Volumn 34, Issue 10, 2010, Pages 816-827

Interaction of an idealized cavopulmonary circulation with mechanical circulatory assist using an intravascular rotary blood pump

Author keywords

Artificial right ventricle; Blood pump; Cavopulmonary assist device; Fontan conversion; Heart pump; Intravascular blood pump; Mechanical cavopulmonary assist; Pediatric circulatory support; Single ventricle physiology; Ventricular assist device(s)

Indexed keywords

ARTIFICIAL HEART; BLOOD; COMPUTATIONAL FLUID DYNAMICS; DAMAGE DETECTION; FIBER OPTIC SENSORS; HEMODYNAMICS; IMPELLERS; LEFT VENTRICULAR ASSIST DEVICES; VISCOSITY;

EID: 77958591641     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2010.01080.x     Document Type: Article
Times cited : (13)

References (28)
  • 1
    • 33749022325 scopus 로고    scopus 로고
    • March of Dimes Global Report on Birth Defects: The Hidden Toll of Dying and Disabled Children
    • White Plains, NY: March of Dimes Birth Defects Foundation
    • Christianson A, Howson CP, Modell B. March of Dimes Global Report on Birth Defects: The Hidden Toll of Dying and Disabled Children. White Plains, NY: March of Dimes Birth Defects Foundation, 2006.
    • (2006)
    • Christianson, A.1    Howson, C.P.2    Modell, B.3
  • 2
    • 33745700334 scopus 로고    scopus 로고
    • Comparison of the non-invasive methods estimating dry weight in hemodialysis patients
    • Kayatas M, Ozdemir N, Muderrisoglu H, Ulucam M, Turan M, Hizel N. Comparison of the non-invasive methods estimating dry weight in hemodialysis patients. Ren Fail 2006;28:217-22.
    • (2006) Ren Fail , vol.28 , pp. 217-222
    • Kayatas, M.1    Ozdemir, N.2    Muderrisoglu, H.3    Ulucam, M.4    Turan, M.5    Hizel, N.6
  • 3
    • 0034351080 scopus 로고    scopus 로고
    • Fluid mechanic assessment of the total cavopulmoary connection using magnetic resonance phase velocity mapping and digital particle image velocimetry
    • Ensley AE, Ramuzat A, Healy TM, et al. Fluid mechanic assessment of the total cavopulmoary connection using magnetic resonance phase velocity mapping and digital particle image velocimetry. Ann Biomed Eng 2000;28:1172-83.
    • (2000) Ann Biomed Eng , vol.28 , pp. 1172-1183
    • Ensley, A.E.1    Ramuzat, A.2    Healy, T.M.3
  • 4
    • 33847316535 scopus 로고    scopus 로고
    • Factors influencing early and late outcome following the Fontan procedure in the current era. The Two Commandments?
    • Hosein R, Clarke AJB, McGuirk SP, et al. Factors influencing early and late outcome following the Fontan procedure in the current era. The Two Commandments? Eur J Cardiothorac Surg 2007;31:344-53.
    • (2007) Eur J Cardiothorac Surg , vol.31 , pp. 344-353
    • Hosein, R.1    Clarke, A.J.B.2    McGuirk, S.P.3
  • 5
    • 0034747384 scopus 로고    scopus 로고
    • Importance of accurate geometry in the study of the total cavopulmonary connection: computational simulations and in vitro experiments
    • Ryu K, Healy TM, Ensley AE, Sharma S, Lucas C, Yoganathan AP. Importance of accurate geometry in the study of the total cavopulmonary connection: computational simulations and in vitro experiments. Ann Biomed Eng 2001;29:844-53.
    • (2001) Ann Biomed Eng , vol.29 , pp. 844-853
    • Ryu, K.1    Healy, T.M.2    Ensley, A.E.3    Sharma, S.4    Lucas, C.5    Yoganathan, A.P.6
  • 6
    • 59549095868 scopus 로고    scopus 로고
    • Mechanical axial flow blood pump to support the cavopulmonary circulation
    • Throckmorton AL, Kapadia J, Madduri D. Mechanical axial flow blood pump to support the cavopulmonary circulation. Int J Artif Organs 2008;31:970-82.
    • (2008) Int J Artif Organs , vol.31 , pp. 970-982
    • Throckmorton, A.L.1    Kapadia, J.2    Madduri, D.3
  • 7
    • 0030866886 scopus 로고    scopus 로고
    • Fontan operation in five hundred consecutive patients: factors influencing early and late outcome
    • Gentles TL, Mayer JE, Gauvreau K, et al. Fontan operation in five hundred consecutive patients: factors influencing early and late outcome. J Thorac Cardiovasc Surg 1997;114:376-91.
