메뉴 건너뛰기




Volumn 10, Issue 11, 2010, Pages 1024-1031

In vitro biomechanics of an expandable vertebral body replacement with self-adjusting end plates

Author keywords

Biomechanics; Corpectomy; Spinal fracture; Vertebral body replacement; Vertebral end plate

Indexed keywords

ADULT; ALLOGRAFT; ARTICLE; BIOMECHANICS; BONE ALLOGRAFT; BONE REMODELING; CONTROLLED STUDY; DEVICE; FRACTURE FIXATION; HUMAN; IN VITRO STUDY; JOINT MOBILITY; MEDICAL INSTRUMENTATION; NERVE ENDING; PEDICLE SCREW; PRIORITY JOURNAL; RANGE OF MOTION; RIGIDITY; SPINE SURGERY; STATISTICAL SIGNIFICANCE; THORACOLUMBAR SPINE; VERTEBRA BODY; VERTEBRAL BODY REPLACEMENT;

EID: 77958555451     PISSN: 15299430     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.spinee.2010.08.017     Document Type: Article
Times cited : (11)

References (52)
  • 1
    • 0021933606 scopus 로고
    • Anterior decompression of traumatic thoracolumbar fractures with incomplete neurological deficit using a retroperitoneal approach
    • P.C. McAfee, H.H. Bohlman, and H.A. Yuan Anterior decompression of traumatic thoracolumbar fractures with incomplete neurological deficit using a retroperitoneal approach J Bone Joint Surg Am 67 1985 89 104
    • (1985) J Bone Joint Surg Am , vol.67 , pp. 89-104
    • McAfee, P.C.1    Bohlman, H.H.2    Yuan, H.A.3
  • 2
    • 4444350486 scopus 로고    scopus 로고
    • The management of acute thoracolumbar burst fractures with anterior corpectomy and Z-plate fixation
    • P.W. McDonough, R. Davis, and C. Tribus The management of acute thoracolumbar burst fractures with anterior corpectomy and Z-plate fixation Spine 29 2004 1901 1908
    • (2004) Spine , vol.29 , pp. 1901-1908
    • McDonough, P.W.1    Davis, R.2    Tribus, C.3
  • 3
    • 21344447018 scopus 로고    scopus 로고
    • Anterior-only stabilization of three-column thoracolumbar injuries
    • R.C. Sasso, N.M. Best, and T.M. Reilly Anterior-only stabilization of three-column thoracolumbar injuries J Spinal Disord Tech 18 Suppl 2005 S7 S14
    • (2005) J Spinal Disord Tech , vol.18 , Issue.SUPPL.
    • Sasso, R.C.1    Best, N.M.2    Reilly, T.M.3
  • 4
    • 0031016431 scopus 로고    scopus 로고
    • Selection criteria and outcome of operative approaches for thoracolumbar burst fractures with and without neurological deficit
    • C.L. Schnee, and L.V. Ansell Selection criteria and outcome of operative approaches for thoracolumbar burst fractures with and without neurological deficit J Neurosurg 86 1997 48 55
    • (1997) J Neurosurg , vol.86 , pp. 48-55
    • Schnee, C.L.1    Ansell, L.V.2
  • 5
    • 0029039843 scopus 로고
    • Anterior stabilization of thoracolumbar burst fractures using the Kaneda device: A preliminary report
    • J.S. Kirkpatrick, R.G. Wilber, and M. Likavec Anterior stabilization of thoracolumbar burst fractures using the Kaneda device: a preliminary report Orthopedics 18 1995 673 678
    • (1995) Orthopedics , vol.18 , pp. 673-678
    • Kirkpatrick, J.S.1    Wilber, R.G.2    Likavec, M.3
  • 6
    • 34250614763 scopus 로고    scopus 로고
    • Two column lesions in the thoracolumbar junction: Anterior, posterior or combined approach? A comparative biomechanical in vitro investigation
    • T. Bence, U. Schreiber, and T. Grupp Two column lesions in the thoracolumbar junction: anterior, posterior or combined approach? A comparative biomechanical in vitro investigation Eur Spine J 16 2007 813 820
    • (2007) Eur Spine J , vol.16 , pp. 813-820
    • Bence, T.1    Schreiber, U.2    Grupp, T.3
  • 7
    • 43149083031 scopus 로고    scopus 로고
