메뉴 건너뛰기




Volumn 18, Issue 3, 2010, Pages 279-292

Improving visibility of X-ray phase-contrast imaging with Wiener filtering

Author keywords

[No Author keywords available]

Indexed keywords

DEBLURRING; DIFFRACTION INTEGRAL; FINITE SIZE; IN-LINE; INTERFERENCE PATTERNS; MODEL-BASED; NOISE SPECTRA; NOISE SUPPRESSION; OPTIMAL TRADEOFFS; PHASE-CONTRAST; PHYSICAL PARAMETERS; POINT-SPREAD FUNCTIONS; SIMULATION TOOL; SPATIAL RESOLUTION; SYSTEM NOISE; VERTICAL DIRECTION; WIENER FILTERS; WIENER-FILTERING; X-RAY PHASE-CONTRAST IMAGING;

EID: 77956298908     PISSN: 08953996     EISSN: None     Source Type: Journal    
DOI: 10.3233/XST-2010-0260     Document Type: Article
Times cited : (7)

References (25)
  • 4
    • 24044538888 scopus 로고    scopus 로고
    • Xray phase imaging with a grating interferometer
    • T. Weitkamp, A. Diaz, C. David et al., Xray phase imaging with a grating interferometer, Opt. Express 13 (2005), 6296-6304.
    • (2005) Opt. Express , vol.13 , pp. 6296-6304
    • Weitkamp, T.1    Diaz, A.2    David, C.3
  • 5
    • 33645795432 scopus 로고    scopus 로고
    • Phase retrieval and differential phasecontrast imaging with lowbrilliance Xray sources
    • F. Pfeiffer, T.Weitkamp, O. Bunk et al., Phase retrieval and differential phasecontrast imaging with lowbrilliance Xray sources, Nature Physics 2 (2006), 258-261.
    • (2006) Nature Physics , vol.2 , pp. 258-261
    • Pfeiffer, F.1    Weitkamp, T.2    Bunk, O.3
  • 7
    • 58149216496 scopus 로고    scopus 로고
    • Low density contrast agents for xray phase contrast imaging: The use of ambient air for xray angiography of excised murine liver tissue
    • C. Laperle, T. Hamilton, P. Wintermeyer et al., Low density contrast agents for xray phase contrast imaging: the use of ambient air for xray angiography of excised murine liver tissue, Physics in Medicine and Biology 53 (2008), 6911-6923.
    • (2008) Physics in Medicine and Biology , vol.53 , pp. 6911-6923
    • Laperle, C.1    Hamilton, T.2    Wintermeyer, P.3
  • 8
    • 34548046244 scopus 로고    scopus 로고
    • A codedaperture technique allowing xray phase contrast imaging with conventional sources
    • A. Olivo and R. Speller, A codedaperture technique allowing xray phase contrast imaging with conventional sources, Applied Physics Letters 91 (2007), 074106-074103.
    • (2007) Applied Physics Letters , vol.91 , pp. 074106-074103
    • Olivo, A.1    Speller, R.2
  • 9
    • 33846570888 scopus 로고    scopus 로고
    • Clarification of aspects in inline phasesensitive xray imaging
    • X.Wu and H Liu, Clarification of aspects in inline phasesensitive xray imaging, Medical Physics 34 (2007), 737-743.
    • (2007) Medical Physics , vol.34 , pp. 737-743
    • Wu, X.1    Liu, H.2
  • 10
    • 0029955942 scopus 로고    scopus 로고
    • Phasecontrast imaging using polychromatic hard Xrays
    • S. Wilkins, T. Gureyev, D. Gao et al., Phasecontrast imaging using polychromatic hard Xrays, Nature 384 (1996), 335-338.
    • (1996) Nature , vol.384 , pp. 335-338
    • Wilkins, S.1    Gureyev, T.2    Gao, D.3
  • 11
    • 0037693022 scopus 로고    scopus 로고
    • A general theoretical formalism for Xray phase contrast imaging
    • X. Wu and H Liu, A general theoretical formalism for Xray phase contrast imaging, Journal of XRay Science and Technology 11 (2003), 33-42.
    • (2003) Journal of XRay Science and Technology , vol.11 , pp. 33-42
