메뉴 건너뛰기




Volumn 135, Issue 11, 2010, Pages 2930-2938

Platelet aggregation monitoring with a newly developed quartz crystal microbalance system as an alternative to optical platelet aggregometry

Author keywords

[No Author keywords available]

Indexed keywords


EID: 77958046234     PISSN: 00032654     EISSN: 13645528     Source Type: Journal    
DOI: 10.1039/c0an00474j     Document Type: Article
Times cited : (30)

References (30)
  • 1
    • 0030912108 scopus 로고    scopus 로고
    • Biocompatibility in cardiopulmonary bypass
    • L. C. Hsu Biocompatibility in cardiopulmonary bypass J. Cardiothorac. Vasc. Anesth. 1997 May 11 3 376 382
    • (1997) J. Cardiothorac. Vasc. Anesth. , vol.11 , Issue.3 , pp. 376-382
    • Hsu, L.C.1
  • 3
    • 0030979040 scopus 로고    scopus 로고
    • The inflammatory response to cardiopulmonary bypass
    • B. E. Miller J. H. Levy The inflammatory response to cardiopulmonary bypass J. Cardiothorac. Vasc. Anesth. 1997 May 11 3 355 366
    • (1997) J. Cardiothorac. Vasc. Anesth. , vol.11 , Issue.3 , pp. 355-366
    • Miller, B.E.1    Levy, J.H.2
  • 4
    • 0032460111 scopus 로고    scopus 로고
    • The platelet in cardiopulmonary bypass
    • DOI 10.1016/S0003-4975(98)00749-8, PII S0003497598007498
    • A. Weerasinghe K. M. Taylor The platelet in cardiopulmonary bypass Ann. Thorac. Surg. 1998 Dec 66 6 2145 2152 (Pubitemid 29087232)
    • (1998) Annals of Thoracic Surgery , vol.66 , Issue.6 , pp. 2145-2152
    • Weerasinghe, A.1    Taylor, K.M.2
  • 5
    • 0031731256 scopus 로고    scopus 로고
    • Platelets and cardiopulmonary bypass
    • J. A. Hyde J. A. Chinn T. R. Graham Platelets and cardiopulmonary bypass Perfusion 1998 Nov 13 6 389 407
    • (1998) Perfusion , vol.13 , Issue.6 , pp. 389-407
    • Hyde, J.A.1    Chinn, J.A.2    Graham, T.R.3
  • 6
    • 58549112177 scopus 로고    scopus 로고
    • CD41 Western blotting: A new method to detect platelet adhesion to artificial surfaces used in extracorporeal circulation procedures
    • A. Paul A. Straub N. Weber G. Ziemer H. P. Wendel CD41 Western blotting: a new method to detect platelet adhesion to artificial surfaces used in extracorporeal circulation procedures J. Mater. Sci.: Mater. Med. 2009 Jan 20 1 373 378
    • (2009) J. Mater. Sci.: Mater. Med. , vol.20 , Issue.1 , pp. 373-378
    • Paul, A.1    Straub, A.2    Weber, N.3    Ziemer, G.4    Wendel, H.P.5
  • 7
    • 70649114517 scopus 로고    scopus 로고
    • The relationship between platelet adhesion on surfaces and the structure versus the amount of adsorbed fibrinogen
    • B. Sivaraman R. A. Latour The relationship between platelet adhesion on surfaces and the structure versus the amount of adsorbed fibrinogen Biomaterials 2010 Feb 31 5 832 839
    • (2010) Biomaterials , vol.31 , Issue.5 , pp. 832-839
    • Sivaraman, B.1    Latour, R.A.2
  • 8
    • 38849184158 scopus 로고    scopus 로고
    • Point-of-care platelet function testing
    • C. C. Harle Point-of-care platelet function testing Semin. Cardiothorac. Vasc. Anesth. 2007 Dec 11 4 247 251
    • (2007) Semin. Cardiothorac. Vasc. Anesth. , vol.11 , Issue.4 , pp. 247-251
    • Harle, C.C.1
  • 9
    • 33645852553 scopus 로고    scopus 로고
    • Correlation of perioperative platelet function and coagulation tests with bleeding after cardiopulmonary bypass surgery
    • R. C. Carroll J. J. Chavez C. C. Snider D. S. Meyer R. A. Muenchen Correlation of perioperative platelet function and coagulation tests with bleeding after cardiopulmonary bypass surgery J. Lab. Clin. Med. 2006 Apr 147 4 197 204
