메뉴 건너뛰기




Volumn 11, Issue 3, 1997, Pages 376-382

Biocompatibility in cardiopulmonary bypass

Author keywords

biocompatibility; blood material interactions; cardiopulmonary bypass; control of blood activation; heparin coating

Indexed keywords

BIOCOMPATIBILITY; BLEEDING TENDENCY; BLOOD CLOTTING; BLOOD FLOW VELOCITY; CARDIOPULMONARY BYPASS; CARDIOPULMONARY HEMODYNAMICS; CELL INTERACTION; COMPLEMENT ACTIVATION; EXTRACORPOREAL CIRCULATION; HUMAN; OXYGENATOR; PRIORITY JOURNAL; REVIEW; SURGICAL TECHNIQUE;

EID: 0030912108     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1053-0770(97)90108-7     Document Type: Review
Times cited : (49)

References (79)
  • 1
    • 0026642019 scopus 로고
    • Efficacy, complication and cost of a comprehensive blood conservation program for cardiac operations
    • Scott WJ, Rode R, Castelmain B, et al: Efficacy, complication and cost of a comprehensive blood conservation program for cardiac operations. J Thorac Cardiovasc Surg 103:1001-1007, 1992
    • (1992) J Thorac Cardiovasc Surg , vol.103 , pp. 1001-1007
    • Scott, W.J.1    Rode, R.2    Castelmain, B.3
  • 2
    • 0027435353 scopus 로고
    • Activation of fibrinolysis in the pericardial cavity during cardiopulmonary bypass
    • Tabuchi N, de Haan J, Boonstra PW, et al: Activation of fibrinolysis in the pericardial cavity during cardiopulmonary bypass. J Thorac Cardiovasc Surg 106:828-833, 1993
    • (1993) J Thorac Cardiovasc Surg , vol.106 , pp. 828-833
    • Tabuchi, N.1    De Haan, J.2    Boonstra, P.W.3
  • 4
    • 0026695183 scopus 로고
    • Effect of skin temperature on platelet function in patients undergoing extracorporeal bypass
    • Valeri CR, Khabbaz K, Khuri SF, et al: Effect of skin temperature on platelet function in patients undergoing extracorporeal bypass. J Thorac Cardiovasc Surg 104:108-116, 1992
    • (1992) J Thorac Cardiovasc Surg , vol.104 , pp. 108-116
    • Valeri, C.R.1    Khabbaz, K.2    Khuri, S.F.3
  • 5
    • 0030070802 scopus 로고    scopus 로고
    • The microvascular cell and ischemia-reperfusion injury
    • Varrier E: The microvascular cell and ischemia-reperfusion injury. J Cardiovasc Pharmacol 27:526-530, 1996 (suppl 1)
    • (1996) J Cardiovasc Pharmacol , vol.27 , Issue.1 SUPPL. , pp. 526-530
    • Varrier, E.1
  • 6
    • 37049044629 scopus 로고
    • An enzyme cascade in the blood clotting mechanism, and its function as a biological amplifier
    • MacFarlane RG: An enzyme cascade in the blood clotting mechanism, and its function as a biological amplifier. Nature 202:498, 1964
    • (1964) Nature , vol.202 , pp. 498
    • MacFarlane, R.G.1
  • 8
    • 0025995594 scopus 로고
    • Heparin coating of extracorporeal circuits reduces thrombin formation in patients undergoing cardiopulmonary bypass
    • Gu YJ, van Oeveren W, van der Kamp KWHJ, et al: Heparin coating of extracorporeal circuits reduces thrombin formation in patients undergoing cardiopulmonary bypass. Perfusion 6:221-225, 1991
    • (1991) Perfusion , vol.6 , pp. 221-225
    • Gu, Y.J.1    Van Oeveren, W.2    Van Der Kamp, K.W.H.J.3
  • 9
    • 0029797022 scopus 로고    scopus 로고
    • Activation of coagulation and fibrinolytic pathways in patients with left ventricular assist devices
    • Spanier T, Oz M, Levin H, et al: Activation of coagulation and fibrinolytic pathways in patients with left ventricular assist devices. J Thorac Cardiovasc Surg 112:1090-1097, 1996
    • (1996) J Thorac Cardiovasc Surg , vol.112 , pp. 1090-1097
    • Spanier, T.1    Oz, M.2    Levin, H.3
  • 10
    • 0029740551 scopus 로고    scopus 로고
    • Recurrent thrombosis of biventricular-support devices associated with accelerated intravascular coagulation and increased heparin requirements
    • Despotis GJ, Levine V, Alsoufiev A, et al: Recurrent thrombosis of biventricular-support devices associated with accelerated intravascular coagulation and increased heparin requirements. J Thorac Cardiovasc Surg 112:538-540, 1996
    • (1996) J Thorac Cardiovasc Surg , vol.112 , pp. 538-540
    • Despotis, G.J.1    Levine, V.2    Alsoufiev, A.3
  • 11
    • 0022339265 scopus 로고
    • Evidence for complement activation by heparin-protamine interaction after cardiopulmonary bypass
    • Cavarocchi NC, Schaff HV, Orszulak TA, et al: Evidence for complement activation by heparin-protamine interaction after cardiopulmonary bypass. Surgery 98:525-531, 1985
    • (1985) Surgery , vol.98 , pp. 525-531
    • Cavarocchi, N.C.1    Schaff, H.V.2    Orszulak, T.A.3
  • 12
    • 0030027446 scopus 로고    scopus 로고
    • Amplification of the inflammatory response: Adhesion molecules associated with platelet/white cell responses
    • Rinder C, Fitch J: Amplification of the inflammatory response: Adhesion molecules associated with platelet/white cell responses. J Cardiovasc Pharmacol 27:S6-S12, 1996 (suppl 1)
    • (1996) J Cardiovasc Pharmacol , vol.27 , Issue.1 SUPPL.
