메뉴 건너뛰기




Volumn 14, Issue 4, 2010, Pages

Withdrawing intra-aortic balloon pump support paradoxically improves microvascular flow

Author keywords

[No Author keywords available]

Indexed keywords

AGED; AORTA BALLOON; ARTICLE; BALLOON CATHETER; BLOOD FLOW; CARDIOGENIC SHOCK; CATHETER REMOVAL; CLINICAL ARTICLE; CLINICAL DECISION MAKING; DIASTOLIC BLOOD PRESSURE; FEMALE; HEMODYNAMIC PARAMETERS; HEMODYNAMICS; HUMAN; INTENSIVE CARE UNIT; MALE; MEAN ARTERIAL PRESSURE; MICROCIRCULATION; MICROVASCULAR FLOW INDEX; OXIMETRY; OXYGENATION; PERFUSED VESSEL DENSITY; PRIORITY JOURNAL; VIDEORECORDING; BLOOD; BLOOD FLOW VELOCITY; BLOOD PRESSURE; MICROVASCULATURE; PATHOPHYSIOLOGY; PHYSIOLOGY;

EID: 77955811514     PISSN: 13648535     EISSN: 1466609X     Source Type: Journal    
DOI: 10.1186/cc9242     Document Type: Article
Times cited : (40)

References (32)
  • 1
    • 33646061032 scopus 로고    scopus 로고
    • Intra-aortic balloon counterpulsation
    • 10.1016/j.amjcard.2005.11.070, 16635618
    • Trost JC, Hillis LD. Intra-aortic balloon counterpulsation. Am J Cardiol 2006, 97:1391-1398. 10.1016/j.amjcard.2005.11.070, 16635618.
    • (2006) Am J Cardiol , vol.97 , pp. 1391-1398
    • Trost, J.C.1    Hillis, L.D.2
  • 2
    • 30344471501 scopus 로고    scopus 로고
    • Aortic counterpulsation: a review of the hemodynamic effects and indications for use
    • 10.1002/ccd.20552, 16342217
    • Santa-Cruz RA, Cohen MG, Ohman EM. Aortic counterpulsation: a review of the hemodynamic effects and indications for use. Catheter Cardiovasc Interv 2006, 67:68-77. 10.1002/ccd.20552, 16342217.
    • (2006) Catheter Cardiovasc Interv , vol.67 , pp. 68-77
    • Santa-Cruz, R.A.1    Cohen, M.G.2    Ohman, E.M.3
  • 3
    • 0028222727 scopus 로고
    • Counterpulsation: historical background, technical improvements, hemodynamic and metabolic effects
    • 10.1159/000176394, 8205565
    • Nanas JN, Moulopoulos SD. Counterpulsation: historical background, technical improvements, hemodynamic and metabolic effects. Cardiology 1994, 84:156-167. 10.1159/000176394, 8205565.
    • (1994) Cardiology , vol.84 , pp. 156-167
    • Nanas, J.N.1    Moulopoulos, S.D.2
  • 4
    • 34249083324 scopus 로고    scopus 로고
    • Mechanisms of critical illness--classifying microcirculatory flow abnormalities in distributive shock
    • 10.1186/cc4969, 1750971, 16879732
    • Elbers PW, Ince C. Mechanisms of critical illness--classifying microcirculatory flow abnormalities in distributive shock. Crit Care 2006, 10:221. 10.1186/cc4969, 1750971, 16879732.
    • (2006) Crit Care , vol.10 , pp. 221
    • Elbers, P.W.1    Ince, C.2
  • 5
    • 0034967945 scopus 로고    scopus 로고
    • Comparison of OPS imaging and conventional capillary microscopy to study the human microcirculation
    • Mathura KR, Vollebregt KC, Boer K, De Graaff JC, Ubbink DT, Ince C. Comparison of OPS imaging and conventional capillary microscopy to study the human microcirculation. J Appl Physiol 2001, 91:74-78.
