메뉴 건너뛰기




Volumn 12, Issue 7, 2010, Pages 436-438

Magnetic resonance imaging and implantable cardiac electronic devices: It's not what we can do, it's what we should do

Author keywords

[No Author keywords available]

Indexed keywords

ADVERSE OUTCOME; ARTIFICIAL HEART PACEMAKER; CARDIOVASCULAR EQUIPMENT; CLINICAL TRIAL; CONSENSUS DEVELOPMENT; DEFIBRILLATOR; EDITORIAL; ELECTRODE; ELECTROMAGNETIC FIELD; HEART ARRHYTHMIA; HEART PACING; HIGH RISK PATIENT; HUMAN; LOOP RECORDER; NUCLEAR MAGNETIC RESONANCE IMAGING; PATIENT MONITORING; PATIENT SAFETY; RISK BENEFIT ANALYSIS; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; PROSTHESES AND ORTHOSES;

EID: 77955072528     PISSN: 15651088     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Editorial
Times cited : (6)

References (20)
  • 1
    • 37349049968 scopus 로고    scopus 로고
    • Safety of MRI in patients with cardiovascular devices
    • Levine GN, Gomes AS, Arai AE, et al. Safety of MRI in patients with cardiovascular devices. Circulation 2007; 116: 2878-91.
    • (2007) Circulation , vol.116 , pp. 2878-2891
    • Levine, G.N.1    Gomes, A.S.2    Arai, A.E.3
  • 2
    • 44649139918 scopus 로고    scopus 로고
    • MRI in individuals with cardiovascular implantable electronic devices
    • Roguin A, Schwitter J, Vahlhaus C, et al. MRI in individuals with cardiovascular implantable electronic devices. Europace 2008; 10: 336-46.
    • (2008) Europace , vol.10 , pp. 336-346
    • Roguin, A.1    Schwitter, J.2    Vahlhaus, C.3
  • 3
    • 33748741479 scopus 로고    scopus 로고
    • FDA perspective: MRI of pacemaker and ICD patients
    • Faris O P, Shein M. FDA perspective: MRI of pacemaker and ICD patients. Circulation 2006; 114: 1232-3.
    • (2006) Circulation , vol.114 , pp. 1232-1233
    • Faris, O.P.1    Shein, M.2
  • 4
    • 67651027225 scopus 로고    scopus 로고
    • Magnetic resonance imaging in patients with implantable cardioverter-defibrillators and pacemakers
    • Roguin A. Magnetic resonance imaging in patients with implantable cardioverter-defibrillators and pacemakers. J Am Coll Cardiol 2009; 54: 556-7.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 556-557
    • Roguin, A.1
  • 5
    • 0036112470 scopus 로고    scopus 로고
    • American College of Radiology White Paper on MR Safety
    • Kanal E, Borgstede J P, Barkovich AJ, et al. American College of Radiology White Paper on MR Safety. AJR Am J Roentgenol 2002; 178: 1335-42.
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 1335-1342
    • Kanal, E.1    Borgstede, J.P.2    Barkovich, A.J.3
  • 6
    • 3543116170 scopus 로고    scopus 로고
    • Modern pacemaker and ICD systems can be MRI safe: In-vitro and in-vivo assessment of safety and function at 1.5T
    • Roguin A, Zviman MM, Meininger GR, et al. Modern pacemaker and ICD systems can be MRI safe: in-vitro and in-vivo assessment of safety and function at 1.5T. Circulation 2004; 110: 475-82.
    • (2004) Circulation , vol.110 , pp. 475-482
    • Roguin, A.1    Zviman, M.M.2    Meininger, G.R.3
  • 7
    • 14144252694 scopus 로고    scopus 로고
    • In vivo heating of pacemaker leads during magnetic resonance imaging
    • Luechinger R, Zeijlemaker VA, Pedersen EM, et al. In vivo heating of pacemaker leads during magnetic resonance imaging. Eur Heart J 2005; 26(4): 376-83.
    • (2005) Eur Heart J , vol.26 , Issue.4 , pp. 376-383
    • Luechinger, R.1    Zeijlemaker, V.A.2    Pedersen, E.M.3
  • 8
    • 0038221323 scopus 로고    scopus 로고
    • Cardiac pacemakers, ICDs, and loop recorder: Evaluation of translational attraction using conventional (long-bore) and short-bore 1.5- and 3.0-Tesla MR systems
    • Shellock FG, Tkach JA, Ruggieri PM, et al. Cardiac pacemakers, ICDs, and loop recorder: evaluation of translational attraction using conventional (long-bore) and short-bore 1.5- and 3.0-Tesla MR systems. J Cardiovasc Magn Reson 2003; 5(2): 387-97.
    • (2003) J Cardiovasc Magn Reson , vol.5 , Issue.2 , pp. 387-397
    • Shellock, F.G.1    Tkach, J.A.2    Ruggieri, P.M.3
  • 9
    • 0036800991 scopus 로고    scopus 로고
    • Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: Are reed switches always closed in strong magnetic felds?
    • Luechinger R, Duru F, Zeijlemaker VA, et al. Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: are reed switches always closed in strong magnetic felds? Pacing Clin Electrophysiol 2002; 25(10): 1419-23.
    • (2002) Pacing Clin Electrophysiol , vol.25 , Issue.10 , pp. 1419-1423
