메뉴 건너뛰기




Volumn 86, Issue 4, 2008, Pages 1343-1347

Performance of a 3-Bladed Propeller Pump to Provide Cavopulmonary Assist in the Failing Fontan Circulation

Author keywords

[No Author keywords available]

Indexed keywords

HEMOGLOBIN;

EID: 52249101776     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2008.06.026     Document Type: Article
Times cited : (41)

References (9)
  • 4
    • 36549087344 scopus 로고    scopus 로고
    • Mechanical cavopulmonary assist for the univentricular Fontan circulation using a novel folding propeller blood pump
    • Throckmorton A.L., Myers C.D., Ballman K.K., Frankel S.H., Litwak K., and Rodefeld M.D. Mechanical cavopulmonary assist for the univentricular Fontan circulation using a novel folding propeller blood pump. ASAIO J 53 (2007) 734-741
    • (2007) ASAIO J , vol.53 , pp. 734-741
    • Throckmorton, A.L.1    Myers, C.D.2    Ballman, K.K.3    Frankel, S.H.4    Litwak, K.5    Rodefeld, M.D.6
  • 5
    • 0027162867 scopus 로고
    • In vitro hematological testing of rotary blood pumps: remarks on standardization and data interpretation
    • Mueller M.R., Schima H., Engelhardt H., et al. In vitro hematological testing of rotary blood pumps: remarks on standardization and data interpretation. Artif Organs 17 (1993) 103-110
    • (1993) Artif Organs , vol.17 , pp. 103-110
    • Mueller, M.R.1    Schima, H.2    Engelhardt, H.3
  • 6
    • 33846927942 scopus 로고    scopus 로고
    • Characteristics of Doppler myocardial echocardiography in patients with tricuspid atresia after total cavopulmonary connection with preserved systolic ventricular function
    • Eicken A., Petzuch K., Marek J., et al. Characteristics of Doppler myocardial echocardiography in patients with tricuspid atresia after total cavopulmonary connection with preserved systolic ventricular function. Int J Cardiol 116 (2007) 212-218
    • (2007) Int J Cardiol , vol.116 , pp. 212-218
    • Eicken, A.1    Petzuch, K.2    Marek, J.3
  • 7
    • 0023692556 scopus 로고
    • In vivo evaluation of a peripheral vascular access axial flow blood pump
    • Wampler R.K., Moise J.C., Frazier O.H., and Olsen D.B. In vivo evaluation of a peripheral vascular access axial flow blood pump. ASAIO Trans 34 (1988) 450-454
    • (1988) ASAIO Trans , vol.34 , pp. 450-454
    • Wampler, R.K.1    Moise, J.C.2    Frazier, O.H.3    Olsen, D.B.4
  • 8
    • 33751212454 scopus 로고    scopus 로고
    • Initial experience with the development and numerical and in vitro studies of a novel low-pressure artificial right ventricle for pediatric Fontan patients
    • Wang R., Lacour-Gayet F.G., Lanning C.J., et al. Initial experience with the development and numerical and in vitro studies of a novel low-pressure artificial right ventricle for pediatric Fontan patients. ASAIO J 52 (2006) 682-692
    • (2006) ASAIO J , vol.52 , pp. 682-692
    • Wang, R.1    Lacour-Gayet, F.G.2    Lanning, C.J.3
  • 9
    • 0242426513 scopus 로고    scopus 로고
    • Hemodynamic effects of a new percutaneous circulatory support device in a left ventricular failure model
    • Reitan O., Steen S., and Ohlin H. Hemodynamic effects of a new percutaneous circulatory support device in a left ventricular failure model. ASAIO J 49 (2003) 731-736
    • (2003) ASAIO J , vol.49 , pp. 731-736
    • Reitan, O.1    Steen, S.2    Ohlin, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.