-
1
-
-
0033496776
-
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
-
Calamante F., Thomas D. L., Pell G. S. et al. Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques. J Cer Blood Flow Metab: 1999; 19 701 735
-
(1999)
J Cer Blood Flow Metab
, vol.19
, pp. 701-735
-
-
Calamante, F.1
Thomas, D.L.2
Pell, G.S.3
-
2
-
-
18244399897
-
Magnetic Resonance perfusion-weighted imaging of acute cerebral infarction: Effect of the calculation methods and underlying vasculopathy
-
Yamada K., Wu O., Gonzales R. G. Magnetic Resonance perfusion-weighted imaging of acute cerebral infarction: effect of the calculation methods and underlying vasculopathy. Stroke: 2002; 33 87 94
-
(2002)
Stroke
, vol.33
, pp. 87-94
-
-
Yamada, K.1
Wu, O.2
Gonzales, R.G.3
-
3
-
-
0003593367
-
-
Aufl. Stuttgart Gustav-Fischer Verlag 3-437-251-007
-
Lorenz R. J. Grundbegriffe der Biometrie. 4. Aufl. Stuttgart Gustav-Fischer Verlag: 1996; 3-437-251-007
-
(1996)
Grundbegriffe der Biometrie
, vol.4
-
-
Lorenz, R.J.1
-
5
-
-
85045372065
-
A flexible blood flow phantom capable of independently producing constant and pulsatile flow with a predictable spatial flow profile for ultrasound flow measurement validations
-
Hein I. A., O'Brian W. D. A flexible blood flow phantom capable of independently producing constant and pulsatile flow with a predictable spatial flow profile for ultrasound flow measurement validations. IEEE Transactions on Biomedical Engineering: 1992; P39
-
(1992)
IEEE Transactions on Biomedical Engineering
, pp. P39
-
-
Hein, I.A.1
O'Brian, W.D.2
-
6
-
-
0032739140
-
Comparison of Gadomer-17 and Gd-DTPA in image quality of contrast angiographies using flow phantom model
-
Jo B. J., Chung T. S., Lee M. S. et al. Comparison of Gadomer-17 and Gd-DTPA in image quality of contrast angiographies using flow phantom model. Yonsei Medical Journal: 1999; 40 413 419
-
(1999)
Yonsei Medical Journal
, vol.40
, pp. 413-419
-
-
Jo, B.J.1
Chung, T.S.2
Lee, M.S.3
-
7
-
-
85045357453
-
Three-dimensional Reconstruction of Fine Vascularity in Ultrasound Breast Imaging using Contrast-enhanced Spatial Compounding: In-vitro Analyses
-
Hansen C., Hüttebräuker N., Wilkening W. et al. Three-dimensional Reconstruction of Fine Vascularity in Ultrasound Breast Imaging using Contrast-enhanced Spatial Compounding: In-vitro Analyses. Academic Radiology: 2008; 1 18 26
-
(2008)
Academic Radiology
, vol.1
, pp. 18-26
-
-
Hansen, C.1
Hüttebräuker, N.2
Wilkening, W.3
-
8
-
-
59149092102
-
Flussuntersuchung an Strömungsphantomen im Vor- und Nachlauf stenoseförmiger Verengung mittels geschwindigkeitskodierter MRT und numerischer Simulation der Fluiddynamik
-
Lehmpfuhl M., Hao C., Martirosian et al. Flussuntersuchung an Strömungsphantomen im Vor- und Nachlauf stenoseförmiger Verengung mittels geschwindigkeitskodierter MRT und numerischer Simulation der Fluiddynamik. Biomedizinische Technik: 2009; 54 38 47
-
(2009)
Biomedizinische Technik
, vol.54
, pp. 38-47
-
-
Lehmpfuhl, M.1
Hao, C.2
Martirosian3
-
9
-
-
85045363918
-
A Phantom for Quantitative Spin Tagging Measurements
-
Proceedings 7
-
Lee G. R., Hernandez-Garcia L., Noll D. C. A Phantom for Quantitative Spin Tagging Measurements. ISMRM 2002, Proceedings 7 P97
-
ISMRM 2002
, pp. P97
-
-
Lee, G.R.1
Hernandez-Garcia, L.2
Noll, D.C.3
-
10
-
