메뉴 건너뛰기




Volumn 94, Issue 3, 2010, Pages 953-960

Tissue response to the components of a hydroxyapatite-coated composite femoral implant

Author keywords

Bone apposition; Carbon fiber composites; Hip implant; Hydroxyapatite coating; Tissue response

Indexed keywords

BONE APPOSITION; CARBON FIBER COMPOSITE; HIP IMPLANTS; HYDROXYAPATITE COATING; TISSUE RESPONSE;

EID: 77954811734     PISSN: 15493296     EISSN: 15524965     Source Type: Journal    
DOI: 10.1002/jbm.a.32758     Document Type: Article
Times cited : (18)

References (44)
  • 3
    • 0036084025 scopus 로고    scopus 로고
    • Management of periprosthetic fractures: The hip
    • Berry DJ. Management of periprosthetic fractures: The hip. J Arthroplasty 2002;17(Suppl 1):11-13.
    • (2002) J Arthroplasty , vol.17 , Issue.SUPPL. 1 , pp. 11-13
    • Berry, D.J.1
  • 4
    • 0033861254 scopus 로고    scopus 로고
    • Long-term registration has improved the quality of hip replacement
    • Herberts P, Malchau H. Long-term registration has improved the quality of hip replacement. Acta Orthop Scand 2000;71:111-121.
    • (2000) Acta Orthop Scand , vol.71 , pp. 111-121
    • Herberts, P.1    Malchau, H.2
  • 5
    • 0034986592 scopus 로고    scopus 로고
    • Hip disease and the prognosis of total hip replacements. A review of 53 698 primary total hip replacements reported to the Norwegian Arthroplasty Register 1987-99
    • Furnes O, Lie SA, Espehaug B, Vollset SE, Engesaeter LB, Havelin LI. Hip disease and the prognosis of total hip replacements. A review of 53 698 primary total hip replacements reported to the Norwegian Arthroplasty Register 1987-99. J Bone Joint Surg Br 2001;83:579-586.
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 579-586
    • Furnes, O.1    Lie, S.A.2    Espehaug, B.3    Vollset, S.E.4    Engesaeter, L.B.5    Havelin, L.I.6
  • 6
    • 14744293045 scopus 로고    scopus 로고
    • Total hip arthroplasty for primary osteoarthrosis in younger patients in the Finnish arthroplasty register
    • DOI 10.1080/00016470510030292, PII Y1R54BUWBDJBMF8H
    • Eskelinen A, Remes V, Helenius I, Pulkkinen P, Nevalainen J, Paavolainen P. Total hip arthroplasty for primary osteoarthrosis in younger patients in the Finnish arthroplasty register. Acta Orthop 2005;76:28-41. (Pubitemid 44576544)
    • (2005) Acta Orthopaedica , vol.76 , Issue.1 , pp. 28-41
    • Eskelinen, A.1    Remes, V.2    Helenius, I.3    Pulkkinen, P.4    Nevalainen, J.5    Paavolainen, P.6
  • 7
    • 18944375927 scopus 로고    scopus 로고
    • Long-term results of the cementless porous-coated anatomic total hip prosthesis
    • Kim Y-H. Long-term results of the cementless porous-coated anatomic total hip prosthesis. J Bone Joint Surg Br 2005;87:623-627.
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 623-627
    • Kim, Y.-H.1
  • 10
    • 33947262218 scopus 로고    scopus 로고
    • Mechanisms of disease: Molecular insights into aseptic loosening of orthopedic implants
    • DOI 10.1038/ncprheum0428, PII NCPRHEUM0428
    • Drees P, Eckardt A, Gay RE, Gay S, Huber LC. Mechanisms of disease: Molecular insights into aseptic loosening of orthopedic implants. Nat Clin Pract Rheumatol 2007;3:165-171. (Pubitemid 46416265)
    • (2007) Nature Clinical Practice Rheumatology , vol.3 , Issue.3 , pp. 165-171
    • Drees, P.1    Eckardt, A.2    Gay, R.E.3    Gay, S.4    Huber, L.C.5
  • 11
    • 0027508108 scopus 로고