    • In vitro analysis of anterior and posterior fixation in an experimental unstable burst fracture model
    • P.M. Kallemeier, B.P. Beaubien, and G.R. Buttermann In vitro analysis of anterior and posterior fixation in an experimental unstable burst fracture model J Spinal Disord Tech 21 2008 216 224
    • (2008) J Spinal Disord Tech , vol.21 , pp. 216-224
    • Kallemeier, P.M.1    Beaubien, B.P.2    Buttermann, G.R.3
  • 8
    • 18144432346 scopus 로고    scopus 로고
    • Surgical treatment of injuries of the thoracolumbar transition. 2: Operation and roentgenologic findings
    • C. Knop, M. Blauth, and V. Buhren [Surgical treatment of injuries of the thoracolumbar transition. 2: operation and roentgenologic findings] Unfallchirurg 103 2000 1032 1047
    • (2000) Unfallchirurg , vol.103 , pp. 1032-1047
    • Knop, C.1    Blauth, M.2    Buhren, V.3
  • 9
    • 0036082715 scopus 로고    scopus 로고
    • Complications in surgical treatment of thoracolumbar injuries
    • C. Knop, L. Bastian, and U. Lange Complications in surgical treatment of thoracolumbar injuries Eur Spine J 11 2002 214 226
    • (2002) Eur Spine J , vol.11 , pp. 214-226
    • Knop, C.1    Bastian, L.2    Lange, U.3
  • 10
    • 1842459414 scopus 로고    scopus 로고
    • Surgical treatment of traumatic fractures of the thoracic and lumbar spine
    • J.J. Verlaan, C.H. Diekerhof, and E. Buskens Surgical treatment of traumatic fractures of the thoracic and lumbar spine Spine 29 2004 803 814
    • (2004) Spine , vol.29 , pp. 803-814
    • Verlaan, J.J.1    Diekerhof, C.H.2    Buskens, E.3
  • 11
    • 67651151248 scopus 로고    scopus 로고
    • Anterior-only stabilization using plating with bone structural autograft versus titanium mesh cages for two- or three-column thoracolumbar burst fractures: A prospective randomized study
    • L.Y. Dai, L.S. Jiang, and S.D. Jiang Anterior-only stabilization using plating with bone structural autograft versus titanium mesh cages for two- or three-column thoracolumbar burst fractures: a prospective randomized study Spine 34 2009 1429 1435
    • (2009) Spine , vol.34 , pp. 1429-1435
    • Dai, L.Y.1    Jiang, L.S.2    Jiang, S.D.3
  • 12
    • 0037995747 scopus 로고    scopus 로고
    • Operative compared with nonoperative treatment of a thoracolumbar burst fracture without neurological deficit. A prospective, randomized study
    • K. Wood, G. Buttermann, and A. Mehbod Operative compared with nonoperative treatment of a thoracolumbar burst fracture without neurological deficit. A prospective, randomized study J Bone Joint Surg Am 85 2003 773 781
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 773-781
    • Wood, K.1    Buttermann, G.2    Mehbod, A.3
  • 13
    • 1842737258 scopus 로고    scopus 로고
    • Clinical outcome and radiographic results after surgical treatment of post-traumatic thoracolumbar kyphosis following simple type A fractures
    • H.D. Been, R.W. Poolman, and L.H. Ubags Clinical outcome and radiographic results after surgical treatment of post-traumatic thoracolumbar kyphosis following simple type A fractures Eur Spine J 13 2004 101 107
    • (2004) Eur Spine J , vol.13 , pp. 101-107
    • Been, H.D.1    Poolman, R.W.2    Ubags, L.H.3
  • 14
    • 0037626140 scopus 로고    scopus 로고
    • Effectiveness of titanium mesh cylindrical cages in anterior column reconstruction after thoracic and lumbar vertebral body resection
    • M.F. Dvorak, B.K. Kwon, and C.G. Fisher Effectiveness of titanium mesh cylindrical cages in anterior column reconstruction after thoracic and lumbar vertebral body resection Spine 28 2003 902 908
    • (2003) Spine , vol.28 , pp. 902-908
