메뉴 건너뛰기




Volumn 54, Issue 13, 2009, Pages 4299-4310

A Monte Carlo-based procedure for independent monitor unit calculation in IMRT treatment plans

Author keywords

[No Author keywords available]

Indexed keywords

ABSORBED DOSE; BEAMLETS; DOSE DISTRIBUTIONS; FURTHER DEVELOPMENT; INTENSITY-MODULATED RADIOTHERAPY; LEAST SQUARES FIT; LINEAR MATRIX EQUATIONS; MEASURED DATA; MONITOR UNIT CALCULATIONS; MONITOR UNITS; MONTE CARLO; MONTE CARLO CODES; OPTIMIZATION ALGORITHMS; STEP-AND-SHOOT; TOMOTHERAPY; TREATMENT PLANNING SYSTEMS; TREATMENT PLANS; VOLUMETRIC MODULATED ARC THERAPY;

EID: 70249137312     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/54/13/022     Document Type: Article
Times cited : (22)

References (38)
  • 1
    • 0025730909 scopus 로고
    • Monte Carlo techniques in medical radiation physics
    • Andreo P 1991 Monte Carlo techniques in medical radiation physics Phys. Med. Biol. 36 861-920
    • (1991) Phys. Med. Biol. , vol.36 , Issue.7 , pp. 861-920
    • Andreo, P.1
  • 2
    • 38349000693 scopus 로고    scopus 로고
    • Tissue segmentation in Monte Carlo treatment planning: A simulation study using dual-energy CT images
    • Bazalova M, Carrier J F, Beaulieu L and Verhaegen F 2008 Tissue segmentation in Monte Carlo treatment planning: a simulation study using dual-energy CT images Radiother. Oncol. 86 93-8
    • (2008) Radiother. Oncol. , vol.86 , Issue.1 , pp. 93-98
    • Bazalova, M.1    Carrier, J.F.2    Beaulieu, L.3    Verhaegen, F.4
  • 3
    • 0025103658 scopus 로고
    • Methods of image reconstruction from projections applied to conformation radiotherapy
    • Bortfeld T, Burkelbach J, Boesecke R and Schlegel W 1990 Methods of image reconstruction from projections applied to conformation radiotherapy Phys. Med. Biol. 35 1423-34
    • (1990) Phys. Med. Biol. , vol.35 , Issue.10 , pp. 1423-1434
    • Bortfeld, T.1    Burkelbach, J.2    Boesecke, R.3    Schlegel, W.4
  • 4
    • 36649020653 scopus 로고    scopus 로고
    • Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning
    • Chetty I J et al 2007 Report of the AAPM Task Group No. 105: issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning Med. Phys. 34 4818-53
    • (2007) Med. Phys. , vol.34 , Issue.12 , pp. 4818-4853
    • Chetty, I.J.1
  • 5
    • 33748939057 scopus 로고    scopus 로고
    • Clinical comparison of head and neck and prostate IMRT plans using absorbed dose to medium and absorbed dose to water
    • Dogan N, Siebers J V and Keall P J 2006 Clinical comparison of head and neck and prostate IMRT plans using absorbed dose to medium and absorbed dose to water Phys. Med. Biol. 51 4967-80
    • (2006) Phys. Med. Biol. , vol.51 , Issue.19 , pp. 4967-4980
    • Dogan, N.1    Siebers, J.V.2    Keall, P.J.3
  • 6
    • 0031841922 scopus 로고    scopus 로고
    • The indirect use of CT numbers to establish material properties needed for Monte Carlo calculation of dose distributions in patients
    • du Plessis F C, Willemse C A, Lotter M G and Goedhals L 1998 The indirect use of CT numbers to establish material properties needed for Monte Carlo calculation of dose distributions in patients Med. Phys. 25 1195-201
    • (1998) Med. Phys. , vol.25 , Issue.7 , pp. 1195-1201
    • Du Plessis, F.C.1    Willemse, C.A.2    Lotter, M.G.3    Goedhals, L.4
  • 7
    • 0033866920 scopus 로고    scopus 로고
    • Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM
    • Francescon P, Cavedon C, Reccanello S and Cora S 2000 Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM Med. Phys. 27 1579-87
    • (2000) Med. Phys. , vol.27 , Issue.7 , pp. 1579-1587
    • Francescon, P.1    Cavedon, C.2    Reccanello, S.3    Cora, S.4
  • 8
    • 0037320058 scopus 로고    scopus 로고
    • Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code
    • Francescon P, Cora S and Chiovati P 2003 Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code Med. Phys. 30 144-57
