-
1
-
-
23644446162
-
The channelopathies: Novel insights into molecular and genetic mechanisms of human disease
-
Kass, R. S. The channelopathies: Novel insights into molecular and genetic mechanisms of human disease. J. Clin. Invest., 2005, 115(8), 1986-1989.
-
(2005)
J. Clin. Invest.
, vol.115
, Issue.8
, pp. 1986-1989
-
-
Kass, R.S.1
-
2
-
-
0017258698
-
Single-channel currents recorded from membrane of denervated frog muscle fibres
-
Neher, E. and Sakmann, B. Single-channel currents recorded from membrane of denervated frog muscle fibres. Nature, 1976, 260(5554), 799-802.
-
(1976)
Nature
, vol.260
, Issue.5554
, pp. 799-802
-
-
Neher, E.1
Sakmann, B.2
-
4
-
-
0001244063
-
Action potentials recorded from inside a nerve fibre
-
Hodgkin, A. L. and Huxley, A. F. Action potentials recorded from inside a nerve fibre. Nature, 1939, 144(3651), 710-711.
-
(1939)
Nature
, vol.144
, Issue.3651
, pp. 710-711
-
-
Hodgkin, A.L.1
Huxley, A.F.2
-
5
-
-
19144365379
-
Membrane potentials and excitation of impaled single muscle fibers
-
Graham, J. and Gerard, R. W. Membrane potentials and excitation of impaled single muscle fibers. J. Cellular Comp. Physiol., 1946, 28(1), 99-117.
-
(1946)
J. Cellular Comp. Physiol.
, vol.28
, Issue.1
, pp. 99-117
-
-
Graham, J.1
Gerard, R.W.2
-
6
-
-
84892794173
-
The normal membrane potential of frog sartorius fibers
-
Ling, G. and Gerard, R. W. The normal membrane potential of frog sartorius fibers. J. Cellular Comp. Physiol., 1949, 34(3), 383-396.
-
(1949)
J. Cellular Comp. Physiol.
, vol.34
, Issue.3
, pp. 383-396
-
-
Ling, G.1
Gerard, R.W.2
-
7
-
-
0001149903
-
Dynamic electrical characteristics of the squid axon membrane
-
Cole, K. S. Dynamic electrical characteristics of the squid axon membrane. Arch. Sci. Physiol., 1949, 3(25), 3-25.
-
(1949)
Arch. Sci. Physiol.
, vol.3
, Issue.25
, pp. 3-25
-
-
Cole, K.S.1
-
9
-
-
0016528972
-
Voltage clamping with a single microelectrode
-
Wilson, W. A. and Goldner, M. M. Voltage clamping with a single microelectrode. J. Neurobiol., 1975, 6(4), 411-422.
-
(1975)
J. Neurobiol.
, vol.6
, Issue.4
, pp. 411-422
-
-
Wilson, W.A.1
Goldner, M.M.2
-
10
-
-
0016733928
-
Potassium activation in Helix aspersa neurones under voltage clamp: A component mediated by calcium influx
-
Meech, R. W. and Standen, N. B. Potassium activation in Helix aspersa neurones under voltage clamp: a component mediated by calcium influx. J. Physiol., 1975, 249(2), 211-259.
-
(1975)
J. Physiol.
, vol.249
, Issue.2
, pp. 211-259
-
-
Meech, R.W.1
Standen, N.B.2
-
11
-
-
0017767797
-
Asymmetrical displacement currents in nerve cell membrane and effect of internal fluoride
-
Kostyuk, P. G., Krishtal, O. A., and Pidoplichko, V. I. Asymmetrical displacement currents in nerve cell membrane and effect of internal fluoride. Nature, 1977, 267(5606), 70-72.
-
(1977)
Nature
, vol.267
, Issue.5606
, pp. 70-72
-
-
Kostyuk, P.G.1
Krishtal, O.A.2
Pidoplichko, V.I.3
-
12
-
-
0018899589
-
The suction pipette method for internal perfusion and voltage clamp of small excitable cells
-
Lee, K. S., Akaike, N., and Brown, A. M. The suction pipette method for internal perfusion and voltage clamp of small excitable cells. J. Neurosci. Meths, 1980, 2(1), 51.
