메뉴 건너뛰기




Volumn 18, Issue 10, 2010, Pages 1360-1365

No early tibial tray loosening after surface cementing technique in mobile-bearing TKA

Author keywords

Cementing technique; Knee; Osteoarthritis; Surface cementation; Total knee arthroplasty

Indexed keywords

BONE CEMENT;

EID: 77956876599     PISSN: 09422056     EISSN: 14337347     Source Type: Journal    
DOI: 10.1007/s00167-010-1177-2     Document Type: Article
Times cited : (17)

References (26)
  • 1
    • 0034031656 scopus 로고    scopus 로고
    • Negative pressure intrusion cementation technique for total knee arthroplasty
    • Banwart JC, McQueen DA, Friis EA et al (2000) Negative pressure intrusion cementation technique for total knee arthroplasty. J Arthroplasty 3: 360-367.
    • (2000) J Arthroplasty , vol.3 , pp. 360-367
    • Banwart, J.C.1    McQueen, D.A.2    Friis, E.A.3
  • 2
    • 5344229386 scopus 로고    scopus 로고
    • Early failure of cementless mobile-bearing total knee arthroplasty
    • Winner of the 2003 James A. Rand Young Investigator's Award
    • Barrack RL, Nakamura SJ, Hopkins SG, Rosenzweig S, Winner of the 2003 James A. Rand Young Investigator's Award (2004) Early failure of cementless mobile-bearing total knee arthroplasty. J Arthroplasty 19: 101-106.
    • (2004) J Arthroplasty , vol.19 , pp. 101-106
    • Barrack, R.L.1    Nakamura, S.J.2    Hopkins, S.G.3    Rosenzweig, S.4
  • 3
    • 0032417379 scopus 로고    scopus 로고
    • Is it necessary to cement the tibial stem in cemented total knee arthroplasty?
    • Bert JM, McShane M (1998) Is it necessary to cement the tibial stem in cemented total knee arthroplasty? Clin Orthop Relat Res 356: 73-78.
    • (1998) Clin Orthop Relat Res , vol.356 , pp. 73-78
    • Bert, J.M.1    McShane, M.2
  • 5
    • 0021363781 scopus 로고
    • Factors influencing the intrusion of methylmethacrylate into human tibia
    • Dorr LD, Lindberg JP, Claude-Faugere M et al (1984) Factors influencing the intrusion of methylmethacrylate into human tibia. Clin Orthop Relat Res 183: 147-152.
    • (1984) Clin Orthop Relat Res , vol.183 , pp. 147-152
    • Dorr, L.D.1    Lindberg, J.P.2    Claude-Faugere, M.3
  • 6
    • 0024950156 scopus 로고
    • The knee society total knee arthroplasty roentgenographic evaluation and scoring system
    • Ewald FC (1989) The knee society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248: 9-12.
    • (1989) Clin Orthop Relat Res , vol.248 , pp. 9-12
    • Ewald, F.C.1
  • 8
    • 67650116261 scopus 로고    scopus 로고
    • Survival and clinical function of cemented and uncemented prostheses in total knee replacement: A meta-analysis
    • Gandhi R, Tsvetkov D, Davey JR, Mahomed NN (2009) Survival and clinical function of cemented and uncemented prostheses in total knee replacement: a meta-analysis. J Bone Joint Surg Br 91: 889-895.
    • (2009) J Bone Joint Surg Br , vol.91 , pp. 889-895
    • Gandhi, R.1    Tsvetkov, D.2    Davey, J.R.3    Mahomed, N.N.4
  • 9
    • 33646054524 scopus 로고    scopus 로고
    • Surface cementation of stemmed tibial components in primary total knee arthroplasty: Minimum 5-year follow-up
    • Hofmann AA, Goldberg TD, Tanner AM, Cook TM (2006) Surface cementation of stemmed tibial components in primary total knee arthroplasty: minimum 5-year follow-up. J Arthroplasty 21: 353-357.
    • (2006) J Arthroplasty , vol.21 , pp. 353-357
    • Hofmann, A.A.1    Goldberg, T.D.2    Tanner, A.M.3    Cook, T.M.4
  • 10
    • 33644870790 scopus 로고    scopus 로고
    • All-polyethylene vs. metal-backed tibial component in total knee arthroplasty a randomized RSA study comparing early fixation of horizontally and completely cemented tibial components: Part 2. Completely cemented components: MB not superior to AP components
    • Hyldahl H, Regner L, Carlsson L et al (2005) All-polyethylene vs. metal-backed tibial component in total knee arthroplasty a randomized RSA study comparing early fixation of horizontally and completely cemented tibial components: part 2. Completely cemented components: MB not superior to AP components. Acta Orthop 76: 778-784.
    • (2005) Acta Orthop , vol.76 , pp. 778-784
    • Hyldahl, H.1    Regner, L.2    Carlsson, L.3
  • 11
  • 13
    • 34347258917 scopus 로고    scopus 로고
    • Evolution of tibial fixation in total knee arthroplasty
    • Lombardi AV Jr, Berasi CC, Berend KR (2007) Evolution of tibial fixation in total knee arthroplasty. J Arthroplasty 22(4 Suppl 1): 25-29.
    • (2007) J Arthroplasty , vol.22 , Issue.4 SUPPL 1 , pp. 25-29
