메뉴 건너뛰기




Volumn 40, Issue 2, 2007, Pages 87-94

Assessing local tissue edema in postmastectomy lymphedema

Author keywords

Arm lymphedema; Breast cancer; Dielectric constant; Edema measurement; Lymphedema measurement; Lymphedema treatment; Tissue water

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; DIELECTRIC CONSTANT; FEMALE; HUMAN; LYMPHEDEMA; MASTECTOMY; MEASUREMENT; POSTMENOPAUSE; POSTOPERATIVE COMPLICATION; PREMENOPAUSE; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; STATISTICAL SIGNIFICANCE;

EID: 34547871619     PISSN: 00247766     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (79)

References (25)
  • 1
    • 0028261140 scopus 로고
    • Measuring and representing peripheral oedema and its alterations
    • Casley-Smith, JR: Measuring and representing peripheral oedema and its alterations. Lymphology 27 (1994), 56-70.
    • (1994) Lymphology , vol.27 , pp. 56-70
    • Casley-Smith, J.R.1
  • 2
    • 0037308284 scopus 로고    scopus 로고
    • Concurrent validity of upper-extremity volume estimates: Comparison of calculated volume derived from girth measurements and water displacement volume
    • Karges, JR, BE Mark, SJ Stikeleather, et al: Concurrent validity of upper-extremity volume estimates: comparison of calculated volume derived from girth measurements and water displacement volume. Phys. Ther. 83 (2003), 134-145.
    • (2003) Phys. Ther , vol.83 , pp. 134-145
    • Karges, J.R.1    Mark, B.E.2    Stikeleather, S.J.3
  • 3
    • 0041336978 scopus 로고    scopus 로고
    • Limb volume estimates based on limb elliptical vs. circular cross section models
    • Mayrovitz, HN: Limb volume estimates based on limb elliptical vs. circular cross section models. Lymphology 36 (2003), 140-143.
    • (2003) Lymphology , vol.36 , pp. 140-143
    • Mayrovitz, H.N.1
  • 4
    • 33746016601 scopus 로고    scopus 로고
    • Hand volume estimates based on a geometric algorithm in comparison to water displacement
    • Mayrovitz, HN, N Sims, CJ Hill, et al: Hand volume estimates based on a geometric algorithm in comparison to water displacement. Lymphology 39 (2006), 95-103.
    • (2006) Lymphology , vol.39 , pp. 95-103
    • Mayrovitz, H.N.1    Sims, N.2    Hill, C.J.3
  • 5
    • 15244351296 scopus 로고    scopus 로고
    • Foot volume estimates based on a geometric algorithm in comparison to water displacement
    • Mayrovitz, HN, N Sims, B Litwin, et al: Foot volume estimates based on a geometric algorithm in comparison to water displacement. Lymphology 38 (2005), 20-27.
    • (2005) Lymphology , vol.38 , pp. 20-27
    • Mayrovitz, H.N.1    Sims, N.2    Litwin, B.3
  • 6
    • 7044264450 scopus 로고    scopus 로고
    • Validity and intra- and interobserver reliability of an indirect volume measurements in patients with upper extremity lymphedema
    • Meijer, RS, JS Rietman, JH Geertzen, et al: Validity and intra- and interobserver reliability of an indirect volume measurements in patients with upper extremity lymphedema. Lymphology 37 (2004), 127-133.
    • (2004) Lymphology , vol.37 , pp. 127-133
    • Meijer, R.S.1    Rietman, J.S.2    Geertzen, J.H.3
  • 7
    • 0036898769 scopus 로고    scopus 로고
    • Upper-extremity volume measurements in women with lymphedema: A comparison of measurements obtained via water displacement with geometrically determined volume
    • Sander, AP, NM Hajer, K Hemenway, et al: Upper-extremity volume measurements in women with lymphedema: A comparison of measurements obtained via water displacement with geometrically determined volume. Phys. Ther. 82 (2002), 1201-1212.
    • (2002) Phys. Ther , vol.82 , pp. 1201-1212
    • Sander, A.P.1    Hajer, N.M.2    Hemenway, K.3
  • 8
    • 0034335232 scopus 로고    scopus 로고
