus 로고
    • Expression of CD47 (integrin associated protein) decreases on red blood cells during storage
    • Anniss AM, Sparrow RL. Expression of CD47 (integrin associated protein) decreases on red blood cells during storage. Transfus Apher Sci 2002; 27:233-8.
    • (2002) Transfus Apher Sci , vol.27 , pp. 233-238
    • Anniss, A.M.1    Sparrow, R.L.2
  • 14
    • 27244449485 scopus 로고    scopus 로고
    • Ligation of CD47 mediates phosphatidylserine expression on erythrocytes and a concomitant loss of viability in vitro
    • Head DJ, Lee ZE, Swallah MM, et al. Ligation of CD47 mediates phosphatidylserine expression on erythrocytes and a concomitant loss of viability in vitro. Br J Haematol 2005; 130: 788-90.
    • (2005) Br J Haematol , vol.130 , pp. 788-790
    • Head, D.J.1    Lee, Z.E.2    Swallah, M.M.3
  • 15
    • 0029941957 scopus 로고    scopus 로고
    • Glutamine and phosphate-containing hypotonic storage media better maintain erythrocyte membrane physical properties
    • Dumaswala UJ, Wilson MJ, Jose T, Daleke DL. Glutamine and phosphate-containing hypotonic storage media better maintain erythrocyte membrane physical properties. Blood 1996; 88: 697-704.
    • (1996) Blood , vol.88 , pp. 697-704
    • Dumaswala, U.J.1    Wilson, M.J.2    Jose, T.3    Daleke, D.L.4
  • 16
    • 32344450806 scopus 로고    scopus 로고
    • Red blood cell age determines the impact of storage and leukocyte burden on cell adhesion molecules, glycophorin A and the release of annexin V
    • Sparrow RL, Healey G, Patton KA, Veale MF. Red blood cell age determines the impact of storage and leukocyte burden on cell adhesion molecules, glycophorin A and the release of annexin V. Transfus Apher Sci 2006; 34:15-23.
    • (2006) Transfus Apher Sci , vol.34 , pp. 15-23
    • Sparrow, R.L.1    Healey, G.2    Patton, K.A.3    Veale, M.F.4
  • 17
    • 71849103855 scopus 로고    scopus 로고
    • Red blood cell hemolysis during blood bank storage: Using national quality management data to answer basic scientific questions
    • doi: 10.1111/j.1537-2995.2009.02275.x
    • Hess JR, Sparrow RL, van der Meer PF, et al. Red blood cell hemolysis during blood bank storage: using national quality management data to answer basic scientific questions. Transfusion 2009: doi: 10.1111/j.1537-2995.2009. 02275.x
    • (2009) Transfusion
    • Hess, J.R.1    Sparrow, R.L.2    Van Der Meer, P.F.3
  • 18
    • 0035991924 scopus 로고    scopus 로고
    • Development of a microplate method for the measurement of plasma haemoglobin and its use in monitoring the storage lesion of red cell components
    • DOI 10.1016/S1473-0502(01)00139-2, PII S1473050201001392
    • Seghatchian MJ, Krailadsiri P, Beard M, et al. Development of a microplate method for the measurement of plasma haemoglobin and its use in monitoring the storage lesion of red cell components. Transfus Apher Sci 2002; 26: 91-3. (Pubitemid 34135399)
    • (2002) Transfusion and Apheresis Science , vol.26 , Issue.1 , pp. 91-93
    • Seghatchian, J.1    Krailadsiri, P.2    Beard, M.3    Vickers, M.4
  • 19
    • 0036217472 scopus 로고    scopus 로고
    • Red cell storage lesion assessed by the levels of potassium, haemoglobin and annexin V in supernatants
    • Seghatchian MJ, Krailadsiri P. Red cell storage lesion assessed by the levels of potassium, haemoglobin and annexin V in supernatants. Transfus Apher Sci 2002; 26: 139-43.
    • (2002) Transfus Apher Sci , vol.26 , pp. 139-143
    • Seghatchian, M.J.1    Krailadsiri, P.2
  • 20
    • 34548181867 scopus 로고    scopus 로고
    • Proteomic analysis of RBC membrane protein degradation during blood Storage
    • D'Amici GM, Rinalducci S, Zolla L. Proteomic analysis of RBC membrane protein degradation during blood Storage. Journal of Proteome Research 2007; 6: 3242-55.
    • (2007) Journal of Proteome Research , vol.6 , pp. 3242-3255
    • D'Amici, G.M.1    Rinalducci, S.2    Zolla, L.3
  • 21
    • 33750309979 scopus 로고    scopus 로고
    • Clinical consequences of red cell storage in the critically ill
    • Tinmouth A, Fergusson D, Chin Yee I, et al. Clinical consequences of red cell storage in the critically ill. Transfusion 2006; 46: 2014-27.
    • (2006) Transfusion , vol.46 , pp. 2014-2027
    • Tinmouth, A.1    Fergusson, D.2    Chin Yee, I.3
  • 22
    • 67649979539 scopus 로고    scopus 로고
    • Association between duration of storage of transfused red blood cells and morbidity and mortality in adult patients: Myth or reality?
    • Lelubre C, Piagnerelli M, Vincent JL. Association between duration of storage of transfused red blood cells and morbidity and mortality in adult patients: myth or reality? Transfusion 2009; 49: 1384-94.
    • (2009) Transfusion , vol.49 , pp. 1384-1394
    • Lelubre, C.1    Piagnerelli, M.2    Vincent, J.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.