메뉴 건너뛰기




Volumn 45, Issue 8, 2010, Pages 477-483

A Concept for magnetic resonance visualization of surgical textile implants

Author keywords

Abdominal hernia; IRON; Magnetic resonance imaging; On resonant suppression; Positive contrast; Textile mesh implants

Indexed keywords

AGAROSE; SUPERPARAMAGNETIC IRON OXIDE; WATER;

EID: 77954761869     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0b013e3181e53e38     Document Type: Article
Times cited : (40)

References (35)
  • 1
    • 39849083765 scopus 로고    scopus 로고
    • Frequency of postoperative inguinal hernia after endoscope assisted mini-laparotomy and conventional retropubic radical prostatectomies
    • Koie T, Yoneyama T, Kamimura N, et al. Frequency of postoperative inguinal hernia after endoscope assisted mini-laparotomy and conventional retropubic radical prostatectomies. Int J Urol. 2008;15:226-229.
    • (2008) Int J Urol , vol.15 , pp. 226-229
    • Koie, T.1    Yoneyama, T.2    Kamimura, N.3
  • 3
    • 4644286793 scopus 로고    scopus 로고
    • Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia
    • Burger JW, Luijendijk RW, Hop WC, et al. Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg. 2004;240:578-583.
    • (2004) Ann Surg , vol.240 , pp. 578-583
    • Burger, J.W.1    Luijendijk, R.W.2    Hop, W.C.3
  • 4
    • 33646583006 scopus 로고    scopus 로고
    • The management of incisional hernia
    • Kingsnorth A. The management of incisional hernia. Ann R Coll Surg Engl. 2006;88:252-260.
    • (2006) Ann R Coll Surg Engl , vol.88 , pp. 252-260
    • Kingsnorth, A.1
  • 5
    • 48449106189 scopus 로고    scopus 로고
    • Mesh repair of common abdominal hernias: A review on experimental and clinical studies
    • Penttinen R, Grönroos JM. Mesh repair of common abdominal hernias: a review on experimental and clinical studies. Hernia. 2008;12:337-344.
    • (2008) Hernia , vol.12 , pp. 337-344
    • Penttinen, R.1    Grönroos, J.M.2
  • 6
    • 0141507927 scopus 로고    scopus 로고
    • Demographic and socioeconomic aspects of hernia repair in the United States in 2003
    • v-vi
    • Rutkow IM. Demographic and socioeconomic aspects of hernia repair in the United States in 2003. Surg Clin North Am. 2003;83:1045-1051, v-vi.
    • (2003) Surg Clin North Am. , vol.83 , pp. 1045-1051
    • Rutkow, I.M.1
  • 7
    • 0036349949 scopus 로고    scopus 로고
    • Impact of polymer pore size on the interface scar formation in a rat model
    • Klinge U, Klosterhalfen B, Birkenhauer V, et al. Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res. 2002;103:208-214.
    • (2002) J Surg Res , vol.103 , pp. 208-214
    • Klinge, U.1    Klosterhalfen, B.2    Birkenhauer, V.3
  • 8
    • 0036209716 scopus 로고    scopus 로고
    • Functional and morphological evaluation of a low-weight, monofilament polypropylene mesh for hernia repair
    • Klinge U, Junge K, Stumpf M, et al. Functional and morphological evaluation of a low-weight, monofilament polypropylene mesh for hernia repair. J Biomed Mater Res. 2002;63:129-136.
    • (2002) J Biomed Mater Res , vol.63 , pp. 129-136
    • Klinge, U.1    Junge, K.2    Stumpf, M.3
  • 9
    • 0031923072 scopus 로고    scopus 로고
    • Long-term complications associated with prosthetic repair of incisional hernias
    • Leber GE, Garb JL, Alexander AI, et al. Long-term complications associated with prosthetic repair of incisional hernias. Arch Surg. 1998;133:378-382.
