-
1
-
-
0029129056
-
Instrumentation of the cervicothoracic junction after destabilization
-
Bueff HU, Lotz JC, Colliou OK, et al. Instrumentation of the cervicothoracic junction after destabilization. Spine 1995;20:1789-1792
-
(1995)
Spine
, vol.20
, pp. 1789-1792
-
-
Bueff, H.U.1
Lotz, J.C.2
Colliou, O.K.3
-
2
-
-
0030006266
-
Posterior instrumentation of the unstable cervicothoracic spine
-
Chapman JR, Anderson PA, Pepin C, et al. Posterior instrumentation of the unstable cervicothoracic spine. J Neurosurg 1996;84:552-558
-
(1996)
J Neurosurg
, vol.84
, pp. 552-558
-
-
Chapman, J.R.1
Anderson, P.A.2
Pepin, C.3
-
3
-
-
0036596641
-
Managing disorders of the cervicothoracic junction
-
Daffner SD, Vaccaro AR. Managing disorders of the cervicothoracic junction. Am J Orthop 2002;31:323-327
-
(2002)
Am J Orthop
, vol.31
, pp. 323-327
-
-
Daffner, S.D.1
Vaccaro, A.R.2
-
4
-
-
33747361290
-
Neurological and functional outcome after unstable cervicothoracic junction injury treated by posterior reduction and synthesis
-
Lenoir T, Hoffmann E, Thevenin-Lemoine C, et al. Neurological and functional outcome after unstable cervicothoracic junction injury treated by posterior reduction and synthesis. Spine J 2006;6:507-513
-
(2006)
Spine J
, vol.6
, pp. 507-513
-
-
Lenoir, T.1
Hoffmann, E.2
Thevenin-Lemoine, C.3
-
5
-
-
2542503391
-
Posterior cervicothoracic instrumentation in spine tumors
-
Mazel C, Hoffmann E, Antonietti P, et al. Posterior cervicothoracic instrumentation in spine tumors. Spine 2004;29:1246-1253
-
(2004)
Spine
, vol.29
, pp. 1246-1253
-
-
Mazel, C.1
Hoffmann, E.2
Antonietti, P.3
-
6
-
-
52449129596
-
Posterior stabilization strategies following resection of cervicothoracic junction tumors: Review of 90 consecutive cases
-
Placantonakis DG, Laufer I, Wang JC, et al. Posterior stabilization strategies following resection of cervicothoracic junction tumors: review of 90 consecutive cases. J Neurosurg Spine 2008;9:111-119
-
(2008)
J Neurosurg Spine
, vol.9
, pp. 111-119
-
-
Placantonakis, D.G.1
Laufer, I.2
Wang, J.C.3
-
7
-
-
0032775942
-
Operative treatment of unstable injuries of the cervicothoracic junction
-
Sapkas G, Papadakis S, Katonis P, et al. Operative treatment of unstable injuries of the cervicothoracic junction. Eur Spine J 1999;8:279-283
-
(1999)
Eur Spine J
, vol.8
, pp. 279-283
-
-
Sapkas, G.1
Papadakis, S.2
Katonis, P.3
-
8
-
-
33646459999
-
Regional instability following cer-vicothoracic junction surgery
-
Steinmetz MP, Miller J, Warbel A, et al. Regional instability following cer-vicothoracic junction surgery. J Neurosurg Spine 2006;4:278-284
-
(2006)
J Neurosurg Spine
, vol.4
, pp. 278-284
-
-
Steinmetz, M.P.1
Miller, J.2
Warbel, A.3
-
9
-
-
22144494143
-
Biomechanics of stabilization after cervicothoracic compression-flexion injury
-
Ames CP, Bozkus MH, Chamberlain RH, et al. Biomechanics of stabilization after cervicothoracic compression-flexion injury. Spine 2005;30:1505-1512
-
(2005)
Spine
, vol.30
, pp. 1505-1512
-
-
Ames, C.P.1
Bozkus, M.H.2
Chamberlain, R.H.3
-
10
-
-
0033119287
-
Pedicle and transverse process screws of the upper thoracic spine
-
Heller JG, Shuster JK, Hutton WC. Pedicle and transverse process screws of the upper thoracic spine. Spine 1999;24:654-658
-
(1999)
Spine
, vol.24
, pp. 654-658
-
-
Heller, J.G.1
Shuster, J.K.2
Hutton, W.C.3
-
11
-
-
0037115173
-
Posterior stabilization at the cervi-cothoracic junction: A biomechanical study
