메뉴 건너뛰기




Volumn 11, Issue 2, 2010, Pages 267-282

Electrically evoked auditory steady state responses in cochlear implant users

Author keywords

Apparent latency; Behavioral measures; Electrical stimulus; Electrophysiology; Objective measures

Indexed keywords

ADULT; ARTICLE; ARTIFACT; CLINICAL ARTICLE; CLINICAL TRIAL; COCHLEA PROSTHESIS; COCHLEAR NUCLEUS; ELECTRICALLY EVOKED AUDITORY STEADY STATE RESPONSE; ELECTRODE; ELECTROSTIMULATION; EVOKED AUDITORY RESPONSE; FEMALE; HUMAN; LATENT PERIOD; MALE; NERVE STIMULATION; PRIORITY JOURNAL; PULSE RATE; RADIOFREQUENCY; RECORDING; SCALP; SENSORY SYSTEM ELECTROPHYSIOLOGY; VALIDITY;

EID: 77954762968     PISSN: 15253961     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10162-009-0201-z     Document Type: Article
Times cited : (74)

References (59)
  • 1
    • 76449093556 scopus 로고    scopus 로고
    • Latencies of auditory steady-state responses recorded in early infancy
    • ALAERTS J, VAN DUN B, DESLOOVERE C, WOUTERS J (2009) Latencies of auditory steady-state responses recorded in early infancy. Audiol Neurootol 15(2):116-127.
    • (2009) Audiol Neurootol , vol.15 , Issue.2 , pp. 116-127
    • Alaerts, J.1    Van Dun, B.2    Desloovere, C.3    Wouters, J.4
  • 2
    • 0025662023 scopus 로고
    • A digital technique for stimulus artifact reduction
    • BLOGG T, REID WD (1990) A digital technique for stimulus artifact reduction. Electroencephalogr Clin Neurophysiol 76(6):557-561.
    • (1990) Electroencephalogr Clin Neurophysiol , vol.76 , Issue.6 , pp. 557-561
    • Blogg, T.1    Reid, W.D.2
  • 3
    • 54149109128 scopus 로고    scopus 로고
    • Generation of the 40-Hz auditory steady-state response (ASSR) explained using convolution
    • BOHORQUEZ J, OZDAMAR O (2008) Generation of the 40-Hz auditory steady-state response (ASSR) explained using convolution. Clin Neurophysiol 119(11):2598-2607.
    • (2008) Clin Neurophysiol , vol.119 , Issue.11 , pp. 2598-2607
    • Bohorquez, J.1    Ozdamar, O.2
  • 4
    • 0019732793 scopus 로고
    • Spectra of auditory brainstem responses and spontaneous EEG
    • BOSTON JR (1981) Spectra of auditory brainstem responses and spontaneous EEG. IEEE Trans Biomed Eng 28(4):334-341.
    • (1981) IEEE Trans Biomed Eng , vol.28 , Issue.4 , pp. 334-341
    • Boston, J.R.1
  • 5
    • 84903812023 scopus 로고    scopus 로고
    • Objective source selection in blind source separation of aeps in children with cochlear implants
    • CASTAÑEDA-VILLA N, JAMES CJ (2007) Objective source selection in blind source separation of aeps in children with cochlear implants. Conf Proc IEEE Eng Med Biol Soc 2007:6224-6227.
    • (2007) Conf Proc IEEE Eng Med Biol Soc , vol.2007 , pp. 6224-6227
    • Castañeda-Villa, N.1    James, C.J.2
  • 7
    • 0025787773 scopus 로고
    • A comparison of steady-state evoked potentials to modulated tones in awake and sleeping humans
    • COHEN LT, RICKARDS FW, CLARK GM (1991) A comparison of steady-state evoked potentials to modulated tones in awake and sleeping humans. J Acoust Soc Am 90(5):2467-2479.