    • Lombardi Jr., A.V.1    Berasi, C.C.2    Berend, K.R.3
  • 14
    • 77956883208 scopus 로고    scopus 로고
    • Lombardi AV Jr, Mallory TH, Gunderson R, et al (1998) Surface-cementation of the tibial component in total knee arthroplasty. Proceedings 65th Annual Meeting of the American Academy of Orthopaedic Surgeons, New Orleans, LA, pp 1.
  • 15
    • 31144463937 scopus 로고    scopus 로고
    • Micromotion in cemented rotating platform total knee arthroplasty: Cemented tibial stem versus hybrid fixation
    • Luring C, Perlick L, Trepte C, Linhardt O, Perlick C, Plitz W, Grifka J (2006) Micromotion in cemented rotating platform total knee arthroplasty: cemented tibial stem versus hybrid fixation. Arch Orthop Trauma Surg 126: 45-48.
    • (2006) Arch Orthop Trauma Surg , vol.126 , pp. 45-48
    • Luring, C.1    Perlick, L.2    Trepte, C.3    Linhardt, O.4    Perlick, C.5    Plitz, W.6    Grifka, J.7
  • 16
    • 0028913298 scopus 로고
    • Cement penetration with pulsed lavage versus syringe irrigation in total knee arthroplasty
    • Maistrelli GL, Antonelli L, Fornasier V et al (1995) Cement penetration with pulsed lavage versus syringe irrigation in total knee arthroplasty. Clin Orthop Relat Res 312: 261-265.
    • (1995) Clin Orthop Relat Res , vol.312 , pp. 261-265
    • Maistrelli, G.L.1    Antonelli, L.2    Fornasier, V.3
  • 17
    • 0035211738 scopus 로고    scopus 로고
    • Micromotion between the half bearings in the interax prosthesis: A roentgen stereophotogrammetric analysis
    • Marcacci M, Soavi R, Loreti I et al (2001) Micromotion between the half bearings in the interax prosthesis: a roentgen stereophotogrammetric analysis. J Arthroplasty 16: 991-997.
    • (2001) J Arthroplasty , vol.16 , pp. 991-997
    • Marcacci, M.1    Soavi, R.2    Loreti, I.3
  • 18
    • 73149085753 scopus 로고    scopus 로고
    • Combined syringe cement pressurisation and intra-osseous suction: An effective technique in total knee arthroplasty
    • Matthews JJ, Ball L, Blake SM, Cox PJ (2009) Combined syringe cement pressurisation and intra-osseous suction: an effective technique in total knee arthroplasty. Acta Orthop Belg 75: 637-641.
    • (2009) Acta Orthop Belg , vol.75 , pp. 637-641
    • Matthews, J.J.1    Ball, L.2    Blake, S.M.3    Cox, P.J.4
  • 19
    • 0037388823 scopus 로고    scopus 로고
    • Tibial component fixation with cement. Full-versus surface-cementation techniques
    • Peters CL, Craig MA, Mohr RA, Bachus KN (2003) Tibial component fixation with cement. Full-versus surface-cementation techniques. Clin Orthop Relat Res 409: 158-168.
    • (2003) Clin Orthop Relat Res , vol.409 , pp. 158-168
    • Peters, C.L.1    Craig, M.A.2    Mohr, R.A.3    Bachus, K.N.4
  • 22
    • 0003991124 scopus 로고    scopus 로고
    • Does a central stem affect bone strain and the stability of a cemented tibial tray in primary and revision TKA?
    • Seki T, Bourgeault ST, Chareancholvanich K, Lew W et al (1997) Does a central stem affect bone strain and the stability of a cemented tibial tray in primary and revision TKA? Orthop Trans 21: 635-640.
    • (1997) Orthop Trans , vol.21 , pp. 635-640
    • Seki, T.1    Bourgeault, S.T.2    Chareancholvanich, K.3    Lew, W.4
  • 24
    • 0032923984 scopus 로고    scopus 로고
    • The natural history of tibial radiolucent lines in a proximally cemented stemmed total knee arthroplasty
    • Smith S, Naima VS, Freeman MA (1999) The natural history of tibial radiolucent lines in a proximally cemented stemmed total knee arthroplasty. J Arthroplasty 14: 3-8.
    • (1999) J Arthroplasty , vol.14 , pp. 3-8
    • Smith, S.1    Naima, V.S.2    Freeman, M.A.3
  • 25
    • 0034979335 scopus 로고    scopus 로고
    • The effect of a tibial baseplate undersurface peripheral lip on cement penetration in total knee arthroplasty
    • Vertullo CJ, Davey JR (2001) The effect of a tibial baseplate undersurface peripheral lip on cement penetration in total knee arthroplasty. J Arthroplasty 4: 487-492.
    • (2001) J Arthroplasty , vol.4 , pp. 487-492
    • Vertullo, C.J.1    Davey, J.R.2
  • 26
    • 0021339420 scopus 로고
    • Control of cement penetration in total knee arthroplasty
    • Walker PS, Soudry M, Ewald FC et al (1984) Control of cement penetration in total knee arthroplasty. Clin Orthop Relat Res 185: 155-164.
    • (1984) Clin Orthop Relat Res , vol.185 , pp. 155-164
    • Walker, P.S.1    Soudry, M.2    Ewald, F.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.