-
1
-
-
0028864281
-
Peripheral intravenous myocardial contrast echocardiography using a 2 % dodecafluoropentane emulsion: identification of myocardial risk area and infarct size in the canine model of ischemia
-
Grayburn PA, Erickson JM, Escobar J, et al. Peripheral intravenous myocardial contrast echocardiography using a 2 % dodecafluoropentane emulsion: identification of myocardial risk area and infarct size in the canine model of ischemia. J Am Coll Cardiol 1995; 26: 1340–7.
-
(1995)
J Am Coll Cardiol
, vol.26
, pp. 1340-1347
-
-
Grayburn, P.A.1
Erickson, J.M.2
Escobar, J.3
-
2
-
-
0029057163
-
Noninvasive identification of acute myocardial ischemia and reperfusion with contrast ultrasound using intravenous perfluoro-propane-exposed sonicated dextrose albumin
-
Porter TR, Xie F, Kricsfeld A, Kilzer K. Noninvasive identification of acute myocardial ischemia and reperfusion with contrast ultrasound using intravenous perfluoro-propane-exposed sonicated dextrose albumin. J Am Coll Cardiol 1995; 26: 33–40.
-
(1995)
J Am Coll Cardiol
, vol.26
, pp. 33-40
-
-
Porter, T.R.1
Xie, F.2
Kricsfeld, A.3
Kilzer, K.4
-
3
-
-
0030792911
-
Detection of coronary artery disease with myocardial contrast echocardiography: comparison with 99mTc-sestamibi single-photon emission computed tomography
-
Kaul S, Senior R, Dittrich H, Raval U, Khattar R, Lahiri A. Detection of coronary artery disease with myocardial contrast echocardiography: comparison with 99mTc-sestamibi single-photon emission computed tomography. Circulation 1997; 96: 785–92.
-
(1997)
Circulation
, vol.96
, pp. 785-792
-
-
Kaul, S.1
Senior, R.2
Dittrich, H.3
Raval, U.4
Khattar, R.5
Lahiri, A.6
-
4
-
-
0032212242
-
Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice: comparison with wall motion and technetium-99m sestamibi single-photon emission computed tomography. The nycomed NC100100 investigators
-
Marwick TH, Brunken R, Meland N, et al. Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice: comparison with wall motion and technetium-99m sestamibi single-photon emission computed tomography. The nycomed NC100100 investigators. J Am Coll Cardiol 1998; 32: 1260–9.
-
(1998)
J Am Coll Cardiol
, vol.32
, pp. 1260-1269
-
-
Marwick, T.H.1
Brunken, R.2
Meland, N.3
-
5
-
-
18844474104
-
Assessment of myocardial reperfusion by intravenous myocardial contrast echocardiography and coronary flow reserve after primary percutaneous transluminal coronary angioplasty [correction of angiography] in patients with acute myocardial infarction
-
Lepper W, Hoffmann R, Kamp O, et al. Assessment of myocardial reperfusion by intravenous myocardial contrast echocardiography and coronary flow reserve after primary percutaneous transluminal coronary angioplasty [correction of angiography] in patients with acute myocardial infarction. Circulation 2000; 101: 2368–74.
-
(2000)
Circulation
, vol.101
, pp. 2368-2374
-
-
Lepper, W.1
Hoffmann, R.2
Kamp, O.3
-
6
-
-
0034604241
-
Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress: comparison with 99mTc-sestamibi SPECT imaging
-
Heinle SK, Noblin J, Goree-Best P, et al. Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress: comparison with 99mTc-sestamibi SPECT imaging. Circulation 2000; 102: 55–60.
-
(2000)
Circulation
, vol.102
, pp. 55-60
-
-
Heinle, S.K.1
Noblin, J.2
Goree-Best, P.3
-
7
-
-
0034973421
-
Intravenous myocardial contrast echocardiography predicts recovery of dysyner-gic myocardium early after acute myocardial infarction
-
Swinburn JM, Lahiri A, Senior R. Intravenous myocardial contrast echocardiography predicts recovery of dysyner-gic myocardium early after acute myocardial infarction. J Am Coll Cardiol 2001; 38: 19–25.