    • Dvorak, M.F.1    Kwon, B.K.2    Fisher, C.G.3
  • 15
    • 33847152168 scopus 로고    scopus 로고
    • Anterior vertebral body replacement with a titanium implant of adjustable height: A prospective clinical study
    • U. Lange, S. Edeling, and C. Knop Anterior vertebral body replacement with a titanium implant of adjustable height: a prospective clinical study Eur Spine J 16 2007 161 172
    • (2007) Eur Spine J , vol.16 , pp. 161-172
    • Lange, U.1    Edeling, S.2    Knop, C.3
  • 16
    • 33746508580 scopus 로고    scopus 로고
    • Unstable thoracolumbar burst fractures: Anterior-only versus short-segment posterior fixation
    • R.C. Sasso, K. Renkens, and D. Hanson Unstable thoracolumbar burst fractures: anterior-only versus short-segment posterior fixation J Spinal Disord Tech 19 2006 242 248
    • (2006) J Spinal Disord Tech , vol.19 , pp. 242-248
    • Sasso, R.C.1    Renkens, K.2    Hanson, D.3
  • 17
    • 36148979029 scopus 로고    scopus 로고
    • Pain regulation and health-related quality of life after thoracolumbar fractures of the spine
    • D. Briem, A. Behechtnejad, and A. Ouchmaev Pain regulation and health-related quality of life after thoracolumbar fractures of the spine Eur Spine J 16 2007 1925 1933
    • (2007) Eur Spine J , vol.16 , pp. 1925-1933
    • Briem, D.1    Behechtnejad, A.2    Ouchmaev, A.3
  • 18
    • 36148960916 scopus 로고    scopus 로고
    • Low thoracic and lumbar burst fractures: Radiographic and functional outcomes
    • H.L. Defino, and F.R. Canto Low thoracic and lumbar burst fractures: radiographic and functional outcomes Eur Spine J 16 2007 1934 1943
    • (2007) Eur Spine J , vol.16 , pp. 1934-1943
    • Defino, H.L.1    Canto, F.R.2
  • 19
    • 49249117799 scopus 로고    scopus 로고
    • A prospective cohort study comparing the VAS spine score and Roland-Morris disability questionnaire in patients with a type A traumatic thoracolumbar spinal fracture
    • J. Siebenga, V.J. Leferink, and M.J. Segers A prospective cohort study comparing the VAS spine score and Roland-Morris disability questionnaire in patients with a type A traumatic thoracolumbar spinal fracture Eur Spine J 17 2008 1096 1100
    • (2008) Eur Spine J , vol.17 , pp. 1096-1100
    • Siebenga, J.1    Leferink, V.J.2    Segers, M.J.3
  • 20
    • 65849524525 scopus 로고    scopus 로고
    • Vertebral body replacement systems with expandable cages in the treatment of various spinal pathologies: A prospectively followed case series of 60 patients
    • M.P. Arts, and W.C. Peul Vertebral body replacement systems with expandable cages in the treatment of various spinal pathologies: a prospectively followed case series of 60 patients Neurosurgery 63 2008 537 544
    • (2008) Neurosurgery , vol.63 , pp. 537-544
    • Arts, M.P.1    Peul, W.C.2
  • 21
    • 46749103284 scopus 로고    scopus 로고
    • Angular stable anterior plating following thoracolumbar corpectomy reveals superior segmental stability compared to conventional polyaxial plate fixation
    • A.C. Disch, C. Knop, and K.D. Schaser Angular stable anterior plating following thoracolumbar corpectomy reveals superior segmental stability compared to conventional polyaxial plate fixation Spine 33 2008 1429 1437
    • (2008) Spine , vol.33 , pp. 1429-1437
    • Disch, A.C.1    Knop, C.2    Schaser, K.D.3
  • 23
    • 3342908103 scopus 로고    scopus 로고
    • Preliminary results of staged anterior debridement and reconstruction using titanium mesh cages in the treatment of thoracolumbar vertebral osteomyelitis
