메뉴 건너뛰기




Volumn 132, Issue 9, 2010, Pages

Design of a free-floating polycarbonate-urethane meniscal implant using finite element modeling and experimental validation

Author keywords

Cadaver; Computational model; Contact pressure; Knee injury; Meniscectomy; Prosthesis

Indexed keywords

CADAVER; COMPUTATIONAL MODEL; CONTACT PRESSURE; KNEE INJURY; MENISCECTOMIES; PROSTHESIS;

EID: 77956833658     PISSN: 01480731     EISSN: 15288951     Source Type: Journal    
DOI: 10.1115/1.4001892     Document Type: Article
Times cited : (68)

References (42)
  • 1
    • 0020802378 scopus 로고
    • In-Vitro Measurement of Static Pressure Distribution in Synovial Joints-Part I: Tibial Surface of the Knee
    • Ahmed, A. M., and Burke, D. L., 1983, "In-Vitro Measurement of Static Pressure Distribution in Synovial Joints-Part I: Tibial Surface of the Knee," ASME J. Biomech. Eng., 105, pp. 216-225.
    • (1983) ASME J. Biomech. Eng. , vol.105 , pp. 216-225
    • Ahmed, A.M.1    Burke, D.L.2
  • 2
    • 0018824102 scopus 로고
    • Load-Bearing Mode of the Knee Joint: Physical Behavior of the Knee Joint with or Without Menisci
    • Kurosawa, H., Fukubayashi, T., and Nakajima, H., 1980, "Load-Bearing Mode of the Knee Joint: Physical Behavior of the Knee Joint With or Without Menisci," Clin. Orthop. Relat. Res., 149, pp. 283-290.
    • (1980) Clin. Orthop. Relat. Res. , vol.149 , pp. 283-290
    • Kurosawa, H.1    Fukubayashi, T.2    Nakajima, H.3
  • 4
    • 0021733942 scopus 로고
    • Late Degenerative Changes after Meniscectomy. Factors Affecting the Knee after Operation
    • Allen, P. R., Denham, R. A., and Swan, A. V., 1984, "Late Degenerative Changes After Meniscectomy. Factors Affecting the Knee After Operation," J. Bone Jt. Surg., Br. Vol., 66, pp. 666-671.
    • (1984) J. Bone Jt. Surg., Br. , vol.66 , pp. 666-671
    • Allen, P.R.1    Denham, R.A.2    Swan, A.V.3
  • 5
    • 4444355792 scopus 로고    scopus 로고
    • Risk Factors for Symptomatic Knee Osteoarthritis Fifteen to Twenty-Two Years after Meniscectomy
    • Englund, M., and Lohmander, L. S., 2004, "Risk Factors for Symptomatic Knee Osteoarthritis Fifteen to Twenty-Two Years After Meniscectomy," Arthritis Rheum., 50, pp. 2811-2819.
    • (2004) Arthritis Rheum. , vol.50 , pp. 2811-2819
    • Englund, M.1    Lohmander, L.S.2
  • 6
    • 33845763931 scopus 로고    scopus 로고
    • The Consequences of Meniscectomy
    • McDermott, I. D., and Amis, A. A., 2006, "The Consequences of Meniscectomy," J. Bone Jt. Surg., Br. Vol., 88-B, pp. 1549-1556.
    • (2006) J. Bone Jt. Surg., Br. , vol.88 B , pp. 1549-1556
    • McDermott, I.D.1    Amis, A.A.2
  • 7
    • 0037342832 scopus 로고    scopus 로고
    • The Current State of Meniscal Allograft Transplantation and Replacement
    • Peters, G., and Wirth, C. J., 2003, "The Current State of Meniscal Allograft Transplantation and Replacement," Knee, 10, pp. 19-31.
    • (2003) Knee , vol.10 , pp. 19-31
    • Peters, G.1    Wirth, C.J.2
  • 8
    • 0024556281 scopus 로고
    • Homologous Meniscus Transplantation. Experimental and Clinical Results
    • Milachowski, K. A., Weismeier, K., and Wirth, C. J., 1989, "Homologous Meniscus Transplantation. Experimental and Clinical Results," Int. Orthop., 13, pp. 1-11.