-
(2001)
J Am Coll Cardiol
, vol.38
, pp. 19-25
-
-
Swinburn, J.M.1
Lahiri, A.2
Senior, R.3
-
8
-
-
0035499406
-
Full-motion pulse inversion power Doppler contrast echocardiography differentiates stunning from necrosis and predicts recovery of left ventricular function after acute myocardial infarction
-
Main ML, Magalski A, Chee NK, et al. Full-motion pulse inversion power Doppler contrast echocardiography differentiates stunning from necrosis and predicts recovery of left ventricular function after acute myocardial infarction. J Am Coll Cardiol 2001; 38: 1390–4.
-
(2001)
J Am Coll Cardiol
, vol.38
, pp. 1390-1394
-
-
Main, M.L.1
Magalski, A.2
Chee, N.K.3
-
9
-
-
0036188579
-
Correlation between myocardial perfusion abnormalities detected with intermittent imaging using intravenous perfluorocar-bon microbubbles and radioisotope imaging during high-dose dipyridamole stress echo
-
Ronderos RE, Boskis M, Chung N, et al. Correlation between myocardial perfusion abnormalities detected with intermittent imaging using intravenous perfluorocar-bon microbubbles and radioisotope imaging during high-dose dipyridamole stress echo. Clin Cardiol 2002; 25: 103–11.
-
(2002)
Clin Cardiol
, vol.25
, pp. 103-111
-
-
Ronderos, R.E.1
Boskis, M.2
Chung, N.3
-
10
-
-
0037420103
-
Detection of myocardial viability by contrast echocardiography in acute infarction predicts recovery of resting function and contractile reserve
-
Balcells E, Powers ER, Lepper W, et al. Detection of myocardial viability by contrast echocardiography in acute infarction predicts recovery of resting function and contractile reserve. J Am Coll Cardiol 2003; 41: 827–33.
-
(2003)
J Am Coll Cardiol
, vol.41
, pp. 827-833
-
-
Balcells, E.1
Powers, E.R.2
Lepper, W.3
-
11
-
-
0037563383
-
Assessment of right ventricular perfusion after right coronary artery occlusion by myocardial contrast echocardiography
-
Masugata H, Fujita N, Kondo I, et al. Assessment of right ventricular perfusion after right coronary artery occlusion by myocardial contrast echocardiography. J Am Coll Cardiol 2003; 41: 1823–30.
-
(2003)
J Am Coll Cardiol
, vol.41
, pp. 1823-1830
-
-
Masugata, H.1
Fujita, N.2
Kondo, I.3
-
12
-
-
0028882611
-
Transient myocardial contrast after initial exposure to diagnostic ultrasound pressures with minute doses of intravenously injected microbubbles. Demonstration and potential mechanisms
-
Porter TR, Xie F. Transient myocardial contrast after initial exposure to diagnostic ultrasound pressures with minute doses of intravenously injected microbubbles. Demonstration and potential mechanisms. Circulation 1995; 92: 2391–5.
-
(1995)
Circulation
, vol.92
, pp. 2391-2395
-
-
Porter, T.R.1
Xie, F.2
-
13
-
-
0032501992
-
Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
-
Wei K, Jayaweera AR, Firoozan S, et al. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 1998; 97: 473–83.
-
(1998)
Circulation
, vol.97
, pp. 473-483
-
-
Wei, K.1
Jayaweera, A.R.2
Firoozan, S.3
-
15
-
-
0034530172
-
Enhanced methods for visualizing myocardial perfusion with peripheral venous injection of levovist: application of triggered harmonic imaging and triggered harmonic power Doppler imaging techniques
-
Hirooka K, Miyatake K, Hanatani A, et al. Enhanced methods for visualizing myocardial perfusion with peripheral venous injection of levovist: application of triggered harmonic imaging and triggered harmonic power Doppler imaging techniques. Int J Card Imaging 2000;16: 233–46.
