메뉴 건너뛰기




Volumn 33, Issue 24, 2008, Pages

Biomechanical comparison of a novel C1 posterior locking plate with the harms technique in A C1-C2 fixation model

Author keywords

Atlantoaxial fixation; Biomechanics; C1 anatomy; C1 lateral mass screw; C1 posterior plate; C2 pars screw; Intralaminar screw; Spinal fixation

Indexed keywords

ARTICLE; ATLANTOAXIAL JOINT; BIOMECHANICS; BONE PLATE; BONE PROSTHESIS; BONE SCREW; CADAVER; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; HUMAN; IN VITRO STUDY; JOINT CHARACTERISTICS AND FUNCTIONS; ODONTOID PROCESS; PRIORITY JOURNAL; SPINE STABILIZATION; ADULT; AGED; CERVICAL SPINE; COMPARATIVE STUDY; FEASIBILITY STUDY; FEMALE; INSTRUMENTATION; JOINT INSTABILITY; MALE; MATERIALS TESTING; METHODOLOGY; MIDDLE AGED; PATHOPHYSIOLOGY; PROSTHESIS; RADIOGRAPHY; SPINE FUSION;

EID: 58949099971     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e318185943d     Document Type: Article
Times cited : (18)

References (22)
  • 1
    • 0030055004 scopus 로고    scopus 로고
    • Biomechanical characteristics of C1-2 cable fixations
    • Dickman CA, Crawford NR, Paramore CG. Biomechanical characteristics of C1-2 cable fixations. J Neurosurg 1996;85:316-22.
    • (1996) J Neurosurg , vol.85 , pp. 316-322
    • Dickman, C.A.1    Crawford, N.R.2    Paramore, C.G.3
  • 2
    • 0026694623 scopus 로고
    • Biomechanical evaluation of four different posterior atlantoaxial fixation techniques
    • Grob D, Crisco JJ III, Panjabi MM, et al. Biomechanical evaluation of four different posterior atlantoaxial fixation techniques. Spine 1992;17:480 -90.
    • (1992) Spine , vol.17 , pp. 480-490
    • Grob, D.1    Crisco III, J.J.2    Panjabi, M.M.3
  • 3
    • 0025998726 scopus 로고
    • Anatomic and biomechanical assessment of transarticular screw fixation for atlantoaxial instability
    • Hanson PB, Montesano PX, Sharkey NA,et al. Anatomic and biomechanical assessment of transarticular screw fixation for atlantoaxial instability. Spine 1991;16:1141-5.
    • (1991) Spine , vol.16 , pp. 1141-1145
    • Hanson, P.B.1    Montesano, P.X.2    Sharkey, N.A.3
  • 4
    • 0034669440 scopus 로고    scopus 로고
    • Biomechanical comparison of five different atlantoaxial posterior fixation techniques
    • Henriques T, Cunningham BW, Olerud C, et al. Biomechanical comparison of five different atlantoaxial posterior fixation techniques. Spine 2000;25: 2877-83.
    • (2000) Spine , vol.25 , pp. 2877-2883
    • Henriques, T.1    Cunningham, B.W.2    Olerud, C.3
  • 5
    • 0033193322 scopus 로고    scopus 로고
    • Biomechanical study of atlantoaxial arthrodesis: Transarticular screw fixation versus modified Brooks posterior wiring
    • Mitchell TC, Sadasivan KK, Ogden AL, et al. Biomechanical study of atlantoaxial arthrodesis: transarticular screw fixation versus modified Brooks posterior wiring. J Orthop Trauma 1999;13:483-9.
    • (1999) J Orthop Trauma , vol.13 , pp. 483-489
    • Mitchell, T.C.1    Sadasivan, K.K.2    Ogden, A.L.3
  • 6
    • 0031896021 scopus 로고    scopus 로고
    • Vertebral artery injury in C1-2 transarticular screw fixation: Results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons
    • Wright NM, Lauryssen C. Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons. J Neurosurg 1998;88:634-40.
    • (1998) J Neurosurg , vol.88 , pp. 634-640
    • Wright, N.M.1    Lauryssen, C.2
  • 7
    • 66249100726 scopus 로고    scopus 로고
    • A novel safer technique of posterior C1-2 fixation utilizing bilateral crossing C2 laminar screws and C1 lateral mass screws
    • Scottsdale, AZ
    • Wright NM. A novel safer technique of posterior C1-2 fixation utilizing bilateral crossing C2 laminar screws and C1 lateral mass screws. In: Cervical Spine Research Society; 2003; Scottsdale, AZ.
    • (2003) Cervical Spine Research Society
    • Wright, N.M.1
  • 8
    • 1842686189 scopus 로고    scopus 로고
    • Posterior C2 fixation using bilateral, crossing C2 laminar screws: Case series and technical note
    • Wright NM. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 2004;17: 158-62.
    • (2004) J Spinal Disord Tech , vol.17 , pp. 158-162
    • Wright, N.M.1
  • 9
    • 0035890208 scopus 로고    scopus 로고
    • Posterior C1-C2 fusion with polyaxial screw and rod fixation
    • Harms J, Melcher PR. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine 2001;26:2467-71.
    • (2001) Spine , vol.26 , pp. 2467-2471
    • Harms, J.1    Melcher, P.R.2
  • 10
    • 0033568717 scopus 로고    scopus 로고
    • Differential biomechanical effects of injury and wiring at C1-C2
    • Crawford NR, Hurlbert RJ, Choi WG, et al. Differential biomechanical effects of injury and wiring at C1-C2. Spine 1999;24:1894-902.