    • Rinder, C.1    Fitch, J.2
  • 13
    • 0026525226 scopus 로고
    • Natural and synthetic antifibrinolytics in cardiac surgery
    • Hardy J, Desroches J: Natural and synthetic antifibrinolytics in cardiac surgery. Can J Anaesth 39:353-365, 1992
    • (1992) Can J Anaesth , vol.39 , pp. 353-365
    • Hardy, J.1    Desroches, J.2
  • 14
    • 0345045304 scopus 로고
    • Effects of cardiopulmonary bypass on hemostasis
    • Loscalzo J, Schafer AI (eds): Cambridge, UK, Blackwell
    • Khuri SF, Michelson AD, Valeri CR: Effects of cardiopulmonary bypass on hemostasis, in Loscalzo J, Schafer AI (eds): Thrombosis and Hemorrhage. Cambridge, UK, Blackwell, 1993, pp 1051-1073
    • (1993) Thrombosis and Hemorrhage , pp. 1051-1073
    • Khuri, S.F.1    Michelson, A.D.2    Valeri, C.R.3
  • 15
    • 0013940493 scopus 로고    scopus 로고
    • The pathogenesis and control of the hemorrhagic defect in open heart surgery
    • Kevy SV, Glickman RM, Bernhard WF, et al: The pathogenesis and control of the hemorrhagic defect in open heart surgery. Surg Gynecol Obstet 123:313-318, 1996
    • (1996) Surg Gynecol Obstet , vol.123 , pp. 313-318
    • Kevy, S.V.1    Glickman, R.M.2    Bernhard, W.F.3
  • 16
    • 0029835945 scopus 로고    scopus 로고
    • Biocompatibility in heparin-coated extracorporeal circuits
    • Hsu LC: Biocompatibility in heparin-coated extracorporeal circuits. Perfusion 11:256-263, 1996
    • (1996) Perfusion , vol.11 , pp. 256-263
    • Hsu, L.C.1
  • 19
    • 0024309522 scopus 로고
    • Different activation patterns in the plasma kallikrein-kinin and complement systems during coronary bypass surgery
    • Kongsgaard UE, Smith-Erichsen N, Geiran O, et al: Different activation patterns in the plasma kallikrein-kinin and complement systems during coronary bypass surgery. Acta Anaesthesiol Scand 33:343-347, 1989
    • (1989) Acta Anaesthesiol Scand , vol.33 , pp. 343-347
    • Kongsgaard, U.E.1    Smith-Erichsen, N.2    Geiran, O.3
  • 20
    • 0028793755 scopus 로고
    • Breaking the blood-biomaterial barrier
    • Edmunds LH Jr: Breaking the blood-biomaterial barrier. ASAIO J 41:824-830, 1995
    • (1995) ASAIO J , vol.41 , pp. 824-830
    • Edmunds Jr., L.H.1
  • 21
    • 0022177332 scopus 로고
    • Acute lung injury during cardiopulmonary bypass: The role of neutrophil sequestration and lipid peroxidation
    • Westaby S, Fleming JS, Royston D: Acute lung injury during cardiopulmonary bypass: The role of neutrophil sequestration and lipid peroxidation. ASAIO J 31:604, 1985
    • (1985) ASAIO J , vol.31 , pp. 604
    • Westaby, S.1    Fleming, J.S.2    Royston, D.3
  • 22
    • 0025304016 scopus 로고
    • Cytokines and endothelial cell biology
    • Pober JS, Contran RS: Cytokines and endothelial cell biology. Physiol Rev 70:427-451, 1990
    • (1990) Physiol Rev , vol.70 , pp. 427-451
    • Pober, J.S.1    Contran, R.S.2
  • 23
    • 0028143867 scopus 로고
    • Relationship of the proinflammatory cytokines to myocardial ischemia and dysfunction after uncomplicated coronary revascularization
    • Hennein HA, Ebba H, Rodriguez JL, et al: Relationship of the proinflammatory cytokines to myocardial ischemia and dysfunction after uncomplicated coronary revascularization. J Thorac Cardiovasc Surg 108:626-635, 1994
    • (1994) J Thorac Cardiovasc Surg , vol.108 , pp. 626-635
    • Hennein, H.A.1    Ebba, H.2    Rodriguez, J.L.3
  • 24
    • 0030248216 scopus 로고    scopus 로고
    • Endothelial cell injury in cardiovascular surgery
    • Verrier ED, Boyle EM: Endothelial cell injury in cardiovascular surgery. Ann Thorac Surg 62:915-922, 1996
    • (1996) Ann Thorac Surg , vol.62 , pp. 915-922
    • Verrier, E.D.1    Boyle, E.M.2
  • 25
    • 0029938973 scopus 로고    scopus 로고
