메뉴 건너뛰기




Volumn 78, Issue 5, 2010, Pages 348-356

Multiparameter flow cytometry for the diagnosis and monitoring of small GPI-deficient cellular populations

Author keywords

BMT; FLAER; Flow cytometry; PNH; Sensitivity; Specificity

Indexed keywords

CD14 ANTIGEN; CD16 ANTIGEN; CD59 ANTIGEN; DECAY ACCELERATING FACTOR; GLYCOSYLPHOSPHATIDYLINOSITOL; AEROLYSIN; BACTERIAL TOXIN; BIOLOGICAL MARKER; CD59 PROTEIN, HUMAN; FC RECEPTOR; FCGR3B PROTEIN, HUMAN; FLUORESCENT DYE; GLYCOSYLPHOSPHATIDYLINOSITOL ANCHORED PROTEIN; PORE FORMING CYTOTOXIC PROTEIN; CELL MARKER; CYCLOSPORIN; FLUORESCENT AEROLYSIN; MERCAPTOPURINE; MYCOPHENOLIC ACID; THYMOCYTE ANTIBODY; UNCLASSIFIED DRUG;

EID: 77956578040     PISSN: 15524949     EISSN: 15524957     Source Type: Journal    
DOI: 10.1002/cyto.b.20519     Document Type: Article
Times cited : (25)