-
85045356433
-
-
Medical Engineering, American S. (Hrsg.): Summer Bioengineering Conference. American Society of Medical Engineering, Key Biscayne (Florida), 25 - 29 June 2003. Proceedings 1
-
Ku J. P., Elkins C. J., Taylor C. A. Comparison of Blood flow patterns from CFD and MRI in a bypass graft model. In: Medical Engineering, American S. (Hrsg.): Summer Bioengineering Conference. American Society of Medical Engineering, Key Biscayne (Florida), 25 - 29 June 2003. Proceedings 1 819 820
-
Comparison of Blood Flow Patterns from CFD and MRI in A Bypass Graft Model
, pp. 819-820
-
-
Ku, J.P.1
Elkins, C.J.2
Taylor, C.A.3
-
12
-
-
33646420335
-
Method to Correct Intensity Inhomogeneity in MR Images for Atherosclerosis Characterization
-
Salvado O., Hillenbrand C., Chang S. et al. Method to Correct Intensity Inhomogeneity in MR Images for Atherosclerosis Characterization. IEEE Transactions on Medical Imaging: 2006; 25 539 552
-
(2006)
IEEE Transactions on Medical Imaging
, vol.25
, pp. 539-552
-
-
Salvado, O.1
Hillenbrand, C.2
Chang, S.3
-
13
-
-
85045368834
-
Perfusions-Phantom zur computertomographischen Messung des cerebralen Blutflusses. Workshop Experimentelle Radiologie, Mainz, 13. - 14. Feb. 2009
-
Mathys C., Rybacki K., Lanzmann R. et al. Perfusions-Phantom zur computertomographischen Messung des cerebralen Blutflusses. Workshop Experimentelle Radiologie, Mainz, 13. - 14. Feb. 2009. Fortschr Röntgenstr: 2009; 181 12 15
-
(2009)
Fortschr Röntgenstr
, vol.181
, pp. 12-15
-
-
Mathys, C.1
Rybacki, K.2
Lanzmann, R.3
-
14
-
-
70349661880
-
Biological Phantom for Contrast-Media-Based Perfusion Studies with CT
-
29 Aug [Epub ahead of print]
-
Haberland U., Cordes J., Lell M. et al. Biological Phantom for Contrast-Media-Based Perfusion Studies With CT. Invest Radiol: 29 Aug 2009; [Epub ahead of print]
-
(2009)
Invest Radiol
-
-
Haberland, U.1
Cordes, J.2
Lell, M.3
-
15
-
-
0028280905
-
A perfusion phantom for the evaluation of ultrasound contrast agents
-
Hindle A. J., Perkins A. C. A perfusion phantom for the evaluation of ultrasound contrast agents. Ultrasound Med Biol: 1994; 20 309 314
-
(1994)
Ultrasound Med Biol
, vol.20
, pp. 309-314
-
-
Hindle, A.J.1
Perkins, A.C.2
-
16
-
-
85045369531
-
-
Siemens Medical Solutions, AG [Zitiert am 06.01.2010]
-
Siemens Medical Solutions, AG. Syngo Suite 3. http://www.medical.siemens.com [Zitiert am 06.01.2010]
-
Syngo Suite 3
-
-
-
18
-
-
0038083129
-
Cerebral Perfusion Imaging using Contrast-enhanced MRI
-
Keston P., Murray A. D., Jackson A. Cerebral Perfusion Imaging using Contrast-enhanced MRI. Clin Radiol: 2003; 58 505 513
-
(2003)
Clin Radiol
, vol.58
, pp. 505-513
-
-
Keston, P.1
Murray, A.D.2
Jackson, A.3
-
19
-
-
0029907308
-
High resolution measurement of cerebral blood flow using intravascular tracer bolus passage - Part 1: Mathematical approach and statistical analysis
-
Oestergaard L., Weisskoff R. M., Chesler D. A. et al. High resolution measurement of cerebral blood flow using intravascular tracer bolus passage - part 1: mathematical approach and statistical analysis. Magn Res Med: 1996; 36 715 725
-
(1996)
Magn Res Med
, vol.36
, pp. 715-725
-
-
Oestergaard, L.1
Weisskoff, R.M.2
Chesler, D.A.3
-
20
-
-
0036136806
-
Is Quantification of Bolus Tracking MRI Reliable Without Deconvolution?