    • Mechanisms of bone loss associated with total hip replacement
    • Jacobs JJ, Sumner DR, Galante JO. Mechanisms of bone loss associated with total hip replacement. Orthop Clin North Am 1993;24:583-590.
    • (1993) Orthop Clin North Am , vol.24 , pp. 583-590
    • Jacobs, J.J.1    Sumner, D.R.2    Galante, J.O.3
  • 12
    • 0025695692 scopus 로고
    • The effect of stem stiffness on femoral bone resorption after canine porous-coated total hip arthroplasty
    • Bobyn JD, Glassman AH, Goto H, Krygier JJ, Miller JE, Brooks CE. The effect of stem stiffness on femoral bone resorption after canine porous-coated total hip arthroplasty. Clin Orthop Relat Res 1990;261:196-213.
    • (1990) Clin Orthop Relat Res , vol.261 , pp. 196-213
    • Bobyn, J.D.1    Glassman, A.H.2    Goto, H.3    Krygier, J.J.4    Miller, J.E.5    Brooks, C.E.6
  • 13
    • 0026519501 scopus 로고
    • Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty
    • Bobyn JD, Mortimer ES, Glassman AH, Engh CA, Miller JE, Brooks CE. Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty. Clin Orthop Relat Res 1992;274:79-96.
    • (1992) Clin Orthop Relat Res , vol.274 , pp. 79-96
    • Bobyn, J.D.1    Mortimer, E.S.2    Glassman, A.H.3    Engh, C.A.4    Miller, J.E.5    Brooks, C.E.6
  • 15
    • 0026457532 scopus 로고
    • Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses
    • Engh CA, O'Connor D, Jasty M, Mcgovern TF, Bobyn JD, Harris WH. Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses. Clin Orthop Relat Res 1992;285:13-29.
    • (1992) Clin Orthop Relat Res , vol.285 , pp. 13-29
    • Engh, C.A.1    O'Connor, D.2    Jasty, M.3    Mcgovern, T.F.4    Bobyn, J.D.5    Harris, W.H.6
  • 16
    • 33845418940 scopus 로고    scopus 로고
    • New femoral designs: Do they influence stress shielding?
    • Glassman AH, Bobyn JD, Tanzer M. New femoral designs: Do they influence stress shielding? Clin Orthop Relat Res 2006;453:64-74.
    • (2006) Clin Orthop Relat Res , vol.453 , pp. 64-74
    • Glassman, A.H.1    Bobyn, J.D.2    Tanzer, M.3
  • 17
    • 0028813516 scopus 로고
    • Titanium as the material of choice for cementless femoral components in total hip arthroplasty
    • Head WC, Bauk DJ, Emerson RHJ. Titanium as the material of choice for cementless femoral components in total hip arthroplasty. Clin Orthop 1995;311:85-90.
    • (1995) Clin Orthop , vol.311 , pp. 85-90
    • Head, W.C.1    Bauk, D.J.2    Emerson, R.H.J.3
  • 18
    • 0026560894 scopus 로고
    • Determinants of stress shielding: Design versus materials versus interface
    • Sumner DR, Galante JO. Determinants of stress shielding: Design versus materials versus interface. Clin Orthop Relat Res 1992;274:202-212.
    • (1992) Clin Orthop Relat Res , vol.274 , pp. 202-212
    • Sumner, D.R.1    Galante, J.O.2
  • 19
    • 36849009829 scopus 로고    scopus 로고
    • Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty
    • Jacobs CA, Christensen CP, Greenwald AS, Mckellop H. Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty. J Bone Joint Surg Am 2007;89:2779-2786.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 2779-2786
    • Jacobs, C.A.1    Christensen, C.P.2    Greenwald, A.S.3    Mckellop, H.4
  • 20
    • 0032868136 scopus 로고    scopus 로고
    • Fixation and bearing surfaces for the next millennium
    • Bobyn JD. Fixation and bearing surfaces for the next millennium. Orthopedics 1999;22:810-812.
    • (1999) Orthopedics , vol.22 , pp. 810-812
