메뉴 건너뛰기




Volumn 23, Issue 4, 2010, Pages 253-260

In vitro aerosol deposition in the oropharyngeal region for staccato ® loxapine

Author keywords

aerosol; Alberta geometry; flow rate; inertial parameter; oropharyngeal deposition

Indexed keywords

LOXAPINE;

EID: 77955444920     PISSN: 19412711     EISSN: 19412703     Source Type: Journal    
DOI: 10.1089/jamp.2009.0814     Document Type: Article
Times cited : (28)

References (34)
  • 1
    • 0018823886 scopus 로고    scopus 로고
    • Experimental measurements and empirical modeling of the regional deposition of inhaled particles in humans
    • Chan TL, and Lippmann M: Experimental measurements and empirical modeling of the regional deposition of inhaled particles in humans. Am Ind Hyg Assoc J. 190;41:399-409.
    • Am Ind Hyg Assoc J. , vol.190 , Issue.41 , pp. 399-409
    • Chan, T.L.1    Lippmann, M.2
  • 2
    • 0020273631 scopus 로고
    • Measurements of the total and regional deposition of inhaled particles in the human respiratory tract
    • Emmett PC, Aitken JJ, and Hannan WJ: Measurements of the total and regional deposition of inhaled particles in the human respiratory tract. J Aerosol Sci. 1982;13:549-560.
    • (1982) J Aerosol Sci , vol.13 , pp. 549-560
    • Emmett, P.C.1    Aitken, J.J.2    Hannan, W.J.3
  • 3
    • 0018002742 scopus 로고
    • Regional deposition of 2.5-7.5 mm diameter inhaled particles in healthy male nonsmokers
    • Foord N, Black A, and Walsh M: Regional deposition of 2.5-7.5 mm diameter inhaled particles in healthy male nonsmokers. J Aerosol Sci.1978;9:343-357.
    • (1978) J Aerosol Sci , vol.9 , pp. 343-357
    • Foord, N.1    Black, A.2    Walsh, M.3
  • 4
    • 0024749908 scopus 로고
    • Deposition of inhaled particles in the oral airway during oronasal breathing
    • Bowes SM, and Swift DL: Deposition of inhaled particles in the oral airway during oronasal breathing. Aerosol Sci Technol. 1989;11:157-167.
    • (1989) Aerosol Sci Technol , vol.11 , pp. 157-167
    • Bowes, S.M.1    Swift, D.L.2
  • 6
    • 0028354478 scopus 로고
    • Lung deposition of budesonide inhaled via Turbuhaler-: A comparison with terbutaline sulphate in normal subjects
    • Borgström L, Bondesson E, Moré E, Trofast E, Newman SP: Lung deposition of budesonide inhaled via Turbuhaler-: a comparison with terbutaline sulphate in normal subjects. Eur Respir J. 1994;7:69-73.
    • (1994) Eur Respir J , vol.7 , pp. 69-73
    • Borgström, L.1    Bondesson, E.2    Moré, E.3    Trofast, E.4    Newman, S.P.5
  • 7
    • 0020317462 scopus 로고
    • Effect of various inhalation modes on the deposition of radioactive pressurized aerosols
    • Newman S, Pavia D, Garland N, and Clarke S: Effect of various inhalation modes on the deposition of radioactive pressurized aerosols. Eur J Respir Dis. 1982;119(Suppl):57-65.
    • (1982) Eur J Respir Dis , vol.119 , Issue.SUPPL. , pp. 57-65
    • Newman, S.1    Pavia, D.2    Garland, N.3    Clarke, S.4
  • 8
    • 0032438394 scopus 로고    scopus 로고
    • Improved airway targeting with the CFC-free HFA-beclomethasone metereddose inhaler compared with CFC-beclomethasone
    • Leach CL, Davidson PJ, and Boudreau JJ: Improved airway targeting with the CFC-free HFA-beclomethasone metereddose inhaler compared with CFC-beclomethasone. Eur Respir J. 1998;12:1346-1353.
    • (1998) Eur Respir J , vol.12 , pp. 1346-1353