    • (2006) J. Lab. Clin. Med. , vol.147 , Issue.4 , pp. 197-204
    • Carroll, R.C.1    Chavez, J.J.2    Snider, C.C.3    Meyer, D.S.4    Muenchen, R.A.5
  • 11
    • 38749143283 scopus 로고    scopus 로고
    • Evaluation of a New Platelet Function Analyzer in Cardiac Surgery: A Comparison of Modified Thromboelastography and Whole-Blood Aggregometry
    • DOI 10.1053/j.jvca.2007.02.015, PII S1053077007000547
    • A. M. Mengistu M. W. Wolf J. Boldt K. D. Rohm J. Lang S. N. Piper Evaluation of a new platelet function analyzer in cardiac surgery: a comparison of modified thromboelastography and whole-blood aggregometry J. Cardiothorac. Vasc. Anesth. 2008 Feb 22 1 40 46 (Pubitemid 351179383)
    • (2008) Journal of Cardiothoracic and Vascular Anesthesia , vol.22 , Issue.1 , pp. 40-46
    • Mengistu, A.M.1    Wolf, M.W.2    Boldt, J.3    Rohm, K.D.4    Lang, J.5    Piper, S.N.6
  • 12
    • 75649123829 scopus 로고    scopus 로고
    • Investigation of prothrombin time in human whole-blood samples with a quartz crystal biosensor
    • L. Muller S. Sinn H. Drechsel C. Ziegler H. P. Wendel H. Northoff et al., Investigation of prothrombin time in human whole-blood samples with a quartz crystal biosensor Anal. Chem. 2010 Jan 82 2 658 663
    • (2010) Anal. Chem. , vol.82 , Issue.2 , pp. 658-663
    • Muller, L.1    Sinn, S.2    Drechsel, H.3    Ziegler, C.4    Wendel, H.P.5    Northoff, H.6
  • 13
    • 34447498398 scopus 로고    scopus 로고
    • A survey of the 2001 to 2005 quartz crystal microbalance biosensor literature: Applications of acoustic physics to the analysis of biomolecular interactions
    • M. A. Cooper V. T. Singleton A survey of the 2001 to 2005 quartz crystal microbalance biosensor literature: applications of acoustic physics to the analysis of biomolecular interactions J. Mol. Recognit. 2007 May 20 3 154 184
    • (2007) J. Mol. Recognit. , vol.20 , Issue.3 , pp. 154-184
    • Cooper, M.A.1    Singleton, V.T.2
  • 14
    • 70349266447 scopus 로고    scopus 로고
    • Synthetic receptors for selectively detecting erythrocyte ABO subgroups
    • A. Seifner P. Lieberzeit C. Jungbauer F. L. Dickert Synthetic receptors for selectively detecting erythrocyte ABO subgroups Anal. Chim. Acta 2009 Oct 5 651 2 215 219
    • (2009) Anal. Chim. Acta , vol.651 , Issue.2 , pp. 215-219
    • Seifner, A.1    Lieberzeit, P.2    Jungbauer, C.3    Dickert, F.L.4
  • 15
    • 0035660370 scopus 로고    scopus 로고
    • Sequences of E. coli O157:H7 detected by a PCR-acoustic wave sensor combination
    • DOI 10.1039/b107117n
    • A. K. Deisingh M. Thompson Sequences of E. coli O157:H7 detected by a PCR-acoustic wave sensor combination Analyst 2001 Dec 126 12 2153 2158 (Pubitemid 34017022)
    • (2001) Analyst , vol.126 , Issue.12 , pp. 2153-2158
    • Deisingh, A.K.1    Thompson, M.2
  • 18
    • 33846874159 scopus 로고    scopus 로고
    • Concentration-dependent effect of abciximab on platelets and neutrophils in a model of cardiopulmonary bypass
    • DOI 10.1177/0267659106070509
    • A. E. Asberg V. Videm Concentration-dependent effect of abciximab on platelets and neutrophils in a model of cardiopulmonary bypass Perfusion 2006 Nov 21 6 343 352 (Pubitemid 46218362)
    • (2006) Perfusion , vol.21 , Issue.6 , pp. 343-352
    • Asberg, A.E.1    Videm, V.2
  • 22
    • 65849268320 scopus 로고    scopus 로고
    • Aspirin in the primary and secondary prevention of vascular disease: Collaborative meta-analysis of individual participant data from randomised trials
