-
1
-
-
56449087212
-
The results of arthroscopic subscapularis tendon repairs
-
C.R. Adams, J.D. Schoolfield, and S.S. Burkhart The results of arthroscopic subscapularis tendon repairs Arthroscopy 24 2008 1381 1389
-
(2008)
Arthroscopy
, vol.24
, pp. 1381-1389
-
-
Adams, C.R.1
Schoolfield, J.D.2
Burkhart, S.S.3
-
2
-
-
34047242088
-
Arthroscopic rotator cuff repair using a triple-loaded suture anchor and a modified Mason-Allen technique (Alex stitch)
-
A. Castagna, R. Garofalo, M. Conti, M. Borroni, and S.J. Snyder Arthroscopic rotator cuff repair using a triple-loaded suture anchor and a modified Mason-Allen technique (Alex stitch) Arthroscopy 23 2007 440.e1 440.e4 www.arthroscopyjournal.org
-
(2007)
Arthroscopy
, vol.23
-
-
Castagna, A.1
Garofalo, R.2
Conti, M.3
Borroni, M.4
Snyder, S.J.5
-
3
-
-
43049123163
-
Arthroscopic repair of full-thickness tears of the rotator cuff in patients younger than 40 years
-
S.G. Krishnan, D.C. Harkins, S.C. Schiffern, S.D. Pennington, and W.Z. Burkhead Arthroscopic repair of full-thickness tears of the rotator cuff in patients younger than 40 years Arthroscopy 24 2008 324 328
-
(2008)
Arthroscopy
, vol.24
, pp. 324-328
-
-
Krishnan, S.G.1
Harkins, D.C.2
Schiffern, S.C.3
Pennington, S.D.4
Burkhead, W.Z.5
-
4
-
-
34047143640
-
Cyclic load testing of biodegradable suture anchors containing 2 high-strength sutures
-
F.A. Barber, D.A. Coons, and M. Ruiz-Suarez Cyclic load testing of biodegradable suture anchors containing 2 high-strength sutures Arthroscopy 23 2007 355 360
-
(2007)
Arthroscopy
, vol.23
, pp. 355-360
-
-
Barber, F.A.1
Coons, D.A.2
Ruiz-Suarez, M.3
-
5
-
-
21444435692
-
Failure mode of suture anchors as a function of insertion depth
-
C.K. Bynum, S. Lee, A. Mahar, J. Tasto, and R. Pedowitz Failure mode of suture anchors as a function of insertion depth Am J Sports Med 33 2005 1030 1034
-
(2005)
Am J Sports Med
, vol.33
, pp. 1030-1034
-
-
Bynum, C.K.1
Lee, S.2
Mahar, A.3
Tasto, J.4
Pedowitz, R.5
-
6
-
-
60549090404
-
A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: The SwiveLock-FiberChain construct versus standard double-row repair
-
S.S. Burkhart, C.R. Adams, and J.D. Schoolfield A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: The SwiveLock-FiberChain construct versus standard double-row repair Arthroscopy 25 2009 274 281
-
(2009)
Arthroscopy
, vol.25
, pp. 274-281
-
-
Burkhart, S.S.1
Adams, C.R.2
Schoolfield, J.D.3
-
7
-
-
67949124836
-
A biomechanical comparison of 2 transosseous-equivalent double-row rotator cuff repair techniques using bioabsorbable anchors: Cyclic loading and failure behavior
-
J.T. Spang, S. Buchmann, and P.U. Brucker A biomechanical comparison of 2 transosseous-equivalent double-row rotator cuff repair techniques using bioabsorbable anchors: Cyclic loading and failure behavior Arthroscopy 25 2009 872 879
-
(2009)
Arthroscopy
, vol.25
, pp. 872-879
-
-
Spang, J.T.1
Buchmann, S.2
Brucker, P.U.3
-
8
-
-
44249105621
-
Medial rotator cuff failure after arthroscopic double-row rotator cuff repair
-
J.N. Trantalis, R.S. Boorman, K. Pletsch, and I.K. Lo Medial rotator cuff failure after arthroscopic double-row rotator cuff repair Arthroscopy 24 2008 727 731
-
(2008)
Arthroscopy
, vol.24
, pp. 727-731
-
-
Trantalis, J.N.1
Boorman, R.S.2
Pletsch, K.3
Lo, I.K.4
-
9
-
-
34249909234
-
Clinical evidence shows no difference between single- and double-row repair for rotator cuff tears
-
D.J. Reardon, and N. Maffulli Clinical evidence shows no difference between single- and double-row repair for rotator cuff tears Arthroscopy 23 2007 670 673
-
(2007)
Arthroscopy
, vol.23
, pp. 670-673
-
-
Reardon, D.J.1
Maffulli, N.2
-
10
-
-
47649124821
-
Single-row modified Mason-Allen versus double-row arthroscopic rotator cuff repair: A biomechanical and surface area comparison
-
C.O. Nelson, M.J. Sileo, M.G. Grossman, and F. Serra-Hsu Single-row modified Mason-Allen versus double-row arthroscopic rotator cuff repair: A biomechanical and surface area comparison Arthroscopy 24 2008 941 948
-
(2008)
Arthroscopy
, vol.24
, pp. 941-948
-
-
Nelson, C.O.1
Sileo, M.J.2
Grossman, M.G.3
Serra-Hsu, F.4
-
11
-
-
34249879850
-
Arthroscopic rotator cuff repairs: An anatomic and biomechanical rationale for different suture-anchor repair configurations
-
B.J. Cole, N.S. ElAttrache, and A. Anbari Arthroscopic rotator cuff repairs: An anatomic and biomechanical rationale for different suture-anchor repair configurations Arthroscopy 23 2007 662 669
