메뉴 건너뛰기




Volumn 59, Issue 9, 2010, Pages 2391-2404

Instruments and methods for calibration of oscillometric blood pressure measurement devices

Author keywords

Blood pressure (BP); calibration; noninvasive measurement; oscillometric method; simulators; standardization

Indexed keywords

ARTERIAL BLOOD PRESSURE; CALIBRATION PROCEDURE; HIGH COSTS; NONINVASIVE MEASUREMENTS; OBJECTIVE MEASUREMENT; OSCILLOMETRIC METHOD; TIME-CONSUMING PROCESS;

EID: 77955713153     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2010.2050978     Document Type: Article
Times cited : (45)

References (62)
  • 1
    • 33748579939 scopus 로고    scopus 로고
    • Accuracy of blood pressure measurement: Sphygmomanometer calibration and beyond
    • Oct.
    • G. Paratia, A. Fainia, and P. Castiglioni, "Accuracy of blood pressure measurement: Sphygmomanometer calibration and beyond," J. Hypertens., vol.24, no.10, pp. 1915-1918, Oct. 2006.
    • (2006) J. Hypertens. , vol.24 , Issue.10 , pp. 1915-1918
    • Paratia, G.1    Fainia, A.2    Castiglioni, P.3
  • 2
    • 38449090401 scopus 로고    scopus 로고
    • Sphygmomanometer calibration-Why, how and how often?
    • Oct.
    • M. J. Turner, C. Speechly, and N. Bignell, "Sphygmomanometer calibration-Why, how and how often?" Aust. Fam. Physician, vol.36, no.10, pp. 834-837, Oct. 2007.
    • (2007) Aust. Fam. Physician , vol.36 , Issue.10 , pp. 834-837
    • Turner, M.J.1    Speechly, C.2    Bignell, N.3
  • 3
    • 77955717522 scopus 로고    scopus 로고
    • IEEE Standard for Objective Measurement of Systemic Arterial Blood Pressure in Humans, IEEE P1721
    • IEEE Standard for Objective Measurement of Systemic Arterial Blood Pressure in Humans, IEEE P1721.
  • 4
    • 67650119710 scopus 로고    scopus 로고
    • Standard calibration procedures for automated non-invasive measurement of blood pressure
    • Jun.
    • E. Balestrieri and S. Rapuano, "Standard calibration procedures for automated non-invasive measurement of blood pressure," Int. J. Adv. Media Commun., vol.3, no.1, pp. 226-246, Jun. 2009.
    • (2009) Int. J. Adv. Media Commun. , vol.3 , Issue.1 , pp. 226-246
    • Balestrieri, E.1    Rapuano, S.2
  • 5
    • 70449659659 scopus 로고    scopus 로고
    • Open questions on unified approach for calibration of oscillometric blood pressure measurement devices
    • Cetraro, Italy, May 29-30
    • E. Balestrieri, P. Daponte, and S. Rapuano, "Open questions on unified approach for calibration of oscillometric blood pressure measurement devices," in Proc. MeMeA-Int. Workshop Med. Meas. Appl. Cetraro, Italy, May 29-30, 2009, pp. 206-211.
    • (2009) Proc. MeMeA-Int. Workshop Med. Meas. Appl. , pp. 206-211
    • Balestrieri, E.1    Daponte, P.2    Rapuano, S.3
  • 9
    • 1542330671 scopus 로고    scopus 로고
    • An experience in implementing the oscillometric algorithm for the noninvasive determination of human blood pressure
    • Cancun, Mexico, Sep. 17-21
    • A. Ball-llovera, R. Del Rey, R. Ruso, J. Ramos, O. Batista, and I. Niubo, "An experience in implementing the oscillometric algorithm for the noninvasive determination of human blood pressure," in Proc. 25th Annu. Int. Conf. IEEE EMBS, Cancun, Mexico, Sep. 17-21, 2003, pp. 3173-3175.
    • (2003) Proc. 25th Annu. Int. Conf. IEEE EMBS , pp. 3173-3175
    • Ball-Llovera, A.1    Del Rey, R.2    Ruso, R.3    Ramos, J.4    Batista, O.5    Niubo, I.6
  • 10
    • 1542344282 scopus 로고
    • Standard algorithm of blood-pressure measurement by the oscillometric method
    • Letters to the Editor,Nov.
