메뉴 건너뛰기




Volumn 10, Issue 1, 2003, Pages 33-41

Finite element analysis of the meniscus: The influence of geometry and material properties on its behaviour

Author keywords

Compression; Finite element analysis; Meniscus; Prostheses

Indexed keywords

ARTICLE; CARTILAGE; COMPRESSION; FEMUR; FINITE ELEMENT ANALYSIS; GEOMETRY; KNEE MENISCUS; KNEE PROSTHESIS; MATERIAL STATE; PRIORITY JOURNAL;

EID: 0037342117     PISSN: 09680160     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0968-0160(02)00106-0     Document Type: Article
Times cited : (82)

References (36)
  • 1
    • 0000887530 scopus 로고
    • The function of intra-articular fibro-cartilages, with special reference to the knee and inferior radio-ulnar joints
    • MacConaill M.A. The function of intra-articular fibro-cartilages, with special reference to the knee and inferior radio-ulnar joints. J Anat. 66:1932;210-227.
    • (1932) J Anat , vol.66 , pp. 210-227
    • MacConaill, M.A.1
  • 3
    • 13544255241 scopus 로고
    • Knee joint changes after meniscectomy
    • Fairbank T.J. Knee joint changes after meniscectomy. J Bone Jt Surg (Br). 30B:1948;664-670.
    • (1948) J Bone Jt Surg (Br) , vol.30 B , pp. 664-670
    • Fairbank, T.J.1
  • 4
    • 0001459926 scopus 로고
    • The function of the semilunar cartialges
    • King D. The function of the semilunar cartialges. J Bone Jt Surg. 18:1936;1069-1076.
    • (1936) J Bone Jt Surg , vol.18 , pp. 1069-1076
    • King, D.1
  • 5
    • 0025317334 scopus 로고
    • Changes in articular cartilage after meniscectomy
    • Lanzer W.L., Komenda G. Changes in articular cartilage after meniscectomy. Clin Orthop Rel Res. 252:1990;41-48.
    • (1990) Clin Orthop Rel Res , vol.252 , pp. 41-48
    • Lanzer, W.L.1    Komenda, G.2
  • 6
    • 0025361097 scopus 로고
    • Decision-making factors in the treatment of meniscus lesions
    • De Haven K.E. Decision-making factors in the treatment of meniscus lesions. Clin Orthop Rel Res. 252:1990;49-54.
    • (1990) Clin Orthop Rel Res , vol.252 , pp. 49-54
    • De Haven, K.E.1
  • 7
    • 0033628795 scopus 로고    scopus 로고
    • Biofix resorbable meniscus arrow for meniscal ruptures: Results of a 1-year follow-up
    • Hürel C., Mertens F., Verdonk R. Biofix resorbable meniscus arrow for meniscal ruptures: results of a 1-year follow-up. Knee Surg Sports Traumatol Arthrosc. 8:2000;46-52.
    • (2000) Knee Surg Sports Traumatol Arthrosc , vol.8 , pp. 46-52
    • Hürel, C.1    Mertens, F.2    Verdonk, R.3
  • 8
    • 0035353891 scopus 로고    scopus 로고
    • Biomechanical investigations of different meniscal repair implants in comparison with horizontal sutures on human meniscus
    • Becker R., Schroder M., Starke C., Urbach D., Nebelung W. Biomechanical investigations of different meniscal repair implants in comparison with horizontal sutures on human meniscus. Arthroscopy. 17:2001;439-444.
    • (2001) Arthroscopy , vol.17 , pp. 439-444
    • Becker, R.1    Schroder, M.2    Starke, C.3    Urbach, D.4    Nebelung, W.5
  • 9
    • 0027657483 scopus 로고
    • Prosthetic replacement of the rabbit medial meniscus
    • Messner K., Gillquist J. Prosthetic replacement of the rabbit medial meniscus. J Biomed Mat Res. 27:1993;1165-1173.
    • (1993) J Biomed Mat Res , vol.27 , pp. 1165-1173
    • Messner, K.1    Gillquist, J.2
  • 10
    • 0034580478 scopus 로고    scopus 로고
    • Solvent free fabrication of micro-porous polyurethane amide and polyurethane-urea scaffolds for repair and replacement of the knee-joint meniscus
