메뉴 건너뛰기




Volumn 30, Issue 5, 2010, Pages 328-332

Male-female differences in forearm skin tissue dielectric constant

Author keywords

Lymphoedema; Oedema; Permittivity; Skin water; Tissue water

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; DIELECTRIC CONSTANT; FEMALE; FOREARM; HUMAN; HUMAN EXPERIMENT; MALE; NORMAL HUMAN; PRIORITY JOURNAL; SEX DIFFERENCE; SKIN CONDUCTANCE; SKINFOLD THICKNESS; TISSUE WATER;

EID: 77955825197     PISSN: 14750961     EISSN: 1475097X     Source Type: Journal    
DOI: 10.1111/j.1475-097X.2010.00946.x     Document Type: Article
Times cited : (28)

References (34)
  • 1
    • 0030560716 scopus 로고    scopus 로고
    • Noninvasive method for measuring the electrical properties of deep tissues using an open-ended coaxial probe
    • Aimoto A, Matsumoto T. Noninvasive method for measuring the electrical properties of deep tissues using an open-ended coaxial probe. Med Eng Phys 1996, 18:641-646.
    • (1996) Med Eng Phys , vol.18 , pp. 641-646
    • Aimoto, A.1    Matsumoto, T.2
  • 2
    • 0031929054 scopus 로고    scopus 로고
    • Measurement of dielectric properties of subcutaneous fat with open-ended coaxial sensors
    • Alanen E, Lahtinen T, Nuutinen J. Measurement of dielectric properties of subcutaneous fat with open-ended coaxial sensors. Phys Med Biol 1998a, 43:475-485.
    • (1998) Phys Med Biol , vol.43 , pp. 475-485
    • Alanen, E.1    Lahtinen, T.2    Nuutinen, J.3
  • 3
    • 0032190035 scopus 로고    scopus 로고
    • Variational formulation of open-ended coaxial line in contact with layered biological medium
    • Alanen E, Lahtinen T, Nuutinen J. Variational formulation of open-ended coaxial line in contact with layered biological medium. IEEE Trans Biomed Eng 1998b, 45:1241-1248.
    • (1998) IEEE Trans Biomed Eng , vol.45 , pp. 1241-1248
    • Alanen, E.1    Lahtinen, T.2    Nuutinen, J.3
  • 4
    • 0032769203 scopus 로고    scopus 로고
    • Penetration of electromagnetic fields of an open-ended coaxial probe between 1 MHz and 1 GHz in dielectric skin measurements
    • Alanen E, Lahtinen T, Nuutinen J. Penetration of electromagnetic fields of an open-ended coaxial probe between 1 MHz and 1 GHz in dielectric skin measurements. Phys Med Biol 1999, 44:N169-N176.
    • (1999) Phys Med Biol , vol.44
    • Alanen, E.1    Lahtinen, T.2    Nuutinen, J.3
  • 6
    • 0035035928 scopus 로고    scopus 로고
    • The use of high-frequency diagnostic ultrasound to investigate the effect of hormone replacement therapy on skin thickness
    • Chen L, Dyson M, Rymer J, Bolton PA, Young SR. The use of high-frequency diagnostic ultrasound to investigate the effect of hormone replacement therapy on skin thickness. Skin Res Technol 2001, 7:95-97.
    • (2001) Skin Res Technol , vol.7 , pp. 95-97
    • Chen, L.1    Dyson, M.2    Rymer, J.3    Bolton, P.A.4    Young, S.R.5
  • 8
    • 0024572263 scopus 로고
    • Dielectric properties of tissues and biological materials: a critical review
    • Foster KR, Schwan HP. Dielectric properties of tissues and biological materials: a critical review. Crit Rev Biomed Eng 1989, 17:25-104.
    • (1989) Crit Rev Biomed Eng , vol.17 , pp. 25-104
    • Foster, K.R.1    Schwan, H.P.2
  • 9
    • 0029909341 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
    • Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol 1996a, 41:2251-2269.
    • (1996) Phys Med Biol , vol.41 , pp. 2251-2269
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 10
    • 0029957193 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues
    • Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Phys Med Biol 1996b, 41:2271-2293.
    • (1996) Phys Med Biol , vol.41 , pp. 2271-2293
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 11
    • 0031798258 scopus 로고    scopus 로고
    • Quantitative evaluation of chronological ageing and photoageing in vivo: studies on skin echogenicity and thickness