    • (1991) J Acoust Soc Am , vol.90 , Issue.5 , pp. 2467-2479
    • Cohen, L.T.1    Rickards, F.W.2    Clark, G.M.3
  • 9
    • 0025738712 scopus 로고
    • Automatic reduction of stimulus polarization artifact for accurate evaluation of ventricular evoked responses
    • CURTIS AB, VANCE F, MILLER K (1991) Automatic reduction of stimulus polarization artifact for accurate evaluation of ventricular evoked responses. Pacing Clin Electrophysiol 14(4 Pt 1): 529-537.
    • (1991) Pacing Clin Electrophysiol , vol.14 , Issue.4 PART 1 , pp. 529-537
    • Curtis, A.B.1    Vance, F.2    Miller, K.3
  • 10
    • 0017903812 scopus 로고
    • Hybrid stimulator for chronic experiments
    • DEL POZO F, DELGADO JM (1978) Hybrid stimulator for chronic experiments. IEEE Trans Biomed Eng 25(1):92-94.
    • (1978) IEEE Trans Biomed Eng , vol.25 , Issue.1 , pp. 92-94
    • Del Pozo, F.1    Delgado, J.M.2
  • 11
    • 67349194084 scopus 로고    scopus 로고
    • Sensitivity to interaural time differences with combined cochlear implant and acoustic stimulation
    • FRANCART T, BROKX J, WOUTERS J (2009) Sensitivity to interaural time differences with combined cochlear implant and acoustic stimulation. J Assoc Res Otolaryngol 10(1):131-141.
    • (2009) J Assoc Res Otolaryngol , vol.10 , Issue.1 , pp. 131-141
    • Francart, T.1    Brokx, J.2    Wouters, J.3
  • 12
    • 0039058777 scopus 로고
    • A 40-Hz auditory potential recorded from the human scalp
    • GALAMBOS R, MAKEIG S, TALMACHOFF PJ (1981) A 40-Hz auditory potential recorded from the human scalp. Proc Natl Acad Sci USA 78(4):2643-2647.
    • (1981) Proc Natl Acad Sci USA , vol.78 , Issue.4 , pp. 2643-2647
    • Galambos, R.1    Makeig, S.2    Talmachoff, P.J.3
  • 14
    • 33746260319 scopus 로고    scopus 로고
    • Minimization of cochlear implant stimulus artifact in cortical auditory evoked potentials
    • GILLEY PM, SHARMA A, DORMAN MF, FINLEY CC, PANCH AS, MARTIN K (2006) Minimization of cochlear implant stimulus artifact in cortical auditory evoked potentials. Clin Neurophysiol 117 (8):1772-1782.
    • (2006) Clin Neurophysiol , vol.117 , Issue.8 , pp. 1772-1782
    • Gilley, P.M.1    Sharma, A.2    Dorman, M.F.3    Finley, C.C.4    Panch, A.S.5    Martin, K.6
  • 15
    • 0141621120 scopus 로고    scopus 로고
    • Spectral cancellation of microstimulation artifact for simultaneous neural recording in situ
    • GNADT JW, ECHOLS SD, YILDIRIM A, ZHANG H, PAUL K (2003) Spectral cancellation of microstimulation artifact for simultaneous neural recording in situ. IEEE Trans Biomed Eng 50(10):1129-1135.
    • (2003) IEEE Trans Biomed Eng , vol.50 , Issue.10 , pp. 1129-1135
    • Gnadt, J.W.1    Echols, S.D.2    Yildirim, A.3    Zhang, H.4    Paul, K.5
  • 17
    • 0018733246 scopus 로고
    • Auditory brainstem frequency following responses to waveform envelope periodicity
    • HALL J (1979) Auditory brainstem frequency following responses to waveform envelope periodicity. Science 205(4412):1297-1299.
    • (1979) Science , vol.205 , Issue.4412 , pp. 1297-1299
    • Hall, J.1
  • 18
    • 0037196235 scopus 로고    scopus 로고
    • A template subtraction method for stimulus artifact removal in high-frequency deep brain stimulation
    • HASHIMOTO T, ELDER CM, VITEK JL (2002) A template subtraction method for stimulus artifact removal in high-frequency deep brain stimulation. J Neurosci Methods 113(2):181-186.
