메뉴 건너뛰기




Volumn 2, Issue 5, 2010, Pages 145-152

MU-Tomo: Independent dose validation software for helical tomotherapy

Author keywords

Dose verification; Independent dose calculation; Second check; TomoTherapy

Indexed keywords

ALGORITHM; ARTICLE; COLLIMATOR; COMPUTER PROGRAM; DOSIMETRY; INTENSITY MODULATED RADIATION THERAPY; MONTE CARLO METHOD; PHANTOM; QUALITY CONTROL; TOMOTHERAPY; TREATMENT PLANNING;

EID: 77957933150     PISSN: None     EISSN: 19485956     Source Type: Journal    
DOI: 10.4172/1948-5956.1000040     Document Type: Article
Times cited : (14)

References (31)
  • 2
    • 0037496219 scopus 로고    scopus 로고
    • Independent calculations to validate monitor units from ADAC treatment planning system
    • Ayyangar KM, Saw CB, Gearheart D, Shen B, Thompson R (2003) Independent calculations to validate monitor units from ADAC treatment planning system. Med Dosim 28: 79-83.
    • (2003) Med Dosim , vol.28 , pp. 79-83
    • Ayyangar, K.M.1    Saw, C.B.2    Gearheart, D.3    Shen, B.4    Thompson, R.5
  • 4
    • 2342583374 scopus 로고    scopus 로고
    • Is tomotherapy the future of IMRT?
    • Beavis AW (2004) Is tomotherapy the future of IMRT? Br J Radiol 77: 285-295.
    • (2004) Br J Radiol , vol.77 , pp. 285-295
    • Beavis, A.W.1
  • 5
    • 7244243829 scopus 로고    scopus 로고
    • Analgorithm for independent verification of Gamma Knife (TM) treatment plans
    • Beck J, Berndt A (2004) Analgorithm for independent verification of Gamma Knife (TM) treatment plans. Med Phys 31: 2780-2784.
    • (2004) Med Phys , vol.31 , pp. 2780-2784
    • Beck, J.1    Berndt, A.2
  • 6
    • 28644439201 scopus 로고    scopus 로고
    • A dose verification method using a monitor unit matrix for dynamic IMRT on Varian linear accelerators
    • Chen XG, Yue NJ, Chen WM, Saw CB, Heron DE, et al. (2005) A dose verification method using a monitor unit matrix for dynamic IMRT on Varian linear accelerators. Phys Med Biol 50: 5641-5652.
    • (2005) Phys Med Biol , vol.50 , pp. 5641-5652
    • Chen, X.G.1    Yue, N.J.2    Chen, W.M.3    Saw, C.B.4    Heron, D.E.5
  • 7
    • 0036735839 scopus 로고    scopus 로고
    • Independent monitor unit calculation for intensity modulated radiotherapy using the MIMIC multileaf collimator
    • Chen Z, Xing L, Nath R (2002) Independent monitor unit calculation for intensity modulated radiotherapy using the MIMIC multileaf collimator. Med Phys 29: 2041-2051.
    • (2002) Med Phys , vol.29 , pp. 2041-2051
    • Chen, Z.1    Xing, L.2    Nath, R.3
  • 8
    • 68849122593 scopus 로고    scopus 로고
    • Evaluation of a commercial VMC++ Monte Carlo based treatment planning system for electron beams using EGSnrc/BEAMnrc simulations and measurements
    • Edimo P, Clermont C, Kwato MG, Vynckier S (2009) Evaluation of a commercial VMC++ Monte Carlo based treatment planning system for electron beams using EGSnrc/BEAMnrc simulations and measurements. Phys Medica 25: 111-121.
    • (2009) Phys Medica , vol.25 , pp. 111-121
    • Edimo, P.1    Clermont, C.2    Kwato, M.G.3    Vynckier, S.4
  • 10
    • 34547729279 scopus 로고    scopus 로고
    • Patient specific IMRT verification using independent fluence-based dose calculation software: Experimental benchmarking and initial clinical experience
    • Georg D, Stock M, Kroupa B, Olofsson J, Nyholm T, et al. (2007) Patient specific IMRT verification using independent fluence-based dose calculation software: experimental benchmarking and initial clinical experience. Phys Med Biol 52: 4981-4992.
    • (2007) Phys Med Biol , vol.52 , pp. 4981-4992
    • Georg, D.1    Stock, M.2    Kroupa, B.3    Olofsson, J.4    Nyholm, T.5
  • 11
    • 70049105106 scopus 로고    scopus 로고