    • A. Sapinski, "Standard algorithm of blood-pressure measurement by the oscillometric method," Med. Biol. Eng. Comput., vol.30, no.6, p. 671, Nov. 1992, Letters to the Editor.
    • (1992) Med. Biol. Eng. Comput. , vol.30 , Issue.6 , pp. 671
    • Sapinski, A.1
  • 11
    • 1542373962 scopus 로고
    • Blood pressure: Differential auscultatoly technique
    • Apr.
    • W. Kaspari, "Blood pressure: Differential auscultatoly technique," Med. Electron., Apr. 1995.
    • (1995) Med. Electron.
    • Kaspari, W.1
  • 12
    • 1542284011 scopus 로고
    • Standard algorithm of blood-pressure measurement by the oscillometric method
    • Mar., Letters to the Editor
    • K. Yamakoshi and S. Tanka, "Standard algorithm of blood-pressure measurement by the oscillometric method," Med. Biol. Eng. Comput., vol.31, no.2, p. 204, Mar. 1993, Letters to the Editor.
    • (1993) Med. Biol. Eng. Comput. , vol.31 , Issue.2 , pp. 204
    • Yamakoshi, K.1    Tanka, S.2
  • 14
    • 41049090878 scopus 로고    scopus 로고
    • Accuracy comparison of oscillometric and electronic palpation blood pressure measuring methods using intra-arterial method as a reference
    • H. Sorvoja, R. Myllylä, P. Kärjä-Koskenkari, J. Koskenkari, M. Lilja, and Y. A. Kesäniemi, "Accuracy comparison of oscillometric and electronic palpation blood pressure measuring methods using intra-arterial method as a reference," Molecular Quantum Acoust., vol.26, pp. 235-260, 2005.
    • (2005) Molecular Quantum Acoust. , vol.26 , pp. 235-260
    • Sorvoja, H.1    Myllylä, R.2    Kärjä-Koskenkari, P.3    Koskenkari, J.4    Lilja, M.5    Kesäniemi, Y.A.6
  • 16
    • 0000662951 scopus 로고
    • Noninvasive assessment of arterial blood pressure and mechanics
    • Boca Raton, FL: CRC Press
    • G. Drziewiecki, "Noninvasive assessment of arterial blood pressure and mechanics," in The Biomedical Engineering Handbook. Boca Raton, FL: CRC Press, 1995, pp. 1196-1211.
    • (1995) The Biomedical Engineering Handbook , pp. 1196-1211
    • Drziewiecki, G.1
  • 17
    • 70449652480 scopus 로고    scopus 로고
    • Theoretical basis for proposed standard algorithm of blood pressure measurement by the sphygmooscillographic method
    • May
    • A. Sapinski, "Theoretical basis for proposed standard algorithm of blood pressure measurement by the sphygmooscillographic method," J. Clin. Eng., vol.22, no.3, pp. 171-174, May 1997.
    • (1997) J. Clin. Eng. , vol.22 , Issue.3 , pp. 171-174
    • Sapinski, A.1
  • 18
    • 0035527552 scopus 로고    scopus 로고
    • Oscillometric blood pressure measurement: Progress and problems
    • Dec.
    • G. A. van Montfrans, "Oscillometric blood pressure measurement: Progress and problems," Blood Press. Monit., vol.6, no.6, pp. 287-290, Dec. 2001.
    • (2001) Blood Press. Monit. , vol.6 , Issue.6 , pp. 287-290
    • Van Montfrans, G.A.1
  • 19
    • 0030877937 scopus 로고    scopus 로고
    • Development and validation of a noninvasive method to determine arterial pressure and vascular compliance
    • Aug.
    • T. J. Brinton, B. Cotter, M. T. Kailasam, D. L. Brown, S. S. Chio, D. T. O'Connor, and A. N. DeMaria, "Development and validation of a noninvasive method to determine arterial pressure and vascular compliance," Amer. J. Cardiol., vol.80, no.3, pp. 323-330, Aug. 1997.
    • (1997) Amer. J. Cardiol. , vol.80 , Issue.3 , pp. 323-330
    • Brinton, T.J.1    Cotter, B.2    Kailasam, M.T.3    Brown, D.L.4    Chio, S.S.5    O'Connor, D.T.6    Demaria, A.N.7
  • 20
    • 0029079812 scopus 로고
    • Noninvasive blood pressure monitoring from the supraorbital artery using an artificial neural network oscillometric algorithm
    • Sep.
