Modeling of the cuffless blood pressure measurement errors for the evaluation of a wearable medical device

Author keywords

[No Author keywords available]

Indexed keywords

ADVANCEMENT OF MEDICAL INSTRUMENTATION (AAMI); THE BRITISH HYPERTENSION SOCIETY (BHS); WEARABLE MEDICAL DEVICE;

EID: 34547314515     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISSMDBS.2006.360109     Document Type: Conference Paper
Times cited : (7)

References (15)
  • 1
    • 0033049685 scopus 로고    scopus 로고
    • Accuracy relationship of blood pressure devices between the AAMI SP 10 standard and the British Hypertension Society protocols
    • M. Sun and R. Jones, "Accuracy relationship of blood pressure devices between the AAMI SP 10 standard and the British Hypertension Society protocols", Biomed. Instrum. Technol. 1999, 33(1):62-70.
    • (1999) Biomed. Instrum. Technol , vol.33 , Issue.1 , pp. 62-70
    • Sun, M.1    Jones, R.2
  • 2
    • 34547382305 scopus 로고    scopus 로고
    • Association for the Advancement of Medical Instrumentation. American National Standard for Electronic or Automated Sphygmomanometers, SP10-1987, ANSI/AAMI, 1987
    • Association for the Advancement of Medical Instrumentation. "American National Standard for Electronic or Automated Sphygmomanometers", SP10-1987, ANSI/AAMI, 1987
  • 3
    • 34547260095 scopus 로고    scopus 로고
    • Association for the Advancement of Medical Instrumentation. American National Standard for Electronic or Automated Sphygmomanometers, SP 10-1992, ANSI/AAMI, 1993.
    • Association for the Advancement of Medical Instrumentation. "American National Standard for Electronic or Automated Sphygmomanometers", SP 10-1992, ANSI/AAMI, 1993.
  • 4
    • 34547242167 scopus 로고    scopus 로고
    • Association for the Advancement of Medical Instrumentation, American National Standard for Manual, Electronic, or Automated Sphygmomanometers, SP 10-2002, ANSI/AAMI, 2003.
    • Association for the Advancement of Medical Instrumentation, "American National Standard for Manual, Electronic, or Automated Sphygmomanometers", SP 10-2002, ANSI/AAMI, 2003.
  • 5
    • 0025071770 scopus 로고
    • The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems
    • E. O'Brien et al., "The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems ", J. of Hypertension, 8, 1990, pp. 607-619.
    • (1990) J. of Hypertension , vol.8 , pp. 607-619
    • O'Brien, E.1
  • 6
    • 0001849046 scopus 로고
    • The British Hypertension Society Protocol for the Evaluation of Blood Pressure Measuring Device
    • E. O'Brien et al., "The British Hypertension Society Protocol for the Evaluation of Blood Pressure Measuring Device", J. of Hypertension, 11 (suppl 2), 1993, pp. S43-S63.
    • (1993) J. of Hypertension , vol.11 , Issue.SUPPL. 2
    • O'Brien, E.1
  • 7
    • 0035992060 scopus 로고    scopus 로고
    • Do We Need Another Protocol for Assessing the Validity of Blood Pressure Measuring Devices?
    • Norman R.C. Campbell and Donald W. McKay, "Do We Need Another Protocol for Assessing the Validity of Blood Pressure Measuring Devices? ", Blood Press Monit 2002, 7: 1-2.
    • (2002) Blood Press Monit , vol.7 , pp. 1-2
    • Campbell, N.R.C.1    McKay, D.W.2
  • 8
    • 0035992025 scopus 로고    scopus 로고
    • Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for Validating of Blood Pressure Measuring Devices in Adults
    • Eoin O'Brien et al. "Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for Validating of Blood Pressure Measuring Devices in Adults", Blood Press Monit 2002, 7: 3-17.
    • (2002) Blood Press Monit , vol.7 , pp. 3-17
    • O'Brien, E.1
  • 9
    • 0035799041 scopus 로고    scopus 로고
    • Blood, Pressure Measuring Devices: Recommendations of the European Society of Hypertension
    • Eoin O'Brien et al., "Blood, Pressure Measuring Devices: Recommendations of the European Society of Hypertension", BMJ, 2001, 322:531-536.
    • (2001) BMJ , vol.322 , pp. 531-536
    • O'Brien, E.1
  • 10
    • 0026924862 scopus 로고    scopus 로고
    • Eoin O'Brien, Fáinsía Mee, Neil Atkins, Kevin.O.'Malley, The Quest for Better Validation: A Critical Gomparison of the AAMI and BHS Validation Protocols for Ambulatory Blood Pressure Measurement Systems, Biomedical Instrumentation & Technology 1992; 26: 395-399
    • Eoin O'Brien, Fáinsía Mee, Neil Atkins, Kevin.O.'Malley, "The Quest for Better Validation: A Critical Gomparison of the AAMI and BHS Validation Protocols for Ambulatory Blood Pressure Measurement Systems", Biomedical Instrumentation & Technology 1992; 26: 395-399
  • 12
    • 33846906776 scopus 로고    scopus 로고
    • C.C.Y. Poon and Y.T. Zhang, Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time, in Proc. 27th Int. Annual Conf. on IEEE Engineering in.Medicine and Biology, Shanghai, China, Sept. 2005.
    • C.C.Y. Poon and Y.T. Zhang, "Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time", in Proc. 27th Int. Annual Conf. on IEEE Engineering in.Medicine and Biology, Shanghai, China, Sept. 2005.
  • 15
    • 34247990255 scopus 로고
    • On the Kolmogorov-Smirnov Test for Normality with Mean and Variance Unknown
    • Jun
    • Hubert W. Lilliefors, "On the Kolmogorov-Smirnov Test for Normality with Mean and Variance Unknown", J. of the American Statistical Association, Jun. 1967, Vol.62, No.318: 399-402.
    • (1967) J. of the American Statistical Association , vol.62 , Issue.318 , pp. 399-402
    • Lilliefors, H.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.