메뉴 건너뛰기




Volumn 4, Issue 4, 2010, Pages 103-108

Miniaturisation of a capillary electrophoresis microchip for the sensing of endocrine disruptors

Author keywords

[No Author keywords available]

Indexed keywords

AMPEROMETRIC DETECTOR; ANALYTES; ANALYTICAL TOOL; CAPILLARY ELECTROPHORESIS MICROCHIP; DETECTOR SENSITIVITY; ENDOCRINE DISRUPTOR; INDIUM TIN OXIDE; MINIATURISATION; PRUSSIAN BLUE;

EID: 77957374306     PISSN: 17518741     EISSN: None     Source Type: Journal    
DOI: 10.1049/iet-nbt.2010.0006     Document Type: Article
Times cited : (3)

References (26)
  • 1
    • 33745106076 scopus 로고    scopus 로고
    • Mechanisms and risk of chemically induced aneuploidy in mammalian germ cells
    • Pacchierotti, F., and Ranaldi, R.: ' Mechanisms and risk of chemically induced aneuploidy in mammalian germ cells ', Curr. Pharm. Des., 2006, 12, (12), p. 1489-1504
    • (2006) Curr. Pharm. Des. , vol.12 , Issue.12 , pp. 1489-1504
    • Pacchierotti, F.1    Ranaldi, R.2
  • 2
    • 39749196295 scopus 로고    scopus 로고
    • Modulatory effect of environmental endocrine disruptors on N-ras oncogene expression in the hermaphroditic fish, Kryptolebias marmoratus
    • Lee, Y.M., Raisuddin, S., Rhee, J.S., Ki, J.S., Kim, I.C., and Lee, J.S.: ' Modulatory effect of environmental endocrine disruptors on N-ras oncogene expression in the hermaphroditic fish, Kryptolebias marmoratus ', Comp. Biochem. Physiol. C: Toxicol. Pharmacol., 2008, 147, (3), p. 299-305
    • (2008) Comp. Biochem. Physiol. C: Toxicol. Pharmacol. , vol.147 , Issue.3 , pp. 299-305
    • Lee, Y.M.1    Raisuddin, S.2    Rhee, J.S.3    Ki, J.S.4    Kim, I.C.5    Lee, J.S.6
  • 3
    • 33846264036 scopus 로고    scopus 로고
    • Bisphenol A facilitates bypass of androgen ablation therapy in prostate cancer
    • et al. ' ', ()
    • Wetherill, Y.B., Hess-Wilson, J.K., and Comstock, C.E.: et al. ' Bisphenol A facilitates bypass of androgen ablation therapy in prostate cancer ', Mol. Cancer Ther., 2006, 5, (12), p. 3181-3190
    • (2006) Mol. Cancer Ther. , vol.5 , Issue.12 , pp. 3181-3190
    • Wetherill, Y.B.1    Hess-Wilson, J.K.2    Comstock, C.E.3
  • 4
    • 0036411957 scopus 로고    scopus 로고
    • Mutagenicity of bisphenol A (4,4(-isopropylidenediphenol) in vitro: Effects of nitrosylation
    • Schrader, T.J., Langlois, I., Soper, K., and Cherry, W.: ' Mutagenicity of bisphenol A (4,4(-isopropylidenediphenol) in vitro: effects of nitrosylation ', Teratog. Carcinog. Mutagen., 2002, 22, (6), p. 425-441
    • (2002) Teratog. Carcinog. Mutagen. , vol.22 , Issue.6 , pp. 425-441
    • Schrader, T.J.1    Langlois, I.2    Soper, K.3    Cherry, W.4
  • 5
    • 18944362112 scopus 로고    scopus 로고
    • Occupational allergic contact dermatitis to bisphenol F epoxy resin
    • DOI 10.1111/j.1440-0960.2005.00149.x
    • Sakata, S., Cahill, J., Barton, D., and Nixon, R.: ' Occupational allergic contact dermatitis to bisphenol F epoxy resin ', Australas. J. Dermatol., 2005, 46, (2), p. 90-92 (Pubitemid 40704885)
    • (2005) Australasian Journal of Dermatology , vol.46 , Issue.2 , pp. 90-92
    • Sakata, S.1    Cahill, J.2    Barton, D.3    Nixon, R.4
  • 6
    • 37549001791 scopus 로고    scopus 로고
    • Bisphenol A is released from polycarbonate drinking bottles and mimics the neurotoxic actions of estrogen in developing cerebellar neurons