    • (2001) J Appl Physiol , vol.91 , pp. 74-78
    • Mathura, K.R.1    Vollebregt, K.C.2    Boer, K.3    De Graaff, J.C.4    Ubbink, D.T.5    Ince, C.6
  • 6
    • 0032828956 scopus 로고    scopus 로고
    • Orthogonal polarization spectral imaging: a new method for study of the microcirculation
    • 10.1038/13529, 10502828
    • Groner W, Winkelman JW, Harris AG, Ince C, Bouma GJ, Messmer K, Nadeau RG. Orthogonal polarization spectral imaging: a new method for study of the microcirculation. Nat Med 1999, 5:1209-1212. 10.1038/13529, 10502828.
    • (1999) Nat Med , vol.5 , pp. 1209-1212
    • Groner, W.1    Winkelman, J.W.2    Harris, A.G.3    Ince, C.4    Bouma, G.J.5    Messmer, K.6    Nadeau, R.G.7
  • 7
    • 36248992450 scopus 로고    scopus 로고
    • Sidestream Dark Field (SDF) imaging: a novel stroboscopic LED ring-based imaging modality for clinical assessment of the microcirculation
    • 10.1364/OE.15.015101, 19550794
    • Goedhart PT, Khalilzada M, Bezemer R, Merza J, Ince C. Sidestream Dark Field (SDF) imaging: a novel stroboscopic LED ring-based imaging modality for clinical assessment of the microcirculation. Opt Express 2007, 15:15101-15114. 10.1364/OE.15.015101, 19550794.
    • (2007) Opt Express , vol.15 , pp. 15101-15114
    • Goedhart, P.T.1    Khalilzada, M.2    Bezemer, R.3    Merza, J.4    Ince, C.5
  • 8
    • 0347416931 scopus 로고    scopus 로고
    • Microvascular alterations in patients with acute severe heart failure and cardiogenic shock
    • 10.1016/j.ahj.2003.07.006, 14691425
    • De Backer D, Creteur J, Dubois MJ, Sakr Y, Vincent JL. Microvascular alterations in patients with acute severe heart failure and cardiogenic shock. Am Heart J 2004, 147:91-99. 10.1016/j.ahj.2003.07.006, 14691425.
    • (2004) Am Heart J , vol.147 , pp. 91-99
    • De Backer, D.1    Creteur, J.2    Dubois, M.J.3    Sakr, Y.4    Vincent, J.L.5
  • 10
    • 58149507790 scopus 로고    scopus 로고
    • Microcirculatory imaging in cardiac anesthesia: ketanserin reduces blood pressure but not perfused capillary density
    • 10.1053/j.jvca.2008.09.013, 19058975
    • Elbers PW, Ozdemir A, van Iterson M, van Dongen EP, Ince C. Microcirculatory imaging in cardiac anesthesia: ketanserin reduces blood pressure but not perfused capillary density. J Cardiothorac Vasc Anesth 2009, 23:95-101. 10.1053/j.jvca.2008.09.013, 19058975.
    • (2009) J Cardiothorac Vasc Anesth , vol.23 , pp. 95-101
    • Elbers, P.W.1    Ozdemir, A.2    van Iterson, M.3    van Dongen, E.P.4    Ince, C.5
  • 11
    • 31344453457 scopus 로고    scopus 로고
    • The effects of dobutamine on microcirculatory alterations in patients with septic shock are independent of its systemic effects
    • 10.1097/01.CCM.0000198107.61493.5A, 16424721
    • De Backer D, Creteur J, Dubois MJ, Sakr Y, Koch M, Verdant C, Vincent JL. The effects of dobutamine on microcirculatory alterations in patients with septic shock are independent of its systemic effects. Crit Care Med 2006, 34:403-408. 10.1097/01.CCM.0000198107.61493.5A, 16424721.
    • (2006) Crit Care Med , vol.34 , pp. 403-408
    • De Backer, D.1    Creteur, J.2    Dubois, M.J.3    Sakr, Y.4    Koch, M.5    Verdant, C.6    Vincent, J.L.7
  • 12
    • 0032790876 scopus 로고    scopus 로고
    • Microcirculatory oxygenation and shunting in sepsis and shock
    • 10.1097/00003246-199907000-00031, 10446833
    • Ince C, Sinaasappel M. Microcirculatory oxygenation and shunting in sepsis and shock. Crit Care Med 1999, 27:1369-1377. 10.1097/00003246-199907000-00031, 10446833.