-
(2000)
Int J Card Imaging
, vol.16
, pp. 233-246
-
-
Hirooka, K.1
Miyatake, K.2
Hanatani, A.3
-
16
-
-
0033952843
-
Power Doppler harmonic imaging: a feasibility study of a new technique for the assessment of myocardial perfusion
-
Senior R, Kaul S, Soman P, Lahiri A. Power Doppler harmonic imaging: a feasibility study of a new technique for the assessment of myocardial perfusion. Am Heart J 2000; 139: 245–51.
-
(2000)
Am Heart J
, vol.139
, pp. 245-251
-
-
Senior, R.1
Kaul, S.2
Soman, P.3
Lahiri, A.4
-
17
-
-
0034687115
-
Assessment of coronary stenosis severity and transmural perfusion gradient by myocardial contrast echocardiography: comparison of gray-scale B-mode with power Doppler imaging
-
Masugata H, Cotter B, Peters B, et al. Assessment of coronary stenosis severity and transmural perfusion gradient by myocardial contrast echocardiography: comparison of gray-scale B-mode with power Doppler imaging. Circulation 2000; 102: 1427–33.
-
(2000)
Circulation
, vol.102
, pp. 1427-1433
-
-
Masugata, H.1
Cotter, B.2
Peters, B.3
-
18
-
-
0036582627
-
Microvascular rheology of Definity micro-bubbles after intra-arterial and intravenous administration
-
Lindner JR, Song J, Jayaweera AR, et al. Microvascular rheology of Definity micro-bubbles after intra-arterial and intravenous administration. J Am Soc Echocardiogr 2002; 15: 396–403.
-
(2002)
J Am Soc Echocardiogr
, vol.15
, pp. 396-403
-
-
Lindner, J.R.1
Song, J.2
Jayaweera, A.R.3
-
19
-
-
0027997151
-
Topology and dimensions of pig coronary capillary network
-
Kassab GS, Fung YC. Topology and dimensions of pig coronary capillary network. Am J Physiol 1994; 267: H319-H325.
-
(1994)
Am J Physiol
, vol.267
, pp. H319-H325
-
-
Kassab, G.S.1
Fung, Y.C.2
-
20
-
-
0030811703
-
Coronary and myocardial blood volumes: noninvasive tools to assess the coronary microcirculation?
-
Kaul S, Jayaweera AR. Coronary and myocardial blood volumes: noninvasive tools to assess the coronary microcirculation? Circulation 1997; 96: 719–24.
-
(1997)
Circulation
, vol.96
, pp. 719-724
-
-
Kaul, S.1
Jayaweera, A.R.2
-
21
-
-
1642580536
-
Microvasculature in acute myocardial ischemia: Part I. Evolving concepts in pathophysiology, diagnosis, and treatment
-
Kaul S, Ito H. Microvasculature in acute myocardial ischemia: Part I. Evolving concepts in pathophysiology, diagnosis, and treatment. Circulation 2004; 109: 310–5.
-
(2004)
Circulation
, vol.109
, pp. 310-315
-
-
Kaul, S.1
Ito, H.2
-
22
-
-
0032480764
-
Assessment of transmural distribution of myocardial perfusion with contrast echocardiography
-
Linka AZ, Sklenar J, Wei K et al. Assessment of transmural distribution of myocardial perfusion with contrast echocardiography. Circulation 1998; 98: 1912–20.
-
(1998)
Circulation
, vol.98
, pp. 1912-1920
-
-
Linka, A.Z.1
Sklenar, J.2
Wei, K.3
-
23
-
-
0035967485
-
Noninvasive quantification of coronary blood flow reserve in humans using myocardial contrast echocardiography
-
Wei K, Ragosta M, Thorpe J et al. Noninvasive quantification of coronary blood flow reserve in humans using myocardial contrast echocardiography. Circulation 2001; 103: 2560–5.
