메뉴 건너뛰기




Volumn 20, Issue 8, 2010, Pages

MEMS-based Coulter counter for cell counting and sizing using multiple electrodes

Author keywords

[No Author keywords available]

Indexed keywords

CELL COUNTING; COULTER COUNTERS; DIELECTROPHORETIC FORCES; DYED FLUID; ENHANCED SENSITIVITY; EXTRACELLULAR; EXTRACELLULAR ENVIRONMENTS; FIBROBLAST CELLS; FUNCTION OF TIME; MICROBEADS; MULTIPLE ELECTRODES; PASSIVE MIXING; PHOSPHATE-BUFFERED SALINES; TESTING TIME; VERTICAL ELECTRODES;

EID: 77957802828     PISSN: 09601317     EISSN: 13616439     Source Type: Journal    
DOI: 10.1088/0960-1317/20/8/085035     Document Type: Article
Times cited : (13)

References (39)
  • 2
    • 77957155336 scopus 로고
    • Rapid whole-blood platelet counting using an electronic particle counter
    • Eastham R D 1963 Rapid whole-blood platelet counting using an electronic particle counter J. Clin. Pathol. 16 168-9
    • (1963) J. Clin. Pathol. , vol.16 , pp. 168-169
    • Eastham, R.D.1
  • 3
    • 0017275557 scopus 로고
    • Measurement of the mean cell volume using electronic particle counters
    • England J M and Down M C 1975 Measurement of the mean cell volume using electronic particle counters Br. J. Haematol. 32 403-10
    • (1975) Br. J. Haematol. , vol.32 , pp. 403-410
    • England, J.M.1    Down, M.C.2
  • 5
    • 0017395979 scopus 로고
    • Membrane permeability equations and their solutions for red cells
    • Milgram J H and Solomon A K 1977 Membrane permeability equations and their solutions for red cells J. Membr. Biol. 34 103-44
    • (1977) J. Membr. Biol. , vol.34 , pp. 103-144
    • Milgram, J.H.1    Solomon, A.K.2
  • 8
    • 0035669486 scopus 로고    scopus 로고
    • Quantitative sensing of nanoscale colloids using a microchip Coulter counter
    • Saleh O and Sohn L 2001 Quantitative sensing of nanoscale colloids using a microchip Coulter counter Rev. Sci. Instrum. 72 4449
    • (2001) Rev. Sci. Instrum. , vol.72 , pp. 4449
    • Saleh, O.1    Sohn, L.2
  • 9
    • 34249111139 scopus 로고    scopus 로고
    • A micromachined high throughput Coulter counter for bioparticle detection and counting
    • Zhe J, Jagtiani A, Dutta P, Jun H and Carletta J 2007 A micromachined high throughput Coulter counter for bioparticle detection and counting J. Micromech. Microeng. 17 304
    • (2007) J. Micromech. Microeng. , vol.17 , pp. 304
    • Zhe, J.1    Jagtiani, A.2    Dutta, P.3    Jun, H.4    Carletta, J.5
  • 10
    • 0033101199 scopus 로고    scopus 로고
    • Electric impedance spectroscopy using microchannels with integrated metal electrodes
    • Ayliffe H E, Frazier A B and Rabbitt R D 1999 Electric impedance spectroscopy using microchannels with integrated metal electrodes J. Microelectromech. Syst. 8 50-7
    • (1999) J. Microelectromech. Syst. , vol.8 , pp. 50-57
    • Ayliffe, H.E.1    Frazier, A.B.2    Rabbitt, R.D.3
  • 12
    • 33745482598 scopus 로고    scopus 로고
    • Detection and counting of micro-scale particles and pollen using a multi-aperture Coulter counter Meas
    • Jagtiani A V, Zhe J, Hu J and Carletta J 2006 Detection and counting of micro-scale particles and pollen using a multi-aperture Coulter counterMeas. Sci. Tech. 17 1706-14
    • (2006) . Sci. Tech. , vol.17 , pp. 1706-1714
    • Jagtiani, A.V.1    Zhe, J.2    Hu, J.3    Carletta, J.4
  • 13
    • 36049002217 scopus 로고    scopus 로고
    • Microfabricated high-throughput electronic particle detector
    • Wood D K, Requa M V and Cleland A N 2007 Microfabricated high-throughput electronic particle detector Rev. Sci. Instrum. 78 104301
    • (2007) Rev. Sci. Instrum. , vol.78 , pp. 104301
    • Wood, D.K.1    Requa, M.V.2    Cleland, A.N.3
  • 16
    • 1642452594 scopus 로고    scopus 로고
    • Hard and soft micromachining for BioMEMS: Review of techniques and examples of applications in microfluidics and drug delivery