    • Le, H.H., Carlson, E.M., Chua, J.P., and Belcher, S.M.: ' Bisphenol A is released from polycarbonate drinking bottles and mimics the neurotoxic actions of estrogen in developing cerebellar neurons ', Toxicol. Lett., 2008, 176, (2), p. 149-156
    • (2008) Toxicol. Lett. , vol.176 , Issue.2 , pp. 149-156
    • Le, H.H.1    Carlson, E.M.2    Chua, J.P.3    Belcher, S.M.4
  • 7
    • 30944443532 scopus 로고    scopus 로고
    • Piezoelectric immunosensor for bisphenol A based on signal enhancing step with 2-methacrolyloxyethyl phosphorylcholine polymeric nanoparticle
    • 0003-2654
    • Park, J.W., Kurosawa, S., Aizawa, H., Goda, Y., Takai, M., and Ishihara, K.: ' Piezoelectric immunosensor for bisphenol A based on signal enhancing step with 2-methacrolyloxyethyl phosphorylcholine polymeric nanoparticle ', Analyst, 2006, 131, (1), p. 155-162 0003-2654
    • (2006) Analyst , vol.131 , Issue.1 , pp. 155-162
    • Park, J.W.1    Kurosawa, S.2    Aizawa, H.3    Goda, Y.4    Takai, M.5    Ishihara, K.6
  • 8
    • 34548504367 scopus 로고    scopus 로고
    • Enzymatic determination of BPA by means of tyrosinase immobilized on different carbon carriers
    • 0956-5663
    • Mita, D.G., Attanasio, A., and Arduini, F.: et al. ' Enzymatic determination of BPA by means of tyrosinase immobilized on different carbon carriers ', Biosens. Bioelectron., 2007, 23, (1), p. 60-65 0956-5663
    • (2007) Biosens. Bioelectron. , vol.23 , Issue.1 , pp. 60-65
    • Mita, D.G.1    Attanasio, A.2    Arduini, F.3
  • 9
    • 0032728527 scopus 로고    scopus 로고
    • Sensitive method for the determination of bisphenol-A in serum using two systems of high-performance liquid chromatography
    • Sajiki, J., Takahashi, K., and Yonekubo, J.: ' Sensitive method for the determination of bisphenol-A in serum using two systems of high-performance liquid chromatography ', J. Chromatogr. B, 1999, 736, p. 255-261
    • (1999) J. Chromatogr. B , vol.736 , pp. 255-261
    • Sajiki, J.1    Takahashi, K.2    Yonekubo, J.3
  • 10
    • 0347723968 scopus 로고    scopus 로고
    • Ng/l Level of BPA determination existing in natural water with HPLC-electrochemical detection
    • Watabe, Y., Hosoya, K., Tanaka, N., Kondo, T., Imai, H., and Morita, M.: ' ng/l Level of BPA determination existing in natural water with HPLC-electrochemical detection ', Jpn. Anal., 2003, 52, p. 1167-1172
    • (2003) Jpn. Anal. , vol.52 , pp. 1167-1172
    • Watabe, Y.1    Hosoya, K.2    Tanaka, N.3    Kondo, T.4    Imai, H.5    Morita, M.6
  • 11
    • 17944362464 scopus 로고    scopus 로고
    • Determination of bisphenol A in food-simulating liquids using LCED with a chemically modified electrode
    • D'Antuono, A., Dall'Orto, V.C., Balbo, A.L., Sobral, S., and Rezzano, I.: ' Determination of bisphenol A in food-simulating liquids using LCED with a chemically modified electrode ', J. Agric. Food Chem., 2001, 49, p. 1098-1101
    • (2001) J. Agric. Food Chem. , vol.49 , pp. 1098-1101
    • D'Antuono, A.1    Dall'Orto, V.C.2    Balbo, A.L.3    Sobral, S.4    Rezzano, I.5
  • 12
    • 70349436833 scopus 로고    scopus 로고
    • Review of recent advances in analytical techniques for the determination of neurotransmitters
    • Perry, M., Li, Q., and Kennedy, R.T.: ' Review of recent advances in analytical techniques for the determination of neurotransmitters ', Anal. Chim. Acta, 2009, 653, (1), p. 1-22
    • (2009) Anal. Chim. Acta , vol.653 , Issue.1 , pp. 1-22
    • Perry, M.1    Li, Q.2    Kennedy, R.T.3
  • 13
