메뉴 건너뛰기




Volumn 16, Issue 6, 2007, Pages 813-820

Two column lesions in the thoracolumbar junction: Anterior, posterior or combined approach? A comparative biomechanical in vitro investigation

Author keywords

Angle stable plate system; Biomechanics; Fixateur interne; In vitro testing; Spine

Indexed keywords

ANATOMY; ARTICLE; BIOMECHANICS; BONE GRAFT; BONE PLATE; BONE SCREW; CONTROLLED STUDY; FRACTURE; HUMAN; HUMAN TISSUE; ILIAC CREST; IN VITRO STUDY; MEDICAL INSTRUMENTATION; MOTION ANALYSIS SYSTEM; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RANGE OF MOTION; RIGIDITY; SIMULATION; SPINAL CORD LESION; SPINE STABILIZATION; STATISTICAL ANALYSIS; SURGICAL APPROACH; THORACOLUMBAR SPINE; THREE DIMENSIONAL IMAGING; TORSION;

EID: 34250614763     PISSN: 09406719     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00586-006-0201-1     Document Type: Article
Times cited : (33)

References (37)
  • 1
    • 0029131590 scopus 로고
    • Biomechanical evaluation of anterior thoracolumbar spinal instrumentation
    • An HS, Lim TH, You JW, Hong JH, Eck J, McGrady L (1995) Biomechanical evaluation of anterior thoracolumbar spinal instrumentation. Spine 20:1979-1983
    • (1995) Spine , vol.20 , pp. 1979-1983
    • An, H.S.1    Lim, T.H.2    You, J.W.3    Hong, J.H.4    Eck, J.5    McGrady, L.6
  • 2
    • 0032904053 scopus 로고    scopus 로고
    • Comparison of two types of surgery for thoraco-lumbar burst fractures: Combined anterior and posterior stabilisation vs. posterior instrumentation only
    • Been HD, Bouma GJ (1999) Comparison of two types of surgery for thoraco-lumbar burst fractures: combined anterior and posterior stabilisation vs. posterior instrumentation only. Acta Neurochir (Wien) 141:349-357
    • (1999) Acta Neurochir (Wien) , vol.141 , pp. 349-357
    • Been, H.D.1    Bouma, G.J.2
  • 3
    • 0035672666 scopus 로고    scopus 로고
    • Endoscopic techniques for the management of spinal trauma
    • Beisse R, Potulski M, Bühren V (2001) Endoscopic techniques for the management of spinal trauma. Eur J Trauma 27:275-291
    • (2001) Eur J Trauma , vol.27 , pp. 275-291
    • Beisse, R.1    Potulski, M.2    Bühren, V.3
  • 4
    • 0036527417 scopus 로고    scopus 로고
    • Development and clinical application of a thoracoscopically implantable anterior plate for treatment of thoracolumbar fractures and instabilities
    • Beisse R, Potulski M, Beger J, Bühren V (2002) Development and clinical application of a thoracoscopically implantable anterior plate for treatment of thoracolumbar fractures and instabilities. Orthopäde 31:413-422
    • (2002) Orthopäde , vol.31 , pp. 413-422
    • Beisse, R.1    Potulski, M.2    Beger, J.3    Bühren, V.4
  • 6
    • 1542510544 scopus 로고    scopus 로고
    • Biomechanical comparison of anterolateral plate, lateral plate and pedicle screw-rods for enhancing anterolateral lumbar interbody cage stabilization
    • Bozkus H, Chamberlain RH, Perez Garza LE, Crawford NR, Dickman CA (2004) Biomechanical comparison of anterolateral plate, lateral plate and pedicle screw-rods for enhancing anterolateral lumbar interbody cage stabilization. Spine 29:635-641
    • (2004) Spine , vol.29 , pp. 635-641
    • Bozkus, H.1    Chamberlain, R.H.2    Perez Garza, L.E.3    Crawford, N.R.4    Dickman, C.A.5
  • 7
    • 0041472693 scopus 로고    scopus 로고
    • Anterior thoracolumbar instrumentation: Stiffness and load sharing characteristics of plate and rod systems
    • Brodke DS, Gollogly S, Bachus KN, Mohr RA, Nguyen B-KN (2003) Anterior thoracolumbar instrumentation: stiffness and load sharing characteristics of plate and rod systems. Spine 28:1794-1801
    • (2003) Spine , vol.28 , pp. 1794-1801
    • Brodke, D.S.1    Gollogly, S.2    Bachus, K.N.3    Mohr, R.A.4    B-Kn, N.5
  • 8
    • 0347116277 scopus 로고    scopus 로고