    • S. Narus, T. Egbert, T. K. Lee, J. Lu, and D. Westenskow, "Noninvasive blood pressure monitoring from the supraorbital artery using an artificial neural network oscillometric algorithm," J. Clin. Monit., vol.11, no.5, pp. 289-297, Sep. 1995.
    • (1995) J. Clin. Monit. , vol.11 , Issue.5 , pp. 289-297
    • Narus, S.1    Egbert, T.2    Lee, T.K.3    Lu, J.4    Westenskow, D.5
  • 21
    • 0035987980 scopus 로고    scopus 로고
    • Principles and techniques of blood pressure measurement
    • May
    • T. G. Pickering, "Principles and techniques of blood pressure measurement," Cardiol. Clin., vol.20, no.2, pp. 207-223, May 2002.
    • (2002) Cardiol. Clin. , vol.20 , Issue.2 , pp. 207-223
    • Pickering, T.G.1
  • 23
    • 47949094834 scopus 로고    scopus 로고
    • Bench testing of oscillometric blood pressure monitors
    • J. Jilek and M. Stork, "Bench testing of oscillometric blood pressure monitors," in Proc. Appl. Electron., 2006, pp. 67-70.
    • (2006) Proc. Appl. Electron. , pp. 67-70
    • Jilek, J.1    Stork, M.2
  • 24
    • 20044372008 scopus 로고    scopus 로고
    • Low-cost oscillometric non-invasive blood pressure monitors: Device repeatability and device differences
    • DOI 10.1088/0967-3334/26/4/010
    • A. J. Sims, C. A. Reay, D. R. Bousfield, J. A. Menes, and A. Murray, "Low-cost oscillometric non-invasive blood pressure monitors: Device repeatability and device differences," Physiol. Meas., vol.26, no.4, pp. 441-445, Aug. 2005. (Pubitemid 40768142)
    • (2005) Physiological Measurement , vol.26 , Issue.4 , pp. 441-445
    • Sims, A.J.1    Reay, C.A.2    Bousfield, D.R.3    Menes, J.A.4    Murray, A.5
  • 26
    • 0037387587 scopus 로고    scopus 로고
    • Reduction of interference in oscillometric arterial blood pressure measurement using fuzzy logic
    • Apr.
    • C. T. Lin, S. H. Liu, J. J.Wang, and Z. C.Wen, "Reduction of interference in oscillometric arterial blood pressure measurement using fuzzy logic," IEEE Trans. Biomed. Eng., vol.50, no.4, pp. 432-441, Apr. 2003.
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , Issue.4 , pp. 432-441
    • Lin, C.T.1    Liu, S.H.2    Wang, J.J.3    Wen, Z.C.4
  • 27
    • 62249162195 scopus 로고    scopus 로고
    • Estimation of mean blood pressure from oscillometric and manual methods
    • D. Zheng and A. Murray, "Estimation of mean blood pressure from oscillometric and manual methods," in Proc. Comput. Cardiol., 2008, vol.35, pp. 941-944.
    • (2008) Proc. Comput. Cardiol. , vol.35 , pp. 941-944
    • Zheng, D.1    Murray, A.2
  • 28
    • 61849100376 scopus 로고    scopus 로고
    • A new noise reduction method for oscillometric blood pressure measurement
    • Vancouver, BC, Canada, Aug.20-24
    • H. S. Choi, H. S. Myoung, H. K. Lee, H. D. Park, and K. J. Lee, "A new noise reduction method for oscillometric blood pressure measurement," in Proc. 30th Annu. Int. IEEE EMBS Conf., Vancouver, BC, Canada, Aug. 20-24, 2008, pp. 270-272.
    • (2008) Proc. 30th Annu. Int. IEEE EMBS Conf. , pp. 270-272
    • Choi, H.S.1    Myoung, H.S.2    Lee, H.K.3    Park, H.D.4    Lee, K.J.5
  • 29
    • 70350632655 scopus 로고    scopus 로고
    • Influence of different representations of the oscillometric index on automatic determination of the systolic and diastolic blood pressures
    • V. Jazbinsek, J. Luznik, and Z. Trontelj, "Influence of different representations of the oscillometric index on automatic determination of the systolic and diastolic blood pressures," in Proc. IFMBE, 2008, pp. 216-220.