    • (1999) Crit Care Med , vol.27 , pp. 1369-1377
    • Ince, C.1    Sinaasappel, M.2
  • 13
    • 54049138483 scopus 로고    scopus 로고
    • The heterogeneity of the microcirculation in critical illness
    • 10.1016/j.ccm.2008.06.008, 18954699
    • Klijn E, den Uil CA, Bakker J, Ince C. The heterogeneity of the microcirculation in critical illness. Clin Chest Med 2008, 29:643-654. 10.1016/j.ccm.2008.06.008, 18954699.
    • (2008) Clin Chest Med , vol.29 , pp. 643-654
    • Klijn, E.1    den Uil, C.A.2    Bakker, J.3    Ince, C.4
  • 15
    • 68649127311 scopus 로고    scopus 로고
    • Acute microflow changes after stop and restart of intra-aortic balloon pump in cardiogenic shock
    • 10.1007/s00392-009-0018-0, 19367424
    • Jung C, Rödiger C, Fritzenwanger M, Schumm J, Lauten A, Figulla HR, Ferrari M. Acute microflow changes after stop and restart of intra-aortic balloon pump in cardiogenic shock. Clin Res Cardiol 2009, 98:469-475. 10.1007/s00392-009-0018-0, 19367424.
    • (2009) Clin Res Cardiol , vol.98 , pp. 469-475
    • Jung, C.1    Rödiger, C.2    Fritzenwanger, M.3    Schumm, J.4    Lauten, A.5    Figulla, H.R.6    Ferrari, M.7
  • 16
    • 64149110786 scopus 로고    scopus 로고
    • The effects of intra-aortic balloon pump support on macrocirculation and tissue microcirculation in patients with cardiogenic shock
    • 10.1159/000212060, 19365113
    • den Uil CA, Lagrand WK, van der Ent M, Jewbali LS, Brugts JJ, Spronk PE, Simoons ML. The effects of intra-aortic balloon pump support on macrocirculation and tissue microcirculation in patients with cardiogenic shock. Cardiology 2009, 114:42-46. 10.1159/000212060, 19365113.
    • (2009) Cardiology , vol.114 , pp. 42-46
    • den Uil, C.A.1    Lagrand, W.K.2    van der Ent, M.3    Jewbali, L.S.4    Brugts, J.J.5    Spronk, P.E.6    Simoons, M.L.7
  • 17
    • 76149143412 scopus 로고    scopus 로고
    • Effect of intra-aortic balloon pump support on microcirculation during high-risk percutaneous intervention
    • 10.1177/0267659109358208, 20093337
    • Jung C, Lauten A, Rödiger C, Krizanic F, Figulla HR, Ferrari M. Effect of intra-aortic balloon pump support on microcirculation during high-risk percutaneous intervention. Perfusion 2009, 24:417-421. 10.1177/0267659109358208, 20093337.
    • (2009) Perfusion , vol.24 , pp. 417-421
    • Jung, C.1    Lauten, A.2    Rödiger, C.3    Krizanic, F.4    Figulla, H.R.5    Ferrari, M.6
  • 19
    • 78651245550 scopus 로고    scopus 로고
    • WinDV, a small Windows utility for DV (FireWire digital video) input/output
    • WinDV, a small Windows utility for DV (FireWire digital video) input/output. , http://windv.mourek.cz/
  • 20
    • 33845872563 scopus 로고    scopus 로고
    • Microcirculatory Alterations in Resuscitation and Shock Investigators. Early microcirculatory perfusion derangements in patients with severe sepsis and septic shock: relationship to hemodynamics, oxygen transport, and survival
    • 10.1016/j.annemergmed.2006.08.021, 17095120
    • Trzeciak S, Dellinger RP, Parrillo JE, Guglielmi M, Bajaj J, Abate NL, Arnold RC, Colilla S, Zanotti S, Hollenberg SM. Microcirculatory Alterations in Resuscitation and Shock Investigators. Early microcirculatory perfusion derangements in patients with severe sepsis and septic shock: relationship to hemodynamics, oxygen transport, and survival. Ann Emerg Med 2007, 49:88-98. 10.1016/j.annemergmed.2006.08.021, 17095120.