    • Ziaie B, Baldi A, Lei M, Gu Y and Siegel R A 2004 Hard and soft micromachining for BioMEMS: review of techniques and examples of applications in microfluidics and drug delivery Adv. Drug Deliv. Rev. 56 145-72
    • (2004) Adv. Drug Deliv. Rev. , vol.56 , pp. 145-172
    • Ziaie, B.1    Baldi, A.2    Lei, M.3    Gu, Y.4    Siegel, R.A.5
  • 17
    • 54549103215 scopus 로고    scopus 로고
    • An optimal three-dimensional focusing technique for micro-flow cytometers
    • Tsai C, Hou H and Fu L 2008 An optimal three-dimensional focusing technique for micro-flow cytometers Microfluid Nanofluid 5 827-36
    • (2008) Microfluid Nanofluid , vol.5 , pp. 827-836
    • Tsai, C.1    Hou, H.2    Fu, L.3
  • 19
    • 33744493954 scopus 로고    scopus 로고
    • The hydrodynamic focusing effect inside rectangular microchannels
    • Lee G, Chang C, Huang S and Yang R 2006 The hydrodynamic focusing effect inside rectangular microchannels J. Micromech. Microeng. 16 1024-32
    • (2006) J. Micromech. Microeng. , vol.16 , pp. 1024-1032
    • Lee, G.1    Chang, C.2    Huang, S.3    Yang, R.4
  • 20
    • 0141989814 scopus 로고    scopus 로고
    • Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing
    • Gawad S, Schild L and Renaud P 2001 Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing Lab Chip 1 76-82
    • (2001) Lab Chip , vol.1 , pp. 76-82
    • Gawad, S.1    Schild, L.2    Renaud, P.3
  • 21
    • 4344660693 scopus 로고    scopus 로고
    • Three-dimensional hydrodynamic focusing in polydimethylsiloxane (PDMS) microchannels
    • Sundararajan N, Pio M S, Lee L P and Berlin A A 2004 Three-dimensional hydrodynamic focusing in polydimethylsiloxane (PDMS) microchannels IEEE Trans. J. MEMS 13 559-67
    • (2004) IEEE Trans. J. MEMS , vol.13 , pp. 559-567
    • Sundararajan, N.1    Pio, M.S.2    Lee, L.P.3    Berlin, A.A.4
  • 22
    • 42949107116 scopus 로고    scopus 로고
    • Three-dimensional hydrodynamic focusing in a microfluidic Coulter counter
    • Scott R, Sethu P and Harnett C K 2008 Three-dimensional hydrodynamic focusing in a microfluidic Coulter counter Rev. Sci. Instrum. 79 046104
    • (2008) Rev. Sci. Instrum. , vol.79 , pp. 046104
    • Scott, R.1    Sethu, P.2    Harnett, C.K.3
  • 23
    • 36448977298 scopus 로고    scopus 로고
    • Broadband single cell impedance spectroscopy using maximum length sequences: Theoretical analysis and practical considerations
    • DOI 10.1088/0957-0233/18/9/015, PII S0957023307451414
    • Sun T, Gawad S, Bernabini C, Green N G and Morgan H 2007 Broadband single cell impedance spectroscopy using maximum length sequences: theoretical analysis and practical considerations Meas. Sci. Technol. 18 2859-68 (Pubitemid 350163569)
    • (2007) Measurement Science and Technology , vol.18 , Issue.9 , pp. 2859-2868
    • Sun, T.1    Gawad, S.2    Bernabini, C.3    Green, N.G.4    Morgan, H.5
  • 24
    • 31044451561 scopus 로고    scopus 로고
    • High throughput particle analysis: Combining dielectrophoretic particle focusing with confocal optical detection
    • Holmes D, Morgan H and Green N G 2006 High throughput particle analysis: combining dielectrophoretic particle focusing with confocal optical detection Biosens. Bioelectron. 21 1621-30
    • (2006) Biosens. Bioelectron. , vol.21 , pp. 1621-1630
    • Holmes, D.1    Morgan, H.2    Green, N.G.3
  • 25
    • 63749098176 scopus 로고    scopus 로고
    • Optical microflow cytometer for particle counting, sizing and fluorescence detection
    • Chen H T and Wang Y N 2009 Optical microflow cytometer for particle counting, sizing and fluorescence detection Microfluid Nanofluid 6 529-37
    • (2009) Microfluid Nanofluid , vol.6 , pp. 529-537
    • Chen, H.T.1    Wang, Y.N.2
  • 26
    • 77957762211 scopus 로고
    • US Patent 2656508
    • Coulter W H 1953 US Patent 2656508
    • (1953)