    • Injuries of the thoracic and lumbar spine
    • Bühren V (2001) Injuries of the thoracic and lumbar spine. Chirurg 72:865-878
    • (2001) Chirurg , vol.72 , pp. 865-878
    • Bühren, V.1
  • 9
    • 0026688075 scopus 로고
    • Neurologic recovery associated with anterior decompression of spine fractures at the thoracolumbar junction (T12-L1)
    • Suppl 8
    • Closhy JC, Akbarnia BA, Buchholz RD, Burkus JK, Backer RJ (1992) Neurologic recovery associated with anterior decompression of spine fractures at the thoracolumbar junction (T12-L1). Spine 17(Suppl 8):325S-330S
    • (1992) Spine , vol.17
    • Closhy, J.C.1    Akbarnia, B.A.2    Buchholz, R.D.3    Burkus, J.K.4    Backer, R.J.5
  • 12
    • 0028032492 scopus 로고
    • Surgical treatment alternatives for fixation of unstable fractures of the thoracic and lumbar spine. a meta analysis
    • Suppl 20
    • Dickman CA, Yahiro MA, Lu HTC, Melkerson MN (1994) Surgical treatment alternatives for fixation of unstable fractures of the thoracic and lumbar spine. A meta analysis. Spine 19(Suppl 20):2266S-2273S
    • (1994) Spine , vol.19
    • Dickman, C.A.1    Yahiro, M.A.2    Lu, H.T.C.3    Melkerson, M.N.4
  • 13
    • 0023722036 scopus 로고
    • Biomechanical comparison of spinal fracture models and the stabilizing effects of posterior instrumentations
    • Ferguson RL, Tencer AF, Woodward P, Allen BL Jr (1988) Biomechanical comparison of spinal fracture models and the stabilizing effects of posterior instrumentations. Spine 13:453-460
    • (1988) Spine , vol.13 , pp. 453-460
    • Ferguson, R.L.1    Tencer, A.F.2    Woodward, P.3    Allen Jr., B.L.4
  • 14
    • 33745158367 scopus 로고    scopus 로고
    • Comparative biomechanical testing of anterior and posterior stabilization procedures
    • Flamme CH, Hurschler C, Heymann C, von der Heide N (2005) Comparative biomechanical testing of anterior and posterior stabilization procedures. Spine 30:E352-E362
    • (2005) Spine , vol.30
    • Flamme, C.H.1    Hurschler, C.2    Heymann, C.3    Von Der Heide, N.4
  • 15
    • 0026926184 scopus 로고
    • Volvo award in experimental studies. Vertebral burst fractures an experimental, morphologic, and radiographic study
    • Fredrickson BE, Edwards WT, Rauschning W, Bayley JC, Yuan HA (1992) Volvo award in experimental studies. Vertebral burst fractures an experimental, morphologic, and radiographic study. Spine 17:1012-1021
    • (1992) Spine , vol.17 , pp. 1012-1021
    • Fredrickson, B.E.1    Edwards, W.T.2    Rauschning, W.3    Bayley, J.C.4    Yuan, H.A.5
  • 16
    • 0031036560 scopus 로고    scopus 로고
    • Anterior instrumentation in the management of thoracolumbar burst fractures
    • Ghanayem AJ, Zdeblick TA (1997) Anterior instrumentation in the management of thoracolumbar burst fractures. Clin Orthop 335:89-100
    • (1997) Clin Orthop , vol.335 , pp. 89-100
    • Ghanayem, A.J.1    Zdeblick, T.A.2
  • 17
    • 0026019235 scopus 로고
    • Anterior plating in thoracolumbar spine injuries. Indication, technique and results
    • Suppl 3
    • Haas N, Blauth M, Tscherne H (1991) Anterior plating in thoracolumbar spine injuries. Indication, technique and results. Spine 16(Suppl 3):100S-111S
    • (1991) Spine , vol.16
    • Haas, N.1    Blauth, M.2    Tscherne, H.3
  • 18
    • 0031024523 scopus 로고    scopus 로고
    • Anterior decompression and stabilization with the Kaneda device for thoracolumbar burst fractures associated with neurological deficits
    • Kaneda K, Taneichi H, Abumi K, Hashimoto T, Satoh S, Fujiya M (1997) Anterior decompression and stabilization with the Kaneda device for thoracolumbar burst fractures associated with neurological deficits. J Bone Joint Surg [Am] 79:69-83
    • (1997) J Bone Joint Surg [Am] , vol.79 , pp. 69-83