    • (1997) J Thorac Cardiovasc Surg , vol.114 , pp. 376-391
    • Gentles, T.L.1    Mayer, J.E.2    Gauvreau, K.3
  • 8
    • 0034532458 scopus 로고    scopus 로고
    • Short-Term bridge to transplant using the BVS 5000 in a 22-kg child
    • Sadeghi AM, Marelli D, Talamo M, Fazio D, Laks H. Short-Term bridge to transplant using the BVS 5000 in a 22-kg child. Ann Thorac Surg 2000;70:2152-3.
    • (2000) Ann Thorac Surg , vol.70 , pp. 2152-2153
    • Sadeghi, A.M.1    Marelli, D.2    Talamo, M.3    Fazio, D.4    Laks, H.5
  • 9
    • 33744986238 scopus 로고    scopus 로고
    • Cardiac rest and reserve function in patients with Fontan circulation
    • Senzaki H, Masutani S, Ishido H, et al. Cardiac rest and reserve function in patients with Fontan circulation. J Am Coll Cardiol 2006;47:2528-35.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 2528-2535
    • Senzaki, H.1    Masutani, S.2    Ishido, H.3
  • 11
    • 70450267398 scopus 로고    scopus 로고
    • Intravascular mechanical cavopulmonary assistance for patients with failing fontan physiology
    • Bhavsar S, Kapadia J, Chopski S, Throckmorton AL. Intravascular mechanical cavopulmonary assistance for patients with failing fontan physiology. Artif Organs 2009;33:977-87.
    • (2009) Artif Organs , vol.33 , pp. 977-987
    • Bhavsar, S.1    Kapadia, J.2    Chopski, S.3    Throckmorton, A.L.4
  • 12
    • 68549118733 scopus 로고    scopus 로고
    • Design of a protective cage of filaments for an axial flow blood pump for intravascular cavopulmonary assist
    • Throckmorton AL, Kishore RA. Design of a protective cage of filaments for an axial flow blood pump for intravascular cavopulmonary assist. Artif Organs 2009;33:611-21.
    • (2009) Artif Organs , vol.33 , pp. 611-621
    • Throckmorton, A.L.1    Kishore, R.A.2
  • 13
    • 11144347532 scopus 로고    scopus 로고
    • Quantitative evaluation of blood damage in a centrifugal VAD by computational fluid dynamics
    • Song X, Throckmorton AL, Wood HG, Antaki JF, Olsen DB. Quantitative evaluation of blood damage in a centrifugal VAD by computational fluid dynamics. J Fluids Engineering 2004;126:410-8.
    • (2004) J Fluids Engineering , vol.126 , pp. 410-418
    • Song, X.1    Throckmorton, A.L.2    Wood, H.G.3    Antaki, J.F.4    Olsen, D.B.5
  • 14
    • 0031922692 scopus 로고    scopus 로고
    • Computational fluid dynamic analyses to establish design process of centrifugal blood pumps
    • Miyazoe Y, Sawairi T, Ito K, et al. Computational fluid dynamic analyses to establish design process of centrifugal blood pumps. Artif Organs 1998;23:381-5.
    • (1998) Artif Organs , vol.23 , pp. 381-385
    • Miyazoe, Y.1    Sawairi, T.2    Ito, K.3
  • 15
    • 15144343373 scopus 로고    scopus 로고
    • Development of design methods of a centrifugal blood pump with in vitro tests, flow visualization, and computational fluid dynamics: results in hemolysis tests
    • Takiura K, Masuzawa T, Endo S, et al. Development of design methods of a centrifugal blood pump with in vitro tests, flow visualization, and computational fluid dynamics: results in hemolysis tests. Artif Organs 1998;22:393-8.
    • (1998) Artif Organs , vol.22 , pp. 393-398
    • Takiura, K.1    Masuzawa, T.2    Endo, S.3
  • 16
    • 36549056164 scopus 로고    scopus 로고
    • Numerical design and experimental hydraulic testing of an axial flow VAD for infants and children
    • Throckmorton AL, Untaroiu A, Allaire PE, et al. Numerical design and experimental hydraulic testing of an axial flow VAD for infants and children. ASAIO J 2007;53:754-61.
    • (2007) ASAIO J , vol.53 , pp. 754-761
    • Throckmorton, A.L.1    Untaroiu, A.2    Allaire, P.E.3
  • 17
    • 19144362523 scopus 로고    scopus 로고
    • Advances of CFD in Fluid Machinery Design
    • New Jersey: John Wiley and Sons, Inc.
    • Elder R, Tourlidakis A, Yates M. Advances of CFD in Fluid Machinery Design. New Jersey: John Wiley and Sons, Inc., 2003.
    • (2003)
    • Elder, R.1    Tourlidakis, A.2    Yates, M.3
