-
1
-
-
33646793785
-
Surgical decision making for unstable thoracolumbar spine injuries: Results of a consensus panel review by the Spine Trauma Study Group
-
Vaccaro AR, Lim MR, Hurlbert RJ, et al. Surgical decision making for unstable thoracolumbar spine injuries: results of a consensus panel review by the Spine Trauma Study Group. J Spinal Disord Tech. 2006;19:1-10.
-
(2006)
J Spinal Disord Tech
, vol.19
, pp. 1-10
-
-
Vaccaro, A.R.1
Lim, M.R.2
Hurlbert, R.J.3
-
2
-
-
0027967998
-
Biomechanical evaluation of the stability of thoracolumbar burst fractures
-
James KS, Wenger KH, Schlegel JD, et al. Biomechanical evaluation of the stability of thoracolumbar burst fractures. Spine. 1994;19:1731-1740.
-
(1994)
Spine
, vol.19
, pp. 1731-1740
-
-
James, K.S.1
Wenger, K.H.2
Schlegel, J.D.3
-
3
-
-
0034276991
-
Short segment posterior instrumentation, reduction and fusion of unstable thoracolumbar burst fractures: A review of 26 cases
-
Razak M, Mahmud MM, Hyzan MY, et al. Short segment posterior instrumentation, reduction and fusion of unstable thoracolumbar burst fractures: a review of 26 cases. Med J Malaysia. 2000;55 (suppl C):9-13.
-
(2000)
Med J Malaysia
, vol.55
, Issue.SUPPL. C
, pp. 9-13
-
-
Razak, M.1
Mahmud, M.M.2
Hyzan, M.Y.3
-
4
-
-
0027453060
-
Spinal mobility and deformity after Harrington rod stabilization and limited arthrodesis of thoracolumbar fractures
-
Dekutoski MB, Conlan ES, Salciccioli GG. Spinal mobility and deformity after Harrington rod stabilization and limited arthrodesis of thoracolumbar fractures. J Bone Joint Surg Am. 1993;75:168-176.
-
(1993)
J Bone Joint Surg Am
, vol.75
, pp. 168-176
-
-
Dekutoski, M.B.1
Conlan, E.S.2
Salciccioli, G.G.3
-
5
-
-
21344444781
-
Anterior versus posterior treatment of stable thoracolumbar burst fractures without neurologic deficit: A prospective, randomized study
-
Wood KB, Bohn D, Mehbod A. Anterior versus posterior treatment of stable thoracolumbar burst fractures without neurologic deficit: a prospective, randomized study. J Spinal Disord Tech. 2005; 18(suppl):S15-S23.
-
(2005)
J Spinal Disord Tech
, vol.18
, Issue.SUPPL.
-
-
Wood, K.B.1
Bohn, D.2
Mehbod, A.3
-
6
-
-
0026019235
-
Anterior plating in thoracolumbar spine injuries. Indication, technique, and results
-
Haas N, Blauth M, Tscherne H. Anterior plating in thoracolumbar spine injuries. Indication, technique, and results. Spine. 1991;16:S100-S111.
-
(1991)
Spine
, vol.16
-
-
Haas, N.1
Blauth, M.2
Tscherne, H.3
-
7
-
-
0029133645
-
Long-term follow-up results of thoracolumbar fractures after posterior instrumentation
-
Tasdemiroglu E, Tibbs PA. Long-term follow-up results of thoracolumbar fractures after posterior instrumentation. Spine. 1995;20:1704-1708.
-
(1995)
Spine
, vol.20
, pp. 1704-1708
-
-
Tasdemiroglu, E.1
Tibbs, P.A.2
-
8
-
-
21344447018
-
Anterior-only stabilization of three-column thoracolumbar injuries
-
Sasso RC, Best NM, Reilly TM, et al. Anterior-only stabilization of three-column thoracolumbar injuries. J Spinal Disord Tech. 2005; 18(suppl):S7-S14.
-
(2005)
J Spinal Disord Tech
, vol.18
, Issue.SUPPL.
-
-
Sasso, R.C.1
Best, N.M.2
Reilly, T.M.3
-
9
-
-
0026657201
-
Pedicle screw instrumentation for thoracolumbar burst fractures and fracture-dislocations
-
Carl AL, Tromanhauser SG, Roger DJ. Pedicle screw instrumentation for thoracolumbar burst fractures and fracture-dislocations. Spine. 1992;17:S317-S324.