-
(2001)
Circulation
, vol.103
, pp. 2560-2565
-
-
Wei, K.1
Ragosta, M.2
Thorpe, J.3
-
24
-
-
0016315064
-
The “no-reflow” phenomenon after temporary coronary occlusion in the dog
-
Kloner RA, Ganote CE, Jennings RB. The “no-reflow” phenomenon after temporary coronary occlusion in the dog. J Clin Invest 1974; 54: 1496–1508.
-
(1974)
J Clin Invest
, vol.54
, pp. 1496-1508
-
-
Kloner, R.A.1
Ganote, C.E.2
Jennings, R.B.3
-
25
-
-
0026546167
-
Lack of myocardial perfusion immediately after successful thrombolysis: a predictor of poor recovery of left ventricular function in anterior myocardial infarction
-
Ito H, Tomooka T, Sakai N, et al. Lack of myocardial perfusion immediately after successful thrombolysis: a predictor of poor recovery of left ventricular function in anterior myocardial infarction. Circulation 1992; 85:1 699–705.
-
(1992)
Circulation
, vol.85
, Issue.1
, pp. 699-705
-
-
Ito, H.1
Tomooka, T.2
Sakai, N.3
-
26
-
-
0030034531
-
Clinical implications of the “no reflow” phenomenon: a predictor of complications and left ventricular remodeling in reperfused anterior wall myocardial infarction
-
Ito H, Maruyama A, Iwakura K, et al. Clinical implications of the “no reflow” phenomenon: a predictor of complications and left ventricular remodeling in reperfused anterior wall myocardial infarction. Circulation 1996; 93: 223–8.
-
(1996)
Circulation
, vol.93
, pp. 223-228
-
-
Ito, H.1
Maruyama, A.2
Iwakura, K.3
-
27
-
-
2442466974
-
Incremental value of parametric quantitative assessment of myocardial perfusion by triggered low-power myocardial contrast echocardiography
-
Yu EHC, Skyba DM, Leong-Poi H, et al. Incremental value of parametric quantitative assessment of myocardial perfusion by triggered low-power myocardial contrast echocardiography. J Am Coll Cardiol 2004; 43: 1807–13.
-
(2004)
J Am Coll Cardiol
, vol.43
, pp. 1807-1813
-
-
Yu, E.H.C.1
Skyba, D.M.2
Leong-Poi, H.3
-
28
-
-
0027310229
-
Quantitative echo contrast concentration measurement by Doppler sonography
-
Schwarz KQ, Bezante GP, Chen X, et al. Quantitative echo contrast concentration measurement by Doppler sonography. Ultrasound Med Biol 1993; 19: 289–97.
-
(1993)
Ultrasound Med Biol
, vol.19
, pp. 289-297
-
-
Schwarz, K.Q.1
Bezante, G.P.2
Chen, X.3
-
29
-
-
0028129040
-
Quantification of myocardial perfusion with myocardial contrast echocardiography during left atrial injection of contrast. Implications for venous injection
-
Skyba DM, Jayaweera AR, Goodman NC, et al. Quantification of myocardial perfusion with myocardial contrast echocardiography during left atrial injection of contrast. Implications for venous injection. Circulation 1994; 90: 1513–21.
-
(1994)
Circulation
, vol.90
, pp. 1513-1521
-
-
Skyba, D.M.1
Jayaweera, A.R.2
Goodman, N.C.3
-
30
-
-
2442499580
-
Myocardial contrast echocardiography with a new calibration method can estimate myocardial viability in patients with myocardial infarction
-
Yano A, Ito H, Iwakura K, et al. Myocardial contrast echocardiography with a new calibration method can estimate myocardial viability in patients with myocardial infarction. J Am Coll Cardiol 2004; 43, 1799–1806.
-
(2004)
J Am Coll Cardiol
, vol.43
, pp. 1799-1806
-
-
Yano, A.1
Ito, H.2
Iwakura, K.3
-
31
-
-
0024629019
-
Myocardial blood flow estimated by synchronous, multislice, high-speed computed tomography
-
Wang T, We X, Chung N. Myocardial blood flow estimated by synchronous, multislice, high-speed computed tomography. IEEE Trans Med Imaging 1989; 8: 70–77.