    • Independent calculation of dose from a helical TomoTherapy unit
    • Gibbons JP, Smith K, Cheek D, Rosen I (2009) Independent calculation of dose from a helical TomoTherapy unit. J Appl Clin Med Phys 10: 2772.
    • (2009) J Appl Clin Med Phys , vol.10 , pp. 2772
    • Gibbons, J.P.1    Smith, K.2    Cheek, D.3    Rosen, I.4
  • 12
    • 77957962430 scopus 로고    scopus 로고
    • Independent 3D dose calculation as part of an overall individualized dosimetric QA protocol for IMRT
    • Jansen WPA, Dirkx MLP, Heijmen BJM (2003) Independent 3D dose calculation as part of an overall individualized dosimetric QA protocol for IMRT. Radiother Oncol 68: S36-S36.
    • (2003) Radiother Oncol , vol.68
    • Jansen, W.P.A.1    Dirkx, M.L.P.2    Heijmen, B.J.M.3
  • 13
    • 77957938465 scopus 로고    scopus 로고
    • The Physics of Radiation Therapy
    • Khan FM, Stathakis S, (2010) The Physics of Radiation Therapy. Med Phys 37: 1374.
    • (2010) Med Phys , vol.37 , pp. 1374
    • Khan, F.M.1    Stathakis, S.2
  • 14
    • 67649414960 scopus 로고    scopus 로고
    • Development of a new multi-modal Monte-Carlo radiotherapy planning system
    • Kumada H, Nakamura T, Komeda M, Matsumura A (2009) Development of a new multi-modal Monte-Carlo radiotherapy planning system. Appl Radiat Isot 67: S118-S121.
    • (2009) Appl Radiat Isot , vol.67
    • Kumada, H.1    Nakamura, T.2    Komeda, M.3    Matsumura, A.4
  • 16
    • 0028230872 scopus 로고
    • Comprehensive QA for radiation oncology: Report of aapm radiation-therapy committee task group 40
    • Kutcher GJ, Coia L, Gillin M, Hanson WF, Leibel S, et al. (1994) Comprehensive QA for radiation oncology: report of aapm radiation-therapy committee task group 40. Med Phys 21: 581-618.
    • (1994) Med Phys , vol.21 , pp. 581-618
    • Kutcher, G.J.1    Coia, L.2    Gillin, M.3    Hanson, W.F.4    Leibel, S.5
  • 17
    • 34247598484 scopus 로고    scopus 로고
    • An independent dose calculation algorithm for MLC-based stereotactic radiotherapy
    • Lorenz F, Killoran JH, Wenz F, Zygmanski P (2007) An independent dose calculation algorithm for MLC-based stereotactic radiotherapy. Med Phys 34: 1605-1614.
    • (2007) Med Phys , vol.34 , pp. 1605-1614
    • Lorenz, F.1    Killoran, J.H.2    Wenz, F.3    Zygmanski, P.4
  • 18
    • 41849145210 scopus 로고    scopus 로고
    • An independent dose calculation algorithm for MLC-based radiotherapy including the spatial dependence of MLC transmission
    • Lorenz F, Nalichowski A, Rosca F, Killoran J, Wenz F, et al. (2008) An independent dose calculation algorithm for MLC-based radiotherapy including the spatial dependence of MLC transmission. Phys Med Biol 53: 557-573.
    • (2008) Phys Med Biol , vol.53 , pp. 557-573
    • Lorenz, F.1    Nalichowski, A.2    Rosca, F.3    Killoran, J.4    Wenz, F.5
  • 19
    • 33745664018 scopus 로고    scopus 로고
    • Monte Carlo based IMRT dose verification using MLC log fi les and R/V outputs
    • Luo W, Li J, Price RA, Chen L, Yang J, et al. (2006) Monte Carlo based IMRT dose verification using MLC log fi les and R/V outputs. Med Phys 33: 2557-2564.
    • (2006) Med Phys , vol.33 , pp. 2557-2564
    • Luo, W.1    Li, J.2    Price, R.A.3    Chen, L.4    Yang, J.5
  • 20
    • 33745495381 scopus 로고    scopus 로고
    • History of tomotherapy
    • Mackie TR (2006) History of tomotherapy. Phys Med Biol 51: R427-R453.
    • (2006) Phys Med Biol , vol.51
    • Mackie, T.R.1
  • 21
    • 0027141318 scopus 로고
    • Tomotherapy - a new concept for the delivery of dynamic conformal radiotherapy
    • Mackie TR, Holmes T, Swerdloff S, Reckwerdt P, Deasy JO, et al. (1993) Tomotherapy - a new concept for the delivery of dynamic conformal radiotherapy. Med Phys 20: 1709-1719.