-
(1992)
Spine
, vol.17
-
-
Carl, A.L.1
Tromanhauser, S.G.2
Roger, D.J.3
-
10
-
-
0035114748
-
Anterior decompression and fixation versus posterior reposition and semirigid fixation in the treatment of unstable burst thoracolumbar fracture: Prospective clinical trial
-
Stancic MF, Gregorovic E, Nozica E, et al. Anterior decompression and fixation versus posterior reposition and semirigid fixation in the treatment of unstable burst thoracolumbar fracture: prospective clinical trial. Croat Med J. 2001;42:49-53.
-
(2001)
Croat Med J
, vol.42
, pp. 49-53
-
-
Stancic, M.F.1
Gregorovic, E.2
Nozica, E.3
-
11
-
-
0027509721
-
Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report
-
McLain RF, Sparling E, Benson DR. Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report. J Bone Joint Surg Am. 1993;75:162-167.
-
(1993)
J Bone Joint Surg Am
, vol.75
, pp. 162-167
-
-
McLain, R.F.1
Sparling, E.2
Benson, D.R.3
-
12
-
-
0035161709
-
Late results of thoracolumbar fractures after posterior instrumentation and transpedicular bone grafting
-
Knop C, Fabian HF, Bastian L, et al. Late results of thoracolumbar fractures after posterior instrumentation and transpedicular bone grafting. Spine. 2001;26:88-99.
-
(2001)
Spine
, vol.26
, pp. 88-99
-
-
Knop, C.1
Fabian, H.F.2
Bastian, L.3
-
13
-
-
0029039843
-
Anterior stabilization of thoracolumbar burst fractures using the Kaneda device: A preliminary report
-
Kirkpatrick JS, Wilber RG, Likavec M, et al. Anterior stabilization of thoracolumbar burst fractures using the Kaneda device: a preliminary report. Orthopedics. 1995;18:673-678.
-
(1995)
Orthopedics
, vol.18
, pp. 673-678
-
-
Kirkpatrick, J.S.1
Wilber, R.G.2
Likavec, M.3
-
14
-
-
0027253913
-
Biomechanical analysis of three surgical approaches for lumbar burst fractures using short-segment instrumentation
-
Gurwitz GS, Dawson JM, McNamara MJ, et al. Biomechanical analysis of three surgical approaches for lumbar burst fractures using short-segment instrumentation. Spine. 1993;18:977-982.
-
(1993)
Spine
, vol.18
, pp. 977-982
-
-
Gurwitz, G.S.1
Dawson, J.M.2
McNamara, M.J.3
-
15
-
-
33745158367
-
Comparative biomechanical testing of anterior and posterior stabilization procedures
-
Flamme CH, Hurschler C, Heymann C, et al. Comparative biomechanical testing of anterior and posterior stabilization procedures. Spine. 2005;30:E352-E362.
-
(2005)
Spine
, vol.30
-
-
Flamme, C.H.1
Hurschler, C.2
Heymann, C.3
-
16
-
-
0742304553
-
Biomechanical evaluation of contemporary posterior spinal internal fixation configurations in an unstable burst-fracture calf spine model: Special references of hook configurations and pedicle screws
-
An HS, Singh K, Vaccaro AR, et al. Biomechanical evaluation of contemporary posterior spinal internal fixation configurations in an unstable burst-fracture calf spine model: special references of hook configurations and pedicle screws. Spine. 2004;29:257-262.
-
(2004)
Spine
, vol.29
, pp. 257-262
-
-
An, H.S.1
Singh, K.2
Vaccaro, A.R.3
-
17
-
-
3042542717
-
Biomechanical testing of anterior and posterior thoracolumbar instrumentation in the cadaveric spine. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004
-
Eichholz KM, Hitchon PW, From A, et al. Biomechanical testing of anterior and posterior thoracolumbar instrumentation in the cadaveric spine. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004. J Neurosurg Spine. 2004;1:116-121.
-
(2004)
J Neurosurg Spine
, vol.1
, pp. 116-121
-
-
Eichholz, K.M.1
Hitchon, P.W.2
From, A.3
-
18
-
-
0027944542
-
Experimental study of thoracolumbar burst fractures. A radiographic and biomechanical analysis of anterior and posterior instrumentation systems
-
Shono Y, McAfee PC, Cunningham BW. Experimental study of thoracolumbar burst fractures. A radiographic and biomechanical analysis of anterior and posterior instrumentation systems. Spine. 1994;19:1711-1722.
-
(1994)
Spine
, vol.19
, pp. 1711-1722
-
-
Shono, Y.1
McAfee, P.C.2
Cunningham, B.W.3
-
19
-
-
0025100578
-
A biomechanical investigation of short segment spinal fixation for burst fractures with varying degrees of posterior disruption
-
Mann KA, McGowan DP, Fredrickson BE, et al. A biomechanical investigation of short segment spinal fixation for burst fractures with varying degrees of posterior disruption. Spine. 1990;15:470-478.
