메뉴 건너뛰기




Volumn 48, Issue 5, 2010, Pages 893-901

The Basics and Implementation of Digital Mammography

Author keywords

Basics; Breast imaging; Digital mammography; Implementation

Indexed keywords

ALGORITHM; ANALYTICAL EQUIPMENT; ARTIFACT; CALIBRATION; CANCER SCREENING; CLINICAL EFFECTIVENESS; COMMUNICATION SOFTWARE; COMPUTER ASSISTED DIAGNOSIS; DIGITAL MAMMOGRAPHY; DISEASE CLASSIFICATION; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE QUALITY; INFORMATION PROCESSING; INFORMATION SYSTEM; PRIORITY JOURNAL; REVIEW; SAFETY; WORKPLACE; BREAST NEOPLASMS; DEVICES; EARLY DIAGNOSIS; FEMALE; HEALTH CARE PLANNING; MAMMOGRAPHY; PROCEDURES; RADIOGRAPHY; UNITED STATES;

EID: 77956908658     PISSN: 00338389     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.rcl.2010.06.003     Document Type: Review
Times cited : (6)

References (29)
  • 1
    • 0036721482 scopus 로고    scopus 로고
    • Clinical comparison of full-field digital mammography and screen-film mammography for detection of breast cancer
    • Lewin J.M., D'Orsi C.J., Hendrick R.E., et al. Clinical comparison of full-field digital mammography and screen-film mammography for detection of breast cancer. AJR Am J Roentgenol 2002, 179:671-677.
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 671-677
    • Lewin, J.M.1    D'Orsi, C.J.2    Hendrick, R.E.3
  • 2
    • 0344153008 scopus 로고    scopus 로고
    • Population-based mammography screening: comparison of screen-films and full field digital mammography with soft-copy reading-Oslo I Study
    • Skaane P., Young K., Skjennald A. Population-based mammography screening: comparison of screen-films and full field digital mammography with soft-copy reading-Oslo I Study. Radiology 2003, 229:877-884.
    • (2003) Radiology , vol.229 , pp. 877-884
    • Skaane, P.1    Young, K.2    Skjennald, A.3
  • 3
    • 27344458270 scopus 로고    scopus 로고
    • Diagnostic performance of digital versus film mammography for breast-cancer screening
    • Pisano E.D., Gatsonis C., Hendrik E. Diagnostic performance of digital versus film mammography for breast-cancer screening. N Engl J Med 2005, 353:1773-1783.
    • (2005) N Engl J Med , vol.353 , pp. 1773-1783
    • Pisano, E.D.1    Gatsonis, C.2    Hendrik, E.3
  • 4
    • 34748834570 scopus 로고    scopus 로고
    • Full-field digital versus screen-film mammography: comparative accuracy in concurrent screening cohorts
    • DelTurco M.R., Mantelli P., Ciatto S., et al. Full-field digital versus screen-film mammography: comparative accuracy in concurrent screening cohorts. AJR Am J Roentgenol 2007, 189:860-866.
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 860-866
    • DelTurco, M.R.1    Mantelli, P.2    Ciatto, S.3
  • 5
    • 2942711553 scopus 로고    scopus 로고
    • Screen-film mammography versus full-field digital mammography with soft-copy reading: randomized trial in a population-based screening program - The Oslo II Study
    • Skaane P., Skjennald A. Screen-film mammography versus full-field digital mammography with soft-copy reading: randomized trial in a population-based screening program - The Oslo II Study. Radiology 2004, 232:197-204.
    • (2004) Radiology , vol.232 , pp. 197-204
    • Skaane, P.1    Skjennald, A.2
  • 6
    • 19944432121 scopus 로고    scopus 로고
    • Comparison of screen-film and full-field digital mammography in Japanese population-based screening
    • Yamada T., Saito M., Ishibashi T., et al. Comparison of screen-film and full-field digital mammography in Japanese population-based screening. Radiat Med 2004, 22:408-412.
    • (2004) Radiat Med , vol.22 , pp. 408-412
    • Yamada, T.1    Saito, M.2    Ishibashi, T.3
  • 7
    • 66149104487 scopus 로고    scopus 로고
    • Full-field digital versus screen-film mammography: comparison within the UK breast screening program and systematic review of published data
    • Vinnicombe S., Pinto Pereira S., McCormack V.A., et al. Full-field digital versus screen-film mammography: comparison within the UK breast screening program and systematic review of published data. Radiology 2009, 251:347-358.