    • Bobyn, J.D.1
  • 21
    • 2342552077 scopus 로고    scopus 로고
    • Bearing surface options for total hip replacement in young patients
    • Heisel C, Silva M, Schmalzried TP. Bearing surface options for total hip replacement in young patients. Instr Course Lect 2004;53:49-65.
    • (2004) Instr Course Lect , vol.53 , pp. 49-65
    • Heisel, C.1    Silva, M.2    Schmalzried, T.P.3
  • 25
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running, measured in two patients
    • Bergmann G, Graichen F, Rohlmann A. Hip joint loading during walking and running, measured in two patients. J Biomech 1993;26:969-990.
    • (1993) J Biomech , vol.26 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 27
    • 0031444317 scopus 로고    scopus 로고
    • Fatigue fracture of a forged cobalt-chromium-molybdenum femoral component inserted with cement. A report of ten cases
    • Woolson ST, Milbauer JP, Bobyn JD, Yue S, Maloney WJ. Fatigue fracture of a forged cobalt-chromium-molybdenum femoral component inserted with cement. A report of ten cases. J Bone Joint Surg Am 1997;79:1842-1848.
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 1842-1848
    • Woolson, S.T.1    Milbauer, J.P.2    Bobyn, J.D.3    Yue, S.4    Maloney, W.J.5
  • 28
    • 34547549757 scopus 로고    scopus 로고
    • Fracture of the hydroxyapatite-ceramic-coated JRI-Furlong femoral component: Body mass index and implications for selection of the implant
    • Harvie P, Haroon M, Henderson N, El-Guindi M. Fracture of the hydroxyapatite-ceramic-coated JRI-Furlong femoral component: Body mass index and implications for selection of the implant. J Bone Joint Surg Br 2007;89:742-745.
    • (2007) J Bone Joint Surg Br , vol.89 , pp. 742-745
    • Harvie, P.1    Haroon, M.2    Henderson, N.3    El-Guindi, M.4
  • 29
    • 34547591739 scopus 로고    scopus 로고
    • Fatigue fracture of a proximally modular, distally tapered fluted implant with diaphyseal fixation
    • Buttaro MA, Mayor MB, Van CD, Piccaluga F. Fatigue fracture of a proximally modular, distally tapered fluted implant with diaphyseal fixation. J Arthroplasty 2007;22:780-783.
    • (2007) J Arthroplasty , vol.22 , pp. 780-783
    • Buttaro, M.A.1    Mayor, M.B.2    Van, C.D.3    Piccaluga, F.4
  • 30
    • 0032935489 scopus 로고    scopus 로고
    • Effect of flexibility of the femoral stem on bone-remodeling and fixation of the stem in a canine total hip arthroplasty model without cement
    • Harvey EJ, Bobyn JD, Tanzer M, Stackpool GJ, Krygier JJ, Hacking SA. Effect of flexibility of the femoral stem on bone-remodeling and fixation of the stem in a canine total hip arthroplasty model without cement. J Bone Joint Surg Am 1999;81:93-107.
    • (1999) J Bone Joint Surg Am , vol.81 , pp. 93-107
    • Harvey, E.J.1    Bobyn, J.D.2    Tanzer, M.3    Stackpool, G.J.4    Krygier, J.J.5    Hacking, S.A.6
  • 31
    • 0023777583 scopus 로고
    • The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty
    • Engh CA, Bobyn JD. The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop Relat Res 1988;231:7-28.
    • (1988) Clin Orthop Relat Res , vol.231 , pp. 7-28
    • Engh, C.A.1    Bobyn, J.D.2
  • 32
    • 0036600202 scopus 로고    scopus 로고
    • Periprosthetic femoral fractures around well-fixed implants: Use of cortical onlay allografts with or without a plate