    • Leach, C.L.1    Davidson, P.J.2    Boudreau, J.J.3
  • 9
    • 32644435870 scopus 로고    scopus 로고
    • High lung deposition of 99mTc-labeled ciclesonide administered via HFAMDA to patients with asthma
    • Newman S, Salmon A, Nave R, and Drollmann A: High lung deposition of 99mTc-labeled ciclesonide administered via HFAMDA to patients with asthma. Respir Med. 2006;100:375-384.
    • (2006) Respir Med , vol.100 , pp. 375-384
    • Newman, S.1    Salmon, A.2    Nave, R.3    Drollmann, A.4
  • 10
    • 0024993410 scopus 로고
    • A method for determination of the absolute pulmonary bioavailability of inhaled drugs: Terbutaline
    • Borgström L, and Nilsson M: A method for determination of the absolute pulmonary bioavailability of inhaled drugs: terbutaline. Pharm Res. 1990;7:1068-1070.
    • (1990) Pharm Res , vol.7 , pp. 1068-1070
    • Borgström, L.1    Nilsson, M.2
  • 11
    • 0035513523 scopus 로고    scopus 로고
    • Pharmacokinetics and systemic activity of fluticasone via Diskus- and pMDI, and of budesonide via Turbuhaler
    • Throsson L, Edsbäcker S, Kä llén A, and Löfdahl CG: Pharmacokinetics and systemic activity of fluticasone via Diskus- and pMDI, and of budesonide via Turbuhaler-. Br J Clin Pharmacol. 2001;52:529-538.
    • (2001) Br J Clin Pharmacol , vol.52 , pp. 529-538
    • Throsson, L.1    Edsbäcker, S.2    Kä Llén, A.3    Löfdahl, C.G.4
  • 12
    • 85010181389 scopus 로고
    • Intercomparison of experimental regional aerosol deposition data
    • Stahlhofen W, Rudolf G, and James AC: Intercomparison of experimental regional aerosol deposition data. J Aerosol Med. 1989;2:285-308.
    • (1989) J Aerosol Med , vol.2 , pp. 285-308
    • Stahlhofen, W.1    Rudolf, G.2    James, A.C.3
  • 13
    • 0001386952 scopus 로고
    • Regional deposition of particles in the human respiratory tract
    • Lee DHK, Falk SD, Murphy SD, Geiger SR (eds) American Physiological Society, Bethesda, MD
    • Lippmann M: Regional deposition of particles in the human respiratory tract. In: Lee DHK, Falk SD, Murphy SD, Geiger SR (eds). Handbook of Physiology-Reaction to Environmental Agents. American Physiological Society, Bethesda, MD, pp. 213-232, 1977.
    • (1977) Handbook of Physiology-Reaction to Environmental Agents , pp. 213-232
    • Lippmann, M.1
  • 14
    • 0019427067 scopus 로고
    • Statistical analysis of aerosol deposition in nose and mouth
    • Yu CP, Diu CK, and Soong TT: Statistical analysis of aerosol deposition in nose and mouth. Am Ind Hyg Assoc J. 1981; 42:726-733.
    • (1981) Am Ind Hyg Assoc J , vol.42 , pp. 726-733
    • Yu, C.P.1    Diu, C.K.2    Soong, T.T.3
  • 15
    • 0026995555 scopus 로고
    • Apparatus and method for measuring regional distribution of therapeutic aerosols and comparing delivery systems
    • Swift LD: Apparatus and method for measuring regional distribution of therapeutic aerosols and comparing delivery systems. J Aerosol Sci.1992;23(Suppl 1):495-498.
    • (1992) J Aerosol Sci , vol.23 , Issue.SUPPL. 1 , pp. 495-498
    • Swift, L.D.1
  • 16
    • 0030961927 scopus 로고    scopus 로고
    • An experimental method for measuring aerosol deposition efficiency in the human oral airway
    • Cheng KH, Yeh HC, and Swift DL: An experimental method for measuring aerosol deposition efficiency in the human oral airway. Am Ind Hyg Assoc J. 1997;58:207-213.
    • (1997) Am Ind Hyg Assoc J , vol.58 , pp. 207-213
