메뉴 건너뛰기




Volumn , Issue , 2007, Pages 386-391

Arterial blood pressure system modeling and signal analysis

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD VESSELS; COMPUTER SIMULATION; CORRELATION METHODS; MATHEMATICAL MODELS; PATIENT MONITORING; SIGNAL ANALYSIS;

EID: 34948897529     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CIRA.2007.382876     Document Type: Conference Paper
Times cited : (10)

References (14)
  • 1
    • 34948871423 scopus 로고    scopus 로고
    • http://commons.wikipedia.org
  • 2
    • 34948865108 scopus 로고    scopus 로고
    • http://commons.wikimedia.org/wiki/Image:Heart_lbelled_large.png
  • 4
    • 0031019916 scopus 로고    scopus 로고
    • Spectral analysis of systemic arterial pressure and heart rate signals as a prognostic tool for the prediction of patient outcome in the intensive care unit
    • February
    • Huey-Wen Yen MD, Shu-Shya Hseu MD, Lih-Chyn Lee MD, B.J. Terry MD, Tak-Yu Lee MD, Samuel H. H. Chan Phd, Spectral analysis of systemic arterial pressure and heart rate signals as a prognostic tool for the prediction of patient outcome in the intensive care unit, Critical Care Medicine 25:2, February 1997
    • (1997) Critical Care Medicine , vol.25 , pp. 2
    • Huey-Wen Yen, M.D.1    Shu-Shya Hseu, M.D.2    Lih-Chyn Lee, M.B.J.3    Terry, M.D.4    Tak-Yu Lee, M.D.5    Samuel, H.6    Chan Phd, H.7
  • 8
    • 30444451797 scopus 로고    scopus 로고
    • Causal cross-spectral analysis of heart rate and blood pressure variability for describing the impairment of the cardiovascular control in neurally mediated syncope
    • Jan
    • L. Faes, L. Widesott, M Del Greco, R. Antolini, G. Nollo, Causal cross-spectral analysis of heart rate and blood pressure variability for describing the impairment of the cardiovascular control in neurally mediated syncope, IEEE Transactions on Biomedical Engineering, 53(1), Jan. 2006
    • (2006) IEEE Transactions on Biomedical Engineering , vol.53 , Issue.1
    • Faes, L.1    Widesott, L.2    Del Greco, M.3    Antolini, R.4    Nollo, G.5
  • 13
    • 0023834947 scopus 로고
    • Estimation of the damping coefficient of fluid-filled catheter-transducer pressure-measuring system
    • Geddes L.A. and Bourland J.D. Estimation of the damping coefficient of fluid-filled catheter-transducer pressure-measuring system, Journal of Clinical Engineering 13(), 1988.
    • (1988) Journal of Clinical Engineering , vol.13
    • Geddes, L.A.1    Bourland, J.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.