    • Assessment of limb volume by manual and automated methods in patients with limb edema or lymphedema
    • Mayrovitz, HN, N Sims, J Macdonald: Assessment of limb volume by manual and automated methods in patients with limb edema or lymphedema. Adv. Skin Wound Care 13 (2000), 272-276.
    • (2000) Adv. Skin Wound Care , vol.13 , pp. 272-276
    • Mayrovitz, H.N.1    Sims, N.2    Macdonald, J.3
  • 9
    • 0036973532 scopus 로고    scopus 로고
    • Combined opto-electronic perometry and bioimpedance to measure objectively the effectiveness of a new treatment intervention for chronic secondary leg lymphedema
    • Moseley, A, N Piller, C Carati: Combined opto-electronic perometry and bioimpedance to measure objectively the effectiveness of a new treatment intervention for chronic secondary leg lymphedema. Lymphology 35 (2002), 136-143.
    • (2002) Lymphology , vol.35 , pp. 136-143
    • Moseley, A.1    Piller, N.2    Carati, C.3
  • 10
    • 0030612630 scopus 로고    scopus 로고
    • Validation of an optoelectronic limb volumeter (Perometer)
    • Stanton, AW, JW Northfield, B Holroyd, et al: Validation of an optoelectronic limb volumeter (Perometer). Lymphology 30 (1997), 77-97.
    • (1997) Lymphology , vol.30 , pp. 77-97
    • Stanton, A.W.1    Northfield, J.W.2    Holroyd, B.3
  • 11
    • 0030453479 scopus 로고    scopus 로고
    • Infrared optoelectronic volumetry, the ideal way to measure limb volume
    • Tierney, S, M Aslam, K Rennie, et al: Infrared optoelectronic volumetry, the ideal way to measure limb volume. Eur. J. Vasc Endovasc. Surg. 12 (1996), 412-417.
    • (1996) Eur. J. Vasc Endovasc. Surg , vol.12 , pp. 412-417
    • Tierney, S.1    Aslam, M.2    Rennie, K.3
  • 12
    • 0034973709 scopus 로고    scopus 로고
    • Early diagnosis of lymphedema using multiple frequency bioimpedance
    • Cornish, BH, M Chapman, C Hirst, et al: Early diagnosis of lymphedema using multiple frequency bioimpedance. Lymphology 34 (2001), 2-11.
    • (2001) Lymphology , vol.34 , pp. 2-11
    • Cornish, B.H.1    Chapman, M.2    Hirst, C.3
  • 13
    • 0036170540 scopus 로고    scopus 로고
    • A new technique for the quantification of peripheral edema with application in both unilateral and bilateral cases
    • Cornish, BH, BJ Thomas, LC Ward, et al: A new technique for the quantification of peripheral edema with application in both unilateral and bilateral cases. Angiology 53 (2002), 41-47.
    • (2002) Angiology , vol.53 , pp. 41-47
    • Cornish, B.H.1    Thomas, B.J.2    Ward, L.C.3
  • 14
    • 33645799245 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis: Proven utility in lymphedema risk assessment and therapeutic monitoring
    • Ward, LC: Bioelectrical impedance analysis: proven utility in lymphedema risk assessment and therapeutic monitoring. Lymphat. Res. Biol. 4 (2006), 51-56.
    • (2006) Lymphat. Res. Biol , vol.4 , pp. 51-56
    • Ward, L.C.1
  • 15
    • 2342520134 scopus 로고    scopus 로고
    • Validation of a new dielectric device to assess changes of tissue water in skin and subcutaneous fat
    • Nuutinen, J, R Ikaheimo, T Lahtinen: Validation of a new dielectric device to assess changes of tissue water in skin and subcutaneous fat. Physiol. Meas. 25 (2004), 447-454.
    • (2004) Physiol. Meas , vol.25 , pp. 447-454
    • Nuutinen, J.1    Ikaheimo, R.2    Lahtinen, T.3
  • 16
    • 0030560716 scopus 로고    scopus 로고
    • Noninvasive method for measuring the electrical properties of deep tissues using an open-ended coaxial probe
    • Aimoto, A, T Matsumoto: Noninvasive method for measuring the electrical properties of deep tissues using an open-ended coaxial probe. Med. Eng. Phys. 18 (1996), 641-646.
    • (1996) Med. Eng. Phys , vol.18 , pp. 641-646