    • (1989) Int. Orthop. , vol.13 , pp. 1-11
    • Milachowski, K.A.1    Weismeier, K.2    Wirth, C.J.3
  • 9
    • 3042738321 scopus 로고    scopus 로고
    • Meniscal Transplantation in Symptomatic Patients Less Than Fifty Years Old
    • Noyes, F. R., Barber-Westin, S. D., and Rankin, M., 2004, "Meniscal Transplantation in Symptomatic Patients Less Than Fifty Years Old," J. Bone Jt. Surg., Am. Vol., 86-A, pp. 1392-1404.
    • (2004) J. Bone Jt. Surg., Am. , vol.86 A , pp. 1392-1404
    • Noyes, F.R.1    Barber-Westin, S.D.2    Rankin, M.3
  • 10
    • 0036207205 scopus 로고    scopus 로고
    • Survival Analysis of Human Meniscal Transplantations
    • van Arkel, E. R., and de Boer, H. H., 2002, "Survival Analysis of Human Meniscal Transplantations," J. Bone Jt. Surg., Br. Vol., 84, pp. 227-231.
    • (2002) J. Bone Jt. Surg., Br. , vol.84 , pp. 227-231
    • Van Arkel, E.R.1    De Boer, H.H.2
  • 11
    • 0036518910 scopus 로고    scopus 로고
    • Joint Degeneration Following Meniscal Allograft Transplantation in a Canine Model: Mechanical Properties and Semiquantitative Histology of Articular Cartilage
    • Elliott, D. M., Jones, R., Setton, L. A., Scully, S. P., Vail, T. P., and Guilak, F., 2002, "Joint Degeneration Following Meniscal Allograft Transplantation in a Canine Model: Mechanical Properties and Semiquantitative Histology of Articular Cartilage," Knee Surg. Sports Traumatol. Arthrosc., 10, pp. 109-118.
    • (2002) Knee Surg. Sports Traumatol. Arthrosc. , vol.10 , pp. 109-118
    • Elliott, D.M.1    Jones, R.2    Setton, L.A.3    Scully, S.P.4    Vail, T.P.5    Guilak, F.6
  • 12
    • 2942706077 scopus 로고    scopus 로고
    • Medial Meniscus Extrusion on Knee MRI: Is Extent Associated with Severity of Degeneration or Type of Tear?
    • Costa, C. R., Morrison, W. B., and Carrino, J. A., 2004, "Medial Meniscus Extrusion on Knee MRI: Is Extent Associated With Severity of Degeneration or Type of Tear?," AJR, Am. J. Roentgenol., 183, pp. 17-23.
    • (2004) AJR, Am. J. Roentgenol. , vol.183 , pp. 17-23
    • Costa, C.R.1    Morrison, W.B.2    Carrino, J.A.3
  • 13
    • 0029278040 scopus 로고
    • Tensile Stress-Strain Characteristics of the Human Meniscal Material
    • Tissakht, M., and Ahmed, A. M., 1995, "Tensile Stress-Strain Characteristics of the Human Meniscal Material," J. Biomech., 28, pp. 411-422.
    • (1995) J. Biomech. , vol.28 , pp. 411-422
    • Tissakht, M.1    Ahmed, A.M.2
  • 14
    • 0037212118 scopus 로고    scopus 로고
    • How the Stiffness of Meniscal Attachments and the Meniscal Material Properties Affect Tibio-Femoral Contact Pressure Computed Using a Validated Finite Element Model of the Human Knee Joint
    • Haut Donahue, T. L., Hull, M. L., Rashid, M. M., and Jacobs, C. R., 2003, "How the Stiffness of Meniscal Attachments and the Meniscal Material Properties Affect Tibio-Femoral Contact Pressure Computed Using a Validated Finite Element Model of the Human Knee Joint," J. Biomech., 36, pp. 19-34.
    • (2003) J. Biomech. , vol.36 , pp. 19-34
    • Haut Donahue, T.L.1    Hull, M.L.2    Rashid, M.M.3    Jacobs, C.R.4
  • 15
    • 49049098658 scopus 로고    scopus 로고
    • Influence of Meniscectomy and Meniscus Replacement on the Stress Distribution in the Human Knee Joint