    • Kaneda, K.1    Taneichi, H.2    Abumi, K.3    Hashimoto, T.4    Satoh, S.5    Fujiya, M.6
  • 19
    • 0030852308 scopus 로고    scopus 로고
    • Fractures of the thoracolumbar spine. Late results and consequences of dorsal instrumentation
    • Knop C, Blauth M, Bastian L, Lange U, Kesting J, Tscherne H (1997) Fractures of the thoracolumbar spine. Late results and consequences of dorsal instrumentation. Unfallchirurg 100:630-639
    • (1997) Unfallchirurg , vol.100 , pp. 630-639
    • Knop, C.1    Blauth, M.2    Bastian, L.3    Lange, U.4    Kesting, J.5    Tscherne, H.6
  • 20
    • 0023917304 scopus 로고
    • Anterior fixation for burst fractures of the thoracic and lumbar spine with or without neurological involvement
    • Kostuik JP (1988) Anterior fixation for burst fractures of the thoracic and lumbar spine with or without neurological involvement. Spine 13:286-293
    • (1988) Spine , vol.13 , pp. 286-293
    • Kostuik, J.P.1
  • 21
    • 0025973696 scopus 로고
    • Biomechanics of thoracolumbar spinal fixation
    • 3 Suppl
    • Krag MH (1991) Biomechanics of thoracolumbar spinal fixation. A review. Spine 16(3 Suppl):84-99
    • (1991) A Review. Spine , vol.16 , pp. 84-99
    • Krag, M.H.1
  • 22
    • 0031053102 scopus 로고    scopus 로고
    • Biomechanical evaluation of anterior and posterior fixations in an unstable calf spine model
    • Lim TH, An HS, Hong JH, Ahn JY, You JW, Eck J, McGrady LM (1997) Biomechanical evaluation of anterior and posterior fixations in an unstable calf spine model. Spine 22:261-266
    • (1997) Spine , vol.22 , pp. 261-266
    • Lim, T.H.1    An, H.S.2    Hong, J.H.3    Ahn, J.Y.4    You, J.W.5    Eck, J.6    McGrady, L.M.7
  • 23
  • 24
    • 0025100578 scopus 로고
    • A biomechanical investigation of short segment spinal fixation for burst fractures with varying degrees of posterior disruption
    • Mann KA, McGowan DP, Frdrickson BE, Falahee M, Yuan HA (1990) A biomechanical investigation of short segment spinal fixation for burst fractures with varying degrees of posterior disruption. Spine 15:470-478
    • (1990) Spine , vol.15 , pp. 470-478
    • Mann, K.A.1    McGowan, D.P.2    Frdrickson, B.E.3    Falahee, M.4    Yuan, H.A.5
  • 25
    • 0028149790 scopus 로고
    • Complications of anterior approaches to the thoracolumbar spine. Emphasis on Kaneda instrumentation
    • McAfee PC (1994) Complications of anterior approaches to the thoracolumbar spine. Emphasis on Kaneda instrumentation. Clin Orthop 306:110-119
    • (1994) Clin Orthop , vol.306 , pp. 110-119
    • McAfee, P.C.1
  • 26
    • 3543149451 scopus 로고    scopus 로고
    • Limitations of dorsal transpedicular stabilization in unstable fractures of the lower thoracic and lumbar spine: An analysis of 133 patients
    • Oertel J, Niendorf W-R, Darwish N, Schroeder HWS, Gaab MR (2004) Limitations of dorsal transpedicular stabilization in unstable fractures of the lower thoracic and lumbar spine: an analysis of 133 patients. Acta Neurochir Wien 146:771-777
    • (2004) Acta Neurochir Wien , vol.146 , pp. 771-777
    • Oertel, J.1    Niendorf, W.-R.2    Darwish, N.3    Schroeder, H.W.S.4    Gaab, M.R.5
  • 27
    • 0032840674 scopus 로고    scopus 로고
    • Thoracoscopy-guided management of the "anterior column". Methods and results
    • Potulski M, Beisse R, Bühren V (1999) Thoracoscopy-guided management of the "anterior column". Methods and results. Orthopäde 28:723-730
    • (1999) Orthopäde , vol.28 , pp. 723-730
    • Potulski, M.1    Beisse, R.2    Bühren, V.3
  • 28
    • 21544439313 scopus 로고    scopus 로고
    • Comparison of the biomechanical effects of posterior and anterior spine-stabilizing implants
    • Rohlmann A, Zander T, Bergmann G (2005) Comparison of the biomechanical effects of posterior and anterior spine-stabilizing implants. Eur Spine J 14:445-453