-
Kreshak JL, Kim DH, Lindsey DP, et al. Posterior stabilization at the cervi-cothoracic junction: a biomechanical study. Spine 2002;27:2763-2770
-
(2002)
Spine
, vol.27
, pp. 2763-2770
-
-
Kreshak, J.L.1
Kim, D.H.2
Lindsey, D.P.3
-
13
-
-
33645524938
-
A comparison of pedicle and lateral mass screw construct stiffness at the cervicothoracic junction: A bio-mechanical study
-
Rhee JM, Kraiwattanapong C, Hutton WC. A comparison of pedicle and lateral mass screw construct stiffness at the cervicothoracic junction: a bio-mechanical study. Spine 2005;30:E636-40.
-
(2005)
Spine
, vol.30
-
-
Rhee, J.M.1
Kraiwattanapong, C.2
Hutton, W.C.3
-
14
-
-
0028102711
-
Morphometric evaluation of the cervico-thoracic junction: Practical considerations for posterior fixation of the spine
-
Stanescu S, Ebraheim NA, Yeasting RA, et al. Morphometric evaluation of the cervico-thoracic junction: practical considerations for posterior fixation of the spine. Spine 1994;19:2082-2088
-
(1994)
Spine
, vol.19
, pp. 2082-2088
-
-
Stanescu, S.1
Ebraheim, N.A.2
Yeasting, R.A.3
-
15
-
-
0034465541
-
A plate-rod device for treatment of cervicothoracic disorders: Comparison of mechanical testing with established cervical spine in vitro load testing data
-
Vaccaro AR, Conant RF, Hilibrand AS, et al. A plate-rod device for treatment of cervicothoracic disorders: comparison of mechanical testing with established cervical spine in vitro load testing data. J Spinal Disord 2000;13:350-355
-
(2000)
J Spinal Disord
, vol.13
, pp. 350-355
-
-
Vaccaro, A.R.1
Conant, R.F.2
Hilibrand, A.S.3
-
16
-
-
0026044673
-
Anatomic considerations for plate-screw fixation of the cervical spine
-
An HS, Gordon R, Renner K. Anatomic considerations for plate-screw fixation of the cervical spine. Spine 1991;16(suppl 10):S548-51.
-
(1991)
Spine
, vol.16
, Issue.SUPPL. 10
-
-
An, H.S.1
Gordon, R.2
Renner, K.3
-
17
-
-
34447271766
-
Pedicle screw fixation (T1,T2, andT3)
-
Daubs MD, Kim YJ,Lenke LG. Pedicle screw fixation (T1,T2, andT3). Instr Course Lect 2007;56:247-255
-
(2007)
Instr Course Lect
, vol.56
, pp. 247-255
-
-
Daubs, M.D.1
Kim Yjlenke, L.G.2
-
18
-
-
27944456047
-
Pedicle screw fixation of the thoracic spine: An in vitro biomechanical study on different configurations
-
Deviren V, Acaroglu E, Lee J, et al. Pedicle screw fixation of the thoracic spine: an in vitro biomechanical study on different configurations. Spine 2005;30:2530-2537
-
(2005)
Spine
, vol.30
, pp. 2530-2537
-
-
Deviren, V.1
Acaroglu, E.2
Lee, J.3
-
19
-
-
0031417450
-
Anatomic relations of the thoracic pedicle to the adjacent neural structures
-
DOI 10.1097/00007632-199707150-00002
-
Ebraheim NA, Jabaly G, Xu R, et al. Anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine 1997;22:1553-1557 (Pubitemid 28112825)
-
(1997)
Spine
, vol.22
, Issue.14
, pp. 1553-1557
-
-
Ebraheim, N.A.1
Jabaly, G.2
Xu, R.3
Yeasting, R.A.4
-
20
-
-
0035023036
-
Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine
-
Liljenqvist U, Hackenberg L, Link T, et al. Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine. Acta Orthop Belg 2001;67:157-163
-
(2001)
Acta Orthop Belg
, vol.67
, pp. 157-163
-
-
Liljenqvist, U.1
Hackenberg, L.2
Link, T.3
-
21
-
-
0026006202
-
Thoracic human vertebrae: Quantitative three-dimensional anatomy
-
Panjabi MM, Takata K, Goel V, et al. Thoracic human vertebrae: quantitative three-dimensional anatomy. Spine 1991;16:888-901.