    • Haddad FS, Duncan CP, Berry DJ, Lewallen DG, Gross AE, Chandler HP. Periprosthetic femoral fractures around well-fixed implants: Use of cortical onlay allografts with or without a plate. J Bone Joint Surg Am 2002;84:945-950.
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 945-950
    • Haddad, F.S.1    Duncan, C.P.2    Berry, D.J.3    Lewallen, D.G.4    Gross, A.E.5    Chandler, H.P.6
  • 33
    • 33744968408 scopus 로고    scopus 로고
    • The shattered femur: Radical solution options
    • Lombardi AV Jr, Berend KR. The shattered femur: Radical solution options. J Arthroplasty 2006;21(Suppl 1):107-111.
    • (2006) J Arthroplasty , vol.21 , Issue.SUPPL. 1 , pp. 107-111
    • Lombardi Jr., A.V.1    Berend, K.R.2
  • 35
    • 0030175796 scopus 로고    scopus 로고
    • Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis
    • Akay M, Aslan N. Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis. J Biomed Mater Res 1996;31:167-182.
    • (1996) J Biomed Mater Res , vol.31 , pp. 167-182
    • Akay, M.1    Aslan, N.2
  • 36
    • 0031626714 scopus 로고    scopus 로고
    • Preliminary investigation of a novel controlled stiffness proximal femoral prosthesis
    • Simoes JA, Taylor M, Marques AT, Jeronimidis G. Preliminary investigation of a novel controlled stiffness proximal femoral prosthesis. Proc Inst Mech Eng [H] 1998;212:165-175.
    • (1998) Proc Inst Mech Eng [H] , vol.212 , pp. 165-175
    • Simoes, J.A.1    Taylor, M.2    Marques, A.T.3    Jeronimidis, G.4
  • 38
    • 20344374446 scopus 로고    scopus 로고
    • Bioactive hydroxyapatite coatings on polymer composites for orthopedic implants
    • Auclair-Daigle C, Bureau MN, Legoux JG, Yahia L. Bioactive hydroxyapatite coatings on polymer composites for orthopedic implants. J Biomed Mater Res A 2005;73:398-408.
    • (2005) J Biomed Mater Res A , vol.73 , pp. 398-408
    • Auclair-Daigle, C.1    Bureau, M.N.2    Legoux, J.G.3    Yahia, L.4
  • 39
    • 70349145005 scopus 로고    scopus 로고
    • Novel carbon fiber composite for hip replacement with improved in vitro and in vivo osseointegration
    • Dimitrievska S, Whitfield J, Hacking SA, Bureau MN. Novel carbon fiber composite for hip replacement with improved in vitro and in vivo osseointegration. J Biomed Mater Res A 2009;91:37-51.
    • (2009) J Biomed Mater Res A , vol.91 , pp. 37-51
    • Dimitrievska, S.1    Whitfield, J.2    Hacking, S.A.3    Bureau, M.N.4
  • 42
    • 0029164651 scopus 로고
    • The influence of surface-blasting on the incorporation of titaniumalloy implants in a rabbit intramedullary model
    • Feighan JE, Goldberg VM, Davy D, Parr JA, Stevenson S. The influence of surface-blasting on the incorporation of titaniumalloy implants in a rabbit intramedullary model. J Bone Joint Surg Am 1995;77:1380-1395.
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1380-1395
    • Feighan, J.E.1    Goldberg, V.M.2    Davy, D.3    Parr, J.A.4    Stevenson, S.5
  • 44
    • 38049022139 scopus 로고    scopus 로고
    • Human macrophage response to UHMWPE, TiAlV, CoCr, and alumina particles: Analysis of multiple cytokines using protein arrays
    • Kaufman AM, Alabre CI, Rubash HE, Shanbhag AS. Human macrophage response to UHMWPE, TiAlV, CoCr, and alumina particles: Analysis of multiple cytokines using protein arrays. J Biomed Mater Res A 2008;84:464-474.
    • (2008) J Biomed Mater Res A , vol.84 , pp. 464-474
    • Kaufman, A.M.1    Alabre, C.I.2    Rubash, H.E.3    Shanbhag, A.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.