    • (2005) Eur Spine J , vol.14 , pp. 445-453
    • Rohlmann, A.1    Zander, T.2    Bergmann, G.3
  • 31
    • 16344390974 scopus 로고    scopus 로고
    • Is a single antero lateral screw-plate fixation for the treatment of spinal fractures in the thoracolumbar junction sufficient? a biomechanical in vitro investigation
    • Schreiber U, Bence T, Grupp T, Steinhauser E, Mückley T, Mittelmeier W, Beisse R (2005) Is a single antero lateral screw-plate fixation for the treatment of spinal fractures in the thoracolumbar junction sufficient? A biomechanical in vitro investigation. Eur Spine J 14:197-204
    • (2005) Eur Spine J , vol.14 , pp. 197-204
    • Schreiber, U.1    Bence, T.2    Grupp, T.3    Steinhauser, E.4    Mückley, T.5    Mittelmeier, W.6    Beisse, R.7
  • 32
    • 1842787748 scopus 로고    scopus 로고
    • Thoracolumbar fracture stabilization: Comparative biomechanical evaluation of a new video-assisted implantable system
    • Schultheiss M, Hartwig E, Kinzl L, Claes L, Wilke HJ (2004) Thoracolumbar fracture stabilization: comparative biomechanical evaluation of a new video-assisted implantable system. Eur Spine J 13:93-100
    • (2004) Eur Spine J , vol.13 , pp. 93-100
    • Schultheiss, M.1    Hartwig, E.2    Kinzl, L.3    Claes, L.4    Wilke, H.J.5
  • 33
    • 0029035767 scopus 로고
    • Instability of the lumbar burst fracture and limitations of transpedicular instrumentation
    • Slosar PJ, Patwardhan AG, Lorenz M, Havey R, Sartori M (1995) Instability of the lumbar burst fracture and limitations of transpedicular instrumentation. Spine 20:1452-1461
    • (1995) Spine , vol.20 , pp. 1452-1461
    • Slosar, P.J.1    Patwardhan, A.G.2    Lorenz, M.3    Havey, R.4    Sartori, M.5
  • 34
    • 0031924426 scopus 로고    scopus 로고
    • Testing criteria for spinal implants: Recommendations for the standardization of in vitro stability testing of the spinal implants
    • Wilke HJ, Wenger K, Claes LE (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of the spinal implants. Eur Spine J 7:148-154
    • (1998) Eur Spine J , vol.7 , pp. 148-154
    • Wilke, H.J.1    Wenger, K.2    Claes, L.E.3
  • 35
    • 0034992658 scopus 로고    scopus 로고
    • Combined anteroposterior spinal fixation provides superior stabilisation to a single anterior or posterior procedure
    • Wilke HJ, Kemmerich V, Claes LE, Arand M (2001) Combined anteroposterior spinal fixation provides superior stabilisation to a single anterior or posterior procedure. J Bone Joint Surg [Br] 83:609-617
    • (2001) J Bone Joint Surg [Br] , vol.83 , pp. 609-617
    • Wilke, H.J.1    Kemmerich, V.2    Claes, L.E.3    Arand, M.4
  • 36
    • 0028954044 scopus 로고
    • The effect of pedicle screw/plate fixation on lumbar/lumbosacral autogenous bone graft fusions in patients with degenerative disc disease
    • Wood GW 2nd, Boyd RJ, Carothers TA, Mansfield FL, Rechtine GL, Rozen MJ, Sutterlin CE 3rd (1995) The effect of pedicle screw/plate fixation on lumbar/lumbosacral autogenous bone graft fusions in patients with degenerative disc disease. Spine 20:819-830
    • (1995) Spine , vol.20 , pp. 819-830
    • Wood II, G.W.1    Boyd, R.J.2    Carothers, T.A.3    Mansfield, F.L.4    Rechtine, G.L.5    Rozen, M.J.6    Sutterlin III, C.E.7
  • 37
    • 21344444781 scopus 로고    scopus 로고
    • Anterior versus posterior treatment of stable thoracolumbar burst fractures without neurologic deficit. a prospective, randomized study
    • Suppl 1
    • Wood KB, Bohn D, Mehbod A (2005) Anterior versus posterior treatment of stable thoracolumbar burst fractures without neurologic deficit. A prospective, randomized study. J Spinal Disord Tech 18(Suppl 1):S15-S23
    • (2005) J Spinal Disord Tech , vol.18
    • Wood, K.B.1    Bohn, D.2    Mehbod, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.