메뉴 건너뛰기




Volumn 32, Issue 2, 2010, Pages 434-440

Single breathhold cardiac CINE imaging with multi-echo three-dimensional hybrid radial SSFP acquisition

Author keywords

3D; Breathhold; Cardiac function; Multi echo; Radial; SSFP

Indexed keywords

ADULT; ARTICLE; CINEANGIOCARDIOGRAPHY; FEMALE; HEART CYCLE; HEART FUNCTION; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE VOLUME; HUMAN; HUMAN EXPERIMENT; MALE; NORMAL HUMAN; PRIORITY JOURNAL; STEADY STATE FREE PRECESSION; THREE DIMENSIONAL IMAGING;

EID: 77955350410     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.22269     Document Type: Article
Times cited : (16)

References (30)
  • 2
    • 4344647591 scopus 로고    scopus 로고
    • 3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI
    • DOI 10.1002/jmri.20145
    • Peters DC, Ennis DB, Rohatgi P, Syed MA, McVeigh ER, Arai AE. 3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI. J Magn Reson Imaging 2004;20:411-416. (Pubitemid 39121939)
    • (2004) Journal of Magnetic Resonance Imaging , vol.20 , Issue.3 , pp. 411-416
    • Peters, D.C.1    Ennis, D.B.2    Rohatgi, P.3    Syed, M.A.4    McVeigh, E.R.5    Arai, A.E.6
  • 4
    • 45849133408 scopus 로고    scopus 로고
    • Rapid assessment of regional and global left ventricular function using three-dimensional k-t BLAST imaging
    • Huber S, Muthupillai R, Mojibian H, Cheong B, Kouwenhoven M, Flamm SD. Rapid assessment of regional and global left ventricular function using three-dimensional k-t BLAST imaging. Magn Reson Imaging 2008;26:727-738.
    • (2008) Magn Reson Imaging , vol.26 , pp. 727-738
    • Huber, S.1    Muthupillai, R.2    Mojibian, H.3    Cheong, B.4    Kouwenhoven, M.5    Flamm, S.D.6
  • 6
    • 0036206953 scopus 로고    scopus 로고
    • MR imaging of the heart with cine true fast imaging with steady-state precession: Influence of spatial and temporal resolutions on left ventricular functional parameters
    • Miller S, Simonetti OP, Carr J, Kramer U, Finn JP. MR Imaging of the heart with cine true fast imaging with steady-state precession: influence of spatial and temporal resolutions on left ventricular functional parameters. Radiology 2002;223:263-269. (Pubitemid 34258218)
    • (2002) Radiology , vol.223 , Issue.1 , pp. 263-269
    • Miller, S.1    Simonetti, O.P.2    Carr, J.3    Kramer, U.4    Finn, J.P.5
  • 8
    • 77955293409 scopus 로고    scopus 로고
    • Respiratory and cardiac self-gated free-breathing cardiac cine imaging with multi-echo 3D hybrid radial SSFP acquisition
    • Liu J, Spincemaille P, Codella CFN, Nguyen T, Prince MR, Wang Y. Respiratory and cardiac self-gated free-breathing cardiac cine imaging with multi-echo 3D hybrid radial SSFP acquisition. Magn Reson Imaging 2010;63:1230-1237.
    • (2010) Magn Reson Imaging , vol.63 , pp. 1230-1237
    • Liu, J.1    Spincemaille, P.2    Codella, C.F.N.3    Nguyen, T.4    Prince, M.R.5    Wang, Y.6
  • 10
    • 0037925300 scopus 로고    scopus 로고
    • Centering the projection reconstruction trajectory: Reducing gradient delay errors
    • Peters DC, Derbyshire JA, McVeigh ER. Centering the projection reconstruction trajectory: reducing gradient delay errors. Magn Reson Med 2003;50:1-6.
    • (2003) Magn Reson Med , vol.50 , pp. 1-6
    • Peters, D.C.1    Derbyshire, J.A.2    McVeigh, E.R.3
  • 11
    • 33846101573 scopus 로고    scopus 로고
    • Consistent non-Cartesian off-axis MRI quality: Calibrating and removing multiple sources of demodulation phase errors
    • DOI 10.1002/mrm.21092
    • Jung Y, Jashnani Y, Kijowski R, Block WF. Consistent non-Cartesian off-axis MRI quality: calibrating and removing multiple sources of demodulation phase errors. Magn Reson Med 2007;57: 206-212. (Pubitemid 46067951)
    • (2007) Magnetic Resonance in Medicine , vol.57 , Issue.1 , pp. 206-211
    • Jung, Y.1    Jashnani, Y.2    Kijowski, R.3    Block, W.F.4
  • 12
    • 14744296815 scopus 로고    scopus 로고
    • Rapid fat-suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction
    • DOI 10.1002/mrm.20389
    • Lu A, Brodsky E, Grist TM, Block WF. Rapid fat-suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction. Magn Reson Med 2005;53: 692-699. (Pubitemid 40332291)
    • (2005) Magnetic Resonance in Medicine , vol.53 , Issue.3 , pp. 692-699
    • Lu, A.1    Brodsky, E.2    Grist, T.M.3    Block, W.F.4
  • 14
    • 21244491945 scopus 로고    scopus 로고
    • Analysis and compensation of eddy currents in balanced SSFP
    • DOI 10.1002/mrm.20527
    • Bieri O, Markl M, Scheffler K. Analysis and compensation of eddy currents in balanced SSFP. Magn Reson Med 2005;54: 129-137. (Pubitemid 40898405)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.1 , pp. 129-137
    • Bieri, O.1    Markl, M.2    Scheffler, K.3