    • (1998) Arch Surg , vol.133 , pp. 378-382
    • Leber, G.E.1    Garb, J.L.2    Alexander, A.I.3
  • 10
    • 33746999299 scopus 로고    scopus 로고
    • Pain and functional impairment 6 years after inguinal herniorrhaphy
    • DOI 10.1007/s10029-006-0098-y
    • Aasvang EK, Bay-Nielsen M, Kehlet H. Pain and functional impairment 6 years after inguinal herniorrhaphy. Hernia. 2006;10:316-321. (Pubitemid 44203405)
    • (2006) Hernia , vol.10 , Issue.4 , pp. 316-321
    • Aasvang, E.K.1    Bay-Nielsen, M.2    Kehlet, H.3
  • 11
    • 77954689086 scopus 로고    scopus 로고
    • Mesh erosion into the urinary bladder following laparoscopic inguinal hernia repair; Is this the tip of the iceberg?
    • Hamouda A, Kennedy J, Grant N, et al. Mesh erosion into the urinary bladder following laparoscopic inguinal hernia repair; is this the tip of the iceberg? Hernia. 2010;14:317-319.
    • (2010) Hernia , vol.14 , pp. 317-319
    • Hamouda, A.1    Kennedy, J.2    Grant, N.3
  • 13
    • 0034632866 scopus 로고    scopus 로고
    • A comparison of suture repair with mesh repair for incisional hernia
    • Luijendijk RW, Hop WC, van den Tol MP, et al. A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med. 2000;343:392-398.
    • (2000) N Engl J Med , vol.343 , pp. 392-398
    • Luijendijk, R.W.1    Hop, W.C.2    Van Den Tol, M.P.3
  • 14
    • 3843127416 scopus 로고    scopus 로고
    • Imaging of early postoperative complications after polypropylene mesh repair of inguinal hernia
    • Crespi G, Giannetta E, Mariani F, et al. Imaging of early postoperative complications after polypropylene mesh repair of inguinal hernia. Radiol Med. 2004;108:107-115.
    • (2004) Radiol Med , vol.108 , pp. 107-115
    • Crespi, G.1    Giannetta, E.2    Mariani, F.3
  • 15
    • 35949003609 scopus 로고    scopus 로고
    • Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-resonant water suppression (IRON)
    • Stuber M, Gilson WD, Schär M, et al. Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-resonant water suppression (IRON). Magn Reson Med. 2007;58:1072-1077.
    • (2007) Magn Reson Med , vol.58 , pp. 1072-1077
    • Stuber, M.1    Gilson, W.D.2    Schär, M.3
  • 16
    • 47149091319 scopus 로고    scopus 로고
    • Syn thesis, physicochemical characterization and MR relaxometry of aqueous ferrofluids
    • Hodenius MA, Niendorf T, Krombach GA, et al. Synthesis, physicochemical characterization and MR relaxometry of aqueous ferrofluids. J Nanosci Nanotechnol. 2008;8:2399-2409.
    • (2008) J Nanosci Nanotechnol , vol.8 , pp. 2399-2409
    • Hodenius, M.A.1    Niendorf, T.2    Krombach, G.A.3
  • 17
    • 27244438481 scopus 로고    scopus 로고
    • Composition of MRI phantom equivalent to human tissues
    • Kato H, Kuroda M, Yoshimura K, et al. Composition of MRI phantom equivalent to human tissues. Med Phys. 2005;32:3199-3208.
    • (2005) Med Phys , vol.32 , pp. 3199-3208
    • Kato, H.1    Kuroda, M.2    Yoshimura, K.3
  • 18
    • 56149083342 scopus 로고    scopus 로고
    • Off-resonance angiography: A new method to depict vessels\phantom and rabbit studies
    • Korosoglou G, Shah S, Vonken EJ, et al. Off-resonance angiography: a new method to depict vessels\phantom and rabbit studies. Radiology. 2008;49: 501-509.
    • (2008) Radiology , vol.49 , pp. 501-509
    • Korosoglou, G.1    Shah, S.2    Vonken, E.J.3
  • 19
    • 42949145900 scopus 로고    scopus 로고
    • Positive contrast MR-lymphog-raphy using inversion recovery with ON-resonant water suppression (IRON)