    • 71849118556 scopus 로고    scopus 로고
    • A capillary electrophoresis microchip for amperometric detection of DNA
    • Joo, G.-S., Jha, S.K., and Kim, Y.-S.: ' A capillary electrophoresis microchip for amperometric detection of DNA ', Curr. Appl. Phys., 2009, 9, p. e222-e224
    • (2009) Curr. Appl. Phys. , vol.9
    • Joo, G.-S.1    Jha, S.K.2    Kim, Y.-S.3
  • 14
    • 2342552469 scopus 로고    scopus 로고
    • Amperometric detection of morphine at a Prussian blue-modified indium tin oxide electrode
    • 0956-5663
    • Ho, K.C., Chen, C.Y., Hsu, H.C., Chen, L.C., Shiesh, S.C., and Lin, X.Z.: ' Amperometric detection of morphine at a Prussian blue-modified indium tin oxide electrode ', Biosens. Bioelectron., 2004, 20, (1), p. 3-8 0956-5663
    • (2004) Biosens. Bioelectron. , vol.20 , Issue.1 , pp. 3-8
    • Ho, K.C.1    Chen, C.Y.2    Hsu, H.C.3    Chen, L.C.4    Shiesh, S.C.5    Lin, X.Z.6
  • 15
    • 0034671973 scopus 로고    scopus 로고
    • Dynamic coating using polyelectrolyte multilayers for chemical control of electroosmotic flow in capillary electrophoresis microchips
    • 0003-2700
    • Liu, Y., Fanguy, J.C., Bledsoe, J.M., and Henry, C.S.: ' Dynamic coating using polyelectrolyte multilayers for chemical control of electroosmotic flow in capillary electrophoresis microchips ', Anal. Chem., 2000, 72, p. 5939-5944 0003-2700
    • (2000) Anal. Chem. , vol.72 , pp. 5939-5944
    • Liu, Y.1    Fanguy, J.C.2    Bledsoe, J.M.3    Henry, C.S.4
  • 16
    • 0035068511 scopus 로고    scopus 로고
    • Carbon paste-based electrochemical detectors for microchip capillary electrophoresis/electrochemistry
    • 0003-2654
    • Martin, R.S., Gawron, A.J., Lunte, S.M., Fogarty, B.A., and Regan, F.B.: ' Carbon paste-based electrochemical detectors for microchip capillary electrophoresis/electrochemistry ', Analyst, 2001, 126, p. 277-280 0003-2654
    • (2001) Analyst , vol.126 , pp. 277-280
    • Martin, R.S.1    Gawron, A.J.2    Lunte, S.M.3    Fogarty, B.A.4    Regan, F.B.5
  • 17
    • 0035866639 scopus 로고    scopus 로고
    • Microseparation chips for performing ultienzymatic dehydrogenase/oxidase assays: Simultaneous electrochemical measurement of ethanol glucose
    • 0003-2700
    • Wang, J., Chatrathi, M.P., and Tian, B.: ' Microseparation chips for performing ultienzymatic dehydrogenase/oxidase assays: simultaneous electrochemical measurement of ethanol glucose ', Anal. Chem., 2001, 73, p. 1296-1300 0003-2700
    • (2001) Anal. Chem. , vol.73 , pp. 1296-1300
    • Wang, J.1    Chatrathi, M.P.2    Tian, B.3
  • 18
    • 37549023800 scopus 로고    scopus 로고
    • On-column conductivity detection in capillary-chip electrophoresis
    • 0173-0835
    • Wu, Z.Y., Fang, F., Josserand, J., and Girault, H.H.: ' On-column conductivity detection in capillary-chip electrophoresis ', Electrophoresis, 2007, 28, (24), p. 4612-4619 0173-0835
    • (2007) Electrophoresis , vol.28 , Issue.24 , pp. 4612-4619
    • Wu, Z.Y.1    Fang, F.2    Josserand, J.3    Girault, H.H.4
  • 19
    • 67349133139 scopus 로고    scopus 로고
    • Monitoring of endocrine disruptors by capillary electrophoresis amperometric detector
    • 0167-9317
    • Ha, K., Joo, G.s., Jha, S.K., and Kim, Y.S.: ' Monitoring of endocrine disruptors by capillary electrophoresis amperometric detector ', Microelectron. Eng., 2009, 86, (4-6), p. 1407-1410 0167-9317
    • (2009) Microelectron. Eng. , vol.86 , Issue.46 , pp. 1407-1410