    • Gniadecka M, Jemec GB. Quantitative evaluation of chronological ageing and photoageing in vivo: studies on skin echogenicity and thickness. Br J Dermatol 1998, 139:815-821.
    • (1998) Br J Dermatol , vol.139 , pp. 815-821
    • Gniadecka, M.1    Jemec, G.B.2
  • 12
    • 0029956972 scopus 로고    scopus 로고
    • Assessment of dermal water by high-frequency ultrasound: comparative studies with nuclear magnetic resonance
    • Gniadecka M, Quistorff B. Assessment of dermal water by high-frequency ultrasound: comparative studies with nuclear magnetic resonance. Br J Dermatol 1996, 135:218-224.
    • (1996) Br J Dermatol , vol.135 , pp. 218-224
    • Gniadecka, M.1    Quistorff, B.2
  • 13
    • 0037499523 scopus 로고    scopus 로고
    • Changes in abdominal subcutaneous fat water content with rapid weight loss and long-term weight maintenance in abdominally obese men and women
    • Laaksonen DE, Nuutinen J, Lahtinen T, Rissanen A, Niskanen LK. Changes in abdominal subcutaneous fat water content with rapid weight loss and long-term weight maintenance in abdominally obese men and women. Int J Obes Relat Metab Disord 2003, 27:677-683.
    • (2003) Int J Obes Relat Metab Disord , vol.27 , pp. 677-683
    • Laaksonen, D.E.1    Nuutinen, J.2    Lahtinen, T.3    Rissanen, A.4    Niskanen, L.K.5
  • 15
    • 34547102517 scopus 로고    scopus 로고
    • Echographic measurement of skin thickness in adults by high frequency ultrasound to assess the appropriate microneedle length for intradermal delivery of vaccines
    • Laurent A, Mistretta F, Bottigioli D, Dahel K, Goujon C, Nicolas JF, Hennino A, Laurent PE. Echographic measurement of skin thickness in adults by high frequency ultrasound to assess the appropriate microneedle length for intradermal delivery of vaccines. Vaccine 2007, 25:6423-6430.
    • (2007) Vaccine , vol.25 , pp. 6423-6430
    • Laurent, A.1    Mistretta, F.2    Bottigioli, D.3    Dahel, K.4    Goujon, C.5    Nicolas, J.F.6    Hennino, A.7    Laurent, P.E.8
  • 16
    • 0036700667 scopus 로고    scopus 로고
    • Skin thickness of Korean adults
    • Lee Y, Hwang K. Skin thickness of Korean adults. Surg Radiol Anat 2002, 24:183-189.
    • (2002) Surg Radiol Anat , vol.24 , pp. 183-189
    • Lee, Y.1    Hwang, K.2
  • 17
    • 34547871619 scopus 로고    scopus 로고
    • Assessing local tissue edema in postmastectomy lymphedema
    • Mayrovitz HN. Assessing local tissue edema in postmastectomy lymphedema. Lymphology 2007, 40:87-94.
    • (2007) Lymphology , vol.40 , pp. 87-94
    • Mayrovitz, H.N.1
  • 18
    • 69249088181 scopus 로고    scopus 로고
    • Assessing lymphedema by tissue indentation force and local tissue water
    • Mayrovitz HN. Assessing lymphedema by tissue indentation force and local tissue water. Lymphology 2009a, 42:88-98.
    • (2009) Lymphology , vol.42 , pp. 88-98
    • Mayrovitz, H.N.1
  • 19
    • 67650851466 scopus 로고    scopus 로고
    • The standard of care for lymphedema: current concepts and physiological considerations
    • Mayrovitz HN. The standard of care for lymphedema: current concepts and physiological considerations. Lymphat Res Biol 2009b, 7:101-108.
    • (2009) Lymphat Res Biol , vol.7 , pp. 101-108
    • Mayrovitz, H.N.1
  • 20
    • 73549106115 scopus 로고    scopus 로고
    • Local tissue water assessed by measuring forearm skin dielectric constant: dependence on measurement depth, age and body mass index
    • Mayrovitz HN. Local tissue water assessed by measuring forearm skin dielectric constant: dependence on measurement depth, age and body mass index. Skin Res Technol 2010, 16:16-22.
    • (2010) Skin Res Technol , vol.16 , pp. 16-22
    • Mayrovitz, H.N.1
  • 22
    • 49849106104 scopus 로고    scopus 로고
    • Local tissue water assessed by tissue dielectric constant: anatomical site and depth dependence in women prior to breast cancer treatment-related surgery