    • Aimoto, A.1    Matsumoto, T.2
  • 17
    • 0031929054 scopus 로고    scopus 로고
    • Measurement of dielectric properties of subcutaneous fat with open-ended coaxial sensors
    • Alanen, E, T Lahtinen, J Nuutinen: Measurement of dielectric properties of subcutaneous fat with open-ended coaxial sensors. Phys. Med. Biol. 43 (1998), 475-485.
    • (1998) Phys. Med. Biol , vol.43 , pp. 475-485
    • Alanen, E.1    Lahtinen, T.2    Nuutinen, J.3
  • 18
    • 0032190035 scopus 로고    scopus 로고
    • Variational formulation of open-ended coaxial line in contact with layered biological medium
    • Alanen, E, T Lahtinen, J Nuutinen: Variational formulation of open-ended coaxial line in contact with layered biological medium. IEEE Trans. Biomed. Eng. 45 (1998), 1241-1248.
    • (1998) IEEE Trans. Biomed. Eng , vol.45 , pp. 1241-1248
    • Alanen, E.1    Lahtinen, T.2    Nuutinen, J.3
  • 19
    • 0032769203 scopus 로고    scopus 로고
    • Penetration of electromagnetic fields of an open-ended coaxial probe between 1 MHz and 1 GHz in dielectric skin measurements
    • Alanen, E, T Lahtinen, J Nuutinen: Penetration of electromagnetic fields of an open-ended coaxial probe between 1 MHz and 1 GHz in dielectric skin measurements. Phys. Med. Biol. 44 (1999), N169-176.
    • (1999) Phys. Med. Biol , vol.44
    • Alanen, E.1    Lahtinen, T.2    Nuutinen, J.3
  • 20
    • 0019999533 scopus 로고
    • Measurement of radio frequency permittivity of biological tissues with an open-ended coaxial line: Part II - Experimental Results
    • Stuchly, MA, TW Athey, GM Samaras, et al: Measurement of radio frequency permittivity of biological tissues with an open-ended coaxial line: Part II - Experimental Results. IEEE Trans Microwave Theory and Techniques 30 (1982), 87-92.
    • (1982) IEEE Trans Microwave Theory and Techniques , vol.30 , pp. 87-92
    • Stuchly, M.A.1    Athey, T.W.2    Samaras, G.M.3
  • 21
    • 0031800667 scopus 로고    scopus 로고
    • A dielectric method for measuring early and late reactions in irradiated human skin
    • Nuutinen, J, T Lahtinen, M Turunen, et al: A dielectric method for measuring early and late reactions in irradiated human skin. Radiother. Oncol. 47 (1998), 249-254.
    • (1998) Radiother. Oncol , vol.47 , pp. 249-254
    • Nuutinen, J.1    Lahtinen, T.2    Turunen, M.3
  • 22
    • 34547864734 scopus 로고    scopus 로고
    • A method to measure local tissue water and its application to evaluate breast cancer treatment-related lymphedema
    • Amelia Island, Florida: ASME 2006
    • Mayrovitz, HN. A method to measure local tissue water and its application to evaluate breast cancer treatment-related lymphedema. In: Bioengineering; 2006, Amelia Island, Florida: ASME 2006.
    • Bioengineering; 2006
    • Mayrovitz, H.N.1
  • 24
    • 0032693022 scopus 로고    scopus 로고
    • The distribution of oedema in the lower limb of patients with chronic critical limb ischaemia: A study with computed tomography
    • Khiabani, HZ, MD Anvar, B Rostad, et al: The distribution of oedema in the lower limb of patients with chronic critical limb ischaemia: A study with computed tomography. Vasa 28 (1999), 265-270.
    • (1999) Vasa , vol.28 , pp. 265-270
    • Khiabani, H.Z.1    Anvar, M.D.2    Rostad, B.3
  • 25
    • 0026948686 scopus 로고
    • Subcutaneous interstitial fluid pressure and arm volume in lymphoedema
    • Bates, DO, JR Levick, PS Mortimer: Subcutaneous interstitial fluid pressure and arm volume in lymphoedema. Int. J. Microcirc. Clin. Exp. 11 (1992), 359-373.
    • (1992) Int. J. Microcirc. Clin. Exp , vol.11 , pp. 359-373
    • Bates, D.O.1    Levick, J.R.2    Mortimer, P.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.