    • (2008) Proc. IFMBE , pp. 216-220
    • Jazbinsek, V.1    Luznik, J.2    Trontelj, Z.3
  • 30
    • 57849128912 scopus 로고    scopus 로고
    • Oscillometric blood pressure measurements: Differences between measured and calculated mean arterial pressure
    • Dec.
    • H. D. Kiers, J. M. Hofstra, and J. F.M.Wetzels, "Oscillometric blood pressure measurements: Differences between measured and calculated mean arterial pressure," Neth. J. Med., vol.66, no.11, pp. 474-479, Dec. 2008.
    • (2008) Neth. J. Med. , vol.66 , Issue.11 , pp. 474-479
    • Kiers, H.D.1    Hofstra, J.M.2    Wetzels, J.F.M.3
  • 31
    • 57649180632 scopus 로고    scopus 로고
    • Comparative study of non-invasive blood pressure measurement methods in elderly people
    • Lyon, France, Aug. 23-26
    • V. Fabián, M. Janouch, L. Nováková, and O. Štepánková, "Comparative study of non-invasive blood pressure measurement methods in elderly people," in Proc. IEEE EMBS Cité Internationale, Lyon, France, Aug. 23-26, 2007, pp. 612-615.
    • (2007) Proc. IEEE EMBS Cité Internationale , pp. 612-615
    • Fabián, V.1    Janouch, M.2    Nováková, L.3    Štepánková, O.4
  • 32
    • 77955711801 scopus 로고    scopus 로고
    • Minimization of artifact using adaptive digital filter during the oscillometric blood pressure measurement
    • Oct. 17-20
    • H. D. Park, H. S. Choi, S. P. Cho, and K. J. Lee, "Minimization of artifact using adaptive digital filter during the oscillometric blood pressure measurement," in Proc. Int. Conf. Control, Autom. Syst., Seoul, Korea, Oct. 17-20, 2007, pp. 612-615.
    • (2007) Proc. Int. Conf. Control, Autom. Syst., Seoul, Korea , pp. 612-615
    • Park, H.D.1    Choi, H.S.2    Cho, S.P.3    Lee, K.J.4
  • 33
    • 52649130892 scopus 로고    scopus 로고
    • Assessment of the validation of blood pressure monitors: A statistical reappraisal
    • Aug.
    • B. A. Friedman, "Assessment of the validation of blood pressure monitors: A statistical reappraisal," Blood Press. Monit., vol.13, no.4, pp. 187-191, Aug. 2008.
    • (2008) Blood Press. Monit. , vol.13 , Issue.4 , pp. 187-191
    • Friedman, B.A.1
  • 35
    • 77955715408 scopus 로고    scopus 로고
    • APEC/APLMF Training Courses in Legal Metrology
    • APEC/APLMF Training Courses in Legal Metrology, Handbook on Automated Sphygmomanometers, 2006.
    • (2006) Handbook on Automated Sphygmomanometers
  • 37
    • 33744508715 scopus 로고    scopus 로고
    • Can a simulator that regenerates physiological waveforms evaluate oscillometric non-invasive blood pressure devices?
    • Apr.
    • J. N. Amoore, E. Vacher, I. C. Murray, S. Mieke, S. T. King, F. E. Smith, and A. Murray, "Can a simulator that regenerates physiological waveforms evaluate oscillometric non-invasive blood pressure devices?" Blood Press. Monit., vol.11, no.2, pp. 63-67, Apr. 2006.
    • (2006) Blood Press. Monit. , vol.11 , Issue.2 , pp. 63-67
    • Amoore, J.N.1    Vacher, E.2    Murray, I.C.3    Mieke, S.4    King, S.T.5    Smith, F.E.6    Murray, A.7
  • 38
    • 77955718004 scopus 로고    scopus 로고
    • JCGM 200:2008, "international vocabulary of metrology-basic and general concepts and associated terms," 3rd ed., VIM, 2008
    • JCGM 200:2008, "international vocabulary of metrology-basic and general concepts and associated terms," 3rd ed., VIM, 2008.
  • 40
    • 77955710450 scopus 로고    scopus 로고
    • CAS Medical Systems Inc., "performance of the CAS oscillometric algorithm when compared against various commercially available NIBP simulators," Branford, CT, White paper, Oct. 2007
    • CAS Medical Systems Inc., "performance of the CAS oscillometric algorithm when compared against various commercially available NIBP simulators," Branford, CT, White paper, Oct. 2007.