-
(1989)
IEEE Trans Med Imaging
, vol.8
, pp. 70-77
-
-
Wang, T.1
We, X.2
Chung, N.3
-
32
-
-
0028580408
-
Morphometry of pig coronary venous system
-
Kassab GS, Lin DH, Fung YC. Morphometry of pig coronary venous system. Am J Physiol 1994; 267: H2100-H2113.
-
(1994)
Am J Physiol
, vol.267
, pp. H2100-H2113
-
-
Kassab, G.S.1
Lin, D.H.2
Fung, Y.C.3
-
33
-
-
0018535017
-
Microvascular hematocrit and red cell flow in resting and contracting striated muscle
-
Klitzman B, Duling BR. Microvascular hematocrit and red cell flow in resting and contracting striated muscle. Am J Physiol 1979; 237: H481-H490.
-
(1979)
Am J Physiol
, vol.237
, pp. H481-H490
-
-
Klitzman, B.1
Duling, B.R.2
-
34
-
-
0020391936
-
Direct measurement of microves-sel hematocrit, red cell flux, velocity, and transit time
-
Sarelius IH, Duling BR. Direct measurement of microves-sel hematocrit, red cell flux, velocity, and transit time. Am J Physiol 1982; 243: H1018-H1026.
-
(1982)
Am J Physiol
, vol.243
, pp. H1018-H1026
-
-
Sarelius, I.H.1
Duling, B.R.2
-
35
-
-
0028358143
-
Microvascular compression during myocardial ischemia: mechanistic basis for no-reflow phenomenon
-
Manciet LH, Poole DC, McDonagh PF, et al. Microvascular compression during myocardial ischemia: mechanistic basis for no-reflow phenomenon. Am J Physiol 1994; 266: H1541-H1550.
-
(1994)
Am J Physiol
, vol.266
, pp. H1541-H1550
-
-
Manciet, L.H.1
Poole, D.C.2
McDonagh, P.F.3
-
36
-
-
0035182311
-
Assessment of no-reflow phenomenon after acute myocardial infarction with harmonic angiography and intravenous pump infusion with Levovist: comparison with intracoronary contrast injection
-
Agati L, Funaro S, Bilotta F. Assessment of no-reflow phenomenon after acute myocardial infarction with harmonic angiography and intravenous pump infusion with Levovist: comparison with intracoronary contrast injection. J Am Soc Echocardiogr 2001; 14: 773–81.
-
(2001)
J Am Soc Echocardiogr
, vol.14
, pp. 773-781
-
-
Agati, L.1
Funaro, S.2
Bilotta, F.3
-
37
-
-
0032127747
-
Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion?
-
Wei K, Jayaweera AR, Firoozan S, et al. Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion? J Am Coll Cardiol 1998; 32: 252–260.
-
(1998)
J Am Coll Cardiol
, vol.32
, pp. 252-260
-
-
Wei, K.1
Jayaweera, A.R.2
Firoozan, S.3
-
38
-
-
0035810910
-
Comparative value of dobutamine and adenosine stress in the detection of coronary stenosis with myocardial contrast echoacardiog-raphy
-
Lafitte S, Masugata H, Peters B, et al. Comparative value of dobutamine and adenosine stress in the detection of coronary stenosis with myocardial contrast echoacardiog-raphy. Circulation 2001; 103: 2724–30.
-
(2001)
Circulation
, vol.103
, pp. 2724-2730
-
-
Lafitte, S.1
Masugata, H.2
Peters, B.3
-
39
-
-
0037637665
-
Quantitative assessment of coronary stenosis by harmonic power Doppler with a simple pulsing sequence and vasodilator stress in patients
-
Takagi Y, Ohmori K, Yukiiri K, et al. Quantitative assessment of coronary stenosis by harmonic power Doppler with a simple pulsing sequence and vasodilator stress in patients. J Am Coll Cardiol 2003; 41: 2060–70.
-
(2003)
J Am Coll Cardiol
, vol.41
, pp. 2060-2070
-
-
Takagi, Y.1
Ohmori, K.2
Yukiiri, K.3
|