    • (2002) J Neurosci Methods , vol.113 , Issue.2 , pp. 181-186
    • Hashimoto, T.1    Elder, C.M.2    Vitek, J.L.3
  • 20
    • 42049115683 scopus 로고    scopus 로고
    • Electrically evoked auditory steady-state responses in a Guinea pig model: Latency estimates and effects of stimulus parameters
    • JENG F-C, ABBAS PJ, BROWN CJ, MILLER CA, NOURSKI KV, ROBINSON BK (2008) Electrically evoked auditory steady-state responses in a guinea pig model: Latency estimates and effects of stimulus parameters. Audiol Neurootol 13(3):161-171.
    • (2008) Audiol Neurootol , vol.13 , Issue.3 , pp. 161-171
    • Jeng, F.-C.1    Abbas, P.J.2    Brown, C.J.3    Miller, C.A.4    Nourski, K.V.5    Robinson, B.K.6
  • 21
    • 0034006701 scopus 로고    scopus 로고
    • Human auditory steady-state responses to amplitude-modulated tones: phase and latency measurements
    • JOHN MS, PICTON TW (2000) Human auditory steady-state responses to amplitude-modulated tones: phase and latency measurements. Hear Res 141(1-2):57-79.
    • (2000) Hear Res , vol.141 , Issue.1-2 , pp. 57-79
    • John, M.S.1    Picton, T.W.2
  • 22
    • 0031915257 scopus 로고    scopus 로고
    • Multiple auditory steady-state responses (MASTER): stimulus and recording parameters
    • JOHN MS, LINS OG, BOUCHER BL, PICTON TW (1998) Multiple auditory steady-state responses (MASTER): stimulus and recording parameters. Audiology 37(2):59-82.
    • (1998) Audiology , vol.37 , Issue.2 , pp. 59-82
    • John, M.S.1    Lins, O.G.2    Boucher, B.L.3    Picton, T.W.4
  • 24
    • 0023817890 scopus 로고
    • Suppression of simulation artifacts from myoelectric-evoked potential recordings
    • KNAFLITZ M, MERLETTI R (1988) Suppression of simulation artifacts from myoelectric-evoked potential recordings. IEEE Trans Biomed Eng 35(9):758-763.
    • (1988) IEEE Trans Biomed Eng , vol.35 , Issue.9 , pp. 758-763
    • Knaflitz, M.1    Merletti, R.2
  • 26
    • 0036086083 scopus 로고    scopus 로고
    • Stimulus artifact cancellation in the serosal recordings of gastric myoelectric activity using wavelet transform
    • LIANG H, LIN Z (2002) Stimulus artifact cancellation in the serosal recordings of gastric myoelectric activity using wavelet transform. IEEE Trans Biomed Eng 49(7):681-688.
    • (2002) IEEE Trans Biomed Eng , vol.49 , Issue.7 , pp. 681-688
    • Liang, H.1    Lin, Z.2
  • 27
    • 0000694831 scopus 로고
    • Brief, non-injurious electric waveform for stimulation of the brain
    • LILLY JC, HUGHES JR, ALVORD EC, GALKIN TW (1955) Brief, non-injurious electric waveform for stimulation of the brain. Science 121(3144):468-469.
    • (1955) Science , vol.121 , Issue.3144 , pp. 468-469
    • Lilly, J.C.1    Hughes, J.R.2    Alvord, E.C.3    Galkin, T.W.4
  • 30
    • 0029073462 scopus 로고
    • Auditory steady-state responses to multiple simultaneous stimuli
    • LINS OG, PICTON TW (1995) Auditory steady-state responses to multiple simultaneous stimuli. Electroen-cephalogr Clin Neurophysiol 96(5):420-432.