    • (2007) Ann Emerg Med , vol.49 , pp. 88-98
    • Trzeciak, S.1    Dellinger, R.P.2    Parrillo, J.E.3    Guglielmi, M.4    Bajaj, J.5    Abate, N.L.6    Arnold, R.C.7    Colilla, S.8    Zanotti, S.9    Hollenberg, S.M.10
  • 22
    • 33645548973 scopus 로고    scopus 로고
    • Quantifying bedside-derived imaging of microcirculatory abnormalities in septic patients: a prospective validation study
    • 10.1186/cc3809, 1414044, 16280059
    • Boerma EC, Mathura KR, van der Voort PH, Spronk PE, Ince C. Quantifying bedside-derived imaging of microcirculatory abnormalities in septic patients: a prospective validation study. Crit Care 2005, 9:R601-606. 10.1186/cc3809, 1414044, 16280059.
    • (2005) Crit Care , vol.9
    • Boerma, E.C.1    Mathura, K.R.2    van der Voort, P.H.3    Spronk, P.E.4    Ince, C.5
  • 23
    • 38349088317 scopus 로고    scopus 로고
    • Fast-track microcirculation analysis
    • 10.1186/cc6182, 2246214, 18226178
    • Elbers PW. Fast-track microcirculation analysis. Crit Care 2007, 11:426. 10.1186/cc6182, 2246214, 18226178.
    • (2007) Crit Care , vol.11 , pp. 426
    • Elbers, P.W.1
  • 24
    • 0025272491 scopus 로고
    • Pressure-flow relations in coronary circulation
    • Hoffman JI, Spaan JA. Pressure-flow relations in coronary circulation. Physiol Rev 1990, 70:331-390.
    • (1990) Physiol Rev , vol.70 , pp. 331-390
    • Hoffman, J.I.1    Spaan, J.A.2
  • 25
    • 0025293530 scopus 로고
    • Starling resistor versus compliance. Which explains the zero-flow pressure of a dynamic arterial pressure-flow relation?
    • Magder S. Starling resistor versus compliance. Which explains the zero-flow pressure of a dynamic arterial pressure-flow relation?. Circ Res 1990, 67:209-220.
    • (1990) Circ Res , vol.67 , pp. 209-220
    • Magder, S.1
  • 26
    • 18844400110 scopus 로고    scopus 로고
    • Influence of intra-aortic balloon pumping on cerebral blood flow pattern in patients after cardiac surgery
    • Schachtrupp A, Wrigge H, Busch T, Buhre W, Weyland A. Influence of intra-aortic balloon pumping on cerebral blood flow pattern in patients after cardiac surgery. Eur J Anaesthesiol 2005, 22:165-170.
    • (2005) Eur J Anaesthesiol , vol.22 , pp. 165-170
    • Schachtrupp, A.1    Wrigge, H.2    Busch, T.3    Buhre, W.4    Weyland, A.5
  • 27
    • 0025342060 scopus 로고
    • Reversed intracranial blood flow in patients with an intra-aortic balloon pump
    • Brass LM. Reversed intracranial blood flow in patients with an intra-aortic balloon pump. Stroke 1990, 21:484-487.
    • (1990) Stroke , vol.21 , pp. 484-487
    • Brass, L.M.1
  • 28
    • 34247171377 scopus 로고    scopus 로고
    • Relationship between sublingual and intestinal microcirculatory perfusion in patients with abdominal sepsis
    • 10.1097/01.CCM.0000259527.89927.F9, 17334238
    • Boerma EC, van der Voort PH, Spronk PE, Ince C. Relationship between sublingual and intestinal microcirculatory perfusion in patients with abdominal sepsis. Crit Care Med 2007, 35:1055-1060. 10.1097/01.CCM.0000259527.89927.F9, 17334238.