-
(1980)
J. Neurosci. Meths
, vol.2
, Issue.1
, pp. 51
-
-
Lee, K.S.1
Akaike, N.2
Brown, A.M.3
-
13
-
-
0017841119
-
The extracellular patch clamp: A method for resolving currents through individual open channels in biological membranes
-
Neher, E., Sakmann, B., and Steinbach, J. H. The extracellular patch clamp: a method for resolving currents through individual open channels in biological membranes. Pflugers Archiv Eur. J. Physiol., 1978, 375(2), 219-228.
-
(1978)
Pflugers Archiv Eur. J. Physiol.
, vol.375
, Issue.2
, pp. 219-228
-
-
Neher, E.1
Sakmann, B.2
Steinbach, J.H.3
-
14
-
-
0019143565
-
Single Na+ channel currents observed in cultured rat muscle cells
-
Sigworth, F. J. and Neher, E. Single Na+ channel currents observed in cultured rat muscle cells. Nature, 1980, 287(5781), 447-449.
-
(1980)
Nature
, vol.287
, Issue.5781
, pp. 447-449
-
-
Sigworth, F.J.1
Neher, E.2
-
15
-
-
0019441262
-
Improved patch-clamp techniques for high-resolution current recording from cells and cellfree membrane patches
-
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., and Sigworth, F. J. Improved patch-clamp techniques for high-resolution current recording from cells and cellfree membrane patches. Pflugers Archiv Eur. J. Physiol., 1981, 391(2), 85-100.
-
(1981)
Pflugers Archiv Eur. J. Physiol.
, vol.391
, Issue.2
, pp. 85-100
-
-
Hamill, O.P.1
Marty, A.2
Neher, E.3
Sakmann, B.4
Sigworth, F.J.5
-
16
-
-
0013657423
-
Discrete changes of cell membrane capacitance observed under conditions of enhanced secretion in bovine adrenal chromaffin cells
-
Neher, E. and Marty, A. Discrete changes of cell membrane capacitance observed under conditions of enhanced secretion in bovine adrenal chromaffin cells. Proc. Natn Acad. Sci. USA, 1982, 79(21), 6712-6716.
-
(1982)
Proc. Natn Acad. Sci. USA
, vol.79
, Issue.21
, pp. 6712-6716
-
-
Neher, E.1
Marty, A.2
-
17
-
-
0023795593
-
Muscarinic activation of ionic currents measured by a new whole-cell recording method
-
Horn, R. and Marty, A. Muscarinic activation of ionic currents measured by a new whole-cell recording method. J. Gen. Physiol., 1988, 92(2), 145-159.
-
(1988)
J. Gen. Physiol.
, vol.92
, Issue.2
, pp. 145-159
-
-
Horn, R.1
Marty, A.2
-
18
-
-
0022558268
-
An enzymatic mechanism for calcium current inactivation in dialysed Helix neurones
-
Chad, J. E. and Eckert, R. An enzymatic mechanism for calcium current inactivation in dialysed Helix neurones. J. Physiol., 1986, 378(1), 31-51.
-
(1986)
J. Physiol.
, vol.378
, Issue.1
, pp. 31-51
-
-
Chad, J.E.1
Eckert, R.2
-
19
-
-
0019977144
-
Intracellular metabolism of adenosine 3', 5'-cyclic monophosphate and calcium inward current in perfused neurones of Helix pomatia
-
Doroshenko, P. A., Kostyuk, P. G., and Martynyuk, A. E. Intracellular metabolism of adenosine 3', 5'-cyclic monophosphate and calcium inward current in perfused neurones of Helix pomatia. Neurosci., 1982, 7(9), 2125-2134.
-
(1982)
Neurosci.
, vol.7
, Issue.9
, pp. 2125-2134
-
-
Doroshenko, P.A.1
Kostyuk, P.G.2
Martynyuk, A.E.3
-
20
-
-
0021875701
-
Modulation of calcium channels by norepinephrine in internally dialyzed avian sensory neurons
-
Forscher, P. and Oxford, G. S. Modulation of calcium channels by norepinephrine in internally dialyzed avian sensory neurons. J. Gen. Physiol., 1985, 85(5), 743-763.