    • (2009) Radiology , vol.251 , pp. 347-358
    • Vinnicombe, S.1    Pinto Pereira, S.2    McCormack, V.A.3
  • 8
    • 68149099589 scopus 로고    scopus 로고
    • Digital mammography: its impact on recall rates and cancer detection rates in a small community-based radiology practice
    • Vernacchia F.S., Pena Z.G. Digital mammography: its impact on recall rates and cancer detection rates in a small community-based radiology practice. AJR Am J Roentgenol 2009, 193:582-585.
    • (2009) AJR Am J Roentgenol , vol.193 , pp. 582-585
    • Vernacchia, F.S.1    Pena, Z.G.2
  • 9
    • 70349671353 scopus 로고    scopus 로고
    • Comparison of digital mammography and screen-film mammography in breast cancer screening: a review in the Irish breast screening program
    • Hambly N.M., McNicholas M.M., Phelan N., et al. Comparison of digital mammography and screen-film mammography in breast cancer screening: a review in the Irish breast screening program. AJR Am J Roentgenol 2009, 193:1010-1018.
    • (2009) AJR Am J Roentgenol , vol.193 , pp. 1010-1018
    • Hambly, N.M.1    McNicholas, M.M.2    Phelan, N.3
  • 10
    • 60649083158 scopus 로고    scopus 로고
    • Studies comparing screen-film mammography and full-field digital mammography in breast cancer screening: updated review
    • Skaane P. Studies comparing screen-film mammography and full-field digital mammography in breast cancer screening: updated review. Acta Radiol 2009, 50:3-14.
    • (2009) Acta Radiol , vol.50 , pp. 3-14
    • Skaane, P.1
  • 11
    • 80052365555 scopus 로고    scopus 로고
    • Detectors for digital mammography
    • Lippincott, Williams & Wilkins, Philadelphia, E.D. Pisano, M.J. Yaffe, C.M. Kuzmiak (Eds.)
    • Yaffe M.J. Detectors for digital mammography. Digital mammography 2004, 15-26. Lippincott, Williams & Wilkins, Philadelphia. E.D. Pisano, M.J. Yaffe, C.M. Kuzmiak (Eds.).
    • (2004) Digital mammography , pp. 15-26
    • Yaffe, M.J.1
  • 12
    • 8344227648 scopus 로고    scopus 로고
    • Digital detectors for mammography: the technical challenges
    • Noel A., Thibault F. Digital detectors for mammography: the technical challenges. Eur Radiol 2004, 14:1990-1998.
    • (2004) Eur Radiol , vol.14 , pp. 1990-1998
    • Noel, A.1    Thibault, F.2
  • 13
    • 34848839512 scopus 로고    scopus 로고
    • Digital mammography: clinical implementation and clinical trials
    • D'Orsi C.J., Newell M.S. Digital mammography: clinical implementation and clinical trials. Semin Roentgenol 2007, 42:236-242.
    • (2007) Semin Roentgenol , vol.42 , pp. 236-242
    • D'Orsi, C.J.1    Newell, M.S.2
  • 14
  • 15
    • 77956905266 scopus 로고    scopus 로고
    • Physics of digital mammography
    • Lippincott, Williams & Wilkins, Philadelphia, E.D. Pisano, M.J. Yaffe, C.M. Kuzmiak (Eds.)
    • Yaffe M.J. Physics of digital mammography. Digital mammography 2004, 4-14. Lippincott, Williams & Wilkins, Philadelphia. E.D. Pisano, M.J. Yaffe, C.M. Kuzmiak (Eds.).
    • (2004) Digital mammography , pp. 4-14
    • Yaffe, M.J.1
  • 17
    • 58149181878 scopus 로고    scopus 로고
    • Detector of system? Extending the concept of detective quantum efficiency to characterize the performance of digital radiographic imaging systems
    • Samei E., Ranger N.T., Mackenzie A., et al. Detector of system? Extending the concept of detective quantum efficiency to characterize the performance of digital radiographic imaging systems. Radiology 2008, 249:926-937.
    • (2008) Radiology , vol.249 , pp. 926-937
    • Samei, E.1    Ranger, N.T.2    Mackenzie, A.3
  • 18
    • 12344251753 scopus 로고    scopus 로고
    • Digital mammogarphy
    • Pisano E.D., Yaffe M.J. Digital mammogarphy. Radiology 2005, 234:353-362.
    • (2005) Radiology , vol.234 , pp. 353-362
    • Pisano, E.D.1    Yaffe, M.J.2
  • 19
    • 61349111302 scopus 로고    scopus 로고
    • Evaluation of clinical image processing algorithms used in digital mammography