    • (2003) Med. Phys. , vol.30 , Issue.2 , pp. 144-157
    • Francescon, P.1    Cora, S.2    Chiovati, P.3
  • 9
    • 7844245059 scopus 로고    scopus 로고
    • A software tool for the quantitative evaluation of 3D dose calculation algorithms
    • Harms W B Sr, Low D A, Wong J W and Purdy J A 1998 A software tool for the quantitative evaluation of 3D dose calculation algorithms Med. Phys. 25 1830-6
    • (1998) Med. Phys. , vol.25 , Issue.10 , pp. 1830-1836
    • Harms Sr, W.B.1    Low, D.A.2    Wong, J.W.3    Purdy, J.A.4
  • 10
    • 34147152661 scopus 로고    scopus 로고
    • Patient-specific dosimetry of conventional and intensity modulated radiation therapy using a novel full Monte Carlo phase space reconstruction method from electronic portal images
    • Jarry G and Verhaegen F 2007 Patient-specific dosimetry of conventional and intensity modulated radiation therapy using a novel full Monte Carlo phase space reconstruction method from electronic portal images Phys. Med. Biol. 52 2277-99
    • (2007) Phys. Med. Biol. , vol.52 , Issue.8 , pp. 2277-2299
    • Jarry, G.1    Verhaegen, F.2
  • 11
    • 33746608072 scopus 로고    scopus 로고
    • Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrc
    • Kawrakow I and Walters B R 2006 Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrc Med. Phys. 33 3046-56
    • (2006) Med. Phys. , vol.33 , Issue.8 , pp. 3046-3056
    • Kawrakow, I.1    Walters, B.R.2
  • 12
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • DOI 10.1118/1.598917
    • Kawrakow I 2000 Accurate condensed history Monte Carlo simulation of electron transport: I. EGSnrc, the new EGS4 version Med. Phys. 27 485-98 (Pubitemid 30171797)
    • (2000) Medical Physics , vol.27 , Issue.3 , pp. 485-498
    • Kawrakow, I.1
  • 13
    • 0029877277 scopus 로고    scopus 로고
    • 3D electron dose calculation using a voxel based Monte Carlo algorithm (VMC)
    • Kawrakow I, Fippel M and Friedrich K 1996 3D electron dose calculation using a voxel based Monte Carlo algorithm (VMC) Med. Phys. 23 445-57
    • (1996) Med. Phys. , vol.23 , Issue.4 , pp. 445-457
    • Kawrakow, I.1    Fippel, M.2    Friedrich, K.3
  • 14
    • 7244223252 scopus 로고    scopus 로고
    • Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting
    • Kawrakow I, Rogers D W and Walters B R 2004 Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting Med. Phys. 31 2883-98
    • (2004) Med. Phys. , vol.31 , Issue.10 , pp. 2883-2898
    • Kawrakow, I.1    Rogers, D.W.2    Walters, B.R.3
  • 15
    • 0036581934 scopus 로고    scopus 로고
    • Dm rather than Dw should be used in Monte Carlo treatment planning. Against the proposition
    • Keall P 2002 Dm rather than Dw should be used in Monte Carlo treatment planning. Against the proposition Med. Phys. 29 923-4
    • (2002) Med. Phys. , vol.29 , pp. 923-924
    • Keall, P.1
  • 16
    • 0033744151 scopus 로고    scopus 로고
    • A monitor unit verification calculation in intensity modulated radiotherapy as a dosimetry quality assurance
    • Kung J H, Chen G T and Kuchnir F K 2000 A monitor unit verification calculation in intensity modulated radiotherapy as a dosimetry quality assurance Med. Phys. 27 2226-30
    • (2000) Med. Phys. , vol.27 , Issue.10 , pp. 2226-2230
    • Kung, J.H.1    Chen, G.T.2    Kuchnir, F.K.3
  • 18
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • Low D A, Harms W B, Mutic S and Purdy J A 1998 A technique for the quantitative evaluation of dose distributions Med. Phys. 25 656-61
    • (1998) Med. Phys. , vol.25 , Issue.5 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 22
    • 0000763883 scopus 로고
    • Applications of the Monte Carlo method in radiotherapy
    • Mackie T R 1990 Applications of the Monte Carlo method in radiotherapy The Dosimetry of Ionizing Radiation vol 3 ed K R Kase, B E Bjarngard and F H Attix (New York: Academic) pp 541-620