    • Mayrovitz HN, Davey S, Shapiro E. Local tissue water assessed by tissue dielectric constant: anatomical site and depth dependence in women prior to breast cancer treatment-related surgery. Clin Physiol Funct Imaging 2008a, 28:337-342.
    • (2008) Clin Physiol Funct Imaging , vol.28 , pp. 337-342
    • Mayrovitz, H.N.1    Davey, S.2    Shapiro, E.3
  • 23
    • 47749123002 scopus 로고    scopus 로고
    • Localized tissue water changes accompanying one manual lymphatic drainage (MLD) therapy session assessed by changes in tissue dielectric constant inpatients with lower extremity lymphedema
    • Mayrovitz HN, Davey S, Shapiro E. Localized tissue water changes accompanying one manual lymphatic drainage (MLD) therapy session assessed by changes in tissue dielectric constant inpatients with lower extremity lymphedema. Lymphology 2008b, 41:87-92.
    • (2008) Lymphology , vol.41 , pp. 87-92
    • Mayrovitz, H.N.1    Davey, S.2    Shapiro, E.3
  • 24
    • 60149089420 scopus 로고    scopus 로고
    • Suitability of single tissue dielectric constant measurements to assess local tissue water in normal and lymphedematous skin
    • Mayrovitz HN, Davey S, Shapiro E. Suitability of single tissue dielectric constant measurements to assess local tissue water in normal and lymphedematous skin. Clin Physiol Funct Imaging 2009a, 29:123-127.
    • (2009) Clin Physiol Funct Imaging , vol.29 , pp. 123-127
    • Mayrovitz, H.N.1    Davey, S.2    Shapiro, E.3
  • 25
    • 70449465419 scopus 로고    scopus 로고
    • Local tissue water in at-risk and contralateral forearms of women with and without breast cancer treatment-related lymphedema
    • Mayrovitz HN, Weingrad DN, Davey S. Local tissue water in at-risk and contralateral forearms of women with and without breast cancer treatment-related lymphedema. Lymphat Res Biol 2009b, 7:153-158.
    • (2009) Lymphat Res Biol , vol.7 , pp. 153-158
    • Mayrovitz, H.N.1    Weingrad, D.N.2    Davey, S.3
  • 28
    • 2342520134 scopus 로고    scopus 로고
    • Validation of a new dielectric device to assess changes of tissue water in skin and subcutaneous fat
    • Nuutinen J, Ikaheimo R, Lahtinen T. Validation of a new dielectric device to assess changes of tissue water in skin and subcutaneous fat. Physiol Meas 2004, 25:447-454.
    • (2004) Physiol Meas , vol.25 , pp. 447-454
    • Nuutinen, J.1    Ikaheimo, R.2    Lahtinen, T.3
  • 29
    • 0038777530 scopus 로고    scopus 로고
    • Dielectric constant of skin and subcutaneous fat to assess fluid changes after cardiac surgery
    • Petaja L, Nuutinen J, Uusaro A, Lahtinen T, Ruokonen E. Dielectric constant of skin and subcutaneous fat to assess fluid changes after cardiac surgery. Physiol Meas 2003, 24:383-390.
    • (2003) Physiol Meas , vol.24 , pp. 383-390
    • Petaja, L.1    Nuutinen, J.2    Uusaro, A.3    Lahtinen, T.4    Ruokonen, E.5
  • 33
    • 0019999533 scopus 로고
    • Measurement of radio frequency permittivity of biological tissues with an open-ended coaxial line: Part II - Experimental Results
    • Stuchly MA, Athey TW, Samaras GM, Taylor G. Measurement of radio frequency permittivity of biological tissues with an open-ended coaxial line: Part II - Experimental Results. IEEE Trans Microw Theory Tech 1982, 30:87-92.
    • (1982) IEEE Trans Microw Theory Tech , vol.30 , pp. 87-92
    • Stuchly, M.A.1    Athey, T.W.2    Samaras, G.M.3    Taylor, G.4
  • 34
    • 0023863210 scopus 로고
    • Electron probe analysis of human skin: determination of the water concentration profile
    • Warner RR, Myers MC, Taylor DA. Electron probe analysis of human skin: determination of the water concentration profile. J Invest Dermatol 1988, 90:218-224.
    • (1988) J Invest Dermatol , vol.90 , pp. 218-224
    • Warner, R.R.1    Myers, M.C.2    Taylor, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.