    • Wu, X.1    Liu, H.2
  • 12
    • 33745085977 scopus 로고    scopus 로고
    • Experimental validation of a simple model capable of predicting the phase contrast imaging capabilities of any xray imaging system
    • A. Olivo and R. Speller, Experimental validation of a simple model capable of predicting the phase contrast imaging capabilities of any xray imaging system, Physics in Medicine and Biology 51 (2006), 3015-3030.
    • (2006) Physics in Medicine and Biology , vol.51 , pp. 3015-3030
    • Olivo, A.1    Speller, R.2
  • 14
    • 56349120011 scopus 로고    scopus 로고
    • Phase contrast imaging simulation and measurements using polychromatic sources with small sourceobject distances
    • B. Golosio, P.Delogu, I. Zanette et al., Phase contrast imaging simulation and measurements using polychromatic sources with small sourceobject distances, Journal of Applied Physics 104 (2008).
    • (2008) Journal of Applied Physics , vol.104
    • Golosio, B.1    Delogu, P.2    Zanette, I.3
  • 18
    • 0030657556 scopus 로고    scopus 로고
    • An accurate method for computergenerating tungsten anode xray spectra from 30 to 140 kV
    • J. Boone and J. Seibert, An accurate method for computergenerating tungsten anode xray spectra from 30 to 140 kV, Medical Physics 24 (1997), 1661-1670.
    • (1997) Medical Physics , vol.24 , pp. 1661-1670
    • Boone, J.1    Seibert, J.2
  • 20
    • 0000292076 scopus 로고    scopus 로고
    • Contrast and resolution in imaging with a microfocus xray source
    • A. Pogany, D. Gao and S.W. Wilkins, Contrast and resolution in imaging with a microfocus xray source, Review of Scientific Instruments 68 (1997), 2774-2782.
    • (1997) Review of Scientific Instruments , vol.68 , pp. 2774-2782
    • Pogany, A.1    Gao, D.2    Wilkins, S.W.3
  • 21
    • 4644297198 scopus 로고    scopus 로고
    • A new theory of phasecontrast xray imaging based on Wigner distributions
    • X. Wu and H Liu, A new theory of phasecontrast xray imaging based on Wigner distributions, Medical Physics 31 (2004), 2378-2384.
    • (2004) Medical Physics , vol.31 , pp. 2378-2384
    • Wu, X.1    Liu, H.2
  • 22
    • 35848943282 scopus 로고    scopus 로고
    • Modelling of a novel xray phase contrast imaging technique based on coded apertures
    • A. Olivo and R. Speller, Modelling of a novel xray phase contrast imaging technique based on coded apertures, Physics in Medicine and Biology 52 (2007), 19.
    • (2007) Physics in Medicine and Biology , vol.52 , pp. 19
    • Olivo, A.1    Speller, R.2
  • 23
    • 0026837927 scopus 로고
    • A simple method for determining the modulation transfer function in digital radiography, Medical Imaging
    • H. Fujita, D. Tsai, T. Itoh et al., A simple method for determining the modulation transfer function in digital radiography, Medical Imaging, IEEE Transactions on 11 (1992), 34-39.
    • (1992) IEEE Transactions on , vol.11 , pp. 34-39
    • Fujita, H.1    Tsai, D.2    Itoh, T.3
  • 24
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • E. Samei,M. Flynn and D. Reimann, A method for measuring the presampled MTF of digital radiographic systems using an edge test device, Medical Physics 25 (1998), 102-113.
    • (1998) Medical Physics , vol.25 , pp. 102-113
    • Samei, E.1    Flynn, M.2    Reimann, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.