    • Cheng, K.H.1    Yeh, H.C.2    Swift, D.L.3
  • 17
    • 0031281841 scopus 로고    scopus 로고
    • Measurements of airway dimensions and calculation of mass transfer characteristics of the human oral passage
    • Cheng KH, Cheng YS, Yeh HC, and Swift DL: Measurements of airway dimensions and calculation of mass transfer characteristics of the human oral passage. J Biomed Eng. 1997;119:475-482.
    • (1997) J Biomed Eng , vol.119 , pp. 475-482
    • Cheng, K.H.1    Cheng, Y.S.2    Yeh, H.C.3    Swift, D.L.4
  • 18
    • 0033286451 scopus 로고    scopus 로고
    • Particle deposition in a cast of human oral airways
    • Cheng YS, Zhou Y, and Chen TB: Particle deposition in a cast of human oral airways. Aerosol Sci and Technol. 1999;31:286-300.
    • (1999) Aerosol Sci and Technol , vol.31 , pp. 286-300
    • Cheng, Y.S.1    Zhou, Y.2    Chen, T.B.3
  • 19
    • 77955465440 scopus 로고    scopus 로고
    • Experimental measurements and computational modeling of the flow field in an idealized extrathoracic airway
    • Heenan, AF, Finlay WH, Matida EA, and Pollard A: Experimental measurements and computational modeling of the flow field in an idealized extrathoracic airway. J Aerosol Sci. 2003;39:572-591.
    • (2003) J Aerosol Sci , vol.39 , pp. 572-591
    • Heenan, A.F.1    Finlay, W.H.2    Matida, E.A.3    Pollard, A.4
  • 20
    • 34648816355 scopus 로고    scopus 로고
    • In vivo-in vitro comparison of deposition in threemouth- throatmodelswithQvar and Turbuhaler inhalers
    • Zhang Y, Gilbertson K, and Finlay WH: In vivo-in vitro comparison of deposition in threemouth-throatmodelswithQvar and Turbuhaler inhalers. J AerosolMed. 2007;20:227-235.
    • (2007) J AerosolMed , vol.20 , pp. 227-235
    • Zhang, Y.1    Gilbertson, K.2    Finlay, W.H.3
  • 21
    • 0034864345 scopus 로고    scopus 로고
    • In vitro monodisperse aerosol deposition in a mouth and throat with six different inhalation devices
    • DeHaan WH, and Finlay WH: In vitro monodisperse aerosol deposition in a mouth and throat with six different inhalation devices. J Aerosol Med. 2001;14:361-367.
    • (2001) J Aerosol Med , vol.14 , pp. 361-367
    • Dehaan, W.H.1    Finlay, W.H.2
  • 22
    • 1542291134 scopus 로고    scopus 로고
    • Predicting extrathoracic deposition from dry powder inhalers
    • DeHaan WH, and Finlay WH: Predicting extrathoracic deposition from dry powder inhalers. J Aerosol Sci. 2004;35:309-331.
    • (2004) J Aerosol Sci , vol.35 , pp. 309-331
    • Dehaan, W.H.1    Finlay, W.H.2
  • 23
    • 0036961772 scopus 로고    scopus 로고
    • In vitro effect of a holding chamber on the mouth-throat deposition of QVAR- (Hydrofluoroalkane-Beclomethasone Dipropionate)
    • Rahmatalla MF, Zuberbuhler PC, Lange CF, and Finlay WH: In vitro effect of a holding chamber on the mouth-throat deposition of QVAR- (Hydrofluoroalkane-Beclomethasone Dipropionate). J Aerosol Med. 2002;5:379-385.
    • (2002) J Aerosol Med , vol.5 , pp. 379-385
    • Rahmatalla, M.F.1    Zuberbuhler, P.C.2    Lange, C.F.3    Finlay, W.H.4
  • 24
    • 0345256446 scopus 로고    scopus 로고
    • Regional aerosol deposition and flow measurements in an idealized mouth- throat
    • Grgic B, Finlay WH, and Heenan AF: Regional aerosol deposition and flow measurements in an idealized mouth- throat. J Aerosol Sci. 2004;35:21-32.
    • (2004) J Aerosol Sci , vol.35 , pp. 21-32