-
(1985)
J. Gen. Physiol.
, vol.85
, Issue.5
, pp. 743-763
-
-
Forscher, P.1
Oxford, G.S.2
-
21
-
-
0024429936
-
Influence of sodium-calcium exchange on calcium current rundown and the duration of calcium-dependent chloride currents in pituitary cells studied with whole cell and perforated patch recording
-
Korn, S. J. and Horn, R. Influence of sodium-calcium exchange on calcium current rundown and the duration of calcium-dependent chloride currents in pituitary cells, studied with whole cell and perforated patch recording. J. Gen. Physiol., 1989, 94(5), 789-812.
-
(1989)
J. Gen. Physiol.
, vol.94
, Issue.5
, pp. 789-812
-
-
Korn, S.J.1
Horn, R.2
-
22
-
-
0022629034
-
IgE-mediated degranulation of mast cells does not require opening of ion channels
-
Lindau, M. and Fernandez, J. M. IgE-mediated degranulation of mast cells does not require opening of ion channels. Nature, 1986, 319(6049), 150-153.
-
(1986)
Nature
, vol.319
, Issue.6049
, pp. 150-153
-
-
Lindau, M.1
Fernandez, J.M.2
-
23
-
-
0025775356
-
Low access resistance perforated patch recordings using amphotericin B
-
Rae, J., Cooper, K., Gates, P., and Watsky, M. Low access resistance perforated patch recordings using amphotericin B. J. Neurosci. Meth, 1991, 37(1), 15-26.
-
(1991)
J. Neurosci. Meth
, vol.37
, Issue.1
, pp. 15-26
-
-
Rae, J.1
Cooper, K.2
Gates, P.3
Watsky, M.4
-
24
-
-
0028927345
-
Theory of membrane equilibria and membrane potentials in the presence of non-dialysing electrolytes. A contribution to physical-chemical physiology J
-
Donnan, F. G. Theory of membrane equilibria and membrane potentials in the presence of non-dialysing electrolytes. A contribution to physical-chemical physiology J. Membrane Sci., 1995, 100(1), 45-55.
-
(1995)
Membrane Sci.
, vol.100
, Issue.1
, pp. 45-55
-
-
Donnan, F.G.1
-
25
-
-
0028964438
-
Gramicidin-perforated patch recording: GABA response in mammalian neurones with intact intracellular chloride
-
Ebihara, S., Shirato, K., Harata, N., and Akaike, N. Gramicidin- perforated patch recording: GABA response in mammalian neurones with intact intracellular chloride. J. Physiol., 1995, 484(1), 77.
-
(1995)
J. Physiol.
, vol.484
, Issue.1
, pp. 77
-
-
Ebihara, S.1
Shirato, K.2
Harata, N.3
Akaike, N.4
-
26
-
-
0028937180
-
Perforated-patch recording with gramicidin avoids artifactual changes in intracellular chloride concentration
-
Kyrozis, A. and Reichling, D. B. Perforated-patch recording with gramicidin avoids artifactual changes in intracellular chloride concentration. J. Neurosci. Meth., 1995, 57(1), 27-35.
-
(1995)
J. Neurosci. Meth.
, vol.57
, Issue.1
, pp. 27-35
-
-
Kyrozis, A.1
Reichling, D.B.2
-
27
-
-
0031766409
-
Perforated patch recording with beta-escin
-
Fan, J. S. and Palade, P. Perforated patch recording with beta-escin. Pflugers Archiv Eur. J. Physiol., 1998, 436(6), 1021.
-
(1998)
Pflugers Archiv Eur. J. Physiol.
, vol.436
, Issue.6
, pp. 1021
-
-
Fan, J.S.1
Palade, P.2
-
28
-
-
4444234330
-
B-escin diminishes voltage-gated calcium current rundown in perforated patch-clamp recordings from rat primary afferent neurons
-
Sarantopoulos, C., McCallum, J. B., Kwok, W. M., and Hogan, Q. b-escin diminishes voltage-gated calcium current rundown in perforated patch-clamp recordings from rat primary afferent neurons. J. Neurosci. Meth., 2004, 139(1), 61-68.
-
(2004)
J. Neurosci. Meth.
, vol.139
, Issue.1
, pp. 61-68
-
-
Sarantopoulos, C.1
McCallum, J.B.2
Kwok, W.M.3
Hogan, Q.4
-
29
-
-
0036185043
-
Single-cell electroporation
-
Rae, J. L. and Levis, R. A. Single-cell electroporation. Pflugers Archiv Eur. J. Physiol., 2002, 443(4), 664-670.