    • Circulating endothelin in cardiac operations: Influence of blood pressure and endotoxin
    • te Velthuis H, Jansen PGM, Oudemans-van Straaten HM, et al: Circulating endothelin in cardiac operations: Influence of blood pressure and endotoxin. Ann Thorac Surg 61:904-908, 1996
    • (1996) Ann Thorac Surg , vol.61 , pp. 904-908
    • Te Velthuis, H.1    Jansen, P.G.M.2    Oudemans-van Straaten, H.M.3
  • 26
    • 0028835469 scopus 로고
    • Neutrophil antiadhesion therapy for myocardial ischemia: Clinical potential
    • Johnson MJ, Pohlman TH, Verrier ED: Neutrophil antiadhesion therapy for myocardial ischemia: Clinical potential. Clin Immunother 3:8-14, 1995
    • (1995) Clin Immunother , vol.3 , pp. 8-14
    • Johnson, M.J.1    Pohlman, T.H.2    Verrier, E.D.3
  • 27
    • 0023608558 scopus 로고
    • Effects of aprotinin on hemostatic mechanisms during cardiopulmonary bypass
    • van Oeveren W, Jansen NJG, Bidstrup BP, et al: Effects of aprotinin on hemostatic mechanisms during cardiopulmonary bypass. Ann Thorac Surg 44:640-645, 1987
    • (1987) Ann Thorac Surg , vol.44 , pp. 640-645
    • Van Oeveren, W.1    Jansen, N.J.G.2    Bidstrup, B.P.3
  • 28
    • 0030119292 scopus 로고    scopus 로고
    • Influence of low-dose aprotinin on inflammatory reaction due to cardiopulmonary bypass in children
    • Seghaye M-C, Duchateau J, Grabitz RG, et al: Influence of low-dose aprotinin on inflammatory reaction due to cardiopulmonary bypass in children. Ann Thorac Surg 61:1205-1211, 1996
    • (1996) Ann Thorac Surg , vol.61 , pp. 1205-1211
    • Seghaye, M.-C.1    Duchateau, J.2    Grabitz, R.G.3
  • 29
    • 0029783280 scopus 로고    scopus 로고
    • Low-dose and high-dose aprotinin improve hemostasis in coronary operations
    • Speekenbrink RGH, Wildevuur CRH, Sturk A, et al: Low-dose and high-dose aprotinin improve hemostasis in coronary operations. J Thorac Cardiovasc Surg 112:523-530, 1996
    • (1996) J Thorac Cardiovasc Surg , vol.112 , pp. 523-530
    • Speekenbrink, R.G.H.1    Wildevuur, C.R.H.2    Sturk, A.3
  • 30
    • 0030296360 scopus 로고    scopus 로고
    • Nafamostat mesilate reduces blood-foreign surface reactions similar to biocompatible materials
    • Usui A, Hiroura M, Kawamura M, et al: Nafamostat mesilate reduces blood-foreign surface reactions similar to biocompatible materials. Ann Thorac Surg 62:1404-1411, 1996
    • (1996) Ann Thorac Surg , vol.62 , pp. 1404-1411
    • Usui, A.1    Hiroura, M.2    Kawamura, M.3
  • 31
    • 0030027925 scopus 로고    scopus 로고
    • Attenuation of cardiopulmonary bypass-derived inflammatory reactions reduces myocardial reperfusion injury in cardiac operations
    • Sawa Y, Shimazaki Y, Kadoba K, et al: Attenuation of cardiopulmonary bypass-derived inflammatory reactions reduces myocardial reperfusion injury in cardiac operations. J Thorac Cardiovasc Surg 111:29-35, 1996
    • (1996) J Thorac Cardiovasc Surg , vol.111 , pp. 29-35
    • Sawa, Y.1    Shimazaki, Y.2    Kadoba, K.3
  • 32
    • 0024509887 scopus 로고
    • Reduction in blood loss and blood use after cardiopulmonary bypass with high dose aprotinin
    • Bidstrup BP, Royston D, Sapsford RN, et al: Reduction in blood loss and blood use after cardiopulmonary bypass with high dose aprotinin. J Thorac Cardiovasc Surg 97:364-372, 1989
    • (1989) J Thorac Cardiovasc Surg , vol.97 , pp. 364-372
    • Bidstrup, B.P.1    Royston, D.2    Sapsford, R.N.3
  • 33
    • 10244240505 scopus 로고    scopus 로고
    • Reduction of bleeding after heart operations through the prophylactic use of epsilon-aminocaproic acid
    • Vander Salm T, Kaur S, Lancey RA, et al: Reduction of bleeding after heart operations through the prophylactic use of epsilon-aminocaproic acid. J Thorac Cardiovasc Surg 112:1098-1117, 1996