    • Luechinger, R.1    Duru, F.2    Zeijlemaker, V.A.3
  • 11
    • 33748740922 scopus 로고    scopus 로고
    • Clinical utility and safety of a protocol for noncardiac and cardiac MRI of patients with permanent pacemakers and ICDS at 1.5T
    • Nazarian S, Roguin A, Zviman MM, et al. Clinical utility and safety of a protocol for noncardiac and cardiac MRI of patients with permanent pacemakers and ICDS at 1.5T. Circulation 2006; 114: 1277-84.
    • (2006) Circulation , vol.114 , pp. 1277-1284
    • Nazarian, S.1    Roguin, A.2    Zviman, M.M.3
  • 12
    • 33748752144 scopus 로고    scopus 로고
    • Strategy for safe performance of extrathoracic MRI at 1.5T in the presence of cardiac pacemakers in non- pacemaker-dependent patients: A prospective study with 115 examinations
    • Sommer T, Naehle C P, Yang A, et al. Strategy for safe performance of extrathoracic MRI at 1.5T in the presence of cardiac pacemakers in non- pacemaker-dependent patients: a prospective study with 115 examinations. Circulation 2006; 114: 1285-92.
    • (2006) Circulation , vol.114 , pp. 1285-1292
    • Sommer, T.1    Naehle, C.P.2    Yang, A.3
  • 13
    • 55249119369 scopus 로고    scopus 로고
    • Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla
    • Gimbel JR. Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla. Pacing Clin Electrophysiol 2008; 31(7): 795-801.
    • (2008) Pacing Clin Electrophysiol , vol.31 , Issue.7 , pp. 795-801
    • Gimbel, J.R.1
  • 15
    • 67651016691 scopus 로고    scopus 로고
    • Magnetic resonance imaging at 1.5-T in patients with implantable cardioverter-defibrillators
    • Naehle C P, Strach K, Tomas D, et al. Magnetic resonance imaging at 1.5-T in patients with implantable cardioverter-defibrillators. J Am Coll Cardiol 2009; 54(6): 549-55.
    • (2009) J Am Coll Cardiol , vol.54 , Issue.6 , pp. 549-555
    • Naehle, C.P.1    Strach, K.2    Tomas, D.3
  • 16
    • 33244465638 scopus 로고    scopus 로고
    • Magnetic resonance imaging for patients with permanent pacemakers: Initial clinical experience
    • Goldsher D, Amikam S, Boulos M, et al. Magnetic resonance imaging for patients with permanent pacemakers: initial clinical experience. IMAJ Isr Med Assoc J 2006; 8: 91-4.
    • (2006) IMAJ Isr Med Assoc J , vol.8 , pp. 91-94
    • Goldsher, D.1    Amikam, S.2    Boulos, M.3
  • 17
    • 77955080555 scopus 로고    scopus 로고
    • Pacemakers and, magnetic resonance imaging: No longer an absolute contraindication, when scanned correctly
    • Halshtok O, Goitein O, Abu Sham'a R, Granit H, Glikson M, Konen E. Pacemakers and, magnetic resonance imaging: no longer an absolute contraindication, when scanned correctly. IMAJ Isr Med Assoc J 2010; 12: 391-5.
    • (2010) IMAJ Isr Med Assoc J , vol.12 , pp. 391-395
    • Halshtok, O.1    Goitein, O.2    Sham'a, R.A.3    Granit, H.4    Glikson, M.5    Konen, E.6
  • 18
    • 33644809598 scopus 로고    scopus 로고
    • Safe scanning, but frequent artifacts mimicking bradycardia and tachycardia during magnetic resonance imaging (MRI) in patients with an implantable loop recorder (ILR)
    • Gimbel JR, Zarghami J, Machado C, Wilkof BL. Safe scanning, but frequent artifacts mimicking bradycardia and tachycardia during magnetic resonance imaging (MRI) in patients with an implantable loop recorder (ILR). Ann Noninvasive Electrocardiol 2005; 10: 404-8.
    • (2005) Ann Noninvasive Electrocardiol , vol.10 , pp. 404-408
    • Gimbel, J.R.1    Zarghami, J.2    Machado, C.3    Wilkof, B.L.4
  • 19
    • 59149092325 scopus 로고    scopus 로고
    • Safety of magnetic resonance imaging of patients with a new Medtronic EnRhythm MRI SureScan pacing system: Clinical study design
    • Sutton R, Kanal E, Wilkof BL, et al. Safety of magnetic resonance imaging of patients with a new Medtronic EnRhythm MRI SureScan pacing system: clinical study design. Tri als 2008; 9: 68.
    • (2008) Tri Als , vol.9 , pp. 68
    • Sutton, R.1    Kanal, E.2    Wilkof, B.L.3
  • 20
    • 67651079050 scopus 로고    scopus 로고
    • Safety and efcacy of new pacemaker system that can be used in MRI environment: First clinical trial results
    • Sommer T, Kanal E, Taborsky M, et al. Safety and efcacy of new pacemaker system that can be used in MRI environment: first clinical trial results. Eur Heart J 2008; 29(Suppl): 21-2.
    • (2008) Eur Heart J , vol.29 , Issue.SUPPL. , pp. 21-22
    • Sommer, T.1    Kanal, E.2    Taborsky, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.