    • (2007) Crit Care Med , vol.35 , pp. 1055-1060
    • Boerma, E.C.1    van der Voort, P.H.2    Spronk, P.E.3    Ince, C.4
  • 29
    • 73449092811 scopus 로고    scopus 로고
    • Evaluation of sublingual and gut mucosal microcirculation in sepsis: a quantitative analysis
    • 10.1097/CCM.0b013e3181b029c1, 19770750
    • Verdant CL, De Backer D, Bruhn A, Clausi CM, Su F, Wang Z, Rodriguez H, Pries AR, Vincent JL. Evaluation of sublingual and gut mucosal microcirculation in sepsis: a quantitative analysis. Crit Care Med 2009, 37:2875-2881. 10.1097/CCM.0b013e3181b029c1, 19770750.
    • (2009) Crit Care Med , vol.37 , pp. 2875-2881
    • Verdant, C.L.1    De Backer, D.2    Bruhn, A.3    Clausi, C.M.4    Su, F.5    Wang, Z.6    Rodriguez, H.7    Pries, A.R.8    Vincent, J.L.9
  • 30
    • 77249122088 scopus 로고    scopus 로고
    • The cerebral microcirculation is protected during experimental hemorrhagic shock
    • 10.1097/CCM.0b013e3181cd100c, 20068466
    • Wan Z, Sun S, Ristagno G, Weil MH, Tang W. The cerebral microcirculation is protected during experimental hemorrhagic shock. Crit Care Med 2010, 38:928-932. 10.1097/CCM.0b013e3181cd100c, 20068466.
    • (2010) Crit Care Med , vol.38 , pp. 928-932
    • Wan, Z.1    Sun, S.2    Ristagno, G.3    Weil, M.H.4    Tang, W.5
  • 31
    • 74049156928 scopus 로고    scopus 로고
    • Intra-aortic balloon counterpulsation in patients with acute myocardial infarction complicated by cardiogenic shock: the prospective, randomized IABP SHOCK Trial for attenuation of multiorgan dysfunction syndrome
    • 10.1097/CCM.0b013e3181b78671, 19770739
    • Prondzinsky R, Lemm H, Swyter M, Wegener N, Unverzagt S, Carter JM, Russ M, Schlitt A, Buerke U, Christoph A, Schmidt H, Winkler M, Thiery J, Werdan K, Buerke M. Intra-aortic balloon counterpulsation in patients with acute myocardial infarction complicated by cardiogenic shock: the prospective, randomized IABP SHOCK Trial for attenuation of multiorgan dysfunction syndrome. Crit Care Med 2010, 38:152-160. 10.1097/CCM.0b013e3181b78671, 19770739.
    • (2010) Crit Care Med , vol.38 , pp. 152-160
    • Prondzinsky, R.1    Lemm, H.2    Swyter, M.3    Wegener, N.4    Unverzagt, S.5    Carter, J.M.6    Russ, M.7    Schlitt, A.8    Buerke, U.9    Christoph, A.10    Schmidt, H.11    Winkler, M.12    Thiery, J.13    Werdan, K.14    Buerke, M.15
  • 32
    • 62749144520 scopus 로고    scopus 로고
    • A systematic review and meta-analysis of intra-aortic balloon pump therapy in ST-elevation myocardial infarction: should we change the guidelines?
    • 10.1093/eurheartj/ehn602, 19168529
    • Sjauw KD, Engstrom AE, Vis MM, van der Schaaf RJ, Baan J, Koch KT, de Winter RJ, Piek JJ, Tijssen JG, Henriques JP. A systematic review and meta-analysis of intra-aortic balloon pump therapy in ST-elevation myocardial infarction: should we change the guidelines?. Eur Heart J 2009, 30:459-468. 10.1093/eurheartj/ehn602, 19168529.
    • (2009) Eur Heart J , vol.30 , pp. 459-468
    • Sjauw, K.D.1    Engstrom, A.E.2    Vis, M.M.3    van der Schaaf, R.J.4    Baan, J.5    Koch, K.T.6    de Winter, R.J.7    Piek, J.J.8    Tijssen, J.G.9    Henriques, J.P.10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.