-
Perthen J. E., Calamante F., Gadian D. et al. Is Quantification of Bolus Tracking MRI Reliable Without Deconvolution? Magn Res in Med: 2002; 47 61 67
-
(2002)
Magn Res in Med
, vol.47
, pp. 61-67
-
-
Perthen, J.E.1
Calamante, F.2
Gadian, D.3
-
21
-
-
0036221582
-
Quantification of perfusion using bolus tracking magnetic resonance imaging in stroke: Assumptions, Limitations and potential Implications for clinical use
-
Calamante F., Gadien D. G., Conelly A. Quantification of perfusion using bolus tracking magnetic resonance imaging in stroke: Assumptions, Limitations and potential Implications for clinical use. Stroke: 2002; 22 1146 1151
-
(2002)
Stroke
, vol.22
, pp. 1146-1151
-
-
Calamante, F.1
Gadien, D.G.2
Conelly, A.3
-
22
-
-
0028072844
-
Quantification of regional cerebral blood flow and volume by dynamic susceptibility contrast enhanced MR imaging
-
Rempp K., Brix G., Wenz F. et al. Quantification of regional cerebral blood flow and volume by dynamic susceptibility contrast enhanced MR imaging. Radiology: 1994; 194 637 641
-
(1994)
Radiology
, vol.194
, pp. 637-641
-
-
Rempp, K.1
Brix, G.2
Wenz, F.3
-
23
-
-
0026343822
-
Susceptibility contrast imaging of cerebral blood volume: Human Experience
-
Rosen B., Belliveau J., Aronen H. J. et al. Susceptibility contrast imaging of cerebral blood volume: Human Experience. Magn Res Med: 1992; 22 293 299
-
(1992)
Magn Res Med
, vol.22
, pp. 293-299
-
-
Rosen, B.1
Belliveau, J.2
Aronen, H.J.3
-
24
-
-
0344382061
-
Cerebral blood volume and cerebrovascular reserve capacity: Estimation by dynamic magnetic resonance imaging
-
Schreiber W. G., Gueckel F., Stritzke P. et al. Cerebral blood volume and cerebrovascular reserve capacity: Estimation by dynamic magnetic resonance imaging. J Cer Blood Flow Metab: 1998; 18 1143 1156
-
(1998)
J Cer Blood Flow Metab
, vol.18
, pp. 1143-1156
-
-
Schreiber, W.G.1
Gueckel, F.2
Stritzke, P.3
-
25
-
-
0343932690
-
Quantification of cerebral blood flow by bolus tracking and artery spin tagging methods
-
Lia T. Q., Guang C. Z., Oestergaard L. et al. Quantification of cerebral blood flow by bolus tracking and artery spin tagging methods. Magn Res Imag: 2000; 18 503 512
-
(2000)
Magn Res Imag
, vol.18
, pp. 503-512
-
-
Lia, T.Q.1
Guang, C.Z.2
Oestergaard, L.3
-
26
-
-
65649099246
-
Imaging in acute stroke - A personal view
-
Kuchinski T. Imaging in acute stroke - a personal view. Clin Neuroradiol: 2009; 19 20 30
-
(2009)
Clin Neuroradiol
, vol.19
, pp. 20-30
-
-
Kuchinski, T.1
|