  • 41
    • 85007106991 scopus 로고    scopus 로고
    • Evaluation of non-invasive blood pressure simulators
    • Ljubljana, Slovenia, Jun.
    • G. Gersak and J. Drnovsek, "Evaluation of non-invasive blood pressure simulators," in Proc. Mediterranean Conf. Med. Biomed. Eng. Comput., Ljubljana, Slovenia, Jun. 2007, pp. 342-345.
    • (2007) Proc. Mediterranean Conf. Med. Biomed. Eng. Comput. , pp. 342-345
    • Gersak, G.1    Drnovsek, J.2
  • 42
    • 77249125284 scopus 로고    scopus 로고
    • A procedure for evaluation of non-invasive blood pressure simulators
    • Dec.
    • G. Gersak, A. Zemva, and J. Drnovsek, "A procedure for evaluation of non-invasive blood pressure simulators," Med. Biol. Eng. Comput., vol.47, no.12, pp. 1221-1228, Dec. 2009.
    • (2009) Med. Biol. Eng. Comput. , vol.47 , Issue.12 , pp. 1221-1228
    • Gersak, G.1    Zemva, A.2    Drnovsek, J.3
  • 43
    • 70449643187 scopus 로고
    • Design overview of a microcomputer-controlled NIBP simulator for evaluation of non-invasive blood pressure monitors
    • Durham, NC, Oct.
    • K. Ng and C. F. Small, "Design overview of a microcomputer- controlled NIBP simulator for evaluation of non-invasive blood pressure monitors," in Proc. Comput. Cardiol., Durham, NC, Oct. 1992, pp. 551-554.
    • (1992) Proc. Comput. Cardiol. , pp. 551-554
    • Ng, K.1    Small, C.F.2
  • 44
    • 14944340534 scopus 로고    scopus 로고
    • Evaluation of the A&D UA-767 and Welch Allyn Spot Vital Signs noninvasive blood pressure monitors using a blood pressure simulator
    • Mar.
    • P. D. Davis, J. L. Dennis, and R. Railton, "Evaluation of the A&D UA-767 and Welch Allyn Spot Vital Signs noninvasive blood pressure monitors using a blood pressure simulator," J. Hum. Hypertens., vol.19, no.3, pp. 197-203, Mar. 2005.
    • (2005) J. Hum. Hypertens. , vol.19 , Issue.3 , pp. 197-203
    • Davis, P.D.1    Dennis, J.L.2    Railton, R.3
  • 45
    • 0029371648 scopus 로고
    • An automated system for the functional evaluation of oscillometric non-invasive blood pressure monitors
    • Sep.
    • W. B. Geake, J. N. Amoore, and D. H. T. Scott, "An automated system for the functional evaluation of oscillometric non-invasive blood pressure monitors," J. Med. Eng. Technol., vol.19, no.5, pp. 162-176, Sep. 1995.
    • (1995) J. Med. Eng. Technol. , vol.19 , Issue.5 , pp. 162-176
    • Geake, W.B.1    Amoore, J.N.2    Scott, D.H.T.3
  • 46
    • 0030946816 scopus 로고    scopus 로고
    • Evaluation of the Critikon 8100 and Spacelabs 90207 non-invasive blood pressure monitors using a test simulator
    • Mar.
    • J. N. Amoore and W. B. Geake, "Evaluation of the Critikon 8100 and Spacelabs 90207 non-invasive blood pressure monitors using a test simulator," J. Hum. Hypertens., vol.11, no.3, pp. 163-169, Mar. 1997.
    • (1997) J. Hum. Hypertens. , vol.11 , Issue.3 , pp. 163-169
    • Amoore, J.N.1    Geake, W.B.2
  • 47
    • 77955716647 scopus 로고    scopus 로고
    • SunTech Medical Application Note 82-0053-00 Rev., "ANIBP simulator limits with the advantage OEM NIBP module series," Eynsham, U.K., 2000
    • SunTech Medical Application Note 82-0053-00 Rev., "ANIBP simulator limits with the advantage OEM NIBP module series," Eynsham, U.K., 2000.
  • 48
    • 77955709799 scopus 로고    scopus 로고
    • Everett, WA, [Online]. Available.