    • C. Baigent L. Blackwell R. Collins J. Emberson J. Godwin R. Peto et al., Aspirin in the primary and secondary prevention of vascular disease: collaborative meta-analysis of individual participant data from randomised trials Lancet 2009 May 30 373 9678 1849 1860
    • (2009) Lancet , vol.373 , Issue.9678 , pp. 1849-1860
    • Baigent, C.1    Blackwell, L.2    Collins, R.3    Emberson, J.4    Godwin, J.5    Peto, R.6
  • 23
    • 45849125010 scopus 로고    scopus 로고
    • Platelet anaesthesia during extracorporeal circulation: Differential effects of GP IIb/IIIa blockers on platelet activation marker P-selectin expression at hypothermia
    • A. Straub D. Schiebold H. P. Wendel R. Azevedo K. Dietz G. Ziemer Platelet anaesthesia during extracorporeal circulation: differential effects of GP IIb/IIIa blockers on platelet activation marker P-selectin expression at hypothermia Thromb. Res. 2008 122 3 383 389
    • (2008) Thromb. Res. , vol.122 , Issue.3 , pp. 383-389
    • Straub, A.1    Schiebold, D.2    Wendel, H.P.3    Azevedo, R.4    Dietz, K.5    Ziemer, G.6
  • 24
    • 0033080578 scopus 로고    scopus 로고
    • Human plasma fibrinogen adsorption and platelet adhesion to polystyrene
    • DOI 10.1002/(SICI)1097-4636(199902)44 :2<130::AID-JBM2>3.0.CO;2-9
    • W. B. Tsai J. M. Grunkemeier T. A. Horbett Human plasma fibrinogen adsorption and platelet adhesion to polystyrene J. Biomed. Mater. Res. 1999 Feb 44 2 130 139 (Pubitemid 28566800)
    • (1999) Journal of Biomedical Materials Research , vol.44 , Issue.2 , pp. 130-139
    • Tsai, W.-B.1    Grunkemeier, J.M.2    Horbett, T.A.3
  • 25
    • 66249146409 scopus 로고    scopus 로고
    • Tetraglyme coatings reduce fibrinogen and von Willebrand factor adsorption and platelet adhesion under both static and flow conditions
    • M. Zhang T. A. Horbett Tetraglyme coatings reduce fibrinogen and von Willebrand factor adsorption and platelet adhesion under both static and flow conditions J. Biomed. Mater. Res., Part A 2009 Jun 89 3 791 803
    • (2009) J. Biomed. Mater. Res., Part A , vol.89 , Issue.3 , pp. 791-803
    • Zhang, M.1    Horbett, T.A.2
  • 26
    • 0035010395 scopus 로고    scopus 로고
    • Kinetics and thermodynamics of protein adsorption: A generalized molecular theoretical approach
    • F. Fang I. Szleifer Kinetics and thermodynamics of protein adsorption: a generalized molecular theoretical approach Biophys. J. 2001 Jun 80 6 2568 2589 (Pubitemid 32521634)
    • (2001) Biophysical Journal , vol.80 , Issue.6 , pp. 2568-2589
    • Fang, F.1    Szleifer, I.2
  • 28
    • 84951279351 scopus 로고
    • Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung
    • G. Sauerbrey Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung Z. Phys. 1959 Feb 21 155 206 222
    • (1959) Z. Phys. , vol.155 , pp. 206-222
    • Sauerbrey, G.1
  • 29
    • 0035068514 scopus 로고    scopus 로고
    • Blood platelet adhesion to protein studied by on-line acoustic wave sensor
    • DOI 10.1039/b009254l
    • B. A. Cavic J. Freedman Z. Morel M. Mody M. L. Rand D. C. Stone et al., Blood platelet adhesion to protein studied by on-line acoustic wave sensor Analyst 2001 Mar 126 3 342 348 (Pubitemid 32238838)
    • (2001) Analyst , vol.126 , Issue.3 , pp. 342-348
    • Cavic, B.A.1    Freedman, J.2    Morel, Z.3    Mody, M.4    Rand, M.L.5    Stone, D.C.6    Thompson, M.7
  • 30
    • 33749368345 scopus 로고    scopus 로고
    • Fundamentals of mass measurements
    • V. M. Mecea Fundamentals of mass measurements J. Therm. Anal. Calorim. 2006 86 1 9 16
    • (2006) J. Therm. Anal. Calorim. , vol.86 , Issue.1 , pp. 9-16
    • Mecea, V.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.