-
(1991)
Spine
, vol.16
, pp. 888-901
-
-
Panjabi, M.M.1
Takata, K.2
Goel, V.3
-
22
-
-
1442277695
-
Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine
-
Richter M, Mattes T, Cakir B. Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine. Eur Spine J 2004;13:50-59
-
(2004)
Eur Spine J
, vol.13
, pp. 50-59
-
-
Richter, M.1
Mattes, T.2
Cakir, B.3
-
23
-
-
0035101506
-
Thoracic pedicle: Surgical anatomic evaluation and relations
-
Ugur HC, Attar A, Uz A, et al. Thoracic pedicle: surgical anatomic evaluation and relations. J Spinal Disord 2001;14:39-45. (Pubitemid 32162831)
-
(2001)
Journal of Spinal Disorders
, vol.14
, Issue.1
, pp. 39-45
-
-
Ugur, H.C.1
Attar, A.2
Uz, A.3
Tekdemir, I.4
Egemen, N.5
Genc, Y.6
-
24
-
-
0037114952
-
The treatment of unstable thoracic spine fractures with transpedicular screw instrumentation: A 3-year consecutive series
-
Yue JJ, Sossan A, Selgrath C, et al. The treatment of unstable thoracic spine fractures with transpedicular screw instrumentation: a 3-year consecutive series. Spine 2002;27:2782-2787
-
(2002)
Spine
, vol.27
, pp. 2782-2787
-
-
Yue, J.J.1
Sossan, A.2
Selgrath, C.3
-
25
-
-
63649085985
-
Correlation between computed tomography measurements and direct anatomic measurements of the axis for consideration of C2 laminar screw placement
-
Dean CL, Lee MJ, Robbin M, et al. Correlation between computed tomography measurements and direct anatomic measurements of the axis for consideration of C2 laminar screw placement. Spine J 2009;9:258-262
-
(2009)
Spine J
, vol.9
, pp. 258-262
-
-
Dean, C.L.1
Lee, M.J.2
Robbin, M.3
-
27
-
-
33745784887
-
C2 crossing laminar screws: Cadaveric morphometric analysis
-
Wang MY. C2 crossing laminar screws: cadaveric morphometric analysis. Operat Neurosurg 2006;59:ONS-84-ONS-88.
-
(2006)
Operat Neurosurg
, vol.59
-
-
Wang, M.Y.1
-
28
-
-
37349021761
-
Cervical crossing laminar screws: Early clinical results and complications
-
Wang MY. Cervical crossing laminar screws: early clinical results and complications. Operat Neurosurg 2007;61:ONS311-ONS6.