    • (1996) J Thorac Cardiovasc Surg , vol.112 , pp. 1098-1117
    • Vander Salm, T.1    Kaur, S.2    Lancey, R.A.3
  • 34
    • 0028940667 scopus 로고
    • Tranexamic acid significantly reduces blood loss associated with coronary revascularization
    • Rousou JA, Engelman RM, Flack JE, et al: Tranexamic acid significantly reduces blood loss associated with coronary revascularization. Ann Thorac Surg 59:671-675, 1995
    • (1995) Ann Thorac Surg , vol.59 , pp. 671-675
    • Rousou, J.A.1    Engelman, R.M.2    Flack, J.E.3
  • 35
    • 0030117128 scopus 로고    scopus 로고
    • Tranexamic acid reduces postbypass blood use: A double-blinded, prospective, randomized study of 210 patients
    • Katsaros D, Petricevic M, Snow NJ, et al: Tranexamic acid reduces postbypass blood use: A double-blinded, prospective, randomized study of 210 patients. Ann Thorac Surg 61:1131-1135, 1996
    • (1996) Ann Thorac Surg , vol.61 , pp. 1131-1135
    • Katsaros, D.1    Petricevic, M.2    Snow, N.J.3
  • 36
    • 0029992772 scopus 로고    scopus 로고
    • Inhaled nitric oxide: Therapeutic applications in cardiothoracic surgery
    • Fullerton DA, McIntyre RC: Inhaled nitric oxide: Therapeutic applications in cardiothoracic surgery. Ann Thorac Surg 61:1856-1864, 1996
    • (1996) Ann Thorac Surg , vol.61 , pp. 1856-1864
    • Fullerton, D.A.1    McIntyre, R.C.2
  • 37
    • 0030246951 scopus 로고    scopus 로고
    • Adverse effects of postoperative infusion of shed mediastinal blood
    • Vertrees RA, Conti VR, Lick SD, et al: Adverse effects of postoperative infusion of shed mediastinal blood. Ann Thorac Surg 62:717-723, 1996
    • (1996) Ann Thorac Surg , vol.62 , pp. 717-723
    • Vertrees, R.A.1    Conti, V.R.2    Lick, S.D.3
  • 38
    • 0025373760 scopus 로고
    • Leukocyte depletion ameliorates free-radical mediated lung injury after cardiopulmonary bypass
    • Bando K, Pillai R, Cameron DE, et al: Leukocyte depletion ameliorates free-radical mediated lung injury after cardiopulmonary bypass. J Thorac Cardiovasc Surg 99:873-897, 1990
    • (1990) J Thorac Cardiovasc Surg , vol.99 , pp. 873-897
    • Bando, K.1    Pillai, R.2    Cameron, D.E.3
  • 39
    • 0029033594 scopus 로고
    • The influence of leukocyte filtration during cardiopulmonary bypass on postoperative lung function
    • Mihaljevic T, Tonz M, von Segesser LK, et al: The influence of leukocyte filtration during cardiopulmonary bypass on postoperative lung function. J Thorac Cardiovasc Surg 109:1138-1145, 1995
    • (1995) J Thorac Cardiovasc Surg , vol.109 , pp. 1138-1145
    • Mihaljevic, T.1    Tonz, M.2    Von Segesser, L.K.3
  • 40
    • 0028099590 scopus 로고
    • Pall leukocyte depleting filter during cardiopulmonary bypass
    • Al-Ebrahim, Shafei H: Pall leukocyte depleting filter during cardiopulmonary bypass [letter]. Ann Thorac Surg 58:1560-1561, 1994
    • (1994) Ann Thorac Surg , vol.58 , pp. 1560-1561
    • Al-Ebrahim1    Shafei, H.2
  • 41
    • 0029740550 scopus 로고    scopus 로고
    • Leukocyte depletion results in improved lung function and reduced inflammatory response after cardiac surgery
    • Gu YJ, de Vries AJ, Boonstra PW, et al: Leukocyte depletion results in improved lung function and reduced inflammatory response after cardiac surgery. J Thorac Surg 112:494-500, 1996
    • (1996) J Thorac Surg , vol.112 , pp. 494-500
    • Gu, Y.J.1    De Vries, A.J.2    Boonstra, P.W.3
  • 42
    • 0028819922 scopus 로고
    • Continuous hemofiltration as blood purification in sepsis
    • Bellomo R: Continuous hemofiltration as blood purification in sepsis. New Horizons 3:732-737, 1995
    • (1995) New Horizons , vol.3 , pp. 732-737
    • Bellomo, R.1
  • 43
    • 0028821990 scopus 로고
    • Continuous hemofiltration for the failing heart