    • Zanca F., Jacobs J. Evaluation of clinical image processing algorithms used in digital mammography. Med Phys 2009, 36:765-775.
    • (2009) Med Phys , vol.36 , pp. 765-775
    • Zanca, F.1    Jacobs, J.2
  • 20
    • 77957553846 scopus 로고    scopus 로고
    • Comparison of tissue equalization, and premium view post processing methods in full field digital mammography
    • Chen B., Wang W., Huang J. Comparison of tissue equalization, and premium view post processing methods in full field digital mammography. Eur J Radiol 2009, 10.1016/j.ejrad.2009.05.010.
    • (2009) Eur J Radiol
    • Chen, B.1    Wang, W.2    Huang, J.3
  • 21
    • 76149121807 scopus 로고    scopus 로고
    • The effect of premium view post-processing software on digital mammography reporting
    • Goldstraw E.J., Castellano I., Ashley S., et al. The effect of premium view post-processing software on digital mammography reporting. Br J Radiol 2010, 83(986):122-128.
    • (2010) Br J Radiol , vol.83 , Issue.986 , pp. 122-128
    • Goldstraw, E.J.1    Castellano, I.2    Ashley, S.3
  • 22
    • 67650364849 scopus 로고    scopus 로고
    • Detection of masses and calcifications by soft-copy reading: comparison of two post-processing algorithms for full-field digital mammography
    • Uematsu T. Detection of masses and calcifications by soft-copy reading: comparison of two post-processing algorithms for full-field digital mammography. Jpn J Radiol 2009, 27:168-175.
    • (2009) Jpn J Radiol , vol.27 , pp. 168-175
    • Uematsu, T.1
  • 23
    • 12144262248 scopus 로고    scopus 로고
    • Available at:, Accessed August 19, 2010
    • IHE technical framework Available at:, Accessed August 19, 2010. http://www.ihe.net/Technical_Framework/index.cfm#radiology.
    • IHE technical framework
  • 25
    • 68049139345 scopus 로고    scopus 로고
    • Artifacts found during quality assurance testing of computed radiography and digital radiography detectors
    • Honey I.D., Mackenzie A. Artifacts found during quality assurance testing of computed radiography and digital radiography detectors. J Digit Imaging 2009, 22:383-392.
    • (2009) J Digit Imaging , vol.22 , pp. 383-392
    • Honey, I.D.1    Mackenzie, A.2
  • 26
    • 58149383876 scopus 로고    scopus 로고
    • Digital mammographic artifacts on full-field system: what are they and how do I fix them?
    • Ayyala R.S., Chorlton M.A., Behrman R.H., et al. Digital mammographic artifacts on full-field system: what are they and how do I fix them?. RadioGraphics 2008, 28:1999-2008.
    • (2008) RadioGraphics , vol.28 , pp. 1999-2008
    • Ayyala, R.S.1    Chorlton, M.A.2    Behrman, R.H.3
  • 27
    • 59249084566 scopus 로고    scopus 로고
    • Characterization of microcalcification: can digital monitor zooming replace magnification mammography in full-field digital mammography?
    • Kim M.J., Kim E.K., Kwak J.Y. Characterization of microcalcification: can digital monitor zooming replace magnification mammography in full-field digital mammography?. Eur Radiol 2009, 19:310-317.
    • (2009) Eur Radiol , vol.19 , pp. 310-317
    • Kim, M.J.1    Kim, E.K.2    Kwak, J.Y.3
  • 28
    • 77952942146 scopus 로고    scopus 로고
    • Zooming method (×2.0) of digital mammography vs digital magnification view (×1.8) in full-field digital mammography for the diagnosis of microcalcifications
    • Kim M.J., Youk J.H., Kang D.R. Zooming method (×2.0) of digital mammography vs digital magnification view (×1.8) in full-field digital mammography for the diagnosis of microcalcifications. Br J Radiol 2009, 10.1259/bjr/16967819.
    • (2009) Br J Radiol
    • Kim, M.J.1    Youk, J.H.2    Kang, D.R.3
  • 29
    • 34547120688 scopus 로고    scopus 로고
    • Bick U. Dickmann Digital mammography: what do we and what don't we know?
    • Bick U., Dickmann Digital mammography: what do we and what don't we know?. Eur Radiol 2007, 17:1931-1942.
    • (2007) Eur Radiol , vol.17 , pp. 1931-1942


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.