메뉴 건너뛰기




Volumn 28, Issue 10, 2000, Pages 1172-1183

Fluid mechanic assessment of the total cavopulmonary connection using magnetic resonance phase velocity mapping and digital particle image velocimetry

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; FLOW PATTERNS; FLOW VISUALIZATION; FUNCTIONAL ASSESSMENT; HEART VALVE PROSTHESES; HEMODYNAMICS; MAGNETIC RESONANCE IMAGING; MEDICAL IMAGING;

EID: 0034351080     PISSN: 00906964     EISSN: None     Source Type: Journal    
DOI: 10.1114/1.1317533     Document Type: Article
Times cited : (46)

References (19)
  • 1
    • 0030220032 scopus 로고    scopus 로고
    • Steady flow in an aneurysm model: Correlation between fluid dynamics and blood platelet deposition
    • Bluestein, D., L. Niu, R. Schoephoerster, and M. Dewanjee. Steady flow in an aneurysm model: Correlation between fluid dynamics and blood platelet deposition. J. Biomech. Eng. 118:280-286, 1996.
    • (1996) J. Biomech. Eng. , vol.118 , pp. 280-286
    • Bluestein, D.1    Niu, L.2    Schoephoerster, R.3    Dewanjee, M.4
  • 2
    • 0021282475 scopus 로고
    • Measurement of flow with NMR imaging using a gradient pulse and phase difference technique
    • Bryant, D., J. Payne, D. Firmin, and D. Longmore. Measurement of flow with NMR imaging using a gradient pulse and phase difference technique. J. Comput. Assist. Tomogr. 8:588-593, 1984.
    • (1984) J. Comput. Assist. Tomogr. , vol.8 , pp. 588-593
    • Bryant, D.1    Payne, J.2    Firmin, D.3    Longmore, D.4
  • 3
    • 0030854497 scopus 로고    scopus 로고
    • The importance of slice location on the accuracy of aortic regurgitation measurements with magnetic resonance phase velocity mapping
    • Chatzimavroudis, G., P. Walker, J. Oshinski, R. Franch, R. Pettigrew, and A. Yoganathan. The importance of slice location on the accuracy of aortic regurgitation measurements with magnetic resonance phase velocity mapping. Ann. Biomed. Eng. 25:644-652, 1997.
    • (1997) Ann. Biomed. Eng. , vol.25 , pp. 644-652
    • Chatzimavroudis, G.1    Walker, P.2    Oshinski, J.3    Franch, R.4    Pettigrew, R.5    Yoganathan, A.6
  • 6
    • 0015060609 scopus 로고
    • Surgical repair of tricuspid atresia
    • Fontan, F., and E. Baudet. Surgical repair of tricuspid atresia. Thorax 26:240-248, 1971.
    • (1971) Thorax , vol.26 , pp. 240-248
    • Fontan, F.1    Baudet, E.2
  • 7
    • 0032440508 scopus 로고    scopus 로고
    • Development of wall surface tangent DPIV measurement techniques for arterial branch models
    • Karn, E., S. Beale, A. Duitino, T. Wei, A. Graham, and G. Nackman. Development of wall surface tangent DPIV measurement techniques for arterial branch models. J. Biomech. Eng. 120:784-787, 1998.
    • (1998) J. Biomech. Eng. , vol.120 , pp. 784-787
    • Karn, E.1    Beale, S.2    Duitino, A.3    Wei, T.4    Graham, A.5    Nackman, G.6
  • 9
    • 0029004853 scopus 로고
    • Modification of the Fontan procedure: Superior vena cava to left pulmonary artery connection and inferior vena cava to right pulmonary artery connection with adjustable atrial septal defect
    • Laks, H., A. Ardehali, P. W. Grant, L. Permut, A. Aharon, M. Kuhn, J. Isabel-Jones, and A. Galindo. Modification of the Fontan procedure: Superior vena cava to left pulmonary artery connection and inferior vena cava to right pulmonary artery connection with adjustable atrial septal defect. Circulation 91:2943-2947, 1995.
    • (1995) Circulation , vol.91 , pp. 2943-2947
    • Laks, H.1    Ardehali, A.2    Grant, P.W.3    Permut, L.4    Aharon, A.5    Kuhn, M.6    Isabel-Jones, J.7    Galindo, A.8
  • 10
    • 0023709443 scopus 로고
    • Total cavopulmonary connection: A logical alternative to atriopulmonary connection for complex Fontan operations