    • Spaans C.J., Belgraves V.W., Rienstra O., deGroot J.H., Veth R.P.H., Pennings A.J. Solvent free fabrication of micro-porous polyurethane amide and polyurethane-urea scaffolds for repair and replacement of the knee-joint meniscus. Biomaterials. 21:2000;2453-2460.
    • (2000) Biomaterials , vol.21 , pp. 2453-2460
    • Spaans, C.J.1    Belgraves, V.W.2    Rienstra, O.3    DeGroot, J.H.4    Veth, R.P.H.5    Pennings, A.J.6
  • 12
    • 0032758947 scopus 로고    scopus 로고
    • A clinical study of collagen meniscus implants to restore the injured meniscus
    • Rodkey W.G., Steadman J.R., Li S.T. A clinical study of collagen meniscus implants to restore the injured meniscus. Clin Orthop Rel Res. 367S:1999;S281-S292.
    • (1999) Clin Orthop Rel Res , vol.367 S , pp. 281-S292
    • Rodkey, W.G.1    Steadman, J.R.2    Li, S.T.3
  • 14
    • 0025342069 scopus 로고
    • Meniscal replacement using a cryopreserved allograft: An experimental study in the dog
    • Arnoczky S.P., Warren R.F., McDevitt C.A. Meniscal replacement using a cryopreserved allograft: an experimental study in the dog. Clin Orthop Rel Res. 252:1990;121-128.
    • (1990) Clin Orthop Rel Res , vol.252 , pp. 121-128
    • Arnoczky, S.P.1    Warren, R.F.2    McDevitt, C.A.3
  • 15
    • 0026464929 scopus 로고
    • Medial meniscus replacement by a tendon autograft. Experiments in sheep
    • Kohn D., Wirth C.J., Reiss G., et al. Medial meniscus replacement by a tendon autograft. Experiments in sheep. J Bone Jt Surg (Br). 74B:1992;910-917.
    • (1992) J Bone Jt Surg (Br) , vol.74 B , pp. 910-917
    • Kohn, D.1    Wirth, C.J.2    Reiss, G.3
  • 16
    • 0034089377 scopus 로고    scopus 로고
    • Autogenous tendon graft substitution of absent knee joint meniscus: A pilot study
    • Johnson L.L., Feagin J.A. Autogenous tendon graft substitution of absent knee joint meniscus: a pilot study. Arthroscopy. 16:2000;191-196.
    • (2000) Arthroscopy , vol.16 , pp. 191-196
    • Johnson, L.L.1    Feagin, J.A.2
  • 17
    • 0021738730 scopus 로고
    • An axisymmetric finite element analysis of the mechanical function of the meniscus
    • Sauren A.A.H.J., Huson A., Schouten R.Y. An axisymmetric finite element analysis of the mechanical function of the meniscus. Int J Sports Med. 5:(Suppl.):1984;93-95.
    • (1984) Int J Sports Med , vol.5 , Issue.SUPPL. , pp. 93-95
    • Sauren, A.A.H.J.1    Huson, A.2    Schouten, R.Y.3
  • 18
    • 0022099117 scopus 로고
    • A model for the function and failure of the meniscus
    • Aspden R.M. A model for the function and failure of the meniscus. Eng Med. 14:1985;119-122.
    • (1985) Eng Med , vol.14 , pp. 119-122
    • Aspden, R.M.1
  • 21
    • 0025081712 scopus 로고
    • A numerical model of the load transmission in the tibio-femoral contact area
    • Schreppers G.J.M.A., Sauren A.A.H.J., Huson A. A numerical model of the load transmission in the tibio-femoral contact area. Proc Inst Mech Eng (H). 204:1990;53-59.
    • (1990) Proc Inst Mech Eng (H) , vol.204 , pp. 53-59
    • Schreppers, G.J.M.A.1    Sauren, A.A.H.J.2    Huson, A.3
  • 22
    • 0026928514 scopus 로고
    • A transversely isotropic biphasic finite element model of the meniscus
    • Spilker R.L., Donzelli P.S., Mow V.C. A transversely isotropic biphasic finite element model of the meniscus. J Biomech. 25:1992;1027-1045.
    • (1992) J Biomech , vol.25 , pp. 1027-1045
    • Spilker, R.L.1    Donzelli, P.S.2    Mow, V.C.3
  • 23
    • 0036348012 scopus 로고    scopus 로고
    • Statistical methods in finite element analysis
    • Dar F.H., Meakin J.R., Aspden R.M. Statistical methods in finite element analysis. J Biomech. 35:2002;1155-1161.