    • Vaziri, A., Nayeb Hashemi, H., Singh, A., and Tafti, B. A., 2008, "Influence of Meniscectomy and Meniscus Replacement on the Stress Distribution in the Human Knee Joint," Ann. Biomed. Eng., 36, pp. 1335-1344.
    • (2008) Ann. Biomed. Eng. , vol.36 , pp. 1335-1344
    • Vaziri, A.1    Nayeb Hashemi, H.2    Singh, A.3    Tafti, B.A.4
  • 19
    • 77952093573 scopus 로고    scopus 로고
    • Follow-Up of Collagen Meniscus Implant Patients: Clinical, Radiological, and Magnetic Resonance Imaging Results at 5 Years
    • Bulgheroni, P., Murena, L., Ratti, C., Bulgheroni, E., Ronga, M., and Cherubino, P., 2010, "Follow-Up of Collagen Meniscus Implant Patients: Clinical, Radiological, and Magnetic Resonance Imaging Results at 5 Years," Knee, 17(3), pp. 224-229.
    • (2010) Knee , vol.17 , Issue.3 , pp. 224-229
    • Bulgheroni, P.1    Murena, L.2    Ratti, C.3    Bulgheroni, E.4    Ronga, M.5    Cherubino, P.6
  • 20
    • 10644256645 scopus 로고    scopus 로고
    • Preliminary Study of Polyvinyl Alcohol-Hydrogel (PVA-H) Artificial Meniscus
    • Kobayashi, M., Toguchida, J., and Oka, M., 2005, "Preliminary Study of Polyvinyl Alcohol-Hydrogel (PVA-H) Artificial Meniscus," Biomaterials, 26(16), pp. 3243-3248.
    • (2005) Biomaterials , vol.26 , Issue.16 , pp. 3243-3248
    • Kobayashi, M.1    Toguchida, J.2    Oka, M.3
  • 22
    • 33748474432 scopus 로고    scopus 로고
    • Compliant Layer Acetabular Cups: Friction Testing of a Range of Materials and Designs for a New Generation of Prosthesis That Mimics the Natural Joint
    • Scholes, S. C., Burgess, I. C., Marsden, H. R., Unsworth, A., Jones, E., and Smith, N., 2006, "Compliant Layer Acetabular Cups: Friction Testing of a Range of Materials and Designs for a New Generation of Prosthesis That Mimics the Natural Joint," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 220, pp. 583-596.
    • (2006) Proc. Inst. Mech. Eng., Part H: J. Eng. Med. , vol.220 , pp. 583-596
    • Scholes, S.C.1    Burgess, I.C.2    Marsden, H.R.3    Unsworth, A.4    Jones, E.5    Smith, N.6
  • 23
    • 33751227824 scopus 로고    scopus 로고
    • Tribological Behavior of Thermoplastic Polyurethane Elastomers
    • Elleuch, R., Elleuch, K., Salah, B., and Zahouani, H., 2007, "Tribological Behavior of Thermoplastic Polyurethane Elastomers," Mater. Des., 28, pp. 824-830.
    • (2007) Mater. Des. , vol.28 , pp. 824-830
    • Elleuch, R.1    Elleuch, K.2    Salah, B.3    Zahouani, H.4
  • 24
    • 3342912102 scopus 로고    scopus 로고
    • Analysis and Evaluation of a Biomedical Polycarbonate Urethane Tested in an in Vitro Study and an Ovine Arthroplasty Model. Part II: In Vivo Investigation
    • Khan, I., Smith, N., Jones, E., Finch, D. S., and Cameron, R. E., 2005, "Analysis and Evaluation of a Biomedical Polycarbonate Urethane Tested in an In Vitro Study and an Ovine Arthroplasty Model. Part II: In Vivo Investigation," Biomaterials, 26, pp. 633-643.
    • (2005) Biomaterials , vol.26 , pp. 633-643
    • Khan, I.1    Smith, N.2    Jones, E.3    Finch, D.S.4    Cameron, R.E.5
  • 25
    • 0029347550 scopus 로고
    • Development and Validation of a Three-Dimensional Finite Element Model of the Pelvic Bone
    • Dalstra, M., Huiskes, R., and van Erning, L., 1995, "Development and Validation of a Three-Dimensional Finite Element Model of the Pelvic Bone," ASME J. Biomech. Eng., 117, pp. 272-278.