    • (1990) The Dosimetry of Ionizing Radiation , vol.3 , pp. 541-620
    • MacKie, T.R.1
  • 28
    • 0033983759 scopus 로고    scopus 로고
    • Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions
    • Schneider W, Bortfeld T and Schlegel W 2000 Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions Phys. Med. Biol. 45 459-78
    • (2000) Phys. Med. Biol. , vol.45 , Issue.2 , pp. 459-478
    • Schneider, W.1    Bortfeld, T.2    Schlegel, W.3
  • 29
    • 0034036210 scopus 로고    scopus 로고
    • Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations
    • Siebers J V, Keall P J, Nahum A E and Mohan R 2000 Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations Phys. Med. Biol. 45 983-95
    • (2000) Phys. Med. Biol. , vol.45 , Issue.4 , pp. 983-995
    • Siebers, J.V.1    Keall, P.J.2    Nahum, A.E.3    Mohan, R.4
  • 30
    • 56349160061 scopus 로고    scopus 로고
    • An overview of Monte Carlo treatment planning for radiotherapy
    • Spezi E and Lewis G 2008 An overview of Monte Carlo treatment planning for radiotherapy Radiat. Prot Dosim. 131 123-9
    • (2008) Radiat. Prot Dosim. , vol.131 , Issue.1 , pp. 123-129
    • Spezi, E.1    Lewis, G.2
  • 31
    • 0037038880 scopus 로고    scopus 로고
    • A DICOM-RT-based toolbox for the evaluation and verification of radiotherapy plans
    • Spezi E, Lewis D G and Smith C W 2002 A DICOM-RT-based toolbox for the evaluation and verification of radiotherapy plans Phys. Med. Biol. 47 4223-32
    • (2002) Phys. Med. Biol. , vol.47 , Issue.23 , pp. 4223-4232
    • Spezi, E.1    Lewis, D.G.2    Smith, C.W.3
  • 32
    • 0000724440 scopus 로고
    • On the numerical solution of constrained least-squares problems
    • Stoer J 1971 On the numerical solution of constrained least-squares problems J. Numer. Anal. 8 382-411
    • (1971) J. Numer. Anal. , vol.8 , Issue.2 , pp. 382-411
    • Stoer, J.1
  • 33
    • 34047250299 scopus 로고    scopus 로고
    • Conversion of CT numbers into tissue parameters for Monte Carlo dose calculations: A multi-centre study
    • Vanderstraeten B et al 2007 Conversion of CT numbers into tissue parameters for Monte Carlo dose calculations: a multi-centre study Phys. Med. Biol. 52 539-62
    • (2007) Phys. Med. Biol. , vol.52 , Issue.3 , pp. 539-562
    • Vanderstraeten, B.1
  • 35
    • 0034063644 scopus 로고    scopus 로고
    • Monitor unit calculation for an intensity modulated photon field by a simple scatter-summation algorithm
    • Xing L, Chen Y, Luxton G, Li J G and Boyer A L 2000 Monitor unit calculation for an intensity modulated photon field by a simple scatter-summation algorithm Phys. Med. Biol. 45 N1-7
    • (2000) Phys. Med. Biol. , vol.45 , Issue.3
    • Xing, L.1    Chen, Y.2    Luxton, G.3    Li, J.G.4    Boyer, A.L.5
  • 37
    • 16444367288 scopus 로고    scopus 로고
    • Dosimetric verification of IMRT treatment planning using Monte Carlo simulations for prostate cancer
    • Yang J, Li J, Chen L, Price R, McNeeley S, Qin L, Wang L, Xiong W and Ma C M 2005 Dosimetric verification of IMRT treatment planning using Monte Carlo simulations for prostate cancer Phys. Med. Biol. 50 869-78
    • (2005) Phys. Med. Biol. , vol.50 , Issue.5 , pp. 869-878
    • Yang, J.1    Li, J.2    Chen, L.3    Price, R.4    McNeeley, S.5    Qin, L.6    Wang, L.7    Xiong, W.8    Ma, C.M.9
  • 38
    • 0344393794 scopus 로고    scopus 로고
    • Independent dosimetric calculation with inclusion of head scatter and MLC transmission for IMRT
    • Yang Y, Xing L, Li J G, Palta J, Chen Y, Luxton G and Boyer A 2003 Independent dosimetric calculation with inclusion of head scatter and MLC transmission for IMRT Med. Phys. 30 2937-47
    • (2003) Med. Phys. , vol.30 , Issue.11 , pp. 2937-2947
    • Yang, Y.1    Xing, L.2    Li, J.G.3    Palta, J.4    Chen, Y.5    Luxton, G.6    Boyer, A.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.