  • 18
    • 26444484968 scopus 로고    scopus 로고
    • Viscoelasticity of pediatric blood and its implications for the testing of a pulsatile blood pump
    • Long JA, Undar U, Manning KB, Deutsch S. Viscoelasticity of pediatric blood and its implications for the testing of a pulsatile blood pump. ASAIO J 2005;51:563-6.
    • (2005) ASAIO J , vol.51 , pp. 563-566
    • Long, J.A.1    Undar, U.2    Manning, K.B.3    Deutsch, S.4
  • 19
    • 33644993283 scopus 로고    scopus 로고
    • Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump
    • Zhang J, Gellman B, Koert A, et al. Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump. Artif Organs 2006;30:168-77.
    • (2006) Artif Organs , vol.30 , pp. 168-177
    • Zhang, J.1    Gellman, B.2    Koert, A.3
  • 20
    • 0029085081 scopus 로고
    • Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump
    • Bludszuweit C. Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump. Artif Organs 1995;19:590-6.
    • (1995) Artif Organs , vol.19 , pp. 590-596
    • Bludszuweit, C.1
  • 22
    • 0019186014 scopus 로고
    • A couette viscometer for short time shearing in blood
    • Heuser G, Opitz R. A couette viscometer for short time shearing in blood. Biorheology 1980;17:17-24.
    • (1980) Biorheology , vol.17 , pp. 17-24
    • Heuser, G.1    Opitz, R.2
  • 23
    • 0242333304 scopus 로고    scopus 로고
    • Computational fluid dynamics prediction of blood damage in a centrifugal pump
    • Song X, Throckmorton AL, Wood HG, Antaki JF, Olsen DB. Computational fluid dynamics prediction of blood damage in a centrifugal pump. Artif Organs 2003;27:938-41.
    • (2003) Artif Organs , vol.27 , pp. 938-941
    • Song, X.1    Throckmorton, A.L.2    Wood, H.G.3    Antaki, J.F.4    Olsen, D.B.5
  • 24
    • 0034427012 scopus 로고    scopus 로고
    • Prediction of hemolysis in rotary blood pumps with computational fluid dynamics analysis
    • Mitamura Y, Nakamura H, Sekine K. Prediction of hemolysis in rotary blood pumps with computational fluid dynamics analysis. J Circulatory Support 2000;1:1-6.
    • (2000) J Circulatory Support , vol.1 , pp. 1-6
    • Mitamura, Y.1    Nakamura, H.2    Sekine, K.3
  • 25
    • 33646168598 scopus 로고    scopus 로고
    • Mechanical support of the functionally single ventricle
    • Ravishankar C, Gaynor JW. Mechanical support of the functionally single ventricle. Cardiol Young 2000;16:55-60.
    • (2000) Cardiol Young , vol.16 , pp. 55-60
    • Ravishankar, C.1    Gaynor, J.W.2
  • 26
    • 0344665459 scopus 로고    scopus 로고
    • Cavopulmonary assist: circulatory support for the univentricular Fontan circulation
    • Rodefeld M, Boyd JH, LaLone BJ, et al. Cavopulmonary assist: circulatory support for the univentricular Fontan circulation. Ann Thorac Surg 2003;76:1911-6.
    • (2003) Ann Thorac Surg , vol.76 , pp. 1911-1916
    • Rodefeld, M.1    Boyd, J.H.2    LaLone, B.J.3
  • 27
    • 55949089133 scopus 로고    scopus 로고
    • Pediatric circulatory support systems: current strategies and future directions. Biventricular and univentricular mechanical assistance
    • Throckmorton AL, Chopski SG. Pediatric circulatory support systems: current strategies and future directions. Biventricular and univentricular mechanical assistance. ASAIO J 2008;54:491-7.
    • (2008) ASAIO J , vol.54 , pp. 491-497
    • Throckmorton, A.L.1    Chopski, S.G.2
  • 28
    • 34748833584 scopus 로고    scopus 로고
    • Nonlinear power loss during exercise in single-ventricle patient after the Fontan: insights from computational fluid dynamics
    • Whitehead KK, Pekkan K, Kitajima HD, Paridon SM, Yoganathan AP, Fogel MA. Nonlinear power loss during exercise in single-ventricle patient after the Fontan: insights from computational fluid dynamics. Circulation 2007;116(Suppl. 1):I165-71.
    • (2007) Circulation , vol.116 , Issue.SUPPL. 1
    • Whitehead, K.K.1    Pekkan, K.2    Kitajima, H.D.3    Paridon, S.M.4    Yoganathan, A.P.5    Fogel, M.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.