    • (1995) ASME J. Biomech. Eng. , vol.117 , pp. 272-278
    • Dalstra, M.1    Huiskes, R.2    Van Erning, L.3
  • 26
    • 0042755636 scopus 로고
    • A Theory of Large Elastic Deformation
    • Mooney, M., 1940, "A Theory of Large Elastic Deformation," J. Appl. Phys., 11, pp. 582-592.
    • (1940) J. Appl. Phys. , vol.11 , pp. 582-592
    • Mooney, M.1
  • 27
    • 0014698584 scopus 로고
    • The Mechanics of the Knee Joint in Relation to Normal Walking
    • Morrison, J. B., 1970, "The Mechanics of the Knee Joint in Relation to Normal Walking," J. Biomech., 3, pp. 51-61.
    • (1970) J. Biomech. , vol.3 , pp. 51-61
    • Morrison, J.B.1
  • 28
    • 33645701887 scopus 로고    scopus 로고
    • 3D Finite Element Model of Meniscectomy: Changes in Joint Contact Behavior
    • Zielinska, B., and Donahue, T. L., 2006, "3D Finite Element Model of Meniscectomy: Changes in Joint Contact Behavior," ASME J. Biomech. Eng., 128, pp. 115-123.
    • (2006) ASME J. Biomech. Eng. , vol.128 , pp. 115-123
    • Zielinska, B.1    Donahue, T.L.2
  • 29
    • 0036772176 scopus 로고    scopus 로고
    • Identification of Cross-Sectional Parameters of Lateral Meniscal Allografts That Predict Tibial Contact Pressure in Human Cadaveric Knees
    • Huang, A., Hull, M. L., Howell, S. M., and Haut Donahue, T. L., 2002, "Identification of Cross-Sectional Parameters of Lateral Meniscal Allografts That Predict Tibial Contact Pressure in Human Cadaveric Knees," ASME J. Biomech. Eng., 124, pp. 481-489.
    • (2002) ASME J. Biomech. Eng. , vol.124 , pp. 481-489
    • Huang, A.1    Hull, M.L.2    Howell, S.M.3    Haut Donahue, T.L.4
  • 30
    • 17044416416 scopus 로고    scopus 로고
    • Finite Element Analysis of the Effect of Meniscal Tears and Meniscectomies on Human Knee Biomechanics
    • Bristol, Avon
    • Pena, E., Calvo, B., Martinez, M. A., Palanca, D., and Doblare, M., 2005, "Finite Element Analysis of the Effect of Meniscal Tears and Meniscectomies on Human Knee Biomechanics," Clin. Biomech. (Bristol, Avon), 20, pp. 498-507.
    • (2005) Clin. Biomech. , vol.20 , pp. 498-507
    • Pena, E.1    Calvo, B.2    Martinez, M.A.3    Palanca, D.4    Doblare, M.5
  • 32
    • 0036260693 scopus 로고    scopus 로고
    • A Finite Element Model of the Human Knee Joint for the Study of Tibio-Femoral Contact
    • Haut Donahue, T. L., Hull, M. L., Rashid, M. M., and Jacobs, C. R., 2002, "A Finite Element Model of the Human Knee Joint for the Study of Tibio-Femoral Contact," ASME J. Biomech. Eng., 124, pp. 273-280.
    • (2002) ASME J. Biomech. Eng. , vol.124 , pp. 273-280
    • Haut Donahue, T.L.1    Hull, M.L.2    Rashid, M.M.3    Jacobs, C.R.4
  • 33
    • 34247099408 scopus 로고    scopus 로고
    • Assessment of Mechanical Conditions in Sub-Dermal Tissues during Sitting: A Combined Experimental-MRI and Finite Element Approach
    • Linder-Ganz, E., Shabshin, N., Itzchak, Y., and Gefen, A., 2007, "Assessment of Mechanical Conditions in Sub-Dermal Tissues During Sitting: A Combined Experimental-MRI and Finite Element Approach," J. Biomech., 40, pp. 1443-1454.
    • (2007) J. Biomech. , vol.40 , pp. 1443-1454
    • Linder-Ganz, E.1    Shabshin, N.2    Itzchak, Y.3    Gefen, A.4
  • 34