    • (2002) J Biomech , vol.35 , pp. 1155-1161
    • Dar, F.H.1    Meakin, J.R.2    Aspden, R.M.3
  • 24
    • 0027733556 scopus 로고
    • Parametric modelling of a knee joint prosthesis
    • Khoo L.P., Goh J.C.H., Chow S.L. Parametric modelling of a knee joint prosthesis. Proc Inst Mech Eng (H). 207:1993;115-120.
    • (1993) Proc Inst Mech Eng (H) , vol.207 , pp. 115-120
    • Khoo, L.P.1    Goh, J.C.H.2    Chow, S.L.3
  • 25
    • 0021803978 scopus 로고
    • Collagen orientations in the meniscus of the knee joint
    • Aspden R.M., Yarker Y.E., Hukins D.W.L. Collagen orientations in the meniscus of the knee joint. J Anat. 140:1985;371-380.
    • (1985) J Anat , vol.140 , pp. 371-380
    • Aspden, R.M.1    Yarker, Y.E.2    Hukins, D.W.L.3
  • 26
    • 0031980603 scopus 로고    scopus 로고
    • Collagenous fibril texture of the human knee joint menisci
    • Peterson W., Tillman B. Collagenous fibril texture of the human knee joint menisci. Anat Embryol. 197:1998;317-324.
    • (1998) Anat Embryol , vol.197 , pp. 317-324
    • Peterson, W.1    Tillman, B.2
  • 27
    • 0031170946 scopus 로고    scopus 로고
    • Methodology and apparatus to determine material properties of the knee joint meniscus
    • Goertzen D.J., Budney D.R., Cinats J.G. Methodology and apparatus to determine material properties of the knee joint meniscus. Med Eng Phys. 19:1997;412-419.
    • (1997) Med Eng Phys , vol.19 , pp. 412-419
    • Goertzen, D.J.1    Budney, D.R.2    Cinats, J.G.3
  • 28
    • 0030623595 scopus 로고    scopus 로고
    • A technique for measuring the compressive modulus of articular cartilage under physiological loading rates with preliminary results
    • Shepherd D.E.T., Seedhom B.B. A technique for measuring the compressive modulus of articular cartilage under physiological loading rates with preliminary results. Proc Inst Mech Eng (H). 211:1997;155-163.
    • (1997) Proc Inst Mech Eng (H) , vol.211 , pp. 155-163
    • Shepherd, D.E.T.1    Seedhom, B.B.2
  • 30
    • 0027626509 scopus 로고
    • Stresses at the meniscofemoral joint: Elastostatic investigations of the applicability of interface elements
    • Lengsfeld M. Stresses at the meniscofemoral joint: elastostatic investigations of the applicability of interface elements. J Biomed Eng. 15:1993;324-328.
    • (1993) J Biomed Eng , vol.15 , pp. 324-328
    • Lengsfeld, M.1
  • 32
    • 0001802929 scopus 로고    scopus 로고
    • Common rookie mistakes - Under-meshed, under-converged models
    • Adams V. Common rookie mistakes - under-meshed, under-converged models. Benchmark. April:1999;8-13.
    • (1999) Benchmark , vol.APRIL , pp. 8-13
    • Adams, V.1
  • 35
    • 0032923007 scopus 로고    scopus 로고
    • Modelling of location- and time-dependent deformation of chondrocytes during cartilage loading
    • Wu J.Z., Herzog W., Epstein M. Modelling of location- and time-dependent deformation of chondrocytes during cartilage loading. J Biomech. 32:1999;563-572.
    • (1999) J Biomech , vol.32 , pp. 563-572
    • Wu, J.Z.1    Herzog, W.2    Epstein, M.3
  • 36
    • 0034103799 scopus 로고    scopus 로고
    • Use of roentgenography and magnetic resonance imaging to predict meniscal geometry determined with a three-dimensional coordinate digitising system
    • Haut T.L., Hull M.L., Howell S.M. Use of roentgenography and magnetic resonance imaging to predict meniscal geometry determined with a three-dimensional coordinate digitising system. J Orthop Res. 18:2000;228-237.
    • (2000) J Orthop Res , vol.18 , pp. 228-237
    • Haut, T.L.1    Hull, M.L.2    Howell, S.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.