  • 15
    • 26844509096 scopus 로고    scopus 로고
    • Flow compensation in balanced SSFP sequences
    • DOI 10.1002/mrm.20619
    • Bieri O, Scheffler K. Flow compensation in balanced SSFP sequences. Magn Reson Med 2005;54:901-907. (Pubitemid 41457062)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.4 , pp. 901-907
    • Bieri, O.1    Scheffler, K.2
  • 17
    • 0036319895 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory
    • DOI 10.1002/mrm.10212
    • Barger AV, Block WF, Toropov Y, Grist TM, Mistretta CA. Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. Magn Reson Med 2002;48:297-305. (Pubitemid 34809418)
    • (2002) Magnetic Resonance in Medicine , vol.48 , Issue.2 , pp. 297-305
    • Barger, A.V.1    Block, W.F.2    Toropov, Y.3    Grist, T.M.4    Mistretta, C.A.5
  • 18
    • 0030884045 scopus 로고    scopus 로고
    • Real-time interactive MRI on a conventional scanner
    • Kerr AB, Pauly JM, Hu BS, et al. Real-time interactive MRI on a conventional scanner. Magn Reson Med 1997;38:355-367.
    • (1997) Magn Reson Med , vol.38 , pp. 355-367
    • Kerr, A.B.1    Pauly, J.M.2    Hu, B.S.3
  • 20
    • 60549117534 scopus 로고    scopus 로고
    • Temporal stability of adaptive 3D radial MRI using multidimensional golden means
    • Chan RW, Ramsay EA, Cunningham CH, Plewes DB. Temporal stability of adaptive 3D radial MRI using multidimensional golden means. Magn Reson Med 2009;61:354-363.
    • (2009) Magn Reson Med , vol.61 , pp. 354-363
    • Chan, R.W.1    Ramsay, E.A.2    Cunningham, C.H.3    Plewes, D.B.4
  • 21
    • 0035180571 scopus 로고    scopus 로고
    • Real-time cardiac cine imaging with SPIDER: Steady-state projection imaging with dynamic echo-train readout
    • Larson AC, Simonetti OP. Real-time cardiac cine imaging with SPIDER: steady-state projection imaging with dynamic echo-train readout. Magn Reson Med 2001;46:1059-1066.
    • (2001) Magn Reson Med , vol.46 , pp. 1059-1066
    • Larson, A.C.1    Simonetti, O.P.2
  • 22
    • 0032751897 scopus 로고    scopus 로고
    • Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI
    • DOI 10.1002/(SICI)1522-2594(199911)42:5<813::AID-MRM1>3.0.CO;2-S
    • Madore B, Glover GH, Pelc NJ. Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI. Magn Reson Med 1999;42: 813-828. (Pubitemid 29521471)
    • (1999) Magnetic Resonance in Medicine , vol.42 , Issue.5 , pp. 813-828
    • Madore, B.1    Glover, G.H.2    Pelc, N.J.3
  • 23
    • 0242385483 scopus 로고    scopus 로고
    • K-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • Tsao J, Boesiger P, Pruessmann KP. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003;50:1031-1042.
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 25
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • DOI 10.1002/mrm.21391
    • Lustig M, Donoho D, Pauly JM. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007;58:1182-1195. (Pubitemid 350234205)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.6 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 26
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Bornert P, Boesiger P. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001;46:638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Bornert, P.3    Boesiger, P.4
  • 27
    • 77955369455 scopus 로고    scopus 로고
    • Self-calibrated multi-echo sequences: Use of conjugate gradient method with radial trajectories to remove phase cancellation
    • abstract 979
    • Jung Y, Block WF, Samsonov A. Self-calibrated multi-echo sequences: use of conjugate gradient method with radial trajectories to remove phase cancellation. In: Proceedings of the 15th Annual Meeting of ISMRM, Berlin, 2007. (abstract 979).
    • Proceedings of the 15th Annual Meeting of ISMRM, Berlin, 2007
    • Jung, Y.1    Block, W.F.2    Samsonov, A.3
  • 28
    • 66149100092 scopus 로고    scopus 로고
    • 3D diffusion tensor MRI with isotropic resolution using a steady-state radial acquisition
    • Jung Y, Samsonov AA, Block WF, et al. 3D diffusion tensor MRI with isotropic resolution using a steady-state radial acquisition. J Magn Reson Imaging 2009;29:1175-1184.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 1175-1184
    • Jung, Y.1    Samsonov, A.A.2    Block, W.F.3
  • 30
    • 0023872880 scopus 로고
    • An analysis of fast imaging sequences with steady-state transverse magnetization refocusing
    • Zur Y, Stokar S, Bendel P. An analysis of fast imaging sequences with steady-state transverse magnetization refocusing. Magn Reson Med 1988;6:175-193. (Pubitemid 18066057)
    • (1988) Magnetic Resonance in Medicine , vol.6 , Issue.2 , pp. 175-193
    • Zur, Y.1    Stokar, S.2    Bendel, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.