    • Fluke Biomedical, "CuffLink non-invasive blood pressure simulator," Everett, WA, 2007. [Online]. Available. http://news.fluke.com/ busen/ home/default.htm
    • (2007) CuffLink Non-invasive Blood Pressure Simulator
  • 51
    • 47849110619 scopus 로고    scopus 로고
    • Characterization of blood pressure oscillometric waveforms
    • Cap Esterel, France, Aug.
    • N. Rank, V. Groza, and R. Leca, "Characterization of blood pressure oscillometric waveforms," in Proc. 2nd Int. Conf. Syst. Netw. Commun., Cap Esterel, France, Aug. 2007, pp. 79-82.
    • (2007) Proc. 2nd Int. Conf. Syst. Netw. Commun. , pp. 79-82
    • Rank, N.1    Groza, V.2    Leca, R.3
  • 52
    • 47349125761 scopus 로고    scopus 로고
    • A nonlinear artificial model for generating realistic correlated ECG, BP and respiration
    • Jun.
    • G. D. Clifford and P. E. McSharry, "A nonlinear artificial model for generating realistic correlated ECG, BP and respiration," in Proc. Biosignal, Brno, Czech Republic, Jun. 2004, pp. 358-360.
    • (2004) Proc. Biosignal, Brno, Czech Republic , pp. 358-360
    • Clifford, G.D.1    McSharry, P.E.2
  • 53
    • 28144454007 scopus 로고    scopus 로고
    • Generating 24-Hour ECG, BP and respiratory signals with realistic linear and nonlinear clinical characteristics using a nonlinear model
    • Chicago, IL, Sep.
    • G. D. Clifford and P. E. McSharry, "Generating 24-Hour ECG, BP and respiratory signals with realistic linear and nonlinear clinical characteristics using a nonlinear model," in Proc. Comput. Cardiol., Chicago, IL, Sep. 2004, pp. 709-712.
    • (2004) Proc. Comput. Cardiol. , pp. 709-712
    • Clifford, G.D.1    McSharry, P.E.2
  • 54
    • 70449629723 scopus 로고    scopus 로고
    • Smart physiological signal simulator
    • Waterloo, ON, Canada, May
    • R. Phan and R. Leung, "Smart physiological signal simulator," in Proc. 5th Int. Conf. Upcoming Eng., Waterloo, ON, Canada, May 2006.
    • (2006) Proc. 5th Int. Conf. Upcoming Eng.
    • Phan, R.1    Leung, R.2
  • 57
    • 0030409070 scopus 로고    scopus 로고
    • A database to support development and evaluation of intelligence intensive care monitoring
    • Indianapolis, IN, Sep.
    • G. B. Moody and R. G. Mark, "A database to support development and evaluation of intelligence intensive care monitoring," in Proc. Comput. Cardiol., Indianapolis, IN, Sep. 1996, pp. 657-660.
    • (1996) Proc. Comput. Cardiol. , pp. 657-660
    • Moody, G.B.1    Mark, R.G.2
  • 58
    • 0034950598 scopus 로고    scopus 로고
    • PhysioNet: A Webbased resource for the study of physiologic signals
    • May/Jun.
    • G. B. Moody, R. G. Mark, and A. L. Goldberger, "PhysioNet: A Webbased resource for the study of physiologic signals," IEEE Eng. Med. Biol. Mag., vol.20, no.3, pp. 70-75, May/Jun. 2001.
    • (2001) IEEE Eng. Med. Biol. Mag. , vol.20 , Issue.3 , pp. 70-75
    • Moody, G.B.1    Mark, R.G.2    Goldberger, A.L.3
  • 59
    • 77955717725 scopus 로고    scopus 로고
    • [Online]: Available
    • [Online]: Available: http://cordis.europa.eu
  • 61
    • 74949141161 scopus 로고    scopus 로고
    • Oscillometric pressure pulse waveforms: Their current and prospective applications in biomedical instrumentation
    • Rodos, Greece, Jul.
    • J. Jilek and M. Stork, "Oscillometric pressure pulse waveforms: Their current and prospective applications in biomedical instrumentation," in Proc. 13th WSEAS Int. Conf. Syst., Rodos, Greece, Jul. 2009, pp. 133-138.
    • (2009) Proc. 13th WSEAS Int. Conf. Syst. , pp. 133-138
    • Jilek, J.1    Stork, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.