    • Coulter, W.H.1
  • 27
    • 40349099998 scopus 로고    scopus 로고
    • Micro Coulter counters with platinum black electroplated electrodes for human blood cell sensing
    • Zheng S, Liu M and Tai Y 2008 Micro Coulter counters with platinum black electroplated electrodes for human blood cell sensing Biomed. Microdevices 10 221-31
    • (2008) Biomed. Microdevices , vol.10 , pp. 221-231
    • Zheng, S.1    Liu, M.2    Tai, Y.3
  • 29
    • 44649144552 scopus 로고    scopus 로고
    • Experimental characterization of a metal-oxide-semiconductor field-effect transistor-based Coulter counter
    • Sridhar M, Xu D, Kang Y, Hmelo A B, Feldman L C, Li D and Li D 2008 Experimental characterization of a metal-oxide-semiconductor field-effect transistor-based Coulter counter J. Appl. Phys. 103 104701
    • (2008) J. Appl. Phys. , vol.103 , pp. 104701
    • Sridhar, M.1    Xu, D.2    Kang, Y.3    Hmelo, A.B.4    Feldman, L.C.5    Li, D.6    Li, D.7
  • 31
    • 68549121133 scopus 로고    scopus 로고
    • Capacitive Coulter counting: Detection of metal wear particles in lubricant using a microfluidic device
    • Murali S, Xia X, Jagtiani A V, Carletta J and Zhe J 2008 Capacitive Coulter counting: detection of metal wear particles in lubricant using a microfluidic device Smart Mater. Struct. 18 037001
    • (2008) Smart Mater. Struct. , vol.18 , pp. 037001
    • Murali, S.1    Xia, X.2    Jagtiani, A.V.3    Carletta, J.4    Zhe, J.5
  • 32
    • 0017648259 scopus 로고
    • Regulation of cellular volume
    • Macknight A D C and Leaf A 1977 Regulation of cellular volume Physiol. Rev. 57 137-54
    • (1977) Physiol. Rev. , vol.57 , pp. 137-154
    • MacKnight, A.D.C.1    Leaf, A.2
  • 34
    • 72849135355 scopus 로고    scopus 로고
    • Dielectrophoresis for manipulation of micro/nano particles in microfluidic systems
    • Zhang C, Khoshmanesh K, Mitchell A and Kalantar-zadeh K 2010 Dielectrophoresis for manipulation of micro/nano particles in microfluidic systems Anal. Bioanal. Chem. 396 401-20
    • (2010) Anal. Bioanal. Chem. , vol.396 , pp. 401-420
    • Zhang, C.1    Khoshmanesh, K.2    Mitchell, A.3    Kalantar-Zadeh, K.4
  • 35
    • 65949096098 scopus 로고    scopus 로고
    • Continuous particle separation by size via AC-dielectrophoresis using a lab-on-a-chip device with 3-D electrodes
    • Çetin B, Kang Y, Wu Z and Li D 2009 Continuous particle separation by size via AC-dielectrophoresis using a lab-on-a-chip device with 3-D electrodes Electrophoresis 30 766-72
    • (2009) Electrophoresis , vol.30 , pp. 766-772
    • Çetin, B.1    Kang, Y.2    Wu, Z.3    Li, D.4
  • 37
    • 34147140510 scopus 로고    scopus 로고
    • Side-Wall vertical electrodes for lateral field microfluidic applications
    • Wang L, Flanagan L and Lee A P 2007 Side-Wall vertical electrodes for lateral field microfluidic applications J. Microelectromech. Syst. 16 454-61
    • (2007) J. Microelectromech. Syst. , vol.16 , pp. 454-461
    • Wang, L.1    Flanagan, L.2    Lee, A.P.3
  • 38
    • 0141989814 scopus 로고    scopus 로고
    • Micromachined impedance spectroscopy flow cytometer forcell analysis and particle sizing
    • Gawad S, Schildb L and Renauda P 2001 Micromachined impedance spectroscopy flow cytometer forcell analysis and particle sizing Lab Chip 1 76-82
    • (2001) Lab Chip , vol.1 , pp. 76-82
    • Gawad, S.1    Schildb, L.2    Renauda, P.3
  • 39
    • 43749112945 scopus 로고    scopus 로고
    • An effective passive microfluidic mixer utilizing chaotic advection
    • Nguyen T N T, Kimb M C, Park J S and Lee N E 2008 An effective passive microfluidic mixer utilizing chaotic advection Sensors Actuators B 132 172-81
    • (2008) Sensors Actuators B , vol.132 , pp. 172-181
    • Nguyen, T.N.T.1    Kimb, M.C.2    Park, J.S.3    Lee, N.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.