    • 77954670536 scopus 로고    scopus 로고
    • A Novel Quantitative Approach for Evaluating Contact Mechanics of Meniscal Replacements
    • Linder-Ganz, E., Elsner, J. J., Danino, A., Guilak, F., and Shterling, A., 2010, "A Novel Quantitative Approach for Evaluating Contact Mechanics of Meniscal Replacements," ASME J. Biomech. Eng., 132(2), p. 024501.
    • (2010) ASME J. Biomech. Eng. , vol.132 , Issue.2 , pp. 024501
    • Linder-Ganz, E.1    Elsner, J.J.2    Danino, A.3    Guilak, F.4    Shterling, A.5
  • 35
    • 77956797823 scopus 로고    scopus 로고
    • website
    • DSM/Dyneema website: http://www.dsm.com/en-US/html/hpf/home-dyneema.htm
  • 36
    • 44449121707 scopus 로고    scopus 로고
    • The Effects of Lateral Meniscal Allograft Transplantation Techniques on Tibio-Femoral Contact Pressures
    • McDermott, I. D., Lie, D. T., Edwards, A., Bull, A. M., and Amis, A. A., 2008, "The Effects of Lateral Meniscal Allograft Transplantation Techniques on Tibio-Femoral Contact Pressures," Knee Surg. Sports Traumatol. Arthrosc, 16, pp. 553-560.
    • (2008) Knee Surg. Sports Traumatol. Arthrosc , vol.16 , pp. 553-560
    • McDermott, I.D.1    Lie, D.T.2    Edwards, A.3    Bull, A.M.4    Amis, A.A.5
  • 37
    • 0037729071 scopus 로고    scopus 로고
    • The Level of Compressive Load Affects Conclusions from Statistical Analyses to Determine Whether a Lateral Meniscal Autograft Restores Tibial Contact Pressure to Normal: A Study in Human Cadaveric Knees
    • Huang, A., Hull, M. L., and Howell, S. M., 2003, "The Level of Compressive Load Affects Conclusions From Statistical Analyses to Determine Whether a Lateral Meniscal Autograft Restores Tibial Contact Pressure to Normal: A Study in Human Cadaveric Knees," J. Orthop. Res., 21, pp. 459-464.
    • (2003) J. Orthop. Res. , vol.21 , pp. 459-464
    • Huang, A.1    Hull, M.L.2    Howell, S.M.3
  • 38
    • 0037342117 scopus 로고    scopus 로고
    • Finite Element Analysis of the Meniscus: The Influence of Geometry and Material Properties on Its Behavior
    • Meakin, J. R., Shrive, N. G., Frank, C. B., and Hart, D. A., 2003, "Finite Element Analysis of the Meniscus: The Influence of Geometry and Material Properties on Its Behavior," Knee, 10, pp. 33-41.
    • (2003) Knee , vol.10 , pp. 33-41
    • Meakin, J.R.1    Shrive, N.G.2    Frank, C.B.3    Hart, D.A.4
  • 39
    • 0021803978 scopus 로고
    • Collagen Orientations in the Meniscus of the Knee Joint
    • Aspden, R. M., Yarker, Y. E., and Hukins, D. W., 1985, "Collagen Orientations in the Meniscus of the Knee Joint," J. Anat., 140, pp. 371-380.
    • (1985) J. Anat. , vol.140 , pp. 371-380
    • Aspden, R.M.1    Yarker, Y.E.2    Hukins, D.W.3
  • 40
    • 0032723805 scopus 로고    scopus 로고
    • The Instantaneous Compressive Modulus of Human Articular Cartilage in Joints of the Lower Limb
    • Shepherd, D. E., and Seedhom, B. B., 1999, "The Instantaneous Compressive Modulus of Human Articular Cartilage in Joints of the Lower Limb," Rheumatology, 38, pp. 124-132.
    • (1999) Rheumatology , vol.38 , pp. 124-132
    • Shepherd, D.E.1    Seedhom, B.B.2
  • 41
    • 77956856015 scopus 로고    scopus 로고
    • website
    • Dupont official website: www.dupont.com


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.