-
(1990)
Spine
, vol.15
, pp. 470-478
-
-
Mann, K.A.1
McGowan, D.P.2
Fredrickson, B.E.3
-
20
-
-
0029022463
-
Validity of the three-column theory of thoracolumbar fractures. A biomechanic investigation
-
Panjabi MM, Oxland TR, Kifune M, et al. Validity of the three-column theory of thoracolumbar fractures. A biomechanic investigation. Spine. 1995;20:1122-1127.
-
(1995)
Spine
, vol.20
, pp. 1122-1127
-
-
Panjabi, M.M.1
Oxland, T.R.2
Kifune, M.3
-
21
-
-
0028353925
-
Thoracolumbar burst fracture. A biomechanical investigation of its multidirectional flexibility
-
Panjabi MM, Oxland TR, Lin RM, et al. Thoracolumbar burst fracture. A biomechanical investigation of its multidirectional flexibility. Spine. 1994;19:578-585.
-
(1994)
Spine
, vol.19
, pp. 578-585
-
-
Panjabi, M.M.1
Oxland, T.R.2
Lin, R.M.3
-
22
-
-
0027934923
-
A comprehensive classification of thoracic and lumbar injuries
-
Magerl F, Aebi M, Gertzbein SD, et al. A comprehensive classification of thoracic and lumbar injuries. Eur Spine J. 1994;3:184-201.
-
(1994)
Eur Spine J
, vol.3
, pp. 184-201
-
-
Magerl, F.1
Aebi, M.2
Gertzbein, S.D.3
-
23
-
-
23944523816
-
In vitro, biomechanical comparison of an anterior lumbar interbody fusion with an anteriorly placed, low-profile lumbar plate and posteriorly placed pedicle screws or translaminar screws
-
Beaubien BP, Derincek A, Lew WD, et al. In vitro, biomechanical comparison of an anterior lumbar interbody fusion with an anteriorly placed, low-profile lumbar plate and posteriorly placed pedicle screws or translaminar screws. Spine. 2005;30:1846-1851.
-
(2005)
Spine
, vol.30
, pp. 1846-1851
-
-
Beaubien, B.P.1
Derincek, A.2
Lew, W.D.3
-
24
-
-
0031924426
-
Testing criteria for spinal implants: Recommendations for the standardization of in vitro stability testing of spinal implants
-
Wilke HJ, Wenger K, Claes L. Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J. 1998;7:148-154.
-
(1998)
Eur Spine J
, vol.7
, pp. 148-154
-
-
Wilke, H.J.1
Wenger, K.2
Claes, L.3
-
25
-
-
0033820917
-
In vitro axial preload application during spine flexibility testing: Towards reduced apparatus-related artefacts
-
Cripton PA, Bruehlmann SB, Orr TE, et al. In vitro axial preload application during spine flexibility testing: towards reduced apparatus-related artefacts. J Biomech. 2000;33:1559-1568.
-
(2000)
J Biomech
, vol.33
, pp. 1559-1568
-
-
Cripton, P.A.1
Bruehlmann, S.B.2
Orr, T.E.3
-
26
-
-
0027939403
-
The load sharing classification of spine fractures
-
McCormack T, Karaikovic E, Gaines RW. The load sharing classification of spine fractures. Spine. 1994;19:1741-1744.
-
(1994)
Spine
, vol.19
, pp. 1741-1744
-
-
McCormack, T.1
Karaikovic, E.2
Gaines, R.W.3
-
27
-
-
33644841640
-
Influence of screw positioning in a new anterior spine fixator on implant loosening in osteoporotic vertebrae
-
Reinhold M, Schwieger K, Goldhahn J, et al. Influence of screw positioning in a new anterior spine fixator on implant loosening in osteoporotic vertebrae. Spine. 2006;31:406-413.
-
(2006)
Spine
, vol.31
, pp. 406-413
-
-
Reinhold, M.1
Schwieger, K.2
Goldhahn, J.3
-
28
-
-
0142059603
-
Can novel clinical densitometric techniques replace or improve DXA in predicting bone strength in osteoporosis at the hip and other skeletal sites?
-
Lochmuller EM, Muller R, Kuhn V, et al. Can novel clinical densitometric techniques replace or improve DXA in predicting bone strength in osteoporosis at the hip and other skeletal sites? J Bone Miner Res. 2003;18:906-912.