-
(2002)
Pflugers Archiv Eur. J. Physiol.
, vol.443
, Issue.4
, pp. 664-670
-
-
Rae, J.L.1
Levis, R.A.2
-
30
-
-
37749005460
-
Targeted patch-clamp recordings and single- cell electroporation of unlabelled neurons in vivo
-
Kitamura, K., Judkewitz, B., Kano, M., Denk, W., and Hausser, M. Targeted patch-clamp recordings and single- cell electroporation of unlabelled neurons in vivo. Nature Meth., 2008, 5(1), 61-67.
-
(2008)
Nature Meth.
, vol.5
, Issue.1
, pp. 61-67
-
-
Kitamura, K.1
Judkewitz, B.2
Kano, M.3
Denk, W.4
Hausser, M.5
-
31
-
-
0026687921
-
Glass technology for patch clamp electrodes
-
Rae, J. L. and Levis, R. A. Glass technology for patch clamp electrodes. Meth. in Enzymology, 1992, 207, 66-92.
-
(1992)
Meth. in Enzymology
, vol.207
, pp. 66-92
-
-
Rae, J.L.1
Levis, R.A.2
-
32
-
-
0034738321
-
Pressure polishing: A method for re-shaping patch pipettes during fire polishing
-
Goodman, M. B. and Lockery, S. R. Pressure polishing: a method for re-shaping patch pipettes during fire polishing. J. Neurosci. Meth, 2000, 100(1), 13-15.
-
(2000)
J. Neurosci. Meth
, vol.100
, Issue.1
, pp. 13-15
-
-
Goodman, M.B.1
Lockery, S.R.2
-
33
-
-
0026767360
-
Constructing a patch clamp setup
-
Levis, R. A. and Rae, J. L. Constructing a patch clamp setup. Meth. in Enzymology, 1992, 207, 14-66.
-
(1992)
Meth. in Enzymology
, vol.207
, pp. 14-66
-
-
Levis, R.A.1
Rae, J.L.2
-
34
-
-
0027368614
-
The use of quartz patch pipettes for low noise single channel recording
-
Levis, R. A. and Rae, J. L. The use of quartz patch pipettes for low noise single channel recording. Biophsy. J., 1993, 65(4), 1666-1677.
-
(1993)
Biophsy. J.
, vol.65
, Issue.4
, pp. 1666-1677
-
-
Levis, R.A.1
Rae, J.L.2
-
35
-
-
0023840429
-
Patch electrode glass composition affects ion channel currents
-
Furman, R. E. and Tanaka, J. C. Patch electrode glass composition affects ion channel currents. Biophys. J., 1988, 53(2), 287-292.
-
(1988)
Biophys. J.
, vol.53
, Issue.2
, pp. 287-292
-
-
Furman, R.E.1
Tanaka, J.C.2
-
36
-
-
0023709863
-
Potassium channel' inactivation' induced by soft-glass patch pipettes
-
Cota, G. and Armstrong, C. M. Potassium channel' inactivation' induced by soft-glass patch pipettes. Biophys. J., 1988, 53(1), 107-109.
-
(1988)
Biophys. J.
, vol.53
, Issue.1
, pp. 107-109
-
-
Cota, G.1
Armstrong, C.M.2
-
37
-
-
0014457408
-
Optimum electrolytic chloriding of silver electrodes
-
Geddes, L. A., Baker, L. E., and Moore, A. G. Optimum electrolytic chloriding of silver electrodes. Med. Biol. Engng Comput., 1969, 7(1), 49-56.
-
(1969)
Med. Biol. Engng Comput.
, vol.7
, Issue.1
, pp. 49-56
-
-
Geddes, L.A.1
Baker, L.E.2
Moore, A.G.3
-
38
-
-
0020642496
-
New technique for reducing the impedance of silver-silver chloride electrodes
-
Grubbs, D. S. and Worley, D. S. New technique for reducing the impedance of silver-silver chloride electrodes. Med. Biol. Engng Comput., 1983, 21(2), 232-234.
-
(1983)
Med. Biol. Engng Comput.