    • (1993) Med Phys , vol.20 , pp. 1709-1719
    • Mackie, T.R.1    Holmes, T.2    Swerdloff, S.3    Reckwerdt, P.4    Deasy, J.O.5
  • 23
    • 69549122374 scopus 로고    scopus 로고
    • A preliminary study of in-house monte carlo simulations: An integrated montecarlo verification system
    • Mukumoto N, Tsujii K, Saito S, Yasunaga M, Takegawa H, et al. (2009) A preliminary study of in-house monte carlo simulations: an integrated montecarlo verification system. Int J Radiat Oncol Biol Phys 75: 571-579.
    • (2009) Int J Radiat Oncol Biol Phys , vol.75 , pp. 571-579
    • Mukumoto, N.1    Tsujii, K.2    Saito, S.3    Yasunaga, M.4    Takegawa, H.5
  • 24
    • 70249137312 scopus 로고    scopus 로고
    • A Monte Carlo-based procedure for independent monitor unit calculation in IMRT treatment plans
    • Pisaturo O, Moeckli R, Mirimanoff RO, Bochud FO (2009) A Monte Carlo-based procedure for independent monitor unit calculation in IMRT treatment plans. Phys Med Biol 54: 4299-4310.
    • (2009) Phys Med Biol , vol.54 , pp. 4299-4310
    • Pisaturo, O.1    Moeckli, R.2    Mirimanoff, R.O.3    Bochud, F.O.4
  • 25
    • 53549125817 scopus 로고    scopus 로고
    • A Monte Carlo model for independent dose verification in serial tomotherapy
    • Sarkar V, Stathakis S, Papanikolaou N (2008) A Monte Carlo model for independent dose verification in serial tomotherapy. Technol Cancer Res Treat 7: 385-392.
    • (2008) Technol Cancer Res Treat , vol.7 , pp. 385-392
    • Sarkar, V.1    Stathakis, S.2    Papanikolaou, N.3
  • 26
    • 85024936775 scopus 로고    scopus 로고
    • Quasi-independent monitor unit calculation for intensity modulated sequential tomotherapy
    • Tsai JS, Engler MJ, Liu J (2002) Quasi-independent monitor unit calculation for intensity modulated sequential tomotherapy. J Appl Clin Med Phys 3: 135-153.
    • (2002) J Appl Clin Med Phys , vol.3 , pp. 135-153
    • Tsai, J.S.1    Engler, M.J.2    Liu, J.3
  • 27
    • 21144451652 scopus 로고    scopus 로고
    • Fast radiographic fi lm calibration procedure for helical tomotherapy intensity modulated radiation therapy dose verification
    • Yan YL, Papanikolaou N, Weng XJ, Penagaricano J, Ratanatharathorn V (2005) Fast radiographic fi lm calibration procedure for helical tomotherapy intensity modulated radiation therapy dose verification. Med Phys 32: 1566-1570.
    • (2005) Med Phys , vol.32 , pp. 1566-1570
    • Yan, Y.L.1    Papanikolaou, N.2    Weng, X.J.3    Penagaricano, J.4    Ratanatharathorn, V.5
  • 29
    • 0344393794 scopus 로고    scopus 로고
    • Independent dosimetric calculation with inclusion of head scatter and MLC transmission for IMRT
    • Yang Y, Xing L, Li JG, Palta J, Chen Y, et al. (2003) Independent dosimetric calculation with inclusion of head scatter and MLC transmission for IMRT. Med Phys 30: 2937-2947.
    • (2003) Med Phys , vol.30 , pp. 2937-2947
    • Yang, Y.1    Xing, L.2    Li, J.G.3    Palta, J.4    Chen, Y.5
  • 30
    • 33748637352 scopus 로고    scopus 로고
    • Radiation shielding design of a new tomotherapy facility
    • Zacarias A, Balog J, Mills M (2006) Radiation shielding design of a new tomotherapy facility. Health Phys 91: 289-295.
    • (2006) Health Phys , vol.91 , pp. 289-295
    • Zacarias, A.1    Balog, J.2    Mills, M.3
  • 31
    • 0041888173 scopus 로고    scopus 로고
    • Point dose verification for intensity modulated radiosurgery using Clarkson's method
    • Zhu J, Yin FF, Kim JH (2003) Point dose verification for intensity modulated radiosurgery using Clarkson's method. Med Phys 30: 2218-2221.
    • (2003) Med Phys , vol.30 , pp. 2218-2221
    • Zhu, J.1    Yin, F.F.2    Kim, J.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.