메뉴 건너뛰기




Volumn 16, Issue 4, 2000, Pages 233-246

Enhanced methods for visualizing myocardial perfusion with peripheral venous injection of Levovist®: Application of triggered harmonic imaging and triggered harmonic power Doppler imaging techniques

Author keywords

Harmonic imaging; Microbubbles; Myocardial contrast echocardiography; Peripheral venous injection; Power Doppler

Indexed keywords

SHU 508;

EID: 0034530172     PISSN: 01679899     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1026592629450     Document Type: Article
Times cited : (9)

References (37)
  • 12
    • 0026546167 scopus 로고
    • Lack of myocardial perfusion immediately after successful thrombolysis: A predictor of poor recovery of left ventricular function in anterior myocardial infarction
    • (1992) Circulation , vol.85 , pp. 1699-1705
    • Ito, H.1    Tomooka, T.2    Sakai, N.3
  • 13
    • 0028855190 scopus 로고
    • Visually discernible myocardial echocardiographic contrast after intravenous injection of sonicated dextrose albumin microbubbles containing high molecular weight, less soluble gases
    • (1995) J Am Coll Cardiol , vol.25 , pp. 509-515
    • Porter, T.R.1    Xie, F.2
  • 14
    • 0029956720 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography: Reliable, safe, and efficacious myocardial perfusion assessment after intravenous injections of a new echocardiographic contrast agent
    • (1996) Am Heart J , vol.132 , pp. 871-881
    • Meza, M.1    Greener, Y.2    Hunt, R.3
  • 15
    • 0030059706 scopus 로고    scopus 로고
    • Harmonic imaging with ultrasound contrast agents
    • (1996) Clin Radiol , vol.51 , Issue.SUPPL. 1 , pp. 50-55
    • Burns, P.N.1
  • 20
    • 0028882611 scopus 로고
    • Transient myocardial contrast after initial exposure to diagnostic ultrasound pressures with minute doses of intravenously injected microbubbles. Demonstration and potential mechanisms
    • (1995) Circulation , vol.92 , pp. 2391-2395
    • Porter, T.R.1    Xie, F.2
  • 32
    • 0027429973 scopus 로고
    • Opacification and border delineation improvement in patients with suboptimal endocardial border definition in routine echocardiography: Results of the Phase III Albunex Multicenter Trial
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1494-1500
    • Crouse, L.J.1    Cheirif, J.2    Hanly, D.E.3
  • 34
    • 0032212242 scopus 로고    scopus 로고
    • Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice: Comparison with wall motion and technetium-99m sestamibi single-photon emission computed tomography. The Nycomed NC100100 Investigators
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1260-1269
    • Marwick, T.H.1    Brunken, R.2    Meland, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.