-
(2007)
Operat Neurosurg
, vol.61
-
-
Wang, M.Y.1
-
29
-
-
1842686189
-
Posterior C2 fixation using bilateral, crossing C2 laminar screws
-
Wright NM. Posterior C2 fixation using bilateral, crossing C2 laminar screws. J Spinal Disord Tech 2004;17:158-162
-
(2004)
J Spinal Disord Tech
, vol.17
, pp. 158-162
-
-
Wright, N.M.1
-
30
-
-
32944464250
-
Translaminar rigid screw fixation of the axis: Technical note
-
Wright NM. Translaminar rigid screw fixation of the axis: technical note. J Neurosurg Spine 2005;3:409-414
-
(2005)
J Neurosurg Spine
, vol.3
, pp. 409-414
-
-
Wright, N.M.1
-
31
-
-
67649872401
-
Use of axial and subaxial translaminar screw fixation in the management of upper cervical spinal instability in a series of 7 children
-
Chamoun RB, Relyea KM, Johnson KK, et al. Use of axial and subaxial translaminar screw fixation in the management of upper cervical spinal instability in a series of 7 children. Neurosurgery 2009;64:734-739
-
(2009)
Neurosurgery
, vol.64
, pp. 734-739
-
-
Chamoun, R.B.1
Relyea, K.M.2
Johnson, K.K.3
-
32
-
-
58149125330
-
Significance of laminar screw fixation in the subaxial cervical spine
-
Hong JT, Sung JH, Son BC, et al. Significance of laminar screw fixation in the subaxial cervical spine. Spine 2008;33:1739-1743
-
(2008)
Spine
, vol.33
, pp. 1739-1743
-
-
Hong, J.T.1
Sung, J.H.2
Son, B.C.3
-
33
-
-
34548269916
-
Translaminar screw fixation in the upper thoracic spine
-
Kretzer RM, Sciubba DM, Bagley CA, et al. Translaminar screw fixation in the upper thoracic spine. J Neurosurg Spine 2006;5:527-533
-
(2006)
J Neurosurg Spine
, vol.5
, pp. 527-533
-
-
Kretzer, R.M.1
Sciubba, D.M.2
Bagley, C.A.3
-
34
-
-
67649403871
-
Intralaminr screw insertion of thoracic spine in children with severe spinal deformities: Two case reports
-
Lewis SJ, Canavese F, Keetbaas S. Intralaminr screw insertion of thoracic spine in children with severe spinal deformities: two case reports. Spine 2009;34:E251-4.
-
(2009)
Spine
, vol.34
-
-
Lewis, S.J.1
Canavese, F.2
Keetbaas, S.3
-
35
-
-
67049143144
-
Thoracic and lumbar laminoplasty using a translaminar screw: Morphometric study and technique
-
Park SB, Jahng T-A, Kim CH, et al. Thoracic and lumbar laminoplasty using a translaminar screw: morphometric study and technique. J Neurosurg Spine 2009;10:603-609
-
(2009)
J Neurosurg Spine
, vol.10
, pp. 603-609
-
-
Park, S.B.1
Jahng, T.-A.2
Kim, C.H.3
-
36
-
-
58949096359
-
Computed tomography and biomechanical evaluation of screw fixation options at the cervicothoracic junction: Intralamina versus intrapedicular techniques
-
Cardoso MJ, Dmitriev AE, Lehman RA, et al. Computed tomography and biomechanical evaluation of screw fixation options at the cervicothoracic junction: intralamina versus intrapedicular techniques. Spine 2008;33:2612-2617
-
(2008)
Spine
, vol.33
, pp. 2612-2617
-
-
Cardoso, M.J.1
Dmitriev, A.E.2
Lehman, R.A.3
-
37
-
-
35848942147
-
Atlantoaxial fusion: A biomechani-cal analysis of two C1-C2 fusion techniques
-
Claybrooks R, Kayanja M, Milks R, et al. Atlantoaxial fusion: a biomechani-cal analysis of two C1-C2 fusion techniques. Spine J 2007;7:682-688
-
(2007)
Spine J
, vol.7
, pp. 682-688
-
-
Claybrooks, R.1
Kayanja, M.2
Milks, R.3
-
38
-
-
55249125685
-
The cervical end of an occipitocer-vical fusion: A biomechanical evaluation of 3 constructs
-
Finn MA, Fassett DR, McCall TD, et al. The cervical end of an occipitocer-vical fusion: a biomechanical evaluation of 3 constructs. J Neurosurg Spine 2008;9:296-300.