    • A.H. Fayazi, S.C. Ludwig, and M. Dabbah Preliminary results of staged anterior debridement and reconstruction using titanium mesh cages in the treatment of thoracolumbar vertebral osteomyelitis Spine J 4 2004 388 395
    • (2004) Spine J , vol.4 , pp. 388-395
    • Fayazi, A.H.1    Ludwig, S.C.2    Dabbah, M.3
  • 24
    • 68349116155 scopus 로고    scopus 로고
    • The implications of stress patterns in the vertebral body under axial support of an artificial implant
    • V. Palissery, R.C. Mulholland, and D.S. McNally The implications of stress patterns in the vertebral body under axial support of an artificial implant Med Eng Phys 31 2009 833 837
    • (2009) Med Eng Phys , vol.31 , pp. 833-837
    • Palissery, V.1    Mulholland, R.C.2    McNally, D.S.3
  • 25
    • 0041736360 scopus 로고    scopus 로고
    • Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: Finite element analysis
    • A. Polikeit, S.J. Ferguson, and L.P. Nolte Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis Eur Spine J 12 2003 413 420
    • (2003) Eur Spine J , vol.12 , pp. 413-420
    • Polikeit, A.1    Ferguson, S.J.2    Nolte, L.P.3
  • 26
    • 13444263397 scopus 로고    scopus 로고
    • Evaluation of effects of selected factors on inter-vertebral fusion-a simulation study
    • X. Wang, and G.A. Dumas Evaluation of effects of selected factors on inter-vertebral fusion-a simulation study Med Eng Phys 27 2005 197 207
    • (2005) Med Eng Phys , vol.27 , pp. 197-207
    • Wang, X.1    Dumas, G.A.2
  • 27
    • 23244447401 scopus 로고    scopus 로고
    • Analysis of stress distribution in lumbar interbody fusion
    • N. Kumar, M.R. Judith, and A. Kumar Analysis of stress distribution in lumbar interbody fusion Spine (Phila Pa 1976) 30 2005 1731 1735
    • (2005) Spine (Phila Pa 1976) , vol.30 , pp. 1731-1735
    • Kumar, N.1    Judith, M.R.2    Kumar, A.3
  • 28
    • 14844363695 scopus 로고    scopus 로고
    • A biomechanical study of regional endplate strength and cage morphology as it relates to structural interbody support
    • T.G. Lowe, S. Hashim, and L.A. Wilson A biomechanical study of regional endplate strength and cage morphology as it relates to structural interbody support Spine (Phila Pa 1976) 29 2004 2389 2394
    • (2004) Spine (Phila Pa 1976) , vol.29 , pp. 2389-2394
    • Lowe, T.G.1    Hashim, S.2    Wilson, L.A.3
  • 29
    • 0742304553 scopus 로고    scopus 로고
    • Biomechanical evaluation of contemporary posterior spinal internal fixation configurations in an unstable burst-fracture calf spine model: Special references of hook configurations and pedicle screws
    • H.S. An, K. Singh, and A.R. Vaccaro Biomechanical evaluation of contemporary posterior spinal internal fixation configurations in an unstable burst-fracture calf spine model: special references of hook configurations and pedicle screws Spine 29 2004 257 262
    • (2004) Spine , vol.29 , pp. 257-262
    • An, H.S.1    Singh, K.2    Vaccaro, A.R.3
  • 30
    • 3042542717 scopus 로고    scopus 로고
    • Biomechanical testing of anterior and posterior thoracolumbar instrumentation in the cadaveric spine. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004
    • K.M. Eichholz, P.W. Hitchon, and A. From Biomechanical testing of anterior and posterior thoracolumbar instrumentation in the cadaveric spine. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004 J Neurosurg Spine 1 2004 116 121
    • (2004) J Neurosurg Spine , vol.1 , pp. 116-121
    • Eichholz, K.M.1    Hitchon, P.W.2    From, A.3
  • 31
    • 0033082893 scopus 로고    scopus 로고
    • Biomechanical studies on two anterior thoracolumbar implants in cadaveric spines