-
(2007)
Arthroscopy
, vol.23
, pp. 662-669
-
-
Cole, B.J.1
Elattrache, N.S.2
Anbari, A.3
-
12
-
-
36549000239
-
Single-row suture anchor repair of the rotator cuff is biomechanically equivalent to double-row repair in a bovine model
-
A. Mahar, J. Tamborlane, R. Oka, J. Esch, and R.A. Pedowitz Single-row suture anchor repair of the rotator cuff is biomechanically equivalent to double-row repair in a bovine model Arthroscopy 23 2007 1265 1270
-
(2007)
Arthroscopy
, vol.23
, pp. 1265-1270
-
-
Mahar, A.1
Tamborlane, J.2
Oka, R.3
Esch, J.4
Pedowitz, R.A.5
-
13
-
-
34748873787
-
Arthroscopic double-row suture anchor fixation of minimally displaced greater tuberosity fractures
-
J.H. Ji, W.Y. Kim, and K.H. Ra Arthroscopic double-row suture anchor fixation of minimally displaced greater tuberosity fractures Arthroscopy 23 2007 1133.e1 1133.e4 www.arthroscopyjournal.org
-
(2007)
Arthroscopy
, vol.23
-
-
Ji, J.H.1
Kim, W.Y.2
Ra, K.H.3
-
14
-
-
57849087668
-
Single-row versus double-row arthroscopic rotator cuff repair: A prospective randomized clinical study
-
A. Grasso, G. Milano, M. Salvatore, G. Falcone, L. Deriu, and C. Fabbriciani Single-row versus double-row arthroscopic rotator cuff repair: A prospective randomized clinical study Arthroscopy 25 2009 4 12
-
(2009)
Arthroscopy
, vol.25
, pp. 4-12
-
-
Grasso, A.1
Milano, G.2
Salvatore, M.3
Falcone, G.4
Deriu, L.5
Fabbriciani, C.6
-
15
-
-
67349281418
-
A new approach to improving the tissue grip of the medial-row repair in the suture-bridge technique: The "modified lasso-loop stitch."
-
B. Toussaint, E. Schnaser, L. Lafosse, J. Bahurel, and R. Gobezie A new approach to improving the tissue grip of the medial-row repair in the suture-bridge technique: The "modified lasso-loop stitch." Arthroscopy 25 2009 691 695
-
(2009)
Arthroscopy
, vol.25
, pp. 691-695
-
-
Toussaint, B.1
Schnaser, E.2
Lafosse, L.3
Bahurel, J.4
Gobezie, R.5
-
16
-
-
33750458999
-
Triple-loaded single-anchor stitch configurations: An analysis of cyclically loaded suture-tendon interface security
-
D.A. Coons, F.A. Barber, and M.A. Herbert Triple-loaded single-anchor stitch configurations: An analysis of cyclically loaded suture-tendon interface security Arthroscopy 22 2006 1154 1158
-
(2006)
Arthroscopy
, vol.22
, pp. 1154-1158
-
-
Coons, D.A.1
Barber, F.A.2
Herbert, M.A.3
-
17
-
-
38549160736
-
Cyclic load testing and ultimate failure strength of biodegradable glenoid anchors
-
F.A. Barber, D.A. Coons, and M. Ruiz-Suarez Cyclic load testing and ultimate failure strength of biodegradable glenoid anchors Arthroscopy 24 2008 224 228
-
(2008)
Arthroscopy
, vol.24
, pp. 224-228
-
-
Barber, F.A.1
Coons, D.A.2
Ruiz-Suarez, M.3
-
18
-
-
77952712819
-
Cyclic load testing and ultimate failure strength of hip arthroscopy suture anchors
-
M. Ruiz-Suarez, J. Aziz-Jacobo, and F.A. Barber Cyclic load testing and ultimate failure strength of hip arthroscopy suture anchors Arthroscopy 26 2010 762 768
-
(2010)
Arthroscopy
, vol.26
, pp. 762-768
-
-
Ruiz-Suarez, M.1
Aziz-Jacobo, J.2
Barber, F.A.3
-
19
-
-
54149106127
-
Deformities associated with the suture-bridge technique for full-thickness rotator cuff tears
-
K.C. Kim, K.J. Rhee, and H.D. Shin Deformities associated with the suture-bridge technique for full-thickness rotator cuff tears Arthroscopy 24 2008 1251 1257
-
(2008)
Arthroscopy
, vol.24
, pp. 1251-1257
-
-
Kim, K.C.1
Rhee, K.J.2
Shin, H.D.3
-
20
-
-
47649097837
-
Cyclic loading of rotator cuff reconstructions: Single-row repair with modified suture configurations versus double-row repair
-
O. Lorbach, F. Bachelier, J. Vees, D. Kohn, and D. Pape Cyclic loading of rotator cuff reconstructions: Single-row repair with modified suture configurations versus double-row repair Am J Sports Med 36 2008 1504 1510
-
(2008)
Am J Sports Med
, vol.36
, pp. 1504-1510
-
-
Lorbach, O.1
Bachelier, F.2
Vees, J.3
Kohn, D.4
Pape, D.5
-
21
-
-
47649117959
-
Arthroscopic reduction and fixation with suture-bridge technique for displaced or comminuted greater tuberosity fractures
-
H.S. Song, and G.R. Williams Jr Arthroscopic reduction and fixation with suture-bridge technique for displaced or comminuted greater tuberosity fractures Arthroscopy 24 2008 956 960
-
(2008)
Arthroscopy
, vol.24
, pp. 956-960
-
-
Song, H.S.1
Williams Jr., G.R.2
|