, vol.21
, Issue.2
, pp. 232-234
-
-
Grubbs, D.S.1
Worley, D.S.2
-
39
-
-
33751233255
-
Micro-agar salt bridge in patch-clamp electrode holder stabilizes electrode potentials
-
Shao, X. M. and Feldman, J. L. Micro-agar salt bridge in patch-clamp electrode holder stabilizes electrode potentials. J. Neurosci. Meth., 2007, 159(1), 108-115.
-
(2007)
J. Neurosci. Meth.
, vol.159
, Issue.1
, pp. 108-115
-
-
Shao, X.M.1
Feldman, J.L.2
-
40
-
-
0003703874
-
A convenient electrode holder for glass pipettes to stabilize electrode potentials
-
Snyder, K. V., Kriegstein, A. M., and Sachs, F. A convenient electrode holder for glass pipettes to stabilize electrode potentials. Pflugers Archiv Eur. J. Physiol., 1999, 438(3), 405-411.
-
(1999)
Pflugers Archiv Eur. J. Physiol.
, vol.438
, Issue.3
, pp. 405-411
-
-
Snyder, K.V.1
Kriegstein, A.M.2
Sachs, F.3
-
41
-
-
0021246750
-
Mode of regulation of the ACh-sensitive K-channel by the muscarinic receptor in rabbit atrial cells
-
Soejima, M. and Noma, A. Mode of regulation of the ACh-sensitive K-channel by the muscarinic receptor in rabbit atrial cells. Pflugers Archiv Eur. J. Physiol., 1984, 400(4), 424-431.
-
(1984)
Pflugers Archiv Eur. J. Physiol.
, vol.400
, Issue.4
, pp. 424-431
-
-
Soejima, M.1
Noma, A.2
-
42
-
-
0019731748
-
Single glutamate-activated channels recorded from locust muscle fibres with perfused patch-clamp electrodes
-
Cull-Candy, S. G., Miledi, R., and Parker, I. Single glutamate-activated channels recorded from locust muscle fibres with perfused patch-clamp electrodes. J. Physiol., 1981, 321(1), 195-210.
-
(1981)
J. Physiol.
, vol.321
, Issue.1
, pp. 195-210
-
-
Cull-Candy, S.G.1
Miledi, R.2
Parker, I.3
-
43
-
-
0023612586
-
A novel holder allowing internal perfusion of patch-clamp pipettes
-
Lapointe, J. Y. and Szabo, G. A novel holder allowing internal perfusion of patch-clamp pipettes. Pflugers Archiv Eur. J. Physiol., 1987, 410(1), 212-216.
-
(1987)
Pflugers Archiv Eur. J. Physiol.
, vol.410
, Issue.1
, pp. 212-216
-
-
Lapointe, J.Y.1
Szabo, G.2
-
44
-
-
0024373476
-
Is there a second external lidocaine binding site on mammalian cardiac cells?
-
Alpert, L. A., Fozzard, H. A., Hanck, D. A., and Makielski, J. C. Is there a second external lidocaine binding site on mammalian cardiac cells? Am. J. Physiol.- Heart and Circulatory Physiol., 1989, 257(1), 79-84.
-
(1989)
Am. J. Physiol.- Heart and Circulatory Physiol.
, vol.257
, Issue.1
, pp. 79-84
-
-
Alpert, L.A.1
Fozzard, H.A.2
Hanck, D.A.3
Makielski, J.C.4
-
45
-
-
0023905082
-
Capacitance measurements. An analysis of the phase detector technique used to study exocytosis and endocytosis
-
Joshi, C. and Fernandez, J. M. Capacitance measurements. An analysis of the phase detector technique used to study exocytosis and endocytosis. Biophys. J., 1988, 53(6), 885-892.
-
(1988)
Biophys. J.
, vol.53
, Issue.6
, pp. 885-892
-
-
Joshi, C.1
Fernandez, J.M.2
-
46
-
-
0023858306
-
Patch-clamp techniques for time-resolved capacitance measurements in single cells
-
Lindau, M. and Neher, E. Patch-clamp techniques for time-resolved capacitance measurements in single cells. Pflugers Archiv Eur. J. Physiol., 1988, 411(2), 137-146.
-
(1988)
Pflugers Archiv Eur. J. Physiol.
