-
2
-
-
67549100824
-
Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA)
-
Heart Rhythm Society; American Heart Association
-
Wilkoff BL, Love CJ, Byrd CL, et al. Heart Rhythm Society; American Heart Association. Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). Heart Rhythm 2009; 6: 1085-1104.
-
(2009)
Heart Rhythm
, vol.6
, pp. 1085-1104
-
-
Wilkoff, B.L.1
Love, C.J.2
Byrd, C.L.3
-
3
-
-
44349179244
-
Extraction of transvenous pacing and ICD leads
-
Smith MC, Love CJ. Extraction of transvenous pacing and ICD leads. Pacing Clin Electrophysiol 2008; 31: 736-752.
-
(2008)
Pacing Clin Electrophysiol
, vol.31
, pp. 736-752
-
-
Smith, M.C.1
Love, C.J.2
-
4
-
-
0033133418
-
Pacemaker lead extraction with the laser sheath: Results of the pacing lead extraction with the excimer sheath (PLEXES) trial
-
Wilkoff BL, Byrd CL, Love CJ, et al. Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial. J Am Coll Cardiol 1999; 33: 1671-1676.
-
(1999)
J Am Coll Cardiol
, vol.33
, pp. 1671-1676
-
-
Wilkoff, B.L.1
Byrd, C.L.2
Love, C.J.3
-
5
-
-
34547945157
-
Laser-assisted lead extraction: The European experience
-
PLESSE investigators group
-
Kennergren C, Bucknall CA, Butter C, et al. PLESSE investigators group. Laser-assisted lead extraction: the European experience. Europace 2007; 9: 651-656.
-
(2007)
Europace
, vol.9
, pp. 651-656
-
-
Kennergren, C.1
Bucknall, C.A.2
Butter, C.3
-
6
-
-
37549023768
-
European perspective on lead extraction: Part I
-
Kennergren CA. European perspective on lead extraction: part I. Heart Rhythm 2008; 5: 160-162.
-
(2008)
Heart Rhythm
, vol.5
, pp. 160-162
-
-
Kennergren, C.A.1
-
7
-
-
38649117955
-
European perspective on lead extraction: Part II
-
Kennergren CA. European perspective on lead extraction: part II. Heart Rhythm 2008; 5: 320-323.
-
(2008)
Heart Rhythm
, vol.5
, pp. 320-323
-
-
Kennergren, C.A.1
-
8
-
-
33846928759
-
Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: Results of a randomized trial
-
DOI 10.1093/europace/eul171
-
Neuzil P, Taborsky M, Rezek Z, et al. Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: results of a randomized trial. Europace 2007; 9: 98-104. (Pubitemid 46237972)
-
(2007)
Europace
, vol.9
, Issue.2
, pp. 98-104
-
-
Neuzil, P.1
Taborsky, M.2
Rezek, Z.3
Vopalka, R.4
Sediva, L.5
Niederle, P.6
Reddy, V.7
-
9
-
-
64649092524
-
Percutaneous extraction of endocardial leads - A single centre experience in 120 patients
-
Kutarski A, Małecka B, Ruciński P, et al. Percutaneous extraction of endocardial leads - a single centre experience in 120 patients. Kardiol Pol 2009; 67: 149-156.
-
(2009)
Kardiol Pol
, vol.67
, pp. 149-156
-
-
Kutarski, A.1
Małecka, B.2
Ruciński, P.3
-
10
-
-
57349111725
-
Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: High success rate and safety in more than 2000 leads
-
Bongiorni MG, Soldati E, Zucchelli G, et al. Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads. Eur Heart J 2008; 29: 2886-2893.
-
(2008)
Eur Heart J
, vol.29
, pp. 2886-2893
-
-
Bongiorni, M.G.1
Soldati, E.2
Zucchelli, G.3
-
11
-
-
77953839609
-
Initial experience with the Evolution mechanical dilator sheath for leadextraction: Safety and efficacy
-
Mar 23
-
Hussein AA, Wilkoff BL, Martin DO, et al. Initial experience with the Evolution mechanical dilator sheath for leadextraction: safety and efficacy. Heart Rhythm 2010 Mar 23.
-
(2010)
Heart Rhythm
-
-
Hussein, A.A.1
Wilkoff, B.L.2
Martin, D.O.3
-
12
-
-
71049192265
-
Single-operator experience with a mechanical approach for removal of pacing and implantable defibrillator leads
-
Calvagna GM, Evola R, Scardace G, et al. Single-operator experience with a mechanical approach for removal of pacing and implantable defibrillator leads. Europace 2009; 11: 1505-1509.
-
(2009)
Europace
, vol.11
, pp. 1505-1509
-
-
Calvagna, G.M.1
Evola, R.2
Scardace, G.3
-
13
-
-
40849114529
-
Large, single-center, single-operator experience with transvenous lead extraction: Outcomes and changing indications
-
Jones SO 4th, Eckart RE, Albert CM, et al. Large, single-center, single-operator experience with transvenous lead extraction: outcomes and changing indications. Heart Rhythm 2008; 5: 520-525.
-
(2008)
Heart Rhythm
, vol.5
, pp. 520-525
-
-
Jones IV, S.O.1
Eckart, R.E.2
Albert, C.M.3
-
14
-
-
70449344705
-
Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: Intracardiac findings near their leads and electrodes
-
Novak M, Dvorak P, Kamaryt P, et al. Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near their leads and electrodes. Europace 2009; 11: 1510-1516.
-
(2009)
Europace
, vol.11
, pp. 1510-1516
-
-
Novak, M.1
Dvorak, P.2
Kamaryt, P.3
-
15
-
-
66749148454
-
A single-centre experience of over one thousand lead extractions
-
Kennergren C, Bjurman C, Wiklund R, Gäbel J. A single-centre experience of over one thousand lead extractions. Europace 2009; 11: 612-617.
-
(2009)
Europace
, vol.11
, pp. 612-617
-
-
Kennergren, C.1
Bjurman, C.2
Wiklund, R.3
Gäbel, J.4
|