-
(2008)
J Neurosurg Spine
, vol.9
, pp. 296-300
-
-
Finn, M.A.1
Fassett, D.R.2
McCall, T.D.3
-
39
-
-
22144451090
-
Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation
-
Gorek J, Acaroglu E, Berven S, et al. Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation. Spine 2005;30:1513-1518
-
(2005)
Spine
, vol.30
, pp. 1513-1518
-
-
Gorek, J.1
Acaroglu, E.2
Berven, S.3
-
40
-
-
33750714051
-
Biomechanical comparison of two new atlantoaxial fixation techniques with C1-2 transarticular screw-graft fixation
-
Hartl R, Chamberlain RH, Fifield MS, et al. Biomechanical comparison of two new atlantoaxial fixation techniques with C1-2 transarticular screw-graft fixation. J Neurosurg Spine 2006;5:336-342
-
(2006)
J Neurosurg Spine
, vol.5
, pp. 336-342
-
-
Hartl, R.1
Chamberlain, R.H.2
Fifield, M.S.3
-
41
-
-
58949099971
-
Biomechanical comparison of a novel C1 posterior locking plate with the Harms technique in a C1-C2 fixation model
-
Kelly BP, Glaser JA, DiAngelo DJ. Biomechanical comparison of a novel C1 posterior locking plate with the Harms technique in a C1-C2 fixation model. Spine 2008;33:E920-5.
-
(2008)
Spine
, vol.33
-
-
Kelly, B.P.1
Glaser, J.A.2
Diangelo, D.J.3
-
42
-
-
33745792102
-
Biomechanical comparison of four C1 to C2 rigid fixative techniques: Anterior transarticular, posterior transar-ticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws
-
Lapsiwala SB, Anderson PA, Oza A, et al. Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transar-ticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 2006;58:516-521
-
(2006)
Neurosurgery
, vol.58
, pp. 516-521
-
-
Lapsiwala, S.B.1
Anderson, P.A.2
Oza, A.3
-
43
-
-
35348906662
-
In vitro biomechanical comparison of transpedicular versus translaminar C-2 screw fixation in C2-3 instrumentation
-
Reddy C, Ingalhalikar AV, Channon S, et al. In vitro biomechanical comparison of transpedicular versus translaminar C-2 screw fixation in C2-3 instrumentation. J Neurosurg Spine 2007;7:414-418
-
(2007)
J Neurosurg Spine
, vol.7
, pp. 414-418
-
-
Reddy, C.1
Ingalhalikar, A.V.2
Channon, S.3
-
44
-
-
0023723917
-
Biomechanical evaluation of spinal fixation devices: I. A conceptual framework
-
Panjabi MM. Biomechanical evaluation of spinal fixation devices: I. A conceptual framework. Spine 1988;13:1129-1134
-
(1988)
Spine
, vol.13
, pp. 1129-1134
-
-
Panjabi, M.M.1
-
46
-
-
34247844465
-
A comparative biomechanical analysis of spinal instability and instrumentation of the cervicothoracic junction: An in vitro human cadaveric model
-
Prybis BG, Tortolani PJ, Hu N, et al. A comparative biomechanical analysis of spinal instability and instrumentation of the cervicothoracic junction: an in vitro human cadaveric model. J Spinal Disord Tech 2007;20:233-238
-
(2007)
J Spinal Disord Tech
, vol.20
, pp. 233-238
-
-
Prybis, B.G.1
Tortolani, P.J.2
Hu, N.3
-
47
-
-
0023238592
-
Analysis of the morphometric characteristics of the thoracic and lumbar pedicles
-
Zindrick MR, Wiltse LL, Doornik A, et al. Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine 1987;12:160-166
-
(1987)
Spine
, vol.12
, pp. 160-166
-
-
Zindrick, M.R.1
Wiltse, L.L.2
Doornik, A.3
|