, vol.411
, Issue.2
, pp. 137-146
-
-
Lindau, M.1
Neher, E.2
-
47
-
-
24044532874
-
Patch amperometry: High-resolution measurement of single-vesicle fusion and release
-
Dernick, G., Gong, L.-W., Tabares, L., de Toledo, G. A., and Lindau, M. Patch amperometry: high-resolution measurement of single-vesicle fusion and release. Nature Meth., 2005, 2(9), 699-708.
-
(2005)
Nature Meth.
, vol.2
, Issue.9
, pp. 699-708
-
-
Dernick, G.1
Gong, L.-W.2
Tabares, L.3
De Toledo, G.A.4
Lindau, M.5
-
48
-
-
66149089087
-
An improved amplifier for patch-clamp recording
-
Offner, F. F. and Clark, B. An improved amplifier for patch-clamp recording. Biophys. J., 1985, 47(142a).
-
(1985)
Biophys. J.
, vol.47
, Issue.142
-
-
Offner, F.F.1
Clark, B.2
-
49
-
-
78651587394
-
An integrating patch-clamping amplifier with on-chip capacitors and reset switch
-
Prakash, J., Jensen, D. N., Paulos, J. J., Grant, A. O., and Strauss, H. C. An integrating patch-clamping amplifier with on-chip capacitors and reset switch. Biophys. J., 1987, 51(70a).
-
(1987)
Biophys. J.
, vol.51
, Issue.70
-
-
Prakash, J.1
Jensen, D.N.2
Paulos, J.J.3
Grant, A.O.4
Strauss, H.C.5
-
50
-
-
0037234427
-
Flip the tip: An automated, high quality, cost-effective patch clamp screen
-
Lepple-Wienhues, A., Ferlinz, K., Seeger, A., and Schafer, A. Flip the tip: an automated, high quality, cost-effective patch clamp screen. Receptors and Channels, 2003, 9(1), 13-17.
-
(2003)
Receptors and Channels
, vol.9
, Issue.1
, pp. 13-17
-
-
Lepple-Wienhues, A.1
Ferlinz, K.2
Seeger, A.3
Schafer, A.4
-
51
-
-
0035892592
-
Ion-channel assay technologies: Quo vadis?
-
Xu, J., Wang, X., Ensign, B., Li, M., Wu, L., and Guia, A. Ion-channel assay technologies: quo vadis? Drug Discovery Today, 2001, 6(24), 1278-1287.
-
(2001)
Drug Discovery Today
, vol.6
, Issue.24
, pp. 1278-1287
-
-
Xu, J.1
Wang, X.2
Ensign, B.3
Li, M.4
Wu, L.5
Guia, A.6
-
52
-
-
0034283554
-
A chip-based biosensor for the functional analysis of single ion channels
-
Schmidt, C., Mayer, M., and Vogel, H. A chip-based biosensor for the functional analysis of single ion channels. Angewandte Chemie, 2000, 39(17), 3137-3140.
-
(2000)
Angewandte Chemie
, vol.39
, Issue.17
, pp. 3137-3140
-
-
Schmidt, C.1
Mayer, M.2
Vogel, H.3
-
53
-
-
0034805579
-
Bilayer reconstitution of voltage-dependent ion channels using a microfabricated silicon chip
-
Pantoja, R., Sigg, D., Blunck, R., Bezanilla, F., and Heath, J. R. Bilayer reconstitution of voltage-dependent ion channels using a microfabricated silicon chip. Biophys. J., 2001, 81(4), 2389-2394.
-
(2001)
Biophys. J.
, vol.81
, Issue.4
, pp. 2389-2394
-
-
Pantoja, R.1
Sigg, D.2
Blunck, R.3
Bezanilla, F.4
Heath, J.R.5
-
54
-
-
7444224648
-
Silicon chipbased patch-clamp electrodes integrated with PDMS microfluidics
-
Pantoja, R., Nagarah, J.M., Starace, D. M.,Melosh, N. A., Blunck, R., Bezanilla, F., and Heath, J. R. Silicon chipbased patch-clamp electrodes integrated with PDMS microfluidics. Biosensors and Bioelectron, 2004, 20(3), 509-517.