    • Grgic, B.1    Finlay, W.H.2    Heenan, A.F.3
  • 25
    • 3242722612 scopus 로고    scopus 로고
    • In vitro intersubject and intrasubject deposition measurements in realistic mouth-throat geometries
    • Grgic B, Finlay WH, Burnell PKP, and Heenan AF: In vitro intersubject and intrasubject deposition measurements in realistic mouth-throat geometries. J Aerosol Sci. 2004;35: 1025-1040.
    • (2004) J Aerosol Sci , vol.35 , pp. 1025-1040
    • Grgic, B.1    Finlay, W.H.2    Pkp, B.3    Heenan, A.F.4
  • 28
    • 0034019232 scopus 로고    scopus 로고
    • On the suitability of k-e turbulence modeling for aerosol deposition in the mouth and throat: A comparison experiment
    • Stapleton KW, Guentsch E, Hoskinson MK, and Finlay WH: On the suitability of k-e turbulence modeling for aerosol deposition in the mouth and throat: a comparison experiment. J Aerosol Sci. 2000;6:739-749.
    • (2000) J Aerosol Sci , vol.6 , pp. 739-749
    • Stapleton, K.W.1    Guentsch, E.2    Hoskinson, M.K.3    Finlay, W.H.4
  • 29
    • 0027228520 scopus 로고
    • The relationship between powder inhaler resistance and peak inspiratory conditions in healthy volunteers-implications for in vitro testing
    • Clark AR, and Hollingworth AM: The relationship between powder inhaler resistance and peak inspiratory conditions in healthy volunteers-implications for in vitro testing. J Aerosol Med. 1993;6:99-110.
    • (1993) J Aerosol Med , vol.6 , pp. 99-110
    • Clark, A.R.1    Hollingworth, A.M.2
  • 30
    • 77955448824 scopus 로고    scopus 로고
    • USP-NF: Chapter 601: Physical tests and determinations
    • United States Pharmacopeia
    • United States Pharmacopeia; USP-NF: Chapter 601: Physical Tests and Determinations. United States Pharmacopeia, Rockville, MD, 2008.
    • (2008) United States Pharmacopeia, Rockville, MD
  • 31
    • 1942468906 scopus 로고    scopus 로고
    • In-vitro intra- and interinhaler rate-dependent dosage emission from a combination of Budesonide and Eformoterol in a dry powder inhaler
    • Tarsin W, Assi KH, and Chrystyn H: In-vitro intra- and interinhaler rate-dependent dosage emission from a combination of Budesonide and Eformoterol in a dry powder inhaler. J Aerosol Med. 2004;27:25-32.
    • (2004) J Aerosol Med , vol.27 , pp. 25-32
    • Tarsin, W.1    Assi, K.H.2    Chrystyn, H.3
  • 32
    • 85046524674 scopus 로고    scopus 로고
    • In vitro comparison of three salbutamol-containing multidose dry powder inhalers
    • Palander A, Mattila T, Karhu Mika, and Muttonen E: In vitro comparison of three salbutamol-containing multidose dry powder inhalers. Clin Drug Invest. 2004;20:25-33.
    • (2004) Clin Drug Invest , vol.20 , pp. 25-33
    • Palander, A.1    Mattila, T.2    Mika, K.3    Muttonen, E.4
  • 33
    • 57749207935 scopus 로고    scopus 로고
    • The pharmacokinetics and bioavailability of prochlorperazine delivered as a thermally generated aerosol in a single breath to volunteers
    • Avram MJ, Spyker DA, Henthorn TK, and Cassella JV: The pharmacokinetics and bioavailability of prochlorperazine delivered as a thermally generated aerosol in a single breath to volunteers. Clin Pharmacol Ther. 2009;85:71-77.
    • (2009) Clin Pharmacol Ther , vol.85 , pp. 71-77
    • Avram, M.J.1    Spyker, D.A.2    Henthorn, T.K.3    Cassella, J.V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.