-
(2003)
J Bone Miner Res
, vol.18
, pp. 906-912
-
-
Lochmuller, E.M.1
Muller, R.2
Kuhn, V.3
-
29
-
-
0036311834
-
Quantitative computed tomography estimates of the mechanical properties of human vertebral trabecular bone
-
Kopperdahl DL, Morgan EF, Keaveny TM. Quantitative computed tomography estimates of the mechanical properties of human vertebral trabecular bone. J Orthop Res. 2002;20:801-805.
-
(2002)
J Orthop Res
, vol.20
, pp. 801-805
-
-
Kopperdahl, D.L.1
Morgan, E.F.2
Keaveny, T.M.3
-
30
-
-
0024150832
-
A comparative biomechanical study of spinal fixation using the combination spinal rod-plate and transpedicular screw fixation system
-
ChangKW, Dewei ZF, McAfee PC, et al. A comparative biomechanical study of spinal fixation using the combination spinal rod-plate and transpedicular screw fixation system. J Spinal Disord. 1988;1:257-266.
-
(1988)
J Spinal Disord
, vol.1
, pp. 257-266
-
-
Chang, K.W.1
Dewei, Z.F.2
McAfee, P.C.3
-
31
-
-
0034533688
-
Three-dimensional motion analysis with Synex. Comparative biomechanical test series with a new vertebral body replacement for the thoracolumbar spine
-
Knop CF, Lange UF, Bastian LF, et al. Three-dimensional motion analysis with Synex. Comparative biomechanical test series with a new vertebral body replacement for the thoracolumbar spine. Eur Spine J. 2000;9:472-485.
-
(2000)
Eur Spine J
, vol.9
, pp. 472-485
-
-
Knop, C.F.1
Lange, U.F.2
Bastian, L.F.3
-
32
-
-
1842787748
-
Thoracolumbar fracture stabilization: Comparative biomechanical evaluation of a new video-assisted implantable system
-
Schultheiss M, Hartwig E, Kinzl L, et al. Thoracolumbar fracture stabilization: comparative biomechanical evaluation of a new video-assisted implantable system. Eur Spine J. 2004;13:93-100.
-
(2004)
Eur Spine J
, vol.13
, pp. 93-100
-
-
Schultheiss, M.1
Hartwig, E.2
Kinzl, L.3
-
33
-
-
0023749115
-
Biomechanical analysis of anterior and posterior instrumentation systems after corpectomy. A calf-spine model
-
Gurr KR, McAfee PC, Shih CM, Biomechanical analysis of anterior and posterior instrumentation systems after corpectomy. A calf-spine model. J Bone Joint Surg Am. 1988;70:1182-1191.
-
(1988)
J Bone Joint Surg Am
, vol.70
, pp. 1182-1191
-
-
Gurr, K.R.1
McAfee, P.C.2
Shih, C.M.3
-
34
-
-
0033082893
-
Biomechanical studies on two anterior thoracolumbar implants in cadaveric spines
-
Hitchon PW, Goel VK, Rogge T, et al. Biomechanical studies on two anterior thoracolumbar implants in cadaveric spines. Spine. 1999;24:213-218.
-
(1999)
Spine
, vol.24
, pp. 213-218
-
-
Hitchon, P.W.1
Goel, V.K.2
Rogge, T.3
-
35
-
-
0030948309
-
Anterior instrumentation of the thoracolumbar spine. A biomechanical comparison
-
Dick JC, Brodke DS, Zdeblick TA, et al. Anterior instrumentation of the thoracolumbar spine. A biomechanical comparison. Spine. 1997;22:744-750.
-
(1997)
Spine
, vol.22
, pp. 744-750
-
-
Dick, J.C.1
Brodke, D.S.2
Zdeblick, T.A.3
-
36
-
-
0029035767
-
Instability of the lumbar burst fracture and limitations of transpedicular instrumentation
-
Slosar PJ Jr, Patwardhan AG, Lorenz M, et al. Instability of the lumbar burst fracture and limitations of transpedicular instrumentation. Spine. 1995;20:1452-1461.
-
(1995)
Spine
, vol.20
, pp. 1452-1461
-
-
Slosar Jr, P.J.1
Patwardhan, A.G.2
Lorenz, M.3
-
37
-
-
0031024523
-
Anterior decompression and stabilization with the Kaneda device for thoracolumbar burst fractures associated with neurological deficits
-
Kaneda K, Taneichi H, Abumi K, et al. Anterior decompression and stabilization with the Kaneda device for thoracolumbar burst fractures associated with neurological deficits. J Bone Joint Surg Am. 1997;79:69-83.
-
(1997)
J Bone Joint Surg Am
, vol.79
, pp. 69-83
-
-
Kaneda, K.1
Taneichi, H.2
Abumi, K.3
|