-
(2004)
Biosensors and Bioelectron
, vol.20
, Issue.3
, pp. 509-517
-
-
Pantoja, R.1
Nagarah, J.M.2
Starace, D.M.3
Melosh, N.A.4
Blunck, R.5
Bezanilla, F.6
Heath, J.R.7
-
55
-
-
12244299864
-
Upscaling and automation of electrophysiology: Toward high throughput screening in ion channel drug discovery
-
Asmild, M., Oswald, N., Krzywkowski, K. M., Friis, S., Jacobsen, R. B., Reuter, D., Taboryski, R., Kutchinsky, J., Vestergaard, R. K., and Schrøder, R. L. Upscaling and automation of electrophysiology: toward high throughput screening in ion channel drug discovery. Receptors and Channels, 2003, 9(1), 49-58.
-
(2003)
Receptors and Channels
, vol.9
, Issue.1
, pp. 49-58
-
-
Asmild, M.1
Oswald, N.2
Krzywkowski, K.M.3
Friis, S.4
Jacobsen, R.B.5
Reuter, D.6
Taboryski, R.7
Kutchinsky, J.8
Vestergaard, R.K.9
Schrøder, R.L.10
-
56
-
-
0036106307
-
Whole cell patch clamp recording performed on a planar glass chip
-
Fertig, N., Blick, R. H., and Behrends, J. C. Whole cell patch clamp recording performed on a planar glass chip. Biophys. J., 2002, 82(6), 3056-3062.
-
(2002)
Biophys. J.
, vol.82
, Issue.6
, pp. 3056-3062
-
-
Fertig, N.1
Blick, R.H.2
Behrends, J.C.3
-
57
-
-
0037236253
-
Microstructured apertures in planar glass substrates for ion channel research
-
Fertig, N., George, M., Klau, M., Meyer, C., Tilke, A., Sobotta, C., Blick, R. H., and Behrends, J. C. Microstructured apertures in planar glass substrates for ion channel research. Receptors and Channels, 2003, 9(1), 29-40.
-
(2003)
Receptors and Channels
, vol.9
, Issue.1
, pp. 29-40
-
-
Fertig, N.1
George, M.2
Klau, M.3
Meyer, C.4
Tilke, A.5
Sobotta, C.6
Blick, R.H.7
Behrends, J.C.8
-
58
-
-
0037232042
-
Cytocentering: A novel technique enabling automated cell-by-cell patch clamping with the CytoPatch- Chip
-
Stett, A., Burkhardt, C., Weber, U., van Stiphout, P., and Knott, T. Cytocentering: a novel technique enabling automated cell-by-cell patch clamping with the CytoPatch- Chip. Receptors and Channels, 2003, 9(1), 59.
-
(2003)
Receptors and Channels
, vol.9
, Issue.1
, pp. 59
-
-
Stett, A.1
Burkhardt, C.2
Weber, U.3
Van Stiphout, P.4
Knott, T.5
-
59
-
-
0041888478
-
IonworksTM Ht: A new high-throughput electrophysiology measurement platform
-
Schroeder, K., Neagle, B., Trezise, D. J., and Worley, J. IonworksTM Ht: A new high-throughput electrophysiology measurement platform. J. Biomolecular Screening, 2003, 8(1), 50.
-
(2003)
J. Biomolecular Screening
, vol.8
, Issue.1
, pp. 50
-
-
Schroeder, K.1
Neagle, B.2
Trezise, D.J.3
Worley, J.4
-
60
-
-
1942433697
-
A benchmark study with Seal Chip(tm) planar patch-clamp technology
-
Xu, J., Guia, A., Rothwarf, D., Huang, M., Sithiphong, K., Ouang, J., Tao, G., Wang, X., and Wu, L. A benchmark study with Seal Chip(tm) planar patch-clamp technology. Assay and Drug Development Technologies, 2003, 1(5), 675-684.
-
(2003)
Assay and Drug Development Technologies
, vol.1
, Issue.5
, pp. 675-684
-
-
Xu, J.1
Guia, A.2
Rothwarf, D.3
Huang, M.4
Sithiphong, K.5
Ouang, J.6
Tao, G.7
Wang, X.8
Wu, L.9
-
61
-
-
0037178198
-
Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells
-
Klemic, K. G., Klemic, J. F., Reed, M. A., and Sigworth, F. J. Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells. Biosensors and Bioelectronics, 2002, 17(6), 597-604.
-
(2002)
Biosensors and Bioelectronics
, vol.17
, Issue.6
, pp. 597-604
-
-
Klemic, K.G.1
Klemic, J.F.2
Reed, M.A.3
Sigworth, F.J.4
|