    • Coraim F, Wolner E: Continuous hemofiltration for the failing heart. New Horizons 3:725-731, 1995
    • (1995) New Horizons , vol.3 , pp. 725-731
    • Coraim, F.1    Wolner, E.2
  • 44
    • 0025073168 scopus 로고
    • Influence of oxygenator type on the incidence and extent of microembolic retinal ischemia during cardiopulmonary bypass
    • Blauth C, Smith PL, Arnold JV, et al: Influence of oxygenator type on the incidence and extent of microembolic retinal ischemia during cardiopulmonary bypass. J Thorac Cardiovasc Surg 99:61-69, 1990
    • (1990) J Thorac Cardiovasc Surg , vol.99 , pp. 61-69
    • Blauth, C.1    Smith, P.L.2    Arnold, J.V.3
  • 45
    • 0019852354 scopus 로고
    • Hemodynamics in extracorporeal aortic cannula: Review of factors affecting the choice of appropriate size
    • Pfaender LM: Hemodynamics in extracorporeal aortic cannula: Review of factors affecting the choice of appropriate size. J Extracorporeal Tech 13:224-232, 1981
    • (1981) J Extracorporeal Tech , vol.13 , pp. 224-232
    • Pfaender, L.M.1
  • 46
    • 0027241269 scopus 로고
    • Heparin coating reduces blood cell adhesion to arterial filter during coronary bypass: A clinical study
    • Borowiec JW, Bylock A, van der Linden J, et al: Heparin coating reduces blood cell adhesion to arterial filter during coronary bypass: A clinical study. Ann Thorac Surg 55:1540-1545, 1993
    • (1993) Ann Thorac Surg , vol.55 , pp. 1540-1545
    • Borowiec, J.W.1    Bylock, A.2    Van Der Linden, J.3
  • 47
    • 0025936767 scopus 로고
    • Heparin-coating of bypass circuits: Principles of heparin-coating techniques
    • Hsu LC: Heparin-coating of bypass circuits: Principles of heparin-coating techniques. Perfusion 6:209-219, 1991
    • (1991) Perfusion , vol.6 , pp. 209-219
    • Hsu, L.C.1
  • 48
    • 0008547006 scopus 로고
    • Duraflo II heparin immobilized cardiopulmonary bypass circuits
    • Ott RA et al (eds): Philadelphia, PA, Hanely & Belfus
    • Hsu LC: Duraflo II heparin immobilized cardiopulmonary bypass circuits, in Ott RA et al (eds): Cardiac Surgery: State of the Art Reviews. Philadelphia, PA, Hanely & Belfus, 1993, pp 265-276
    • (1993) Cardiac Surgery: State of the Art Reviews , pp. 265-276
    • Hsu, L.C.1
  • 50
    • 0028280959 scopus 로고
    • Heparin-coated cardiopulmonary bypass circuits
    • Gravlee GP: Heparin-coated cardiopulmonary bypass circuits. J Cardiothorac Vasc Anesthesia 8:213-222, 1994
    • (1994) J Cardiothorac Vasc Anesthesia , vol.8 , pp. 213-222
    • Gravlee, G.P.1
  • 51
    • 0029978340 scopus 로고    scopus 로고
    • The effects of Carmeda bioactive surface on human blood components during simulated extracorporeal circulation
    • Korn RL, Fisher CA, Livingston ER, et al: The effects of Carmeda bioactive surface on human blood components during simulated extracorporeal circulation. J Thorac Cardiovasc Surg 111:1073-1084, 1996
    • (1996) J Thorac Cardiovasc Surg , vol.111 , pp. 1073-1084
    • Korn, R.L.1    Fisher, C.A.2    Livingston, E.R.3
  • 52
    • 0026042558 scopus 로고
    • Clinical experience with heparin-coated cardiopulmonary bypass circuits
    • Pradhan MJ, Fleming JS, Nkere UU, et al: Clinical experience with heparin-coated cardiopulmonary bypass circuits. Perfusion 6:235-242, 1991
    • (1991) Perfusion , vol.6 , pp. 235-242
    • Pradhan, M.J.1    Fleming, J.S.2    Nkere, U.U.3
  • 53
    • 0029778984 scopus 로고    scopus 로고
    • Biocompatibility of heparin-coated extracorporeal circuits: A randomized, masked clinical trial
    • Muehrcke DD, McCarthy PM, Kottke-Marchant K, et al: Biocompatibility of heparin-coated extracorporeal circuits: A randomized, masked clinical trial. J Thorac Cardiovasc Surg 112:472-483, 1996