    • P.W. Hitchon, V.K. Goel, and T. Rogge Biomechanical studies on two anterior thoracolumbar implants in cadaveric spines Spine 24 1999 213 218
    • (1999) Spine , vol.24 , pp. 213-218
    • Hitchon, P.W.1    Goel, V.K.2    Rogge, T.3
  • 32
    • 0031053102 scopus 로고    scopus 로고
    • Biomechanical evaluation of anterior and posterior fixations in an unstable calf spine model
    • T.H. Lim, H.S. An, and J.H. Hong Biomechanical evaluation of anterior and posterior fixations in an unstable calf spine model Spine 22 1997 261 266
    • (1997) Spine , vol.22 , pp. 261-266
    • Lim, T.H.1    An, H.S.2    Hong, J.H.3
  • 34
    • 0027944542 scopus 로고
    • Experimental study of thoracolumbar burst fractures. A radiographic and biomechanical analysis of anterior and posterior instrumentation systems
    • Y. Shono, P.C. McAfee, and B.W. Cunningham Experimental study of thoracolumbar burst fractures. A radiographic and biomechanical analysis of anterior and posterior instrumentation systems Spine 19 1994 1711 1722
    • (1994) Spine , vol.19 , pp. 1711-1722
    • Shono, Y.1    McAfee, P.C.2    Cunningham, B.W.3
  • 35
    • 43549123081 scopus 로고    scopus 로고
    • Loads on a telemeterized vertebral body replacement measured in two patients
    • A. Rohlmann, F. Graichen, and R. Kayser Loads on a telemeterized vertebral body replacement measured in two patients Spine 33 2008 1170 1179
    • (2008) Spine , vol.33 , pp. 1170-1179
    • Rohlmann, A.1    Graichen, F.2    Kayser, R.3
  • 36
    • 23944523816 scopus 로고    scopus 로고
    • In vitro, biomechanical comparison of an anterior lumbar interbody fusion with an anteriorly placed, low-profile lumbar plate and posteriorly placed pedicle screws or translaminar screws
    • B.P. Beaubien, A. Derincek, and W.D. Lew In vitro, biomechanical comparison of an anterior lumbar interbody fusion with an anteriorly placed, low-profile lumbar plate and posteriorly placed pedicle screws or translaminar screws Spine 30 2005 1846 1851
    • (2005) Spine , vol.30 , pp. 1846-1851
    • Beaubien, B.P.1    Derincek, A.2    Lew, W.D.3
  • 37
    • 0028353925 scopus 로고
    • Thoracolumbar burst fracture. A biomechanical investigation of its multidirectional flexibility
    • M.M. Panjabi, T.R. Oxland, and R.M. Lin Thoracolumbar burst fracture. A biomechanical investigation of its multidirectional flexibility Spine 19 1994 578 585
    • (1994) Spine , vol.19 , pp. 578-585
    • Panjabi, M.M.1    Oxland, T.R.2    Lin, R.M.3
  • 38
    • 33644630301 scopus 로고    scopus 로고
    • The incidence and distribution of burst fractures
    • F.V. Bensch, M.P. Koivikko, and M.J. Kiuru The incidence and distribution of burst fractures Emerg Radiol 12 2006 124 129
    • (2006) Emerg Radiol , vol.12 , pp. 124-129
    • Bensch, F.V.1    Koivikko, M.P.2    Kiuru, M.J.3
  • 39
    • 0031696694 scopus 로고    scopus 로고
    • Changes in the disc space after fractures of the thoracolumbar spine
    • F.C. Oner, R.R. van der Rijt, and L.M. Ramos Changes in the disc space after fractures of the thoracolumbar spine J Bone Joint Surg Br 80 1998 833 839
    • (1998) J Bone Joint Surg Br , vol.80 , pp. 833-839
    • Oner, F.C.1    Van Der Rijt, R.R.2    Ramos, L.M.3
  • 40
    • 33646771005 scopus 로고    scopus 로고
    • Reliability of a novel classification system for thoracolumbar injuries: The Thoracolumbar Injury Severity Score
    • A.R. Vaccaro, E.M. Baron, and J. Sanfilippo Reliability of a novel classification system for thoracolumbar injuries: the Thoracolumbar Injury Severity Score Spine 31 11 Suppl 2006 S62 S69
    • (2006) Spine , vol.31 , Issue.11 SUPPL.