    • de Leval, M. R., P. Kilner, M. Gewillig, and C. Bull. Total cavopulmonary connection: A logical alternative to atriopulmonary connection for complex Fontan operations. J. Thorac. Cardiovasc. Surg. 96:682-695, 1988.
    • (1988) J. Thorac. Cardiovasc. Surg. , vol.96 , pp. 682-695
    • De Leval, M.R.1    Kilner, P.2    Gewillig, M.3    Bull, C.4
  • 11
    • 0031029322 scopus 로고    scopus 로고
    • Steady flow velocity field and turbulent stress mappings downstream of a porcine bioprosthetic aortic valve in vitro
    • Lim, W., Y. Chew, T. Chew, and H. Low. Steady flow velocity field and turbulent stress mappings downstream of a porcine bioprosthetic aortic valve in vitro. Ann. Biomed. Eng. 25:86-95, 1997.
    • (1997) Ann. Biomed. Eng. , vol.25 , pp. 86-95
    • Lim, W.1    Chew, Y.2    Chew, T.3    Low, H.4
  • 12
    • 0020387008 scopus 로고
    • Orthoterminal correction of congenital heart disease: Double cava-pulmonary anastomosis
    • Lins, R., M. Lins, C. Cavalcanti, R. Miranda, and J. Mota. Orthoterminal correction of congenital heart disease: Double cava-pulmonary anastomosis. J. Thorac. Cardiovasc. Surg. 84:633-635, 1982.
    • (1982) J. Thorac. Cardiovasc. Surg. , vol.84 , pp. 633-635
    • Lins, R.1    Lins, M.2    Cavalcanti, C.3    Miranda, R.4    Mota, J.5
  • 13
    • 0023679091 scopus 로고
    • Quantitative flow measurements on phantoms and on blood vessels with MR
    • Meier, D., S. Maier, and P. Bosiger. Quantitative flow measurements on phantoms and on blood vessels with MR. Magn. Reson. Rev. 8:25-34, 1988.
    • (1988) Magn. Reson. Rev. , vol.8 , pp. 25-34
    • Meier, D.1    Maier, S.2    Bosiger, P.3
  • 15
    • 0032601365 scopus 로고    scopus 로고
    • Fluid dynamic optimization of a ventricular assist device using particle image velocimetry
    • Mussivand, T., K. Day, and B. Naber. Fluid dynamic optimization of a ventricular assist device using particle image velocimetry. ASAIO J. 45:25-31, 1999.
    • (1999) ASAIO J. , vol.45 , pp. 25-31
    • Mussivand, T.1    Day, K.2    Naber, B.3
  • 17
    • 0029942604 scopus 로고    scopus 로고
    • In vitro flow experiments for determination of optimal geometry of total cavopulmonary connection for surgical repair of children with functional single ventricle
    • Sharma, S., S. Goudy, P. Walker, S. Panchal, A. Ensley, K. Kanter, V. Tam, D. Fyfe, and A. Yoganathan. In vitro flow experiments for determination of optimal geometry of total cavopulmonary connection for surgical repair of children with functional single ventricle. J. Am. Coll. Cardiol. 27:1264-1269, 1996.
    • (1996) J. Am. Coll. Cardiol. , vol.27 , pp. 1264-1269
    • Sharma, S.1    Goudy, S.2    Walker, P.3    Panchal, S.4    Ensley, A.5    Kanter, K.6    Tam, V.7    Fyfe, D.8    Yoganathan, A.9
  • 18
    • 0027948393 scopus 로고
    • Three-dimensional visualization of velocity profiles in the human main pulmonary artery with magnetic resonance phase velocity mapping
    • Sloth, E., K. Houlind, S. Oyre, W. Kim, E. Pedersen, H. Jorgensen, and J. Hasenkam. Three-dimensional visualization of velocity profiles in the human main pulmonary artery with magnetic resonance phase velocity mapping. Am. Heart J. 128:1130-1138, 1994.
    • (1994) Am. Heart J. , vol.128 , pp. 1130-1138
    • Sloth, E.1    Houlind, K.2    Oyre, S.3    Kim, W.4    Pedersen, E.5    Jorgensen, H.6    Hasenkam, J.7
  • 19
    • 0025792678 scopus 로고
    • Digital particle image velocimetry
    • Willert, C., and M. Gharib. Digital particle image velocimetry. Exp. Fluids 10:181-193, 1991.
    • (1991) Exp. Fluids , vol.10 , pp. 181-193
    • Willert, C.1    Gharib, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.