    • (1996) J Thorac Cardiovasc Surg , vol.112 , pp. 472-483
    • Muehrcke, D.D.1    McCarthy, P.M.2    Kottke-Marchant, K.3
  • 54
    • 9044236523 scopus 로고    scopus 로고
    • Surface-bound heparin fails to reduce thrombin formation during clinical cardiopulmonary bypass
    • Gorman RC, Ziats NP, Rao AK, et al: Surface-bound heparin fails to reduce thrombin formation during clinical cardiopulmonary bypass. J Thorac Cardiovasc Surg 111:1-12, 1996
    • (1996) J Thorac Cardiovasc Surg , vol.111 , pp. 1-12
    • Gorman, R.C.1    Ziats, N.P.2    Rao, A.K.3
  • 55
    • 0027429072 scopus 로고
    • Mechanisms of thrombin generation during surgery and cardiopulmonary bypass
    • Boisclair M, Lane DA, Philippou H, et al: Mechanisms of thrombin generation during surgery and cardiopulmonary bypass. Blood 82:3350-3357, 1993
    • (1993) Blood , vol.82 , pp. 3350-3357
    • Boisclair, M.1    Lane, D.A.2    Philippou, H.3
  • 56
    • 0029120179 scopus 로고
    • Completely heparinized cardiopulmonary bypass and reduced systemic heparin: Clinical and hemostatic effects
    • Ovrum E, Holen EA, Tangen G, et al: Completely heparinized cardiopulmonary bypass and reduced systemic heparin: Clinical and hemostatic effects. Ann Thorac Surg 60:365-371, 1995
    • (1995) Ann Thorac Surg , vol.60 , pp. 365-371
    • Ovrum, E.1    Holen, E.A.2    Tangen, G.3
  • 57
    • 0028812558 scopus 로고
    • Effects on coagulation and fibrinolysis with reduced versus full systemic heparinization and heparin-coated cardiopulmonary bypass
    • Ovrum E, Brosstad F, Holen EA, et al: Effects on coagulation and fibrinolysis with reduced versus full systemic heparinization and heparin-coated cardiopulmonary bypass. Circulation 92:2597-2584, 1995
    • (1995) Circulation , vol.92 , pp. 2597-12584
    • Ovrum, E.1    Brosstad, F.2    Holen, E.A.3
  • 58
    • 0027156091 scopus 로고
    • Heparin-coated circuits reduce the inflammatory response to cardiopulmonary bypass
    • Gu YJ, van Oeveren W, Akkerman C, et al: Heparin-coated circuits reduce the inflammatory response to cardiopulmonary bypass. Ann Thorac Surg 55:917-922, 1993
    • (1993) Ann Thorac Surg , vol.55 , pp. 917-922
    • Gu, Y.J.1    Van Oeveren, W.2    Akkerman, C.3
  • 59
    • 0029099911 scopus 로고
    • Reduced complement activation and improved postoperative performance after cardiopulmonary bypass with heparin-coated circuits
    • Jansen PGM, te Velthuis H, Huybregts RAJM, et al: Reduced complement activation and improved postoperative performance after cardiopulmonary bypass with heparin-coated circuits. J Thorac Cardiovasc Surg 110:829-834, 1995
    • (1995) J Thorac Cardiovasc Surg , vol.110 , pp. 829-834
    • Jansen, P.G.M.1    Te Velthuis, H.2    Huybregts, R.A.J.M.3
  • 60
    • 0030118055 scopus 로고    scopus 로고
    • Specific complement inhibition with heparin-coated extracorporeal circuits
    • te Velthuis H, Jansen PGM, Hack CE, et al: Specific complement inhibition with heparin-coated extracorporeal circuits. Ann Thorac Surg 61:1153-1157, 1996
    • (1996) Ann Thorac Surg , vol.61 , pp. 1153-1157
    • Te Velthuis, H.1    Jansen, P.G.M.2    Hack, C.E.3
  • 61
    • 0028856766 scopus 로고
    • Influence of Duraflo II heparin-treated extracorporeal circuits on the systemic inflammatory response in patients having coronary bypass
    • Weerwind PW, Maessen JG, van Tits LJH, et al: Influence of Duraflo II heparin-treated extracorporeal circuits on the systemic inflammatory response in patients having coronary bypass. J Thorac Cardiovasc Surg 110:1633-1641, 1995
    • (1995) J Thorac Cardiovasc Surg , vol.110 , pp. 1633-1641
    • Weerwind, P.W.1    Maessen, J.G.2    Van Tits, L.J.H.3
  • 62
    • 0029986314 scopus 로고    scopus 로고