    • Korosoglou G, Tang L, Kedziorek D, et al. Positive contrast MR-lymphog-raphy using inversion recovery with ON-resonant water suppression (IRON). J Magn Reson Imaging. 2008;7:1175-1180.
    • (2008) J Magn Reson Imaging , vol.7 , pp. 1175-1180
    • Korosoglou, G.1    Tang, L.2    Kedziorek, D.3
  • 20
  • 21
  • 22
    • 20244380339 scopus 로고    scopus 로고
    • Magnetic resonance-guided percutaneous angioplasty of femoral and popliteal artery stenoses using real-time imaging and intra-arterial contrast-enhanced magnetic resonance angiogra-phy
    • Paetzel C, Zorger N, Bachthaler M, et al. Magnetic resonance-guided percutaneous angioplasty of femoral and popliteal artery stenoses using real-time imaging and intra-arterial contrast-enhanced magnetic resonance angiogra-phy. Invest Radiol. 2005;40:257-262.
    • (2005) Invest Radiol , vol.40 , pp. 257-262
    • Paetzel, C.1    Zorger, N.2    Bachthaler, M.3
  • 23
    • 0033800058 scopus 로고    scopus 로고
    • Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters
    • Omary RA, Unal O, Koscielski DS. Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters. J Vasc Interv Radiol. 2000;11:1079-1085.
    • (2000) J Vasc Interv Radiol , vol.11 , pp. 1079-1085
    • Omary, R.A.1    Unal, O.2    Koscielski, D.S.3
  • 24
    • 34247881894 scopus 로고    scopus 로고
    • MR contrast agents: Physical and pharmacologic basics
    • Lin SP, Brown JJ. MR contrast agents: physical and pharmacologic basics. J Magn Reson Imaging. 2007;5:884-899.
    • (2007) J Magn Reson Imaging , vol.5 , pp. 884-899
    • Lin, S.P.1    Brown, J.J.2
  • 25
    • 7044247646 scopus 로고    scopus 로고
    • Use of a nonmetallic guide wire for magnetic resonance-guided coronary artery catheterization
    • Buecker A, Spuentrup E, Schmitz-Rode T, et al. Use of a nonmetallic guide wire for magnetic resonance-guided coronary artery catheterization. Invest Radiol. 2004;39:656-660.
    • (2004) Invest Radiol , vol.39 , pp. 656-660
    • Buecker, A.1    Spuentrup, E.2    Schmitz-Rode, T.3
  • 26
    • 67651037332 scopus 로고    scopus 로고
    • Preclinical evaluation of a novel fiber compound MR guidewire in vivo
    • Krämer NA, Krüger S, Schmitz S, et al. Preclinical evaluation of a novel fiber compound MR guidewire in vivo. Invest Radiol. 2009;4:390-397.
    • (2009) Invest Radiol , vol.4 , pp. 390-397
    • Krämer, N.A.1    Krüger, S.2    Schmitz, S.3
  • 27
    • 18244402192 scopus 로고    scopus 로고
    • Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles
    • Cunningham CH, Arai T, Yang PC, et al. Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles. Magn Reson Med. 2005;3:999-1005.
    • (2005) Magn Reson Med , vol.3 , pp. 999-1005
    • Cunningham, C.H.1    Arai, T.2    Yang, P.C.3
  • 28
    • 51449123653 scopus 로고    scopus 로고
    • Susceptibility gradient mapping (SGM): A new postprocessing method for positive contrast generation applied to superparamagnetic iron oxide particle (SPIO)-labeled cells
    • Dahnke H, Liu W, Herzka D, et al. Susceptibility gradient mapping (SGM): a new postprocessing method for positive contrast generation applied to superparamagnetic iron oxide particle (SPIO)-labeled cells. Magn Reson Med. 2008;60:595-603.
    • (2008) Magn Reson Med , vol.60 , pp. 595-603
    • Dahnke, H.1    Liu, W.2    Herzka, D.3
  • 29
    • 33747595007 scopus 로고    scopus 로고