References (21)
  • 1
    • 0000037147 scopus 로고
    • Studies on destruction of red blood cells. Ii. Chronic hemolytic anemia with paroxysmal nocturnal hemoglobinuria: Certain immunological aspects of the hemolytic mechanism with special reference to serum complement
    • Ham TH, Dingle JH. Studies on destruction of red blood cells. Ii. Chronic hemolytic anemia with paroxysmal nocturnal hemoglobinuria: Certain immunological aspects of the hemolytic mechanism with special reference to serum complement. J Clin Invest 1939;18:657-672.
    • (1939) J Clin Invest , vol.18 , pp. 657-672
    • Ham, T.H.1    Dingle, J.H.2
  • 2
    • 0029981029 scopus 로고    scopus 로고
    • The use of monoclonal antibodies and flow cytometry in the diagnosis of paroxysmal nocturnal hemoglobinuria
    • Hall SE, Rosse WF. The use of monoclonal antibodies and flow cytometry in the diagnosis of paroxysmal nocturnal hemoglobinuria. Blood 1996;87:5332-5340.
    • (1996) Blood , vol.87 , pp. 5332-5340
    • Hall, S.E.1    Rosse, W.F.2
  • 3
    • 0023784162 scopus 로고
    • Different distribution of decay-accelerating factor on hematopoietic progenitors from normal individuals and patients with paroxysmal nocturnal hemoglobinuria
    • Kanamaru A, Okuda K, Ueda E, Kitani T, Kinoshita T, Nagai K. Different distribution of decay-accelerating factor on hematopoietic progenitors from normal individuals and patients with paroxysmal nocturnal hemoglobinuria. Blood 1988;72:507-511.
    • (1988) Blood , vol.72 , pp. 507-511
    • Kanamaru, A.1    Okuda, K.2    Ueda, E.3    Kitani, T.4    Kinoshita, T.5    Nagai, K.6
  • 5
    • 0025202564 scopus 로고
    • Deficiency of glycosyl-phosphatidylinositol-linked membrane glycoproteins of leukocytes in paroxysmal nocturnal hemoglobinuria, description of a new diagnostic cyto-fluorometric assay
    • van der Schoot CE, Huizinga TW, van't Veer-Korthof ET, Wijmans R, Pinkster J, von dem Borne AE. Deficiency of glycosyl-phosphatidylinositol-linked membrane glycoproteins of leukocytes in paroxysmal nocturnal hemoglobinuria, description of a new diagnostic cyto-fluorometric assay. Blood 1990;76:1853-1859.
    • (1990) Blood , vol.76 , pp. 1853-1859
    • Van Der Schoot, C.E.1    Huizinga, T.W.2    Van't Veer-Korthof, E.T.3    Wijmans, R.4    Pinkster, J.5    Von Dem Borne, A.E.6
  • 6
    • 0031936213 scopus 로고    scopus 로고
    • Glycosylphosphatidylinositol anchors of membrane glycoproteins are binding determinants for the channel-forming toxin aerolysin
    • Diep DB, Nelson KL, Raja SM, Pleshak EN, Buckley JT. Glycosylphosphatidylinositol anchors of membrane glycoproteins are binding determinants for the channel-forming toxin aerolysin. J Biol Chem 1998;273:2355-2360.
    • (1998) J Biol Chem , vol.273 , pp. 2355-2360
    • Diep, D.B.1    Nelson, K.L.2    Raja, S.M.3    Pleshak, E.N.4    Buckley, J.T.5
  • 8
    • 0033105696 scopus 로고    scopus 로고
    • Resistance of paroxysmal nocturnal hemoglobinuria cells to the glycosylphosphatidylinositol-binding toxin aerolysin
    • Brodsky RA, Mukhina GL, Nelson KL, Lawrence TS, Jones RJ, Buckley JT. Resistance of paroxysmal nocturnal hemoglobinuria cells to the glycosylphosphatidylinositol-binding toxin aerolysin. Blood 1999;93:1749-1756.
    • (1999) Blood , vol.93 , pp. 1749-1756
    • Brodsky, R.A.1    Mukhina, G.L.2    Nelson, K.L.3    Lawrence, T.S.4    Jones, R.J.5    Buckley, J.T.6
  • 10
    • 0037096414 scopus 로고    scopus 로고
    • Comparative analysis of different flow cytometry-based immunophenotypic methods for the analysis of CD59 and CD55 expression on major peripheral blood cell subsets
    • Hernandez-Campo PM, Martin-Ayuso M, Almeida J, Lopez A, Orfao A. Comparative analysis of different flow cytometry-based immunophenotypic methods for the analysis of CD59 and CD55 expression on major peripheral blood cell subsets. Cytometry 2002;50:191-201.
    • (2002) Cytometry , vol.50 , pp. 191-201
    • Hernandez-Campo, P.M.1    Martin-Ayuso, M.2    Almeida, J.3    Lopez, A.4    Orfao, A.5
  • 12
    • 9644276717 scopus 로고    scopus 로고
    • Selecting fluorochrome conjugates for maximum sensitivity
    • Maecker HT, Frey T, Nomura LE, Trotter J. Selecting fluorochrome conjugates for maximum sensitivity. Cytometry A 2004;62A:169-173.
    • (2004) Cytometry A , vol.62 A , pp. 169-173
    • Maecker, H.T.1    Frey, T.2    Nomura, L.E.3    Trotter, J.4