    • Heparin-coated circuits reduce the formation of TNFa during cardiopulmonary bypass
    • Yamada H, Kudoh I, Hirose Y, et al: Heparin-coated circuits reduce the formation of TNFa during cardiopulmonary bypass. Acta Anaesthesiol Scand 40:311-317, 1996
    • (1996) Acta Anaesthesiol Scand , vol.40 , pp. 311-317
    • Yamada, H.1    Kudoh, I.2    Hirose, Y.3
  • 63
    • 0343723706 scopus 로고
    • Changed expression of adhesion molecules on granulocytes, monocytes and thrombocytes in heparin-coated cardiopulmonary bypass
    • San Diego, CA, Cardiothoracic Research and Education Foundation
    • Moen O, Hogasen K, Anderson C, et al: Changed expression of adhesion molecules on granulocytes, monocytes and thrombocytes in heparin-coated cardiopulmonary bypass. Abstract in Pathophysiology and Techniques of Cardiopulmonary Bypass. San Diego, CA, Cardiothoracic Research and Education Foundation, 1995, p 203
    • (1995) Abstract in Pathophysiology and Techniques of Cardiopulmonary Bypass , pp. 203
    • Moen, O.1    Hogasen, K.2    Anderson, C.3
  • 64
    • 0030039227 scopus 로고    scopus 로고
    • Beneficial effects of Duraflo II heparin-coated circuits on postperfusion lung dysfunction
    • Ranucci M, Cirri S, Conti D, et al: Beneficial effects of Duraflo II heparin-coated circuits on postperfusion lung dysfunction. Ann Thorac Surg 61:76-81, 1996
    • (1996) Ann Thorac Surg , vol.61 , pp. 76-81
    • Ranucci, M.1    Cirri, S.2    Conti, D.3
  • 65
    • 0029965853 scopus 로고    scopus 로고
    • Heparin-coated circuits and aprotinin prime for coronary artery bypass grafting
    • Jansen PGM, Baufreton C, LeBesnerais P, et al: Heparin-coated circuits and aprotinin prime for coronary artery bypass grafting. Ann Thorac Surg 61:1363-1366, 1996
    • (1996) Ann Thorac Surg , vol.61 , pp. 1363-1366
    • Jansen, P.G.M.1    Baufreton, C.2    LeBesnerais, P.3
  • 66
    • 0028142906 scopus 로고
    • Complement activation during cardiopulmonary bypass: Effects of immobilized heparin
    • Penka M, Hagman L, Halden E, et al: Complement activation during cardiopulmonary bypass: Effects of immobilized heparin. Ann Thorac Surg 58:421-424, 1994
    • (1994) Ann Thorac Surg , vol.58 , pp. 421-424
    • Penka, M.1    Hagman, L.2    Halden, E.3
  • 67
    • 0027932516 scopus 로고
    • Reduced complement and granulocyte activation with heparin-coated cardiopulmonary bypass
    • Fosses E, Moen O, Johnson E, et al: Reduced complement and granulocyte activation with heparin-coated cardiopulmonary bypass. Ann Thorac Surg 58:472-477, 1994
    • (1994) Ann Thorac Surg , vol.58 , pp. 472-477
    • Fosses, E.1    Moen, O.2    Johnson, E.3
  • 68
    • 0029978125 scopus 로고    scopus 로고
    • Eosinophil granulocyte activation and heparin-coated cardiopulmonary bypass
    • Ovrum E: Eosinophil granulocyte activation and heparin-coated cardiopulmonary bypass. Ann Thorac Surg 61:1038-1039, 1996
    • (1996) Ann Thorac Surg , vol.61 , pp. 1038-1039
    • Ovrum, E.1
  • 69
    • 0029555333 scopus 로고
    • High and low heparin dose with heparin-coated cardiopulmonary bypass: Activation of complement and granulocytes
    • Ovrum E, Mollnes TE, Fosse E, et al: High and low heparin dose with heparin-coated cardiopulmonary bypass: Activation of complement and granulocytes. Ann Thorac Surg 60:1755-1761, 1995
    • (1995) Ann Thorac Surg , vol.60 , pp. 1755-1761
    • Ovrum, E.1    Mollnes, T.E.2    Fosse, E.3
  • 70
    • 0027936510 scopus 로고
    • Risks and benefits of low systemic heparinization during open heart operations
    • von Segesser LK, Weiss BK, Pasic M, et al: Risks and benefits of low systemic heparinization during open heart operations. Ann Thorac Surg 58:391-398, 1994
    • (1994) Ann Thorac Surg , vol.58 , pp. 391-398
    • Von Segesser, L.K.1    Weiss, B.K.2    Pasic, M.3