    • Vaccaro, A.R.1    Baron, E.M.2    Sanfilippo, J.3
  • 42
    • 2342443797 scopus 로고    scopus 로고
    • Stiffness of prosthetic nucleus determines stiffness of reconstructed lumbar calf disc
    • G.R. Buttermann, and B.P. Beaubien Stiffness of prosthetic nucleus determines stiffness of reconstructed lumbar calf disc Spine J 4 2004 265 274
    • (2004) Spine J , vol.4 , pp. 265-274
    • Buttermann, G.R.1    Beaubien, B.P.2
  • 43
    • 33745158367 scopus 로고    scopus 로고
    • Comparative biomechanical testing of anterior and posterior stabilization procedures
    • C.H. Flamme, C. Hurschler, and C. Heymann Comparative biomechanical testing of anterior and posterior stabilization procedures Spine 30 2005 E352 E362
    • (2005) Spine , vol.30
    • Flamme, C.H.1    Hurschler, C.2    Heymann, C.3
  • 44
    • 76449104038 scopus 로고    scopus 로고
    • Biomechanical evaluation of short-segment posterior instrumentation with and without crosslinks in a human cadaveric unstable thoracolumbar burst fracture model
    • G.M. Wahba, N. Bhatia, and C.N. Bui Biomechanical evaluation of short-segment posterior instrumentation with and without crosslinks in a human cadaveric unstable thoracolumbar burst fracture model Spine (Phila Pa 1976) 35 2010 278 285
    • (2010) Spine (Phila Pa 1976) , vol.35 , pp. 278-285
    • Wahba, G.M.1    Bhatia, N.2    Bui, C.N.3
  • 45
    • 0034650806 scopus 로고    scopus 로고
    • Load-sharing characteristics of stabilized lumbar spine segments
    • P.A. Cripton, G.M. Jain, and R.H. Wittenberg Load-sharing characteristics of stabilized lumbar spine segments Spine 25 2000 170 179
    • (2000) Spine , vol.25 , pp. 170-179
    • Cripton, P.A.1    Jain, G.M.2    Wittenberg, R.H.3
  • 46
    • 0031924426 scopus 로고    scopus 로고
    • Testing criteria for spinal implants: Recommendations for the standardization of in vitro stability testing of spinal implants
    • H.J. Wilke, K. Wenger, and L. Claes Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants Eur Spine J 7 1998 148 154
    • (1998) Eur Spine J , vol.7 , pp. 148-154
    • Wilke, H.J.1    Wenger, K.2    Claes, L.3
  • 47
    • 0034533688 scopus 로고    scopus 로고
    • Three-dimensional motion analysis with Synex. Comparative biomechanical test series with a new vertebral body replacement for the thoracolumbar spine
    • C. Knop, U. Lange, and L. Bastian Three-dimensional motion analysis with Synex. Comparative biomechanical test series with a new vertebral body replacement for the thoracolumbar spine Eur Spine J 9 2000 472 485
    • (2000) Eur Spine J , vol.9 , pp. 472-485
    • Knop, C.1    Lange, U.2    Bastian, L.3
  • 48
    • 0029035767 scopus 로고
    • Instability of the lumbar burst fracture and limitations of transpedicular instrumentation
    • P.J. Slosar Jr., A.G. Patwardhan, and M. Lorenz Instability of the lumbar burst fracture and limitations of transpedicular instrumentation Spine 20 1995 1452 1461
    • (1995) Spine , vol.20 , pp. 1452-1461
    • Slosar, Jr.P.J.1    Patwardhan, A.G.2    Lorenz, M.3
  • 49
    • 0031060065 scopus 로고    scopus 로고
    • Loads on an internal spinal fixation device during walking
    • A. Rohlmann, G. Bergmann, and F. Graichen Loads on an internal spinal fixation device during walking J Biomech 30 1997 41 47
    • (1997) J Biomech , vol.30 , pp. 41-47
    • Rohlmann, A.1    Bergmann, G.2    Graichen, F.3
  • 50
    • 0028533934 scopus 로고
    • A method for the fatigue testing of pedicle screw fixation devices
    • V.K. Goel, J.M. Winterbottom, and J.N. Weinstein A method for the fatigue testing of pedicle screw fixation devices J Biomech 27 1994 1383 1388
    • (1994) J Biomech , vol.27 , pp. 1383-1388
    • Goel, V.K.1    Winterbottom, J.M.2    Weinstein, J.N.3
  • 51
    • 33750494778 scopus 로고    scopus 로고
    • Two in vivo surgical approaches for lumbar corpectomy using allograft and a metallic implant: A controlled clinical and biomechanical study
    • P. Huang, M.C. Gupta, and N. Sarigul-Klijn Two in vivo surgical approaches for lumbar corpectomy using allograft and a metallic implant: a controlled clinical and biomechanical study Spine J 6 2006 648 658
    • (2006) Spine J , vol.6 , pp. 648-658
    • Huang, P.1    Gupta, M.C.2    Sarigul-Klijn, N.3
  • 52
    • 0031925505 scopus 로고    scopus 로고
    • Spinal segment range of motion as a function of in vitro test conditions: Effects of exposure period, accumulated cycles, angular-deformation rate, and moisture condition
    • H.J. Wilke, B. Jungkunz, and K. Wenger Spinal segment range of motion as a function of in vitro test conditions: effects of exposure period, accumulated cycles, angular-deformation rate, and moisture condition Anat Rec 251 1998 15 19
    • (1998) Anat Rec , vol.251 , pp. 15-19
    • Wilke, H.J.1    Jungkunz, B.2    Wenger, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.