  • 13
    • 24744464140 scopus 로고    scopus 로고
    • Clinical evaluation of an aerolysin-based screening test for paroxysmal nocturnal haemoglobinuria
    • Peghini PE, Fehr J. Clinical evaluation of an aerolysin-based screening test for paroxysmal nocturnal haemoglobinuria. Cytometry B Clin Cyt 2005;67B:13-18.
    • (2005) Cytometry B Clin Cyt , vol.67 B , pp. 13-18
    • Peghini, P.E.1    Fehr, J.2
  • 14
    • 58149090759 scopus 로고    scopus 로고
    • Predicting response to immunosuppressive therapy and survival in severe aplastic anaemia
    • Scheinberg P, Wu CO, Nunez O, Young NS. Predicting response to immunosuppressive therapy and survival in severe aplastic anaemia. Br J Haematol 2009;144:206-216.
    • (2009) Br J Haematol , vol.144 , pp. 206-216
    • Scheinberg, P.1    Wu, C.O.2    Nunez, O.3    Young, N.S.4
  • 15
    • 33748429445 scopus 로고    scopus 로고
    • Clinical significance of a small population of paroxysmal nocturnal hemoglobinuria-type cells in the management of bone marrow failure
    • Nakao S, Sugimori C, Yamazaki H. Clinical significance of a small population of paroxysmal nocturnal hemoglobinuria-type cells in the management of bone marrow failure. Int J Hematol 2006;84: 118-122.
    • (2006) Int J Hematol , vol.84 , pp. 118-122
    • Nakao, S.1    Sugimori, C.2    Yamazaki, H.3
  • 16
    • 32644434385 scopus 로고    scopus 로고
    • Minor population of CD55-CD59-blood cells predicts response to immunosuppressive therapy and prognosis in patients with aplastic anemia
    • Sugimori C, Chuhjo T, Feng X, Yamazaki H, Takami A, Teramura M, Mizoguchi H, Omine M, Nakao S. Minor population of CD55-CD59-blood cells predicts response to immunosuppressive therapy and prognosis in patients with aplastic anemia. Blood 2006;107:1308-1314.
    • (2006) Blood , vol.107 , pp. 1308-1314
    • Sugimori, C.1    Chuhjo, T.2    Feng, X.3    Yamazaki, H.4    Takami, A.5    Teramura, M.6    Mizoguchi, H.7    Omine, M.8    Nakao, S.9
  • 17
    • 0028102953 scopus 로고
    • Soluble CD4, soluble CD8, soluble CD25, lymphopoieitic recovery, and endogenous cytokines after high-dose chemotherapy and blood stem cell transplantation
    • Ho AD, Maruyama M, Maghazachi A, Mason JR, Gluck S, Corringham RE. Soluble CD4, soluble CD8, soluble CD25, lymphopoieitic recovery, and endogenous cytokines after high-dose chemotherapy and blood stem cell transplantation. Blood 1994;84:3550-3557.
    • (1994) Blood , vol.84 , pp. 3550-3557
    • Ho, A.D.1    Maruyama, M.2    Maghazachi, A.3    Mason, J.R.4    Gluck, S.5    Corringham, R.E.6
  • 19
    • 23044435252 scopus 로고    scopus 로고
    • Four-color flow cytometry shows strong concordance with bone marrow morphology and cytogenetics in the evaluation for myelodysplasia
    • Kussick SJ, Fromm JR, Rossini A, Li Y, Chang A, Norwood TH, Wood BL. Four-color flow cytometry shows strong concordance with bone marrow morphology and cytogenetics in the evaluation for myelodysplasia. Am J Clin Pathol 2005;124:170-181.
    • (2005) Am J Clin Pathol , vol.124 , pp. 170-181
    • Kussick, S.J.1    Fromm, J.R.2    Rossini, A.3    Li, Y.4    Chang, A.5    Norwood, T.H.6    Wood, B.L.7
  • 20
    • 62349130455 scopus 로고    scopus 로고
    • Development and evaluation of a stabilized whole-blood preparation as a process control material for screening of paroxysmal nocturnal hemoglobinuria by flow cytometry
    • Richards SJ, Whitby L, Cullen MJ, Dickinson AJ, Granger V, Reilly JT, Hillmen P, Barnett D. Development and evaluation of a stabilized whole-blood preparation as a process control material for screening of paroxysmal nocturnal hemoglobinuria by flow cytometry. Cytometry B Clin Cyto 2008;76B:47-55.
    • (2008) Cytometry B Clin Cyto , vol.76 B , pp. 47-55
    • Richards, S.J.1    Whitby, L.2    Cullen, M.J.3    Dickinson, A.J.4    Granger, V.5    Reilly, J.T.6    Hillmen, P.7    Barnett, D.8
  • 21
    • 0033836378 scopus 로고    scopus 로고
    • Application of flow cytometry to the diagnosis of paroxysmal nocturnal hemoglobinuria
    • Richards SJ, Rawstron AC, Hillmen P. Application of flow cytometry to the diagnosis of paroxysmal nocturnal hemoglobinuria. Cytometry 2000;42:223-233.
    • (2000) Cytometry , vol.42 , pp. 223-233
    • Richards, S.J.1    Rawstron, A.C.2    Hillmen, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.