    • (1999) Spine , vol.24 , pp. 1894-1902
    • Crawford, N.R.1    Hurlbert, R.J.2    Choi, W.G.3
  • 11
    • 0037112085 scopus 로고    scopus 로고
    • Biomechanical testing of posterior atlantoaxial fixation techniques
    • Melcher RP, Puttlitz CM, Kleinstueck FS, et al. Biomechanical testing of posterior atlantoaxial fixation techniques. Spine 2002;27:2435- 40.
    • (2002) Spine , vol.27 , pp. 2435-2440
    • Melcher, R.P.1    Puttlitz, C.M.2    Kleinstueck, F.S.3
  • 12
    • 0011885838 scopus 로고    scopus 로고
    • Biomechanical analysis of cranial settling after transoral odontoidectomy
    • Naderi S, Crawford NR, Melton MS, et al. Biomechanical analysis of cranial settling after transoral odontoidectomy. Neurosurg Focus 1999;6:e7.
    • (1999) Neurosurg Focus , vol.6
    • Naderi, S.1    Crawford, N.R.2    Melton, M.S.3
  • 13
    • 28844500192 scopus 로고    scopus 로고
    • An improved biomechanical testing protocol for evaluating spinal arthroplasty and motion preservation devices in a multilevel human cadaveric cervical model
    • DiAngelo DJ, Foley KT. An improved biomechanical testing protocol for evaluating spinal arthroplasty and motion preservation devices in a multilevel human cadaveric cervical model. Neurosurg Focus 2004;17:E4.
    • (2004) Neurosurg Focus , vol.17
    • DiAngelo, D.J.1    Foley, K.T.2
  • 14
    • 0032732256 scopus 로고    scopus 로고
    • The in vitro effects of instrumentation on multilevel cervical strut-graft mechanics
    • Foley KT, DiAngelo DJ, Rampersaud YR, et al. The in vitro effects of instrumentation on multilevel cervical strut-graft mechanics. Spine 1999;24: 2366-76.
    • (1999) Spine , vol.24 , pp. 2366-2376
    • Foley, K.T.1    DiAngelo, D.J.2    Rampersaud, Y.R.3
  • 15
    • 14744296016 scopus 로고    scopus 로고
    • Biomechanical comparison of C1-2 posterior fixation techniques
    • Hott JS, Lynch JJ, Chamberlain RH, et al. Biomechanical comparison of C1-2 posterior fixation techniques. J Neurosurg Spine 2005;2:175-81.
    • (2005) J Neurosurg Spine , vol.2 , pp. 175-181
    • Hott, J.S.1    Lynch, J.J.2    Chamberlain, R.H.3
  • 16
    • 1542378014 scopus 로고    scopus 로고
    • Biomechanical comparison of anterior and posterior stabilization methods in atlantoaxial instability
    • Kim SM, Lim TJ, Paterno J, et al. Biomechanical comparison of anterior and posterior stabilization methods in atlantoaxial instability. J Neurosurg 2004; 100(suppl 3):277-83.
    • (2004) J Neurosurg , vol.100 , Issue.SUPPL. 3 , pp. 277-283
    • Kim, S.M.1    Lim, T.J.2    Paterno, J.3
  • 17
    • 13444291294 scopus 로고    scopus 로고
    • Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: Transarticular screw fixation versus screw and rod fixation
    • discussion 151-9
    • Kuroki H, Rengachary SS, Goel VK, et al. Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation. Neurosurgery 2005;56(suppl 1):151-9; discussion 151-9.
    • (2005) Neurosurgery , vol.56 , Issue.SUPPL. 1 , pp. 151-159
    • Kuroki, H.1    Rengachary, S.S.2    Goel, V.K.3
  • 18
    • 33750714051 scopus 로고    scopus 로고
    • Biomechanical comparison of two new atlantoaxial fixation techniques with C1-2 transarticular screw-graft fixation
    • Hartl R, Chamberlain RH, Fifield MS, et al. Biomechanical comparison of two new atlantoaxial fixation techniques with C1-2 transarticular screw-graft fixation. J Neurosurg Spine 2006;5:336-42.
    • (2006) J Neurosurg Spine , vol.5 , pp. 336-342
    • Hartl, R.1    Chamberlain, R.H.2    Fifield, M.S.3
  • 20
    • 22144451090 scopus 로고    scopus 로고
    • Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation
    • Gorek J, Acaroglu E, Berven S, et al. Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation. Spine 2005;30: 1513-8.
    • (2005) Spine , vol.30 , pp. 1513-1518
    • Gorek, J.1    Acaroglu, E.2    Berven, S.3
  • 21
    • 33745792102 scopus 로고    scopus 로고
    • Biomechanical comparison of four C1 to C2 rigid fixative techniques: Anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws
    • discussion 516-21
    • Lapsiwala SB, Anderson PA, Oza A, et al. Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 2006;58:516-21; discussion 516-21.
    • (2006) Neurosurgery , vol.58 , pp. 516-521
    • Lapsiwala, S.B.1    Anderson, P.A.2    Oza, A.3
  • 22
    • 0028032370 scopus 로고
    • The quantitative anatomy of the atlas
    • Doherty BJ, Heggeness MH. The quantitative anatomy of the atlas. Spine 1994;19:2497-500.
    • (1994) Spine , vol.19 , pp. 2497-2500
    • Doherty, B.J.1    Heggeness, M.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.