  • 71
    • 0029980620 scopus 로고    scopus 로고
    • Effective use of heparin-bonded circuits and lower anticoagulation for coronary artery bypass grafting in Jehovah's witnesses
    • Aldea GS, Shapira OM, Treanor PR, et al: Effective use of heparin-bonded circuits and lower anticoagulation for coronary artery bypass grafting in Jehovah's witnesses. J Card Surg 11:12-17, 1996
    • (1996) J Card Surg , vol.11 , pp. 12-17
    • Aldea, G.S.1    Shapira, O.M.2    Treanor, P.R.3
  • 72
    • 0030217969 scopus 로고    scopus 로고
    • Heparin-bonded circuits with a reduced anticoagulation protocol in primary CABG: A prospective, randomized study
    • Aldea GS, Doursounian M, O'Gara P, et al: Heparin-bonded circuits with a reduced anticoagulation protocol in primary CABG: A prospective, randomized study. Ann Thorac Surg 62:410-418, 1996
    • (1996) Ann Thorac Surg , vol.62 , pp. 410-418
    • Aldea, G.S.1    Doursounian, M.2    O'Gara, P.3
  • 73
    • 0020955483 scopus 로고
    • Polyethylene oxide as a biomaterial
    • Merrill E, Salzman EW: Polyethylene oxide as a biomaterial. ASAIO J 6:60-64, 1983
    • (1983) ASAIO J , vol.6 , pp. 60-64
    • Merrill, E.1    Salzman, E.W.2
  • 74
    • 0024597953 scopus 로고
    • Effect of albumin coating on the in vitro blood compatibility of Dacron arterial prostheses
    • Kottke-Marchant K, Anderson JM, Umemura Y, et al: Effect of albumin coating on the in vitro blood compatibility of Dacron arterial prostheses. Biomaterials 10:147-155, 1989
    • (1989) Biomaterials , vol.10 , pp. 147-155
    • Kottke-Marchant, K.1    Anderson, J.M.2    Umemura, Y.3
  • 75
    • 0025257339 scopus 로고
    • Reduction of complement activation during bypass by prime manipulation
    • Bonser RS, Dave JR, Davies ET, et al: Reduction of complement activation during bypass by prime manipulation. Ann Thorac Surg 49:279-283, 1990
    • (1990) Ann Thorac Surg , vol.49 , pp. 279-283
    • Bonser, R.S.1    Dave, J.R.2    Davies, E.T.3
  • 76
    • 0024430633 scopus 로고
    • Does the addition of albumin to the prime solution in cardiopulmonary bypass affect clinical outcome? A prospective randomized study
    • Marelli D, Paul A, Samson R, et al: Does the addition of albumin to the prime solution in cardiopulmonary bypass affect clinical outcome? A prospective randomized study. J Thorac Cardiovasc Surg 98:751-756, 1989
    • (1989) J Thorac Cardiovasc Surg , vol.98 , pp. 751-756
    • Marelli, D.1    Paul, A.2    Samson, R.3
  • 77
    • 0026582343 scopus 로고
    • Improvement of blood compatibility on cellulose dialysis membrane
    • Ishihara K, Takayama R, Nakabayashi N, et al: Improvement of blood compatibility on cellulose dialysis membrane. Biomaterials 13:235-239, 1992
    • (1992) Biomaterials , vol.13 , pp. 235-239
    • Ishihara, K.1    Takayama, R.2    Nakabayashi, N.3
  • 78
    • 0021130739 scopus 로고
    • Endothelial seeding of Dacron and polytetrafluoroethylene grafts: The cellular events of healing
    • Herring MB, Baughman S, Glover J, et al: Endothelial seeding of Dacron and polytetrafluoroethylene grafts: The cellular events of healing. Surgery 96:745-754, 1984
    • (1984) Surgery , vol.96 , pp. 745-754
    • Herring, M.B.1    Baughman, S.2    Glover, J.3
  • 79
    • 0000576204 scopus 로고    scopus 로고
    • Low thromboembolic risk without anticoagulation using advanced-design left ventricular assist devices
    • Slater JP, Rose E, Levin HR, et al: Low thromboembolic risk without anticoagulation using advanced-design left ventricular assist devices. Ann Thorac Surg 62:1321-1328, 1996
    • (1996) Ann Thorac Surg , vol.62 , pp. 1321-1328
    • Slater, J.P.1    Rose, E.2    Levin, H.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.