    • Ha, K.1    Joo, G.S.2    Jha, S.K.3    Kim, Y.S.4
  • 20
    • 33646057002 scopus 로고    scopus 로고
    • A disposable biosensor with prussian blue deposited electrode
    • 0167-9317
    • Yi, I.-J., Kim, J.-H., Choi, Y.J., Kang, C.J., and Kim, Y.-S.: ' A disposable biosensor with prussian blue deposited electrode ', Microelectron. Eng., 2006, 83, p. 1594-1597 0167-9317
    • (2006) Microelectron. Eng. , vol.83 , pp. 1594-1597
    • Yi, I.-J.1    Kim, J.-H.2    Choi, Y.J.3    Kang, C.J.4    Kim, Y.-S.5
  • 21
    • 0346341044 scopus 로고    scopus 로고
    • A disposable polydimethylsiloxane-based diffuser micropump actuated by piezoelectric-disc
    • 0167-9317
    • Kim, J.H., Kang, C.J., and Kim, Y.-S.: ' A disposable polydimethylsiloxane-based diffuser micropump actuated by piezoelectric-disc ', Microelectron. Eng., 2004, 71, p. 119-124 0167-9317
    • (2004) Microelectron. Eng. , vol.71 , pp. 119-124
    • Kim, J.H.1    Kang, C.J.2    Kim, Y.-S.3
  • 22
    • 2542425060 scopus 로고    scopus 로고
    • A disposable thermopneumatic-actuated microvalve stacked with PDMS layers ITO-coated glass
    • 0167-9317
    • Kim, J.H., Kang, C.J., and Kim, Y.-S.: ' A disposable thermopneumatic-actuated microvalve stacked with PDMS layers ITO-coated glass ', Microelectron. Eng., 2004, 73/74, p. 864-869 0167-9317
    • (2004) Microelectron. Eng. , vol.7374 , pp. 864-869
    • Kim, J.H.1    Kang, C.J.2    Kim, Y.-S.3
  • 23
    • 0034662187 scopus 로고    scopus 로고
    • Dual-electrode electrochemical detection for poly(dimethylsiloxane)- fabricated capillary electrophoresis microchips
    • 0003-2700
    • Martin, R.S., Gawron, A.J., Lunte, S.M., and Henry, C.S.: ' Dual-electrode electrochemical detection for poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips ', Anal. Chem., 2000, 72, p. 3196-3202 0003-2700
    • (2000) Anal. Chem. , vol.72 , pp. 3196-3202
    • Martin, R.S.1    Gawron, A.J.2    Lunte, S.M.3    Henry, C.S.4
  • 24
    • 71849092702 scopus 로고    scopus 로고
    • Electrochemical cell lysis on a miniaturized flow-through device
    • Jha, S.K., Ra, G.-S., Joo, G.-S., and Kim, Y.-S.: ' Electrochemical cell lysis on a miniaturized flow-through device ', Curr. Appl. Phys., 2009, 9, p. e301-e303
    • (2009) Curr. Appl. Phys. , vol.9
    • Jha, S.K.1    Ra, G.-S.2    Joo, G.-S.3    Kim, Y.-S.4
  • 25
    • 77951085647 scopus 로고    scopus 로고
    • End-to-end differential contactless conductivity sensor for microchip capillary electrophoresis
    • 0003-2700
    • Fercher, G., Haller, A., Smetana, W., and Vellekoop, M.J.: ' End-to-end differential contactless conductivity sensor for microchip capillary electrophoresis ', Anal. Chem., 2010, 82, (8), p. 3270-3275 0003-2700
    • (2010) Anal. Chem. , vol.82 , Issue.8 , pp. 3270-3275
    • Fercher, G.1    Haller, A.2    Smetana, W.3    Vellekoop, M.J.4
  • 26
    • 37149044429 scopus 로고    scopus 로고
    • Analysis of glyphosate and aminomethylphosphonic acid by capillary electrophoresis with electrochemiluminescence detection
    • Chiu, H.Y., Lin, Z.Y., Tu, H.L., and Whang, C.W.: ' Analysis of glyphosate and aminomethylphosphonic acid by capillary electrophoresis with electrochemiluminescence detection ', J. Chromatogr. A, 2008, 1177, (1), p. 195-198
    • (2008) J. Chromatogr. A , vol.1177 , Issue.1 , pp. 195-198
    • Chiu, H.Y.1    Lin, Z.Y.2    Tu, H.L.3    Whang, C.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.