    • Generating positive contrast from off-resonant spins with steady-state free precession magnetic resonance imaging: Theory and proof-of-principle experiments
    • Dharmakumar R, Koktzoglou I, Li D. Generating positive contrast from off-resonant spins with steady-state free precession magnetic resonance imaging: theory and proof-of-principle experiments. Phys Med Biol. 2006; 51:4201-15.
    • (2006) Phys Med Biol , vol.51 , pp. 4201-4215
    • Dharmakumar, R.1    Koktzoglou, I.2    Li, D.3
  • 30
    • 67349158085 scopus 로고    scopus 로고
    • Positive contrast visualization for cellular magnetic resonance imaging using susceptibility-weighted echo-time encoding
    • Kim YB, Bae KH, Yoo SS, et al. Positive contrast visualization for cellular magnetic resonance imaging using susceptibility-weighted echo-time encoding. Magn Reson Imaging. 2009;27:601-610.
    • (2009) Magn Reson Imaging , vol.27 , pp. 601-610
    • Kim, Y.B.1    Bae, K.H.2    Yoo, S.S.3
  • 31
    • 33644791275 scopus 로고    scopus 로고
    • Alternating repetition time balanced steady state free precession
    • Leupold J, Hennig J, Scheffler K. Alternating repetition time balanced steady state free precession. Magn Reson Med. 2006;55:557-565.
    • (2006) Magn Reson Med , vol.55 , pp. 557-565
    • Leupold, J.1    Hennig, J.2    Scheffler, K.3
  • 32
    • 34249869807 scopus 로고    scopus 로고
    • In vivo magnetic resonance imaging of iron oxide-labeled, arterially-injected mesenchymal stem cells in kidneys of rats with acute ischemic kidney injury: Detection and monitoring at 3T
    • Ittrich H, Lange C, Tögel F, et al. In vivo magnetic resonance imaging of iron oxide-labeled, arterially-injected mesenchymal stem cells in kidneys of rats with acute ischemic kidney injury: detection and monitoring at 3T. J Magn Reson Imaging. 2007;25:1179-1191.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 1179-1191
    • Ittrich, H.1    Lange, C.2    Tögel, F.3
  • 33
    • 47949124259 scopus 로고    scopus 로고
    • Noninvasive detection of macrophage-rich atherosclerotic plaque in hyperlipidemic rabbits using "positive contrast" magnetic resonance imaging
    • Korosoglou G, Weiss RG, Kedziorek DA, et al. Noninvasive detection of macrophage-rich atherosclerotic plaque in hyperlipidemic rabbits using "positive contrast" magnetic resonance imaging. J Am Coll Cardiol. 2008;52:483-491.
    • (2008) J Am Coll Cardiol , vol.52 , pp. 483-491
    • Korosoglou, G.1    Weiss, R.G.2    Kedziorek, D.A.3
  • 34
    • 51449113662 scopus 로고    scopus 로고
    • Positive contrast visualization of nitinol devices using susceptibility gradient mapping
    • Vonken EJ, Schär M, Stuber M. Positive contrast visualization of nitinol devices using susceptibility gradient mapping. Magn Reson Med. 2008;60: 588-594.
    • (2008) Magn Reson Med , vol.60 , pp. 588-594
    • Vonken, E.J.1    Schär, M.2    Stuber, M.3
  • 35
    • 33750356735 scopus 로고    scopus 로고
    • Positive-contrast imaging in the rabbit hind-limb of transplanted cells bearing endocytosed superparamag-netic beads
    • Foltz WD, Cunningham CH, Mutsaers AJ, et al. Positive-contrast imaging in the rabbit hind-limb of transplanted cells bearing endocytosed superparamag-netic beads. J Cardiovasc Magn Reson. 2006;8:817-823.
    • (2006) J Cardiovasc Magn Reson , vol.8 , pp. 817-823
    • Foltz, W.D.1    Cunningham, C.H.2    Mutsaers, A.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.