    • (1995) Electroen-cephalogr Clin Neurophysiol , vol.96 , Issue.5 , pp. 420-432
    • Lins, O.G.1    Picton, T.W.2
  • 33
    • 0142026419 scopus 로고    scopus 로고
    • Improved temporal coding of sinusoids in electric stimulation of the auditory nerve using desynchronizing pulse trains
    • DOI 10.1121/1.1612493
    • LITVAK LM, DELGUTTE B, EDDINGTON DK (2003) Improved temporal coding of sinusoids in electric stimulation of the auditory nerve using desynchronizing pulse trains. J Acoust Soc Am 114(4 Pt 1):2079-2098. (Pubitemid 37266635)
    • (2003) Journal of the Acoustical Society of America , vol.114 , Issue.4 , pp. 2079-2098
    • Litvak, L.M.1    Delgutte, B.2    Eddington, D.K.3
  • 34
    • 30644459515 scopus 로고    scopus 로고
    • Clinical application of dichotic multiple-stimulus auditory steady-state responses in highrisk newborns and young children
    • LUTS H, DESLOOVERE C, WOUTERS J (2006) Clinical application of dichotic multiple-stimulus auditory steady-state responses in highrisk newborns and young children. Audiol Neurootol 11(1):24-37.
    • (2006) Audiol Neurootol , vol.11 , Issue.1 , pp. 24-37
    • Luts, H.1    Desloovere, C.2    Wouters, J.3
  • 37
    • 13144295003 scopus 로고    scopus 로고
    • Auditory steady-state response evaluation of auditory thresholds in cochlear implant patients
    • MENARD M, GALLEGO S, TRUY E, DURRANT B-V CJD, COLLET L (2004) Auditory steady-state response evaluation of auditory thresholds in cochlear implant patients. Int J Audiol 43(Suppl 1):39-43.
    • (2004) Int J Audiol , vol.43 , Issue.SUPPL. 1 , pp. 39-43
    • Menard, M.1    Gallego, S.2    Truy, E.3    Durrant, B.-V.C.J.D.4    Collet, L.5
  • 38
    • 48449103696 scopus 로고    scopus 로고
    • The clinical application of potentials evoked from the peripheral auditory system
    • MILLER CA, BROWN CJ, ABBAS PJ, CHI SL (2008) The clinical application of potentials evoked from the peripheral auditory system. Hear Res 242(1-2):184-197.
    • (2008) Hear Res , vol.242 , Issue.1-2 , pp. 184-197
    • Miller, C.A.1    Brown, C.J.2    Abbas, P.J.3    Chi, S.L.4
  • 39
    • 0027500738 scopus 로고
    • Reduced variance in the latency and amplitude of the fifth wave of auditory brain stem response after normalization for head size
    • NIKIFORIDIS GC, KOUTSOJANNIS CM, VARAKIS JN, GOUMAS PD (1993) Reduced variance in the latency and amplitude of the fifth wave of auditory brain stem response after normalization for head size. Ear Hear 14(6):423-428.
    • (1993) Ear Hear , vol.14 , Issue.6 , pp. 423-428
    • Nikiforidis, G.C.1    Koutsojannis, C.M.2    Varakis, J.N.3    Goumas, P.D.4
  • 40
    • 0032005079 scopus 로고    scopus 로고
    • Adaptive stimulus artifact reduction in noncortical somatosensory evoked potential studies
    • PARSA V, PARKER PA, SCOTT RN (1998) Adaptive stimulus artifact reduction in noncortical somatosensory evoked potential studies. IEEE Trans Biomed Eng 45(2):165-179.
    • (1998) IEEE Trans Biomed Eng , vol.45 , Issue.2 , pp. 165-179
    • Parsa, V.1    Parker, P.A.2    Scott, R.N.3
  • 42
    • 11144352760 scopus 로고    scopus 로고
    • Human temporal auditory acuity as assessed by envelope following responses
    • PURCELL DW, JOHN MS, SCHNEIDER BA, PICTON TW (2004) Human temporal auditory acuity as assessed by envelope following responses. J Acoust Soc Am 116(6):3581-3593.
    • (2004) J Acoust Soc Am , vol.116 , Issue.6 , pp. 3581-3593
    • Purcell, D.W.1    John, M.S.2    Schneider, B.A.3    Picton, T.W.4
  • 43
    • 0036557942 scopus 로고    scopus 로고
    • Prediction of hearing threshold in infants using auditory steady-state evoked potentials
    • RANCE G, RICKARDS F (2002) Prediction of hearing threshold in infants using auditory steady-state evoked potentials. J Am Acad Audiol 13(5):236-245.
    • (2002) J Am Acad Audiol , vol.13 , Issue.5 , pp. 236-245
    • Rance, G.1    Rickards, F.2
  • 44
    • 0028803337 scopus 로고
    • The automated prediction of hearing thresholds in sleeping subjects using auditory steady-state evoked potentials
    • RANCE G, RICKARDS FW, COHEN LT, DE VIDI S, CLARK GM (1995) The automated prediction of hearing thresholds in sleeping subjects using auditory steady-state evoked potentials. Ear Hear 16 (5):499-507.
    • (1995) Ear Hear , vol.16 , Issue.5 , pp. 499-507
    • Rance, G.1    Rickards, F.W.2    Cohen, L.T.3    De Vidi, S.4    Clark, G.M.5
  • 45
    • 0031149275 scopus 로고    scopus 로고
    • Stimulus artefact in somatosensory evoked potential measurement
    • SCOTT RN, MCLEAN L, PARKER PA (1997) Stimulus artefact in somatosensory evoked potential measurement. Med Biol Eng Comput 35(3):211-215.
    • (1997) Med Biol Eng Comput , vol.35 , Issue.3 , pp. 211-215
    • Scott, R.N.1    McLean, L.2    Parker, P.A.3
  • 46
    • 0031170811 scopus 로고    scopus 로고
    • Functional neuromuscular stimulation controlled by surface electromyographic signals produced by volitional activation of the same muscle: Adaptive removal of the muscle response from the recorded EMG-signal
    • SENNELS S, BIERING-SORENSEN F, ANDERSEN OT, HANSEN SD (1997) Functional neuromuscular stimulation controlled by surface electromyographic signals produced by volitional activation of the same muscle: adaptive removal of the muscle response from the recorded EMG-signal. IEEE Trans Rehabil Eng 5(2):195-206.
    • (1997) IEEE Trans Rehabil Eng , vol.5 , Issue.2 , pp. 195-206
    • Sennels, S.1    Biering-Sorensen, F.2    Andersen, O.T.3    Hansen, S.D.4
  • 47
    • 0025269220 scopus 로고
    • Electrically evoked auditory brain stem responses (EABR) and middle latency responses (EMLR) obtained from patients with the Nucleus multichannel Cochlear implant
    • SHALLOP JK, BEITER AL, GOIN DW, MISCHKE RE (1990) Electrically evoked auditory brain stem responses (EABR) and middle latency responses (EMLR) obtained from patients with the Nucleus multichannel Cochlear implant. Ear Hear 11(1):5-15.
    • (1990) Ear Hear , vol.11 , Issue.1 , pp. 5-15
    • Shallop, J.K.1    Beiter, A.L.2    Goin, D.W.3    Mischke, R.E.4
  • 48
    • 0036970158 scopus 로고    scopus 로고
    • Speech perception in Nucleus CI24M Cochlear implant users with processor settings based on electrically evoked compound action potential thresholds
    • SMOORENBURG GF, WILLEBOER C, VAN DIJK JE (2002) Speech perception in Nucleus CI24M Cochlear implant users with processor settings based on electrically evoked compound action potential thresholds. Audiol Neurootol 7(6):335-347.
    • (2002) Audiol Neurootol , vol.7 , Issue.6 , pp. 335-347
    • Smoorenburg, G.F.1    Willeboer, C.2    Van Dijk, J.E.3
  • 49
    • 0019522555 scopus 로고
    • An automatic, optically isolated, biphasic constant current stimulator adapter for artefact suppression
    • SPENCER HJ (1981) An automatic, optically isolated, biphasic constant current stimulator adapter for artefact suppression. Electroencephalogr Clin Neurophysiol 51(2):215-217.
    • (1981) Electroencephalogr Clin Neurophysiol , vol.51 , Issue.2 , pp. 215-217
    • Spencer, H.J.1
  • 51
    • 0023184371 scopus 로고
    • Auditory steady-state responses: threshold prediction using phase coherence
    • STAPELLS DR, MAKEIG S, GALAMBOS R (1987) Auditory steady-state responses: threshold prediction using phase coherence. Electroencephalogr Clin Neurophysiol 67(3):260-270.
    • (1987) Electroencephalogr Clin Neurophysiol , vol.67 , Issue.3 , pp. 260-270
    • Stapells, D.R.1    Makeig, S.2    Galambos, R.3
  • 52
    • 39749122765 scopus 로고    scopus 로고
    • A flexible research platform for multi-channel auditory steady-state response measurements
    • VAN DUN B, VERSTRAETEN S, ALAERTS J, LUTS H, MOONEN M, WOUTERS J (2008) A flexible research platform for multi-channel auditory steady-state response measurements. J Neurosci Methods 169(1):239-248.
    • (2008) J Neurosci Methods , vol.169 , Issue.1 , pp. 239-248
    • Van Dun, B.1    Verstraeten, S.2    Alaerts, J.3    Luts, H.4    Moonen, M.5    Wouters, J.6
  • 53
    • 68149091220 scopus 로고    scopus 로고
    • Optimal electrode selection for multi-channel electroencephalogram based detection of auditory steady-state responses
    • VANDUN B, WOUTERS J, MOONEN M (2009) Optimal electrode selection for multi-channel electroencephalogram based detection of auditory steady-state responses. J Acoust Soc Am 126(1):254-268.
    • (2009) J Acoust Soc Am , vol.126 , Issue.1 , pp. 254-268
    • Vandun, B.1    Wouters, J.2    Moonen, M.3
  • 54
    • 0035665424 scopus 로고    scopus 로고
    • Comparison of procedures to determine electrical stimulation thresholds in cochlear implant users
    • VAN WIERINGEN A, WOUTERS J (2001) Comparison of procedures to determine electrical stimulation thresholds in cochlear implant users. Ear Hear 22(6):528-538.
    • (2001) Ear Hear , vol.22 , Issue.6 , pp. 528-538
    • Van Wieringen, A.1    Wouters, J.2
  • 55
    • 0037201958 scopus 로고    scopus 로고
    • Real-time multi-channel stimulus artifact suppression by local curve fitting
    • WAGENAAR DA, POTTER SM (2002) Real-time multi-channel stimulus artifact suppression by local curve fitting. J Neurosci Methods 120(2):113-120.
    • (2002) J Neurosci Methods , vol.120 , Issue.2 , pp. 113-120
    • Wagenaar, D.A.1    Potter, S.M.2
  • 57
    • 21844455800 scopus 로고    scopus 로고
    • A closed-loop electrical stimulation system for cardiac cell cultures
    • WHITTINGTON RH, GIOVANGRANDI L, KOVACS GT (2005) A closed-loop electrical stimulation system for cardiac cell cultures. IEEE Trans Biomed Eng 52(7):1261-1270.
    • (2005) IEEE Trans Biomed Eng , vol.52 , Issue.7 , pp. 1261-1270
    • Whittington, R.H.1    Giovangrandi, L.2    Kovacs, G.T.3
  • 58
    • 0027875122 scopus 로고
    • Pulse time modulation techniques for optical communications: a review
    • WILSON B, GHASSEMLOOY Z (1993) Pulse time modulation techniques for optical communications: a review. IEE Proc Optoelectron 140(6):347-357.
    • (1993) IEE Proc Optoelectron , vol.140 , Issue.6 , pp